RCP2 Quick Start Guide

Similar documents
ERC Quick Start Guide

3-position, AC100/200V controller for RCP2/RCP3 Series. 3 position, AC100V controller for RCA/RCA2/RCL Series. Controller. Power supply.

Notes on Use of 24-V Controller by Grounding Its Power Supply at Positive Terminal

Motorized Gripper / Rotary ActuatorRCP2 GRIPPER R OTA RY. w w w. i n t e l l i g e n t a c t u a t o r. c o m

PIO type (PNP Specification) Controller that moves by designating position numbers with PNP PIO via PLC. 16 points

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

Quality and Innovation. Easy to use RoboCylinder.

Program controller for operating RCA2/RCA Series actuators. One unit can handle various controls. Up to 2 axes

Notice of Production Discontinuation

Power supply unit PLC. Gateway unit. 4 axes

PC Software, Operation Manual 2 nd Edition. IAI America Inc.

TTA Series. Tabletop Robot. ZR-Axis Type Series Added

C I I Type Number (Specs for 1st axis) (Specs for 2nd axis) of Axes Motor Encoder Option Motor Encoder Option

Multi-Axis Step Motor Controller

ERC3 series. ROBO Cylinder with Built-in Controller.

Advanced features to meet your application needs:

Step Motor Controller

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

PC Software. Operation Manual Twenty-ninth Edition RCM-101-MW, RCM-101-USB. IAI Corporation

Hardware Manual CNC760

Step Motor Controller

RCP2 Series ROBO Cylinder Controller. Operation Manual Nineteenth Edition

ERC Actuator with Integrated Controller

ACON-C/CG Controller Positioner Type. Operation Manual Twelfth Edition

Step Motor Controller

ACON-SE Controller Serial Communication Type. Operation Manual First Edition. IAI America Inc.

EtherCAT(R) Connection Guide IAI Corporation

Robo Cylinder Data Input Pendant RCM-P

4 Axis Step Motor Controller

CT4. Rotational Axis Equipped. High-speed Cartesian Robot

RoboCylinder Profibus Gateway

Connection Guide IAI Corporation

Controller PMEC/AMEC PSEP/ASEP/DSEP MSEP PCON/ACON-ABU SCON-CA MSCON PSEL ASEL SSEL XSEL ERC3 ERC2 PCON-CA/CFA PCON ACON PS-24.

XSEL-R/S. Program Controller XSEL Series 8-axis Specification.

ISOLATION RELAY RACK ISOLATION KIT 19 RACK MOUNT RELAY RACK ISOLATION KIT, SLOTTED UNEQUAL FLANGE RACK ISOLATION KIT 23 RACK MOUNT

Cobra 350 eplc Robot. Quick Setup Guide I592-E-01

3. How to Read the Model No. 3.1 Slider Type RCP6 SA4C WA 35P P3 P B ** Standard spec. Built-in controller spec. <I/O type> SE : SIO type

w w w. i n t e l l i g e n t a c t u a t o r. d e тел.:(495) , GB T A B L E T O P R O B O TTT

2A 3. Instruction manuals related to this product, which are contained in the instruction manual (DVD).

Faults on the system Proximity switch connection technology:

ACON-SE Controller Serial Communication Type

Product Information ECI 1118 EQI 1130 ECI 1119 EQI Absolute Rotary Encoders without Integral Bearing

Robo Cylinder Data Input Pendant RCA-P Operating Manual Ver. 4.0

Part conveyance C. Press fit A. Operation. Part conveyance A. Operation PLC. Part Conveyance A. ROBONET communications connection.

