MMI6070 Quick Start Guide

Similar documents
FSA-CU Configuration Utility Programming Guide

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

Starter Guide Version Sphinx Access Control System

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

DIABLOSPORT PREDATOR REVISION UPDATE INSTRUCTIONS

Appendix A Cable Pinouts

Cable Pinouts. SRP I/O Module

F1000 User's Manual. (Version: V1.01)

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

Title: Using the AUX Port.

Connector and Cable Specifications

Title: Using the AUX Port.

Getting started with your DGH module:

USER MANUAL. S3MBW HDMI Multi-format Extender Over CAT5e/CAT6. Back View. Front View. Covid Part Numbers

3.1 I-7560 Pin Assignment and Specifications: Introduction

RTU560 Remote Terminal Unit Connections and Settings

ADC REVISION HISTORY INTRODUCTION INSTRUCTIONS CABLE REQUIREMENTS

Installation Instructions for: Channel Thermocouple Amplifier

USER MANUAL FOR GS100/GS1003G

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Product Manual. Mini USB to Terminal RS422 RS485 FTDI Plug-in Adapter. Coolgear, Inc. Version 1.1 April 2018 Model Number: USBG-422MiNi

1. Safety Precautions (Read these precautions before use.)

Bluetooth RS-232 Dongle. User s Manual BTS-100

UPort 1200/1400/1600 Quick Installation Guide

Mini USB to RS-232 Serial Adapter DB-9 Male Converter. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MINI.

WiFi to RS-232 adapter user manual

721EX Access Controller Installation

UPort 1200/1400/1600 Quick Installation Guide

Bluetooth TO Serial CONVERTER E-P132-B

EZ Touchscreen CE Computer. User Manual

VS-626M5 Parameter Upload/Download Software User s Manual (Preliminary) 5/18/99

Robustel GoRugged M1000 USB Quick Guide

INTRODUCTION 2 FEATURES. 2 SPECIFICATIONS. 2 PIN ASSIGNMENT 2 DB-9 DB-25 CONVERSION TABLE. 2 DRIVER INSTALLATION QUICK GUIDE.. 2

FT232 Serial to USB Converter

MT8050iE series. Installation Instruction (1) (2)

SFU Connection Cables

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

IAI Corporation 1998, 1999, For Reference Only.

RS-422/485 PCIe Card

Rotator Genius Instruction Manual v1.3.3

RS-422/485 PCI Card User Manual Ver All brand names and trademarks are properties of their respective owners.

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

This is the procedure to use the Clone module as a serial converter: To enable communication you must set the following parameters in the drive.

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

SitePORTAL Lite TA-SPL32-R48

Installing PRO/DGX or Pro Soloist MIDI interface. R Grieb 9/08/2017

USB-Link 2 Technical Guide

ESPSX3 Ethernet Serial Port Server X 3 Users Guide

1. Safety Precautions (Read these precautions before use.)

Product Specification. Shuttle XPC Accessory. COM / LPT / RJ11 port expansion for Shuttle XPC aio X50V4/V5/V6. Feature Highlight

Supplement for module D061 incl. ATMega128 Prozessor

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

D8000 SERIES QUICK START GUIDE

QuVIS CONNECTOR PINOUT GUIDE

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

1.6inch SPI Module user manual

TH E FI N EST I N G E E K E NTE RTAI N M E NT

AUTOLOG GSM-PLC STEP BY STEP

User Manual. cmt-svr Startup Guide

CTVUE Application Note

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

Configuration Instructions for icap with DOS Captivator

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

CS121 AUX Adapter for AS 400 UPS interface CS 121 AUX RJ11 6-pol Layout:

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

6 foot USB to RS-232 Serial Adapter DB-9 Male, FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MM

RTU560 Connections and Settings DIN Rail RTU 560CIG10

PenMount 9084 Setup and Users Manu

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651)

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM

FTC200 & FTA/FTX Quick Installation & Jumper Setting Guide

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Alarm Distribution Shelf (ADS)

PMDX-411 SmartBOB-USB with DB-25 Connector For use with Mach4

Data Acquisition. CM 7000 Series. Family of Bus Converter & Repeaters

Accessories - Cables

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

IntesisBox Modbus Server - Honeywell XLS 80

Smith Converter Box Installation

Powered RS Port PCIe Card

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

USB Port USB Serial DB-9 RS-232 Adapter FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

