THE EUROPEAN REFERENCE

Similar documents
Performance Certification : From Energy Efficiency To Indoor Air Quality. By: Eric Foucherot

Chillventa Specialist Forums 2018 Chillventa Fachforen 2018

BSRIA Air Conditioning Worldwide Market Intelligence

Effect of the Certification on Chillers Energy Efficiency

ECP New Program. Hygienic Air Handling Units 29 September Krakow

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Rack cooling solutions for high density racks management, from 10 to 75 kw

CHILLERS & HEAT PUMPS DYNACIAT HIGH ENERGY PERFORMANCE WITHIN OPTIMISED FOOTPRINT

Present implementation: Condensing units, proces chillers (LT, MT) and professional storage cabinets. Per Henrik Pedersen

DATACOM COOLING CERTIFICATION PROGRAM

glide glider kw R134a air cooled liquid chillers AND free cooling chillers FREE COOLING SHELL A C CLASS E C Energy Class RCGROUP SpA

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Commercial HVAC Efficiency Regulations and Refrigerants Are Changing: Are You Ready?

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

DUCTED SPLIT SYSTEMS With Scroll compressors

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Efficiency of Data Center cooling

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

AUTOMATIC COMMERCIAL ICE-MAKERS CERTIFICATION PROGRAM

Improving the climate for data centers

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

VARIABLE FREQUENCY DRIVES CERTIFICATION PROGRAM

i-accurate_gb_ High precision air-conditioners for data centres cooling, with new inverter technology and R-410A refrigerant, from 6 to 150 kw

Ref No: RACS/PCS/10 Page 1 of 7. Revision No: 00 Revision Date: October 1, 2018 PRODUCT CERTIFICATION SCHEME FOR ELECTRICAL EQUIPMENT

Advanced RTU Campaign Taking Action Toward Efficient RTUs Michael Deru February 25, 2014

Samuel Tepp Engineering Seminar Topics

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Contents. Rev. 2, 5/12/2016 1

PT CLIMANUSA TATA MEKADATA Citypark Business District Blok F No 05 Jl. Malibu Raya, Cengkareng Jakarta Barat Indonesia. Phone

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Cooling Solutions & Considerations for High Performance Computers

Energy Engineering: Tools and Trends

Reliability and extended operation

Welcome Association of Energy Engineers to the Microsoft Technology Center

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Energy-efficient heating, ventilation and air-conditioning Technologies for certified buildings

THE BASIC REQUIREMENT OF EVAPORATIVE COOLING EQUIPMENT ULTIMATE QUALITY

ASHRAE elearning Course Catalog

30XAV & 30XWV. Air and water-sourced, variable-speed screw units. AquaForce with Greenspeed intelligence, Because you should not have to choose.

Media Pack. ENERGY EFFICIENCY BRITISH MANUFACTURER TRAINING

ICS COOL ENERGY THE TEMPERATURE CONTROL SPECIALISTS

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

LIFE CYCLE COST ANALYSIS, CRITERIA AND DATA SHEETS DOCUMENT NUMBER: APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL

Liebert. AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability CERTIFIED HVAC-HYGIENE.

Thermal management. Thermal management

ICE STORAGE BINS CERTIFICATION PROGRAM

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

FREECOOLING, EVAPORATIVE AND ADIABATIC COOLING TECHNOLOGIES IN DATA CENTER. Applications in Diverse Climates within Europe, Middle East and Africa

Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A. Company Profile

Regulations Determining Computer Room Cooling Selection

Precision Cooling. Precision Cooling Advantages

The European Programme for Energy Efficiency in Data Centres: The Code of Conduct

WATER-COOLED WATER-CHILLING AND HEAT PUMP WATER-HEATING PACKAGES USING THE VAPOR COMPRESSION CYCLE

2018 Product overview

Reducing Energy Consumption with

PROMOTION OF HIGHER EFFICIENCY ROOM AIR CONDITIONERS IN THAILAND: NATIONAL POLICY ROADMAP. Endorsed by

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

MSYS 4480 AC Systems Winter 2015

SmoothAir Modular Precision Cooling

Global Heating, Ventilation and Air Conditioning (HVAC) Market: Industry Analysis & Outlook