Viper 650/850 eplc. Quick Setup Guide I600-E-01

Connection Guide. SMC Corporation. EtherCAT(R) Machine Automation Controller NJ-series

Standard specifications ST AX ST70L-01-AX

Mechatronics Cylinder PC Tool Kit TBVST Termi-BUS. Operation Manual. Document No. MN1-MTX-00001B-NA Ver /10/21

Contactors and Contactor Assemblies

Type 330SA High-Performance Electric Actuator

3 Indexer Installation For PRSalpha Tools

MPU User Guide Updated 3/11/15. Overview

EPS 06 in rear housing type A1

Machine Automation Controller NJ-series. EtherCAT(R) Connection Guide. IAI Corporation. ACON/ACON-CA/ PCON/PCON-CA/ DCON-CA Controller P584-E1-02

A2K. Absolute Optical Encoder: Kit Version Page 1 of 7. Description. Features

Teaching Pendant CON-T, CON-TG, CON-TGS. Instruction Manual Ninth Edition

UCBB dual port breakout board user's manual

IO3-R2 BREAKOUT BOARD

Installing Your 1394 Drive Interface Module

527F CNC. Retrofit controller for machines made by Fadal Machining Centers. Installation and set-up manual Calmotion LLC

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

µmove/pmove Axis System

5. How to read controller model code Gateway unit model RCM EGW DV. Basic Specifications

Operating instructions AC010S Compact AS-i E-STOP safety module

udr-1300s PROGRAMMABLE MOTOR CONTROLLER

PLCADD1616 User Guide 3/29/10. Overview

Welcome to the safety functions configuration training module for ACS880 Cabinet-built industrial drives.

RoboCylinder Miniature Models 4th Revised Edition

APS4 Inductive Proximity Sensors

527F CNC. Retrofit controller for machines made by Fadal Machining Centers. Installation and set-up manual Calmotion LLC

Easy to Use. Easy to use linear motion

RTK3 Logic Controller User Manual Revised

Modicon Premium PLCs TSX CSY 84 / 85 / 164

Optical Kit Encoder Page 1 of 14. Description. Features

HB5M. Hollow Bore Optical Encoder Page 1 of 6. Description. Related Products & Accessories. Features

ADDJOG User Guide 7/30/10. Overview

RCP2CR-GR RCP2W-GR. Cleanroom. Dust-proof. Cleanroom Gripper Type. Dust-proof Gripper Type

Fiber optic converter audio and CAN TA OPERATION MANUAL

USER S MANUAL. C11S- MULTIFUNTCION CNC BOARD Rev. 1.2

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

Contents CONTENTS PREPARATION FOR COMMISSIONING... 1

Digital DRIVE for Brushless motor MD Serial

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

24 VDC or 24 VAC/DC or 110 VAC or 220 VAC NOTE: 220 VAC not available for S2 and S3 configurations. EN1088, EN , EN292, EN

ION Demo Kit. Quick Start Guide PERFORMANCE MOTION DEVICES

Apollo III INSTALLATION MANUAL

1. Overview of YC-Link/E Overview Part names of YC-Link/E compatible units Installation and settings 3

Brushless DC Motor Driver CBM-105 FN/FP User Manual

RTK4 Logic Controller User Manual For RTK4L Revision Revised

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

INSTRUCTION BULLETIN

X-SEL Serial Communication Protocol Specification (Format B)

Trio Application Control System Instruction Sheet

TXM1.8RB. TX-I/O Blinds module

Resolver to Digital Expansion Board

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

Galaxy Rectifier Shelf Field Replacement

Monitor. Safety relay,etc. Contactor, etc. Uses external device monitoring function Note: Construct a separate reset input circuit.

