ETT 412 Touch Operating Panel Technical Manual

Similar documents
ETT 312 Build-In Touch Terminal

ETT 352 Touch Operating Panel

HZS 352 Touch Room Unit

HZS 351 Room Touch Control Panel

ICA 012 S-DIAS Interface Module CAN

ISE 021 S-DIAS Interface Module RS232 / RS485

RO 051 S-DIAS Relay Output Module

TO 161 S-DIAS Digital Output Module

AO 081 S-DIAS Analog Output Module

SI 021 S-DIAS SSI Interface Module

KL 181 S-DIAS +24 V Potential Distributor Module

SE 051 S-DIAS Splitter Ethernet

DM 161 S-DIAS Digital Mixed Module

PS 101 S-DIAS Power Supply Module

VI 021 S-DIAS VARAN Control Module

TAE 1921 Touch Display Unit

PC 521 Data Recording PC

AI 046 S-DIAS Analog Input Module

SSI 021 S-DIAS Safety SSI Absolute Value Encoder

DC S-DIAS Axis Module

MDM 011-Z1 Regen Resistor

HZS Internal Controller Expansion

TSY 041 Training System Extension Motion

TAE 1921 Touch Display Unit

ControlLogix Redundant Power Supply Chassis Adapter Module

LVB-2 INSTRUCTION SHEET. Leakage Current Verification Box

C-DIAS Digital Input Module CDI 161 with 16 inputs

VARAN Splitter Module VSV 043

Expansion Module HZS 541-1S

VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems

PC 400 Control Cabinet PC

IPCB42501 / IPCB42551

TETRIS 2500 High Impedance Active Probe. Instruction Manual

Installation manual plugs and connectors with screw connection (16/32 A)

STO 081 S-DIAS Safety Digital Output Module

Installation- and Operating instructions for CU Port USB 2.0 Hub. Version: 1.3 Date:

UV Power Flood. User Manual. Order code: EQLED029

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

VARAN Splitter PROFINET VSP 042

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Speed monitor D / / 2014

Blitzer Strobe. User Manual. Order code: EQLED366

Installation- and Operating instructions for CU Port USB 3.0 Hub. Version: 1.1 Date:

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

RGB Power Batten. User Manual. Order code: EQLED032

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

User Manual HMI Linkbox HL01 DP/MPI

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

LED W RGBA User Manual

Connection Cables for Operating Devices

C-DIAS Analogue Output Module CAO 082 for eight ±10V DC respectively eight 0 20mA DC outputs

Slimline CW & WW Series

Type ME43. Quickstart

Technical Data Sheet OPUS A3 STANDARD Basic

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

F1000 User's Manual. (Version: V1.01)

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

PF LED Profile. User Manual

C-DIAS Serial Interface CSI 021

Controller Specifications

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Gobo Projector XP 80W

SIWAREX JB Aluminum Housing. Instruction Manual Edition 03/2006

CS2 DMX Distribution Splitter

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

HD40H(X) Performance Series Camera. User Guide

MC 11 EB-2 Power supply cabinet with external bus, AC version

Vector Beam White. User Manual. Order code: LEDJ265

ZF LED Zoom Fresnel. User Manual

CPCI-PS24 24V-Power Supply

ETAM3 XETK/FETK ECU Adapter, SAMTEC FFSD - SAMTEC SFM (10fc - 10fc), 0m11 User s Guide

FL MC 2000E (SM40) LC

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

MU110-6U. Analog output module 6 channel. User guide

LIGHT BRICK - 12 X 3W TRI-COLOUR

C-DIAS Analog Module CAO 086 For eight ±10 V Outputs

CMC III Universal Sensor

HZS Solar Module

PanelView Plus/VersaView CE Terminals and Display Modules

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

About this Document 2 Symbols and Typographic Conventions... 2 Figures... 2 Downloading Manuals... 2

Microbar COB System. User Manual. Order code: EQLED137

SCHOTT FLM 4 Fiber Lighting Modul. Operating Instructions

SEL-3421 Motor Relay HMI (With LCD) Quick-Start Guide

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Demonstration Case BENNING DB 1

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

VARAN Splitter Module VSV 041

PML 791-RO Low-Z Passive Probe. Instruction Manual

Transcription:

ETT 412 Touch Operating Panel Technical Manual Date of creation: 07.02.2019 Version date: 07.02.2019 Article number: 01-230-412-E

Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: +43/6274/4321 Fax: +43/6274/4321-18 Email: office@sigmatek.at WWW.SIGMATEK-AUTOMATION.COM Copyright 2019 SIGMATEK GmbH & Co KG Translation from German All rights reserved. No part of this work may be reproduced, edited using an electronic system, duplicated or distributed in any form (print, photocopy, microfilm or in any other process) without express permission. We reserve the right to make changes in the content without notice. SIGMATEK GmbH & Co KG is not responsible for technical or printing errors in this handbook and assumes no responsibility for damages that occur through its use.

