Accessories for Vessels

Similar documents
AHD-RB6 Electronic Circuit Breaker (ECB) Type C

ADDITIONAL MARINE PRODUCTS BELONGS TO MARINE CATALOG 2010

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

- NLS NAVIGATION LIGHT CONTROL

Luminaire testing device

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Installation & Operation Manual

QUINT-PS/ 1AC/24DC/20/CO

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

ABB i-bus KNX Switch Actuator, x-fold, 6 A, MDRC SA/S x.6.1.1, 2CDG x R0011

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

CLIPLINE complete. The modular terminal block system for all applications

MTeC - EPT202 Digital thermometer Messko

Series DiTemp Series SolarTemp. Digital Thermometers

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Ellab Temperature Indicator

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Plexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only.

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Electronic Temperature Controller. Instruction Manual Version

DATA SHEET Advanced Graphical Interface, AGI 300 series

Leica KL200 LED / Leica L2

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling. 360b/01

Product type designation. Control elements. Installation type/mounting

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Rotary Measurement Technology Absolute Encoders, Singleturn

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

FT2040 Fire terminal. Sinteso. FS20 series

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

CU port USB 2.0 hub. Version: 1.1 Date:

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Control & Automation Products

Technical Information Promonitor NRF560

tapcon 230 user-friendly, FleXiBle and reliable. transformer control

FT724. Fire terminal. Cerberus PRO. FS720 series, IP6

selos The Wieland Terminal. selos New Generation Wieland Electric, inventor of the safe connection. Fast on the Rail

Rotary Measurement Technology Absolute Encoders, Multiturn

Rotary Measuring Technology Absolute encoders, Singleturn, Profibus-DP

M C. Ex d M-0... control, monitoring and signalling devices

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

LED SIGNAL DOME RELIABLE USER INTERACTION. starts in the design process of the machine

Accessories for pluggable interface relays CR-P Sockets

DALI Professional Controller-4. Control unit Operating instructions

SUPER LEDF10HP DATASHEET

Product list Part Number. Stacked / Double. Horizontal (1); (1) Vertical

Web: Tel: (02) Fax: (02)

LINETRAXX RCMS150. Residual current monitor type B with integrated measuring current transformers for earthed AC/DC systems (TN and TT systems)

SUPER LEDF6 DATASHEET

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Operating voltage Maximum

ABB i-bus KNX Switch Actuator, Current Detection, x-fold, 16/20 A, C-Load, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

TECHNICAL DATASHEET Absolute Encoder AC 58 - SUCOnet

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Pneumatic Control/Feedback

Original operating instructions Fail-safe inductive sensor GI712S

KFA-37HD8. Relay-type Annunciators with LED Lights. Features 6-36 KFA-37HD8

SITOP in the SIMATIC Design

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Pneumatic Control/Feedback

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

Neon pr. ph/ ORP measurement. Applications. Description

DeltaV Bulk Power Supplies

Rotary Measuring Technology Absolute encoders, Multiturn, Profibus-DP

Leak Sensor. TOYOKO KAGAKU CO., LTD. Kawasaki, Kanagawa, Japan

DeltaV Bulk Power Supplies

ENCODER. Profibus Multiturn. Series , Key-Features:

Rotary Position Technology Incremental Encoders

Photoelectric Sensors E3F2

Technical Data. General specifications. Rated operating distance s n 3 mm

Switching module for AC V and up to three load stages, with manual switching

NL-02 NL-02. The NL-02 InoxLaser uses time-offlight laser technology for continuous non-contact distance or level measurement.