CTC Low Temperature Process Chillers

MULTI SPLIT 074 PRODUCT LINEUP & 3-4 ROOMS MULTI ROOMS MULTI 080 INDOOR UNITS FOR MULTI SPLIT SPECIFICATIONS 082 MULTI COMBINATION

Precision Cooling Mission Critical Air Handling Units

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Server room guide helps energy managers reduce server consumption

ANSI/BICSI Data Center Design and Implementation Best Practices

Request for Qualifications

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Energy Efficiency as Competitive Advantage. Houston, TX September 14, 2010

ANSI/BICSI Data Center Design and Implementation Best Practices

Planning for Liquid Cooling Patrick McGinn Product Manager, Rack DCLC

DATA CENTER PRECISION COOLING: The Need For A Higher Level Of Service Expertise

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Retro-Commissioning Report

We design and produce special units for applications in air conditioning, refrigeration and air treatment systems, specifically developed to meet our

Air-Cooled Series R Chiller

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Data Center Cooling Solutions

COMMERCIAL FURNACES CERTIFICATION PROGRAM

CTXA-AS/AT/AW, FTXA-AS/AT/AW

Commercial HVAC and Other Measures for 7P. Outline

Silicon Valley Power Data Center Program Rebate Application

Second Stakeholder Meeting for Nonresidential HVAC Proposals Based on ASHRAE Revisions to Waterside Economizer

PEFC: The best way to develop nationally appropriate and internationally recognised forest certification Ben Gunneberg

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

LANL High Performance Computing Facilities Operations. Rick Rivera and Farhad Banisadr. Facility Data Center Management

Commercial Controls. Advanced control for saving time and money

Training courses 2018

The IECEx Ticket to Global Markets

Balancing energy and environmental demands

INAB Mandatory and Guidance Documents Policy and Index

Transcription:

THE EUROPEAN REFERENCE Eurovent Certified Performances certification for IT COOLING UNITS Data Centre World 2019 - London Morgane LAJEUNESSE Project Manager m.lajeunesse@eurovent-certification.com

Agenda I. Presentation of Eurovent Certita Certification and the ECP brand II. Presentation of the ECP IT Cooling Units certification programme 1. History of the programme 2. Scope 3. Programme features 4. Certified performances and reference documents 5. Test conditions and rerating rules 6. Factory Audit 7. Certification procedures: Qualification and Repetition procedures

Presentation of ECC Eurovent Certita Certification is a major European certification body providing voluntary 3 rd party certification in the field of heating, ventilation, air-conditioning and refrigeration (HVAC-R) Eurovent Certita Certification certifies product performances as well as data needed to implement regulations. As an accredited certifier (accreditation n 5-0517 according to ISO 17065 by COFRAC, international recognition EA/IAF) Eurovent Certita Certification product performance certificate is recognized with a legal ground in a very large number of countries. EA : European Accreditation IAF : International Accreditation forum

Presentation of ECC Eurovent Certita Certification is: Owner of the ECP Brand: Mandated to deliver the following brands: Notified to deliver the CE marking - mandatory certification

ECC in numbers A dedicated team of 50 people based in Paris 44 certification programmes in residential domestic buildings or in industrial facilities 600 industrials certified in 44 countries in the world 1800 annual tests and 400 factory audits 2700 certificates delivered each year Eurovent Certita Certification operates with commissions responsible for the harmonization and integrity of the programs. Commissions include : Authorities, Consultants, Laboratories, Manufacturers. A Market Intelligence department that provides data on the HVAC-R market in EMEA EMEA : Europe, Middle-East and Africa 2 complementary departments among ECC : Copilot: certifies HVAC unit commissioning ProdBim: certifies Data in BIM (Building Information Modeling)