BUILD-IN TOUCH TERMINAL ETT 412 Touch Operating Panel ETT 412 The ETT 412 is used to visualize automated processes. Process diagnostics as well as operating and monitoring automated procedures are simplified using this control. A projected capacitive touch screen serves as the input medium for process data and parameters. The output is shown on a 4.3" TFT color display. With the LSE mask editor, graphics can be created on the PC, then stored and displayed on the terminal. Data is exchanged with the CPU via the CAN bus. The display is constructed with a black anodized aluminum front. 07.02.2019 Page 1

ETT 412 BUILD-IN TOUCH TERMINAL Contents 1 Introduction... 4 1.1 Target Group/Purpose of this Manual... 4 1.2 Important Reference Documentation... 4 1.3 Contents of Delivery... 4 2 Basic Safety Guidelines... 5 2.1 Symbols Used... 5 2.2 Disclaimer... 6 2.3 General Safety Guidelines... 7 2.5 Guidelines... 8 2.5.1 EU Conformity Declaration... 8 3 Technical Data... 9 3.1 Performance Data... 9 3.2 Electrical Requirements... 9 3.3 Controller... 9 3.4 Display... 9 3.5 Environmental Conditions... 10 3.6 Miscellaneous... 10 4 Mechanical Dimensions...11 5 Connector Layout...12 5.1 X1: CAN bus 5-pin Phoenix RM 3.5... 12 5.2 X2: Supply (4-pin Phoenix RM 3.5)... 12 Page 2 07.02.2019

BUILD-IN TOUCH TERMINAL ETT 412 5.3 Protective Earth Connection... 13 5.4 Applicable Connectors... 14 6 Mounting Instructions... 15 6.1 Vertical Mounting Position... 16 7 CAN Bus Protocol... 16 8 CAN Bus Setup... 16 8.1 CAN Bus Station Number... 16 8.2 CAN Bus Data Transfer Rate... 17 9 CAN Bus Termination... 18 10 Cleaning the Touch Screen... 19 11 Transport/Storage... 20 12 Assembly/Installation... 21 12.1 Check List... 21 12.1.1 Check Contents of Delivery... 21 12.2 Maintenance... 21 12.3 Repair... 21 13 Disposal... 22 07.02.2019 Page 3

ETT 412 BUILD-IN TOUCH TERMINAL 1 Introduction 1.1 Target Group/Purpose of this Manual This manual contains all information required for operating the ETT 412-K. This manual is intended for: Project planners Technicians Configurators/commissioning engineers Machine operators Maintenance/test technicians General knowledge of automation technology is required. Further help and training information, as well as the appropriate accessories can be found on our website www.sigmatek-automation.com Our support team is happily available to answer your questions. For our support hotline and business hours, please visit our website. 1.2 Important Reference Documentation HW IP Address Setting documentation This document can be downloaded from our website or obtained through Support. 1.3 Contents of Delivery 1x ETT 412 1x opposing connector This document can be downloaded from our website. Additional documents may be included with delivery. Page 4 07.02.2019

BUILD-IN TOUCH TERMINAL ETT 412 2 Basic Safety Guidelines 2.1 Symbols Used The following symbols are used in the operator documentation for warning and danger messages, as well as informational notes: DANGER Identifies an immediate danger with high risk, which will lead to immediate death or serious injury if not avoided. Identifie un danger immédiat avec un risque élevé, entraînant le décès immédiat ou des blessures graves s il n est pas évité.. WARNING Identifies a possible danger with a mid-level risk, which can lead to death or (serious) injury if not avoided. Indique un danger possible d un risque moyen de décès ou de (graves) blessures si les consignes de sécurité ne sont pas respectées CAUTION Identifies a low risk danger, which can lead to injury or property damage if not avoided. Indique un danger avec un niveau de risque faible des blessures légères ou des dommages matériels si les consignes de sécurité ne sont pas respectées. Provides user tips, informs of special features and identifies especially important information in the text. Fournit des conseils d utilisation, informe sur les fonctions particulaires et souligne les informations particulièrement importantes dans le texte. 07.02.2019 Page 5