PORT MULTIPLEXER USER S MANUAL

Weight ounces Panel Fasteners... Four holes to accept four 16x32 machine screws NEMA Rating... NEMA 1

8051 Intermidiate Development Board. Product Manual. Contents. 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help

APPLICATION NOTE IDM.011

TC-UR24. USB to Serial port Adapter

ES-511, ES-522, ES-551, ES-571. Quick Start Guide. for Brainboxes Ethernet to Serial Range

USER MANUAL FOR FIOA-0402-U-16

Dwarf Boards. DN001 : introduction, overview and reference

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

RS-232 to RS-422/485 Converter with 3KV Isolation Protection

PCI Express 16-Port Serial I/O Cards

Phi-panel backpack assembly and keypad options Dr. John Liu 12/16/2012

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter

Transcription:

MMI6070 Quick Start Guide Introduction If at any time more information is required on HMI safety and protection ratings, HMI Power, and HMI communication, please refer to the MMI6070 Installation Guide provided at the following link: http://www.tri-plc.com/documents/mmi6070-install-instructions.pdf The following is only the minimum basic information required to get the MMI6070 set up with TRI PLCs in most situations. 1. Connect HMI to PC and PLC Your MMI6070 comes with a USB cable to connect the HMI to your PC and a standard DB9 serial cable for RS232 connection to your TRi PLC (If the HMI is purchased as a bundle with the PLC, otherwise the DB9 cable can be purchased separately). An RS485 connection cable is not provided, but it is possible to make a 2-wire RS485 connection between the PLC and HMI by modifying the standard DB9 cable, or by building a custom cable. Getting Connected: 1. Connect the mini-usb end of the USB cable to the MMI6070 and the standard USB end of the cable to one of your PCs USB ports. For RS232 connection. 2. Connect the female end of the standard 9-pin RS232 serial cable to the male DB9 connector on the MMI6070. 3. Connect the male end of the DB9 cable to the female connector on the PLC. Figure 1: RS232 connection between MMI6070 and TRi PLC

For RS485 connection. 2. Connect the male end of the standard 9-pin RS232 serial cable to the female DB9 connector on the MMI6070. 3. The Nano-10 does not have an RS232 port, so the DB9 cable supplied with the MMI6070 must be modified or a custom cable must be built in order to interface the Nano-10 (or any TRi PLC RS485 port) to the HMI. Refer to Figure 2 below when creating/modifying the cable. Figure 2: RS485 connection between MMI6070 and TRi PLC a. Follow the pinout for the Female HMI connector table below to connect two wires (data + and data -) between the PLC and HMI. b. The male end of the DB9 cable connects to the HMI and the female end is to be removed (cut the ribbon cable at the base of the connector) so that the ribbon cable can be stripped and the two signal wires can be connected to the RS485 terminal on the PLC. c. We recommend terminating wires with ferrules for better connection to the RS485 screw terminal. d. Alternatively, you can create a custom cable that is DB9 male terminated on one end and twisted pair (two wires) with terminal plugs on the other end.

Here are tables showing the RS232 and RS485 pin connections between the MMI6070 and all TRI PLCs (excluding the H-series and E-series PLCs) in case a custom cable is being built: HMI Male DB9 Connector Pin # Symbol HMI COM 1 [RS232] PLC Female DB9 Connector [RS232] 2 RxD Received Data Transmitted Data 3 TxD Transmitted Data Received Data 5 GND Signal Ground Signal Ground Note: If you are using the Nano-10, there is no RS232 port and the RS485 port is actually considered COM1 in the PLC. See step 4 in Getting Connected for connection instructions. HMI Female DB9 Connector Pin # Symbol HMI COM 1 [RS485] PLC 2-Wire Screw Terminal [RS485] 1 Rx- Data- Data- 2 Rx+ Data+ Data+ 5 GND Signal Ground Signal Ground 2. Connect Power to HMI and PLC The MMI6070 has 3 connections for power: +, -, and. A 24VDC power supply should be used, which can be the same supply used for the PLC. Power should be connected to the MMI6070 as follows : 1. Connect the +24VDC terminal from the power supply to the + terminal on the HMI. 2. Connect the 0VDC (-) terminal from the power supply to the - terminal on the HMI. 3. The can generally be left unused, but the installation guide should be referenced if you are unsure. Power should be connected to the PLC as follows : 1. Connect the +24VDC terminal from the power supply to the +24V terminal on the PLC. 2. Connect the 0VDC (-) terminal from the power supply to the 0V terminal on the PLC. 3. Reference the PLC documentation for more information on this.