Examples of ECP programme More than 30 ECP programmes: Fan coil units Air-conditioners Filters Chilled Beams Refrigerated Display Cabinets Dry-coolers Air Handling Units Rooftops Condensers Chillers & Heat-Pumps Air to air heat exchangers Cooling towers Drift eliminators VRF

The ECP brand The Eurovent Certified Performances brand: The ECP programmes consist in independent third-party checking of product performance to encourage honest competition and to assure customers that the equipment is correctly rated on the European market. The certification relies on a continuous verification process: Analysis of the Declaration file that includes all models in the scope of the programme and selection of the units to be tested Product performance testing performed by independent and accredited laboratories On-site factory audits Check of selection software Selection software: Any kind of tool made available within the participant s organization to assist and generate an offer to customers and provide technical definition and performance of a product.

CEIS Madrid Spain CETIAT Lyon France DMT Essen Germany HTA Luzern Switzerland IMQ Amaro Italy IMQ Milan Italy SP Boras Sweden TÜV-NORD Essen Germany TÜV-SÜD Munich Germany VTT Espoo Finland WSP Stuttgart Germany DTI Taastrup Denmark ECP laboratories We work with several independent laboratories in Europe

ECP scheme Certification scheme is composed of 4 documents: OPERATIONAL MANUAL (OM) Scope of the programme Explanation of the programme Certification Campaign schedule Procedures RATING STANDARD (RS) Scope of the programme Definitions Testing and rating requirements Certified characteristics Accepted tolerances OM & RS shall comply with the Certification Manual OM & RS is completed with the Price List

ECP certification procedures BUILD USE 1 Group constitution 2 Launching Committee Certification scheme 3 Compliance Committee 4 Certificate

Agenda I. Presentation of Eurovent Certita Certification and the ECP brand II. Presentation of the ECP IT Cooling Units certification programme 1. History of the programme 2. Scope 3. Programme features 4. Certified performances and reference documents 5. Test conditions and rerating rules 6. Factory Audit 7. Certification procedures: Qualification and Repetition procedures

History of the IT Cooling Units programme EXISTING: ECP Close Control (CC), sub-programme of Comfort Air Conditioners (AC) Requirements, content and expectations not suitable AIM: Recast completely the sub-programme in a new dedicated programme ECP IT Cooling Units

History of the IT Cooling Units programme Key steps: February- March 2017: Call for participation to the LC 6 Launching Committees (LC): April 2017: First Launching Committee LC1 January 2018: Last Launching Committee LC6 March 2018: CPPC programme validation May 2018: Kick-off meeting Composition of the Launching Committee: 7 major European OEM of IT Cooling units 2 External independent EU laboratories 1 certification body Promotion of the ITCU programme: EU Commissions: GPP Green Public Procurement for Data Center EU ErP project commission Exhibitions: DCW

Scope of the programme The IT Cooling Units certification programme covers IT Cooling Units specifically designed and used to regulate air temperature and optionally air humidity of an enclosed space containing critical equipment such as IT equipment or telecommunication equipment. The IT cooling units shall be factory made units designed as a single packaged unit or a single split unit. Technologies covered: Computer Room Air Conditioners Direct Expansion (CRAC) air cooled or water cooled Computer Room Air Conditioner Chilled Water (CRAH) HYBRID technologies pairing these technologies Are excluded from the scope: Packaged CRAC air cooled units, Multi-Split units, Partial IT Cooling units with missing elements such as fans.