ETT 412 BUILD-IN TOUCH TERMINAL 2.2 Disclaimer The contents of this document were prepared with the greatest care. However, deviations cannot be ruled out. This document is regularly checked and required corrections are included in the subsequent versions. The machine manufacturer is responsible for the proper assembly, as well as device configuration. The machine operator is responsible for safe handling, as well as proper operation. The current document can be found on our website. If necessary, contact our support. Subject to technical changes, which improve the performance of the devices. The following documentation is purely a product description. It does not serve to guarantee properties under the warranty. Please thoroughly read the corresponding data sheets, operating instructions and this system handbook before handling a product. SIGMATEK GmbH & Co KG is not liable for damages caused through, non-compliance with these instructions or applicable regulations. The general and special safety instructions described in the following sections, as well as technical regulations, must therefore be observed. Page 6 07.02.2019

BUILD-IN TOUCH TERMINAL ETT 412 2.3 General Safety Guidelines Observe all on-site rules and regulations for accident prevention and occupational safety. According to EU guidelines, the operating instructions are a component of a product. This manual must therefore be accessible in the vicinity of the machine since it contains important instructions. This technical documentation should be included in the sale, rental or transfer of the product. Maintain this manual in readable condition and keep it accessible for reference. Operate the unit with devices and accessories approved by SIGMATEK only. CAUTION In addition, the Safety Guidelines in the other sections of these instructions must be observed. These instructions are visually emphasized by symbols. The module complies with EN 61131-2. In combination with a machine, the machine builder must comply with EN 60204-1 standards. For your own safety and that of others, compliance with the environmental conditions is essential. To perform maintenance or repairs, disconnect the system from the power supply. En outre, les consignes de sécurité mentionnées dans d autres sections de ce manuel doivent être respectées. Ces directives sont indiquées avec les symboles graphiques. Le module est conforme à la norme EN 61131-2. En combinaison avec une machine, le constructeur de la machine doit respecter la norme EN 60204-1. L armoire de commande doit être raccordée correctement à la terre. Pour l'entretien et les réparations, débranchez le système de l'alimentation. 07.02.2019 Page 7

ETT 412 BUILD-IN TOUCH TERMINAL 2.5 Guidelines The panel was constructed in compliance with European Union guidelines. 2.5.1 EU Conformity Declaration CE Declaration of Conformity The ETT 412 conforms to the following European guidelines: 2014/35/EU Low-voltage guideline 2014/30/EU Electromagnetic Compatibility (EMC guideline) 2011/65/EU Restricted use of certain hazardous substances in electrical and electronic equipment (RoHS Guideline) Page 8 07.02.2019

BUILD-IN TOUCH TERMINAL ETT 412 3 Technical Data 3.1 Performance Data Interfaces 1x CAN bus Data rate max. 1 Mbit/s 3.2 Electrical Requirements Supply voltage typically +24 V (+18-30 V DC) Current consumption at 24 V DC typically 75 ma maximum 130 ma Inrush current typically 0.8 A for 10 ms maximum 1.2 A for 20 ms 3.3 Controller Controller Internal data memory for visualization (SDRAM) Internal data memory for visualization (Flash) Cortex M3 8 Mbytes 8 Mbytes 3.4 Display Type 4.3" TFT LCD color display Resolution 480 x 272 Pixel size Number of pixels Active surface Color depth Backlighting 0.198 x 0.198 mm 480*3 (RGB) x 272 pixels 95.04 x 53.86 mm 24 bits 10x LED, white, adjustable Contrast 600:1 Touch Brightness projective capacitive typically 400 cd/m² Visible field left, right 80, above 70 and below 60 07.02.2019 Page 9

ETT 412 BUILD-IN TOUCH TERMINAL 3.5 Environmental Conditions Storage temperature -10... +70 C Environmental temperature 0... +55 C Humidity Installation altitude above sea level 10-90 %, non-condensing 0-2000 m without derating, > 2000 m with derating of the maximum environment temperature by 0.5 C per 100 m Operating conditions pollution degree 2 indoor use EMC resistance EMC noise generation in accordance with EN 61000-6-2 (industrial area) in accordance with EN 61000-6-4 (industrial area) Vibration resistance EN 60068-2-6 3.5 mm from 5-8.4 Hz 1 g from 8.4-150 Hz Shock resistance EN 60068-2-27 15 g Protection type EN 60529 front: IP54 Cover IP20 3.6 Miscellaneous Article number 01-230-412 Hardware version 1.x Standard CE Page 10 07.02.2019