DC561, digital input/output module,

E2Q4 Square Proximity Sensor

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

Binary output and supervision 520CSD01 Data sheet

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

DMX Dimmer DMX Touch panel decoder with 2.4G remote TM083

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2TAZ710xx1R2161

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

DX561 Digital Input/Output Module

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Product list Product Mounting type Part Number. Double Mounting base Baseplate

Technical Information WirelessHART Fieldgate SWG70

PLC-OSC-120UC/ 24DC/ 2

Weighing Electronics SIWAREX - PLC-based weighing electronics

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

DC562, digital input/output module,

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Transcription:

Accessories for Vessels Small Things Make a Big Difference LED Navigation Lights

2 Dimensions in Full-Scale.

LED NAVIGATION LIGHTS More Light. Less Energy. 3 High reliability and compact design of the new navigation lights allow their installation on professional boats over 50 meters. For professional shipping long lifetime and low maintenance costs are essential. In comparison to traditional techniques available on the market, our newly designed bicolor side lights have remarkable advantages. Thus, energy consumption is reduced from 25 to 1,6 Watts. Furthermore, the lifetime of the new lights is much longer than the one of navigation lights existing on the market. Very high quality material, such as seawater proof aluminum and stainless steel is used to produce our LED-navigation lights. Weather resistant lenses made of boron glass guarantee longterm transparency. Extensive endurance tests have confirmed functionality and persistence of the LED navigation lights also under adverse seawater conditions. Due to high performance LED, our navigation lights develop nautical reach of over two or three nautical miles, the masthead-light even over five or six nautical miles respectively. Classification The Böning LED navigation lights are certified and approved by the German Federal Maritime and Hydrographic Agency in accordance to the EU regulations. 0735 APEX Certification Böning LED Navigation lights are now also available as an explosion protected version for Zones 2 and 22. Our LED Navigation lights combine excellent technical characteristics with noble design. They are available in five versions: Standard White Classical Base Seawater resistant aluminum with hard Elox coating, much harder and seawater resistant than the traditional one Identical to standard version, with powder coating for additional protection Polished brass housing for fans of beautiful classical design and traditional materials Standard version with a square base for direct installation on horizontal surfaces Double lanterns for vessels over 50 meters are also available.

4 Lights for Vessels up to 50 m. Type Weight (g) Power Consumption (W) Visibility (NM) Diameter/Height (mm) Voltage (V DC) Port 330 1.0 2 64 /54 12 / 24 Starboard 330 1.2 2 64 /54 12 / 24 Stern 330 1.0 2 64 /54 12 / 24 Towing yellow 330 1.3 2 64 /54 12 / 24 Masthead 3 NM 350 1.8 3 64 /54 12 / 24 Masthead 5 NM 370 5.0 5 64 / 54 24 White all-around 300 1.5 2 64 / 54 12 / 24 Red all-around 300 1.9 2 64 / 54 12 / 24 Green all-around 300 1.8 2 64 / 54 12 / 24 Yellow all-around 300 1.9 2 64 / 54 12 / 24 Bicolor* 330 1.6 2 64 /54 12 / 24 Tricolor* 330 2.4 2 64 /54 12 / 24 Tricolor/Anchor* 350 1.5 / 2.4 2 64 / 54 12 / 24 Versions: Standard (x=0), White (x=1), Base (x=3), Classical (x=5) The Base Version is 11 mm higher and 170 g heavier. * max. vessel length 20 m

LED NAVIGATION LIGHTS Lights for Vessels over 50 m. 5 Type Weight (g) Power Consumption (W) Visibility (NM) Diameter/Height (mm) Voltage (V DC) Port 330 1.9 3 64 /54 12 / 24 Starboard 330 2.0 3 64 /54 12 / 24 Stern 330 1.7 3 64 /54 12 / 24 Towing yellow 330 2.1 3 64 /54 12 / 24 Masthead 6 NM 510 9.8 6 64 / 54 24 White all-around 300 2.9 3 64 / 54 24 Red all-around 300 3.3 3 64 / 54 24 Green all-around 300 3.2 3 64 / 54 24 Yellow all-around 300 3.4 3 64 / 54 24 Anchor manoeuvre 300 4.5 5 64 / 54 24 Versions: Standard (x=0), White (x=1), Base (x=3), Classical (x=5) The Base Version is 11 mm higher and 170 g heavier.