Scope of the programme Air flow directions: Down-flow Up-flow Horizontal-flow Air flow configurations: ROOM Based Cooling unit ROW Based Cooling Unit RACK Based Cooling Unit Features: Ducted/non-ducted units With/without floating-floor 50 Hz and 60 Hz frequency units

Programme Features The IT Cooling Unit certification is a stringent and exhaustive certification that includes: The Certify-all principle, which means that all the units sold by the participant on the EU market within the defined scope, shall be declared to ECC and can be subject to controls during the certification process. Annual random selection of units and tests in an independent and accredited laboratory chosen by Eurovent Certita Certifcation Between 2 and 6 tests, depending of the number of models manufactured Test realized under standard and non-standard conditions Software certification that extends the certification of the units to non-standard condition functioning points. An annual factory audit that guarantees a high level of quality of production and the relevance and accuracy between what is declared and what is produced and sold. Units tested are controlled during Factory Audit.

Acoustic performances Thermal performaces Certified performances Certified performances Unit Sym bol A.C. MVF HVF Standards Net Total Cooling Capacity kw P C Net Sensible Cooling CRAC UNITS: kw P Capacity S pren 14511, (4 parts) - 2018 Air conditioners, liquid chilling packages and heat pumps with Power input W P electrically driven compressors for space heating and cooling E CRAH UNITS: Supply Air Flow m3/h S af EN 1397-2015 Heat exchangers. Hydronic room fan coil units. Test procedures for Water pressure drop Pa D pc establishing the performance Net EER Energy Efficiency Ratio SHR Sensible Heat Ratio A-weighted sound power indoor side A-weighted sound power radiated by duct A-weighted sound power outdoor side W/W W/W EER SHR COMPLEMENTARY TEST PROTOCOLES : ANSI/ASHRAE Standard 127-2012 Method of Testing for Rating Computer and Data Processing Room Unitary Air Conditioners db L CRAC UNITS: W in EN 12102-2013 Air conditioners, liquid chilling packages, heat pumps and dehumidifiers with db L W du electrically driven compressors for space heating and cooling. Measurement of airborne noise. Determination of the sound power level CRAH UNITS: db L EN 16583 2015 Heat exchangers. Hydronic room fan coils units. Determination of the W out sound power level

Thermal performances Certified performances Failure treatment: When the measured value differs from declared value Beyond Acceptance criterion: rerate of unit and BMG on the catalogue and on the software Beyond High deviation threshold: rerate and 1 additional penalty test Beyond Mean deviation threshold: a ratio that takes in consideration repeated failures along test campaigns. Leads to suspension. Acoustic performance Table: test threshold Mean Deviation threshold High Deviation threshold Performances Acceptance criterion Net Total Cooling capacity < -5% < -15% < -20% Net Sensible cooling capacity Power input Water pressure drop >+15% Supply air flow +- 10% Energy Efficiency Ratio < -8% < -12% < -17% Sensible Heat ratio < -8% A-weighted sound power level >+ 2 db(a) >+ 3 db(a) Rerating rule: relative deviation between measured values and declared values is applied to the whole BMG

Test conditions Test conditions: Each selected unit is: tested under the standard testing conditions tested under a non-standard condition Standard test conditions: Four classes of application Declaration on class 2 mandatory: For CRAH units: Class Indoor Air Entering Dry Bulb Temperature Indoor Air Entering Relative Humidity* Class 1 24 C 50% Class 2 30 C 35% Class 3 35 C 27% Class 4 40 C 20% Non-Standard test conditions: all other conditions enabled by the software

Factory Audit What is declared is what is produced by regular production: or or Finite products stock Declaration file, Technical Data Sheet, Software

Factory Audit What is offered and sold is what is declared: or or Declaration file, Technical Data Sheet, Software

Factory Audit What is produced is what is tested during the certification test: + Key control points Uniformity of the production Sampling Representativeness Test samples Whole production

Certification procedures Overview of the certification procedures: Qualification procedure Repetition procedure Declaration list: contains unit performances and technical characteristics of the components. All the OEMs models are declared in the list under the standard conditions.

Any Questions?

THANK YOU FOR YOUR ATTENTION Morgane LAJEUNESSE Project Manager m.lajeunesse@eurovent-certification.com

Back-up

Test conditions