BUILD-IN TOUCH TERMINAL ETT 412 4 Mechanical Dimensions Operating unit dimensions Control cabinet cutout Material Weight 132 x 94 x 35.5 mm (W x H x D) with opposing connector 145.0 x 107.0 x 35.5 mm (W x H x D) with opposing connector and mounting brackets 127 x 89 (W x H) (+/- 0.4 mm) front: 0.7 mm glass (touchscreen) in black anodized 3 mm aluminum frame Cover: 0.8 mm chromed sheet steel 0.3 kg 07.02.2019 Page 11

ETT 412 BUILD-IN TOUCH TERMINAL 5 Connector Layout 5.1 X1: CAN bus 5-pin Phoenix RM 3.5 Pin Signal Function 1 CAN A CAN LOW IN 2 CAN B CAN HIGH IN 3 CAN A CAN LOW OUT 4 CAN B CAN HIGH OUT 5 GND GND 5.2 X2: Supply (4-pin Phoenix RM 3.5) Pin Signal Function 1 +24 V Supply voltage 2 +24 V Supply voltage 3 GND GND 4 GND GND Page 12 07.02.2019

BUILD-IN TOUCH TERMINAL ETT 412 5.3 Protective Earth Connection The terminal must be grounded to protective earth via the M3 threaded bolts and the blade terminal, as well as to the control cabinet over a broad surface via the mount. It is important to establish a low-ohm connection to ground to ensure error-free function. The ground connection must be made with the maximum cross section and largest (electrical) surface possible. The cable length of the ground connection must also be kept as short as possible. 07.02.2019 Page 13

ETT 412 BUILD-IN TOUCH TERMINAL 5.4 Applicable Connectors Connectors: X1, X2: Connectors with spring terminals (included in delivery) Connections Stripping length/sleeve length: Mating direction: 10 mm Conductor cross section rigid: 0.2-1.5 mm 2 Conductor cross section flexible: 0.2-1.5 mm 2 conductor cross section strands ultrasonically compacted: 0.2-1.5 mm 2 Conductor cross section AWG/kcmil: 24-16 Conductor cross section flexible with ferrule: 0.25-1.5 mm 2 Conductor cross section flexible with ferrule and plastic sleeve: parallel to the conductor axis or circuit board 0.25-0.75 mm 2 (reason for reduction d2 of the ferrule) Page 14 07.02.2019

BUILD-IN TOUCH TERMINAL ETT 412 6 Mounting Instructions The build-in terminal is provided for mounting in a control cabinet wall. For mounting in the control cabinet wall, 8 angle clamps with threaded pins are provided. The front is therewith pressed against the outer control cabinet wall. The brackets are affixed using a flat head screwdriver with 0.2 Nm and therewith guarantee the necessary IP protection level for the front. The modules must be mounted vertically with sufficient clearance to nearby components and/or the control cabinet back wall. This is necessary for optimal cooling and air circulation, so that proper function up to the maximum operating temperature is ensured. CAUTION The terminal must be grounded to protective earth via the M3 threaded bolts and the blade terminal, as well as to the control cabinet over a broad surface via the mount. La borne doit être reliée à la terre par l'intermédiaire des boulons filetés M3 et de la borne à lame, ainsi qu'à l'armoire électrique sur une large surface via le support. 07.02.2019 Page 15

ETT 412 BUILD-IN TOUCH TERMINAL 6.1 Vertical Mounting Position 7 CAN Bus Protocol Display communication CAN object number: CAN bus object for receiving data: 0x020 + CAN bus station (0x00 0x1F) CAN bus object for sending data: 0x040 + CAN bus station (0x00 0x1F) 8 CAN Bus Setup This section explains how to configure a CAN bus correctly. The following parameters must first be set: Station number and data transfer rate. During start up the parameters can be set on the setup screen of the terminal. 8.1 CAN Bus Station Number Each CAN bus station is assigned its own station number. With this station number, data can be exchanged with other stations connected to the bus. Up to 31 stations can be installed in a CAN bus system. In a CAN bus system however, each station number can only be assigned once! Page 16 07.02.2019