6 Double Lights for Vessels over 50 m. Type Weight (g) Power Consumption (W) Visibility (NM) Diameter/Height (mm) Voltage (V DC) Port 330 1.9 3 64 /83 12 / 24 Starboard 330 2.0 3 64 /83 12 / 24 Stern 330 1.7 3 64 /83 12 / 24 Towing yellow 330 2.1 3 64 /83 12 / 24 Masthead 6 NM 510 9.8 6 64 / 116 24 White all-around 300 2.9 3 64 / 63 24 Red all-around 300 3.3 3 64 / 63 24 Green all-around 300 3.2 3 64 / 63 24 Yellow all-around 300 3.4 3 64 / 63 24 Texts and illustrations in this brochure are non-binding. Changes may be made due to technical improvements. 2016 Böning Automationstechnologie GmbH & Co. KG

LED NAVIGATION LIGHTS Accessories for LED Lights. 7 Lamp holder bow/stern Lamp holder starboard side Lamp holder port side Lamp holder mast Lamp holder top Lamp holder mast-combi LED spotlight matching lamp holder mast-combi 10 beam angle 22 beam angle 40 beam angle Mast-combi protection Holder wind indicator

8 Monitoring and Control Systems for Navigation Lights The modular AHD-DPS 02 controls and monitors up to 42 navigation and signal lanterns on board vessels. Due to its modular structure, the system can be matched to customer specific requirements. It is comprised of one basic module and up to 4 extension modules as well as a customer specific operation panel. The system is available in different versions for all customary voltages on board vessels, and it can be used with conventional or LED lanterns. The minimum configuration encompasses a basic module for 14 lanterns and a standard operation panel. By using additional basic modules, any number of lanterns can be controlled and monitored. The lanterns are controlled with an operation panel, which provides one operation button and one LED status light for each lamp circuit. Depending on the requirements, the operation panels can be delivered in their standard size or according to the customer s wishes. Additional operation options for touch screen or panel PC are also available. The lamp current is provided either by the main feed or a second, separate feed (emergency feed). If one of these power feeds fails, it can be manually switched over to the other. Both currents are continuously monitored. The internal electronics are automatically supplied by one of the available power sources. If one lamp channel is switched off, both switch contacts are disconnected from the power supply with a relay. The lamp outputs are short-circuit proof and maintenance free. The lanterns can be controlled manually during electronics failure. A collective alarm (closed) contact reports current error conditions to a higher ranking alarm system. The CAN bus or Modbus enables connection to ancillary systems for convenient control and visualization.

LED NAVIGATION LIGHTS 9 AHD-DPS 02 G14 item-no. 13831 14 Channel Basic Module for Navigation and Signal Lights Control (24 V LED) The basic module for controlling and monitoring navigation and signal lamps has been constructed for 14 lamp circuits, which can be controlled and monitored independently; lamp failures, short-circuits, or wire breaks are alerted; in addition, operating time monitoring and end-of-life warning (t < 2000 h) can be parametered for each lamp circuit. The system includes a dual power supply, which switches over to the emergency feed in case of main feed failure. Both feeds are also monitored. Additional features: Direct switching of the lamps is possible even in case of electronics failure All switch channels are short-circuit proof, automatic reset fuses enable maintenance and exchange-free operation The system can be expanded to up to 42 lamp circuits with the extension modules AHD-DPS 02 A07 Optional communication modules AHD-DPS 02 GC (RS-422, RS-485, CAN) available on request Electronics unit for 24 V incandescent lamps (bulbs) in carrier rail housing, suitable for carrier rail mounting (TS32/35). Alternate versions for: 24 V incandescent bulbs (item-no. 13828) 230 V incandescent bulbs (item-no. 14678) 230 V LED lamps (item-no. 14679) 115 V incandescent bulbs (item-no. 13830) 115 V LED lamps (item-no. 15113) AHD-DPS 02 G14 1 x optocoupler input Inputs (Alarm acknowledgment) 14 x relay output (2 poles, for lamps) Outputs 3 x relay contact status signals (Common alarm, supply error, lamp error) 1 x connection for operation unit Combined (ribbon cable), inputs / outputs 1 x connection for max. 4 extension modules (ribbon cable) 1 x CAN (galvanically isolated), optional communication module Interfaces AHD-DPS 02 GC for RS-232, RS-485 or CAN Power supply 24 V DC (+30% / -25%) Current consumption 420 ma @ 24 V DC Dimensions (W x H x D) 324 mm x 126 mm x 76 mm Degree of Protection IP 20 Weight approx. 1.05 kg Operation temperature -30 C +70 C Storage temperature -50 C +85 C Approvals DNV GL, LR, RMRS, CRS, BV AHD-DPS 02 A07 item-no. 12157 7 Channel Extension Module (24 V LED) Extension module for 7 lamp circuits to expand an existing basic module for monitoring and controlling navigation and signal lamps. Every system can be expanded with up to 4 extension modules to a maximum of 42 lamp circuits. Alternate versions available for several lamps and voltages