3. Install and Run EB8000 HMI Software You will have received a small CD labelled: Easy Builder 8000 Installation CD. You should install the EB8000 software from the CD on your PC, which will include the necessary drivers for compatible TRI PLCs. If the software does not install right away, you can execute the EB8000_V4.51.msi file that is located in the main folder of the CD. Then follow the steps to install the software. Once the software has installed you can start EB8000 from the start menu or desktop icon on your PC. You should then see something similar to the following picture: Figure 3: EB8000 Screen 4. Load and Transfer HMI Sample Program The sample program included with this quick start guide is called triplcdemo.mtp. You can open this file from Easy Builder 8000 using File Open and selecting the location that triplcdemo.mtp is saved to. This sample program is already pre-configured for communication with a TRI PLC via RS485, since all of the compatible TRI PLCs have one or more RS485 ports. Once you have opened the sample program, you can transfer it to the HMI as follows : 1. Go to the Tools menu and select Compile. 2. A new window should appear, click on Compile. 3. You should see Succeeded highlighted if it worked. You can close the window. 4. Go to the Tools menu and select Download. A new window should appear. 5. Make sure that USB Cable, Firmware, and Reboot HMI after Download are all selected as shown in Figure 2. 6. Click download and wait for the message that the download has finished.

NOTE: The Firmware box typically only needs to be checked the first time a program is being transferred to the HMI or if any COM settings have changed or if there is a firmware update being installed to the HMI. Figure 4: Download Window 5. Load and Transfer PLC Sample Program A Trilogi PLC sample program, called MMI6070.PC6, is also included in the MMI6070doc.zip file. This should be opened with Trilogi and transferred as normally done with Trilogi (and TLServer for serial connections). You can find more information on communicating with a PLC using Trilogi from the TL6 Programmers Reference Manual. The MMI6070.PC6 sample program is only required for the LCD and PWM functions included in the MMI6070_TRI_PLC.mtp sample program. It could be modified to do more such as update the LCD periodically instead of only once. 6. Using the MMI6070 Sample Program Now that the MMI6070_TRI_PLC.mtp sample program has been loaded in the HMI, you should see the Home screen for this program : Figure 5: Home Screen

You can traverse through the different screens in the sample program by clicking on Next Page to go forward one page or Last Page to go backward one page. You can also access Help for each page by clicking on the? button, which will open up a new screen with some information and tips. There are 4 screens total as shown in Figures 4-7 below. Figure 6: I/O Screen Figure 7: Analog Screen Figure 8: PWM Screen Figure 9: LCD Screen 7. Start a New Program and Configure for a TRI PLC When you start a new program you will be asked to select your HMI model and screen orientation. You should select the MMI6070 (800 x 480) model and Landscape as per the following screenshot : Figure 10: Select Model Once you select OK, you will see a screen like Figure 9 below that allows you to configure the MMI settings for your current project. As shown below, the MMI6070 should be in the device list. Next you will need to add a PLC to the device list by selecting New, which will open up a new window called Device Properties as shown in Figure 10. The following settings should be selected, as shown in Figure 10 :

Name: Anything (TRI_PLC was assigned automatically after selecting PLC type) PLC should be selected, not HMI Location: Local because it is a serial connection PLC type: TRI_PLC this is the communication driver for TRI PLCs. PLC I/F: RS-232 or RS-485 depending on how you want to connect to the PLC. PLC default station no.: 1 this is the default PLC ID COM: COM1 (38400, N, 8, 1) these are the default com settings in the PLC Everything else can be left as the default. Figure 12: Add/Configure PLC Figure 11: Configure HMI Once you click OK, you should see the PLC in the device list below the MMI6070. There are other tabs you can select to modify additional parameters in the HMI for this project, but nothing that is required. The General and System Setting tabs contain settings that are most likely to be useful. Then you can click OK on the Device Properties window and you should see a starting screen similar to Figure 11.

Figure 13: New Program Window Now you can add windows and fill them with data input and display objects as well general text and pictures. You can find more information on configuring the program for an MMI6070 with a TRI PLC as well as information on PLC data mapping between the PLC and HMI in the TRI_Setup pdf document included in the MMI6070doc.zip package. The Help menu in EB8000 also has a lot of information on the available components that will help to design your touch screen program.