BUILD-IN TOUCH TERMINAL ETT 412 8.2 CAN Bus Data Transfer Rate Various data transfer rates (baud rates) can be set on the CAN bus. The longer the bus line is, the lower the data transfer rate that must be selected. Value Baud rate maximum length 1 500 kbits/s 80 m 2 250 kbits/s 160 m 3 125 kbits/s 320 m 4 100 kbits/s 400 m 5 50 kbits/s 800 m 6 20 kbits/s 1200 m 7 1 Mbit/s 30 m These values apply to the following cable: 120, Twisted Pair. 07.02.2019 Page 17

ETT 412 BUILD-IN TOUCH TERMINAL 9 CAN Bus Termination In a CAN bus system, both end modules must be terminated. This is necessary to avoid transmission errors caused by reflections in the line. For the CAN bus a shielded connector cable must be used. The cable shielding must have a low-ohm connection to the ground. The line termination is provided by a 120 Ω resistor on the opposing connector between PIN 3 and PIN 4. Page 18 07.02.2019

10 Cleaning the Touch Screen BUILD-IN TOUCH TERMINAL ETT 412 WARNING Before cleaning the touch screen, the HGW must be turned off in order to prevent triggering functions or commands unintentionally! Avant de nettoyer l'écran tactile, le HGW doit être éteint afin d'éviter tout déclenchement involontaire de fonctions ou de commandes! The touch screen can only be cleaned with a soft, damp cloth. To dampen the cloth, a mild cleaning solution such as antistatic foam cleaner is recommended. To avoid fluids/cleaning solutions from getting into the housing, the device must not be sprayed directly. To clean, no corrosive cleaning solutions, chemicals, abrasive cleansers or hard objects that can scratch or damage the touch screen may be used. The use of steam jets or compressed air is prohibited. DANGER If the device is contaminated with toxic or corrosive chemicals, it must be carefully cleaned as quickly as possible to prevent personal injury and machine damage! i l'appareil est contaminé par des produits chimiques toxiques ou corrosifs, il doit être nettoyé avec soin le plus rapidement possible afin d'éviter des dommages corporels et matériels! To ensure the optimal function of the panel, the touch screen should be cleaned in regular intervals! To avoid damaging the touch screen, using either the fingers or a stylus to operate the panel is recommended. 07.02.2019 Page 19

ETT 412 BUILD-IN TOUCH TERMINAL 11 Transport/Storage This device contains sensitive electronics. During transport and storage, high mechanical stress must therefore be avoided. For storage and transport, the same values for humidity and vibration as for operation must be maintained! CAUTION TTemperature and humidity fluctuations may occur during transport. Ensure that no moisture condenses in or on the device. Pendant le transport, des fluctuations de température et d'humidité peuvent survenir. Veillez à ce qu'il n'y ait pas de condensation d'humidité dans ou sur l'appareil. Page 20 07.02.2019

BUILD-IN TOUCH TERMINAL ETT 412 12 Assembly/Installation 12.1 Check List 12.1.1 Check Contents of Delivery Ensure that the contents of the delivery are complete and intact. See chapter 1.3Contents of Delivery for more information. WARNING Do not use damaged components. These could disrupt or damage your system. If damaged components are found in the delivery, please contact our customer service. N'utilisez pas de composants endommagés. Cela pourrait perturber ou endommager votre système. Si des composants endommagés se trouvent dans la livraison, veuillez contacter notre service clientèle. 12.2 Maintenance This product was constructed for low-maintenance operation. 12.3 Repair When sent for repair, the panel should be transported in the original packaging if possible. Otherwise, packaging should be selected that sufficiently protects the product from external mechanical influences. Such as cardboard filled with air cushioning. In the event of a defect/repair, send the panel with a detailed error description to the address listed at the beginning of this document. 07.02.2019 Page 21

ETT 412 BUILD-IN TOUCH TERMINAL 13 Disposal When disposing of the panel, the national electronic scrap regulation must be observed. The device must not be discarded with domestic waste. Page 22 07.02.2019

BUILD-IN TOUCH TERMINAL ETT 412 Documentation Changes Change date Affected page(s) Chapter Note 11.02.2019 16 8.2 CAN Bus Data Transfer Rate Value 0 - Baud rate 615 kbaud/s removed 07.02.2019 Page 23