Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Similar documents
Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Output signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power supply DC V, ±10%, 0.3 W

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

DPA+ LCD. Application. Types Available. Differential Pressure Transmitter. Datasheet

Functional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Duct humidity and temperature sensor for all HVAC duct applications. Designed for control and monitoring applications.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

Application. Types Available. Duct sensor for air quality, temperature and humidity (optional) Datasheet

Functional data Position indication reflective visual indicator (snap on) Communicative control Cloud: (call for clientapi )

DP DP2500 DP0250

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Overview of types. Technical data

Technical data sheet. Technical data

thanos RS485 Modbus Application Functions Multifunction Room Operating Unit Datasheet

Technical data. Safety notes. Product features

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Power consumption In operation At rest For wire sizing

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Airflow Pressure Sensor

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

InReg Volume flow controller Pa

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Differential pressure sensor For ventilation and air-conditioning Model A2G-50

Dual differential pressure sensor For ventilation and air-conditioning Model A2G-52

Technical data sheets

Multi-range pressure and differential pressure transmitter

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

InBin-P Pressure switches from 5 Pa Pa

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

Table of Contents. General Information. Document Sure-Aire Flow Monitoring System. User and Service Manual WARNING CAUTION

Specification Sheet For electronically commutated motors

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

InCos-P Pressure sensor 20 Pa Pa

Technical data sheet

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Functional data Factory settings Variable Setting Torque Inhibiting torque

RXTP ROOM TEMPERATURE

ECON-ZIP-BASE. ZIP Economizer Base Module

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

EE210. Humidity and Temperature Transmitter for Demanding Climate Control. Applications. Features. 36 v2.5 / Modification rights reserved EE210

FXVMA Variable Air Volume (VAV) Box Controller

THERMOSTATS & CONTROLLERS

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

PTU300 Combined Pressure, Humidity and Temperature Transmitter

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

PCD DIGITAL Differential pressure probe

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

s Spring return C / max C

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Please Read Instruction Carefully Before Installation! Figure 1: A/CO2-DUCT

RXTH DUAL ROOM SENSOR / SWITCH

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Products no longer available

Sensor for car parks and tunnels

ECLYPSE Communication Modules

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Relative, and differential pressure transmitter type 699

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Temperature controller Ducted systems

Digital electropneumatic Positioner SideControl

Pressure range mbar / mbar

Digital electropneumatic positioner

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

DIFFERENTIAL PRESSURE TRANSMITTER with MODBUS interface Optional Input module

Gas Controller System DGC-06

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

ECLYPSE Communication Modules

Compact universal controllers

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Fast Route to Reliable Energy Savings ZIP Economizer

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Control equipment EMBL

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

VAV compact controller GDB181.1E/3 GLB181.1E/3

Millenium II +: general characteristics

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Transcription:

Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the differential pressure of air and other non-flammable and nonaggressive gases. Monitoring air filters, fans, industrial cooling air cycles, control of air and fire dampers. Type Overview Type Measuring Range Pressure Output Signal Output Signal Active Pressure Output signal active volumetric flow Overpressure Limit Display Type 22ADP-556 - Modbus DC 0...5 V, DC 0...5 V, 40 kpa / 160 inch WC - 22ADP-556L - Modbus DC 0...5 V, DC 0...5 V, 40 kpa / 160 inch WC LCD Technical Data Electrical Data Power Supply DC 15...24 V, ±10%, 1.4 W Power Supply AC Electrical Connection Cable Entry 24 V, ±10%, 2 VA removable spring loaded terminal block max. 11 GA [2.5 mm²] cable gland M20 2 x Ø6 mm, with strain relief 2 x Ø6 mm, 1/2" conduit adapter included Functional Data Sensor Technology piezo measuring element Communicative Control Multirange Output Signal Active Note Display Media Modbus RTU (for details see separate document "Sensor Modbus Register") 8 fields selectable output DC 0 to 5/10 V selectable with switch voltage output: min. 10 kω load current output: max. 500 Ω load LCD, 1.14" x 1.38" [29 x 35 mm] with backlight measured values: Pa, inchwc (configurable) measured values volumetric flow: m³/h, cfm (configurable) air www.belimo.com en-us 2018-08-07 Subject to change 1 / 5