10 AHD-DPS 02 B14 item-no. 11414 Control Panel for Navigation and Signal Light Systems Operating panel for navigation and signal lamp monitoring AHD-DPS 02 G14 for controlling 14 lamp circuits. Compact design for installation in consoles, panels, and switch control boxes Individual ON/OFF operating keys for 14 navigation and signal lamps Integrated signal LEDs for displaying lamp status, lamp fault, supply fault, and system failure Additional warning indicator for the lamps rest-of-life (2,000 hours remaining) All signal LEDs are automatically dimmed Integrated alarm buzzer and acknowledge key with lamp test function Optional switch for releasing an existing remote control (via Basic Module AHD-DPS 02 G14 s CAN port) Device for console installation or flush mounting. Alternate versions: AHD-DPS 02 B21 with 21 channels (item-no. 11481) AHD-DPS 02 B28 with 28 channels (item-no. 12521) AHD-DPS 02 B35 with 35 channels (item-no. 12522) AHD-DPS 02 B42 with 42 channels (item-no. 12382) AHD-DPS 02 B14 Combined 1 x connection to basic inputs / outputs module (ribbon cable) Power supply 24 V DC (+30% / -25%) Current consumption 400 ma @ 24 V DC Dimensions (W x H x D) 150 mm x 150 mm x 80 mm IP 22 (front side with Degree of Protection protection cover IP 54) Weight approx. 0.5 kg Operation temperature -30 C +70 C Storage temperature -50 C +85 C Approvals DNV GL, LR, RMRS, CRS, BV Device for installation in consoles or switch boards. Versions: with front frame 150 mm x 150 mm (item-no. 10945) with front frame 294 mm x 150 mm (item-no. 11061) AHD-DPS 02 BS Customer Specific Control Panel For controlling our navigation and signal lamp monitoring system AHD-DPS 02 G14. Identical technical qualities and options as standard operating panel (see AHD-DPS 02 B14, item-no. 11414 or variant). Lamp control elements and labels are arranged individually, according to tabular or graphic templates. Depending on the application and number of lamp channels to be controlled, various sizes are available. AHD-DPS 02 BS 1 x connection to basic module, Outputs up to 4 connections to extension modules Power supply 24 V DC (+30% / -25%) Current consumption 400/600/800 ma @ 24 V DC Dimensions (W x H x D) 150/294 mm x 150 mm x 80 mm Degree of Protection IP 22 (front side with protection cover IP 54) Weight approx. 0.5 kg / 0.7 kg / 0.9 kg Operation temperature -30 C +70 C Storage temperature -50 C +85 C Approvals DNV GL, LR, RMRS, CRS, BV

Monitoring and Control System Example 11 LED NAVIGATION LIGHTS

www.boening.com Headquarters in Ganderkesee, Germany Branches in the U.S.A., Brazil, Italy, Spain, and Croatia Sales and Service Partners For a list of our partners, please visit our website www.boening.com V 2.0 2016-08 ScMi Böning Automationstechnologie GmbH & Co. KG Am Steenöver 4 27777 Ganderkesee Germany Phone: +49 4221 9475 0 Fax: +49 4221 9475 22 Email: info@boening.com