Measuring Data Measured Values differential pressure Measuring media air and non-aggressive gases Measuring range settings pressure Setting range [Pa] range [inch WC] Factory setting S0 0...7000 0...28 S1 0...5000 0...20 S2 0...4000 0...16 S3 0...3000 0...12 S4 0...2500 0...10 S5 0...2000 0...8 S6 0...1500 0...6 S7 0...1000 0...4 Accuracy Pressure Materials Cable Gland PA6, black measuring range 8 inch WC (2000 Pa): ±0.04 inch WC (±10 Pa) measuring range >8 inch WC (2000 Pa): ±0.1 inch WC (±25 Pa) Housing cover: lexan, Belimo orange NCS S0580- Y6OR base: lexan, Belimo orange NCS S0580- Y6OR seal: 0467 NBR70, black Safety Data Ambient Humidity max. 95% RH non-condensing Ambient Temperature Medium Temperature Protection Class IEC/EN Protection Class UL EU Conformity 15 F to 120 F [-10 C to 50 C] 15 F to 120 F [-10 C to 50 C] III safety extra-low voltage (selv) UL Class 2 Supply CE Marking Certification IEC/EN IEC/EN 60730-1 and IEC/EN 60730-2-6 Certification UL Degree of Protection IEC/EN Degree of Protection NEMA/ UL culus acc. to UL60730-1A/-2-6, CAN/CSA E60730-1:02, CE acc. to 2004/108/EC and 2006/95/EC, NEMA 4X, IP65, UL Enclosure Type 4X IP65 NEMA 4X Quality Standard ISO 9001 Weight 0.29 lbs Safety Notes The installation and assembly of electrical equipment should only be performed by authorized personnel. The product should only be used for the intended application. Unauthorized modifications are prohibited! The product must not be used in relation with any equipment that in case of a failure may threaten, directly or indirectly, human health or life or result in danger to human beings, animals or assets. Ensure all power is disconnected before installing. Do not connect to live/operating equipment. Please comply with Local laws, health & safety regulations, technical standards and regulations Condition of the device at the time of installation, to ensure safe installation This data sheet and installation manual www.belimo.com en-us 2018-08-07 Subject to change 2 / 5

Remarks Manual Zero-Point Calibration In normal operation zero-point calibration should be executed every 12 months. Attention! For executing zero point calibration the power supply must be connected one hour before. Release both connection tubes from the pressure terminals + and - Press the button S1 until the LED lights permanently Wait until the LED flashes again and reinstall the connection tubes to the pressure ports (note + and -) Accessories Scope of Delivery mounting plate dowel screws strain relief Ø6 to 8 mm cable gland nut conduit 1/2" NPT, 2 x Ø6 mm cable gland nut PG11, Ø6 to 10 mm cable gland nut conduit 1/2" NPT Optional Accessories Description Type metal duct connectors 1.57" [40 mm] metal duct connectors 4" [100 mm] A-22AP-A01 A-22AP-A03 www.belimo.com en-us 2018-08-07 Subject to change 3 / 5

Wiring Diagram 1 Button 2 red: Error 3 yellow: Tx 4 yellow: Rx 5 and 6 Status LED * Factory setting P Pressure unit T Response time U Output signal Detailed documentation Notes Wiring RS485 Wiring RS485 (Modbus RTU & BACnet MS/ TP) Setting range [Pa] range [inch WC] Factory setting S0 0...7000 0...28 S1 0...5000 0...20 S2 0...4000 0...16 S3 0...3000 0...12 S4 0...2500 0...10 S5 0...2000 0...8 S6 0...1500 0...6 S7 0...1000 0...4 The separate document Sensor Modbus-Register informs about Modbus register, addressing, parity and bus termination (DIP1: address, DIP2: baud rate, parity, bus termination) In addition to the information on the bus, the following analog outputs are available: AOU1: differential pressure AOU2: volumetric flow The volumetric flow is calculated from the differential pressure, the k-factor and the height Factory setting for the k-factor is 1.00 and for the height 330 metres above sea level. The values of the k-factor and the height can be changed via Modbus or BACnet. Connection via safety isolating transformer. Parallel power connection of additional actuators is possible. Observe the transformer size and performance data. The wiring of the line for BACnet MS/TP / Modbus RTU is to be carried out in accordance with applicable RS485 regulations. Modbus / BACnet: Supply and communication are not galvanically isolated. Connect earth signal of the devices with one another. www.belimo.com en-us 2018-08-07 Subject to change 4 / 5

Dimensions www.belimo.com en-us 2018-08-07 Subject to change 5 / 5