Indra Works DS Tuning Procedure

Transcription:

RCP2 Quick Start Guide 1. Parts Confirmation Please contact your sales representative if any of these parts are missing or incorrect: - Controller: RCP2-C or RCP2-CG - Actuator: Slider type or Rod type - I/O Flat Cable: CB-RCA-PIO020 - Motor Cable: RB-RCP2-MA*** - Encoder Cable: CB-RCP2-PA*** - CD with Manuals (PDF format) 2. Installation a. Install the Actuator. Screw diameter Standard torque for bolting M4 2.3Nm (0.23Kgf.m) M5 4.3Nm (0.44Kgf.m) b. Mount to the Actuator. - Slider Type: Use the 4 tapped holes located on the top of the slider. Max torque required for mounting: SA5/SA6/SA7/SS/SSR Optional:- Teaching Pendant - PC Software Kit - Controller Link Cable - SIO Converter RCA-T/E RCB-101-MW CB-RCB-CTL002 RCB-TU-SIO-A/B M6 6.7Nm (0.68Kgf.m) M8 14.0Nm (1.43Kgf.m) 7.5Nm (0.77Kgf.m) SM/SMR 19.6Nm (2.0Kgf.m) - Rod Type: Be sure to use a wrench to prevent adding rotational moment to the rod (see picture to the right). Use a 14mm wrench for RXA/RSA models and a 19mm wrench for the RMA model. c. Mount the Controller. NOTE: The slider type actuator has tapped holes in its back for installation purpose. The size and depth of tapped holes are as follows. Please be sure to use the proper screw length to avoid penetration. Model Tap size Depth of thread SA5 M4 4mm ~ 7mm SA6 M5 5mm ~ 9mm SA7 M5 5mm ~ 9mm SS M5 5mm ~ 8mm SM M8 8mm ~ 10mm 3. Wiring - Connect to DC (Min. 2A) power supply - Ground the FG wire - Connect the emergency stop and motor power supply wires - Connect the I/O flat cable Because the HOLD signal is a normally closed contact, it is ON during operation and OFF during pause. If there is no PLC software at the time of adjustment, change parameter #15 (refer to the last page of this Quick Start Guide). You can also temporarily short it to 0V in case of NPN or in case of PNP. (It becomes necessary to use the teaching pendant or PC for operation). Afterwards, you must remove this short if you plan to automatically operate it with a PLC. - Connect the motor cable & encoder cable When combining multiple axes, be sure to verify that the configurations for your actuators and controller are correct. Otherwise, they will not operate properly. www.intelligentactuator.com

4. LED Indicator for Power Supply Before supplying power, confirm that the PORT switch on the controller is turned OFF and that the emergency stop circuit is not operating. Also check to make sure that the green [RDY] and [RUN] LED indicators in front of the controller are both lit, and that the red [ALM] indicator is not lit. A lit [ALM] indicates that the emergency stop circuit is open, or that an alarm is occurring. At this point, you should refer to the "Troubleshooting" section of your Operating Manual to resolve this problem. 5. Input Data & Operate with PC or Teaching Pendant Connect the SIO connector at the front of the controller to a teaching pendant or PC. Then turn ON the PORT switch. (If you are using a teaching pendant, first turn OFF the EMG switch. Otherwise, the emergency stop condition will occur). Input desired data such as position, speed, acceleration/deleceration, position range. Note that during operation the Start Signal Input and Home Return are OFF, and Pause is ON. Flat Cable <CB-RCA-PIO020> Emergency stop circuit & DC System Configuration Diagram PLC I/O Signal Controller <RCP2-C> <RCP2-CG> Refer to following pages for operating instructions Teaching Pendant, PC Standard <RCA-T> Encoder Cable <CB-RCP2-PA***> Motor Cable <CB-RCP2-MA***> Power and Emergency Stop Connections PC Software <RCB-101-MW> Actuator - Internal Drive-Power Cutoff Relay Type <RCP2-C> External EMG Circuit - External Drive-Power Cutoff Relay Type <RCP2-CG> External EMG Switch 0V Jumper S1 S2 MPI MPO N EMG Jumper 0V FG Safety Relay Unit Contactor Note: The S1 and S2 connections correspond to the emergency stop of the Teaching Pendant. S1 S2 MPI MPO N FG

Operation with the PC Software or Teaching Pendant As an example, we will set 50mm as Position No. 1 and move the actuator to this position. 1. Using the PC Software 1 Action Run the software 2 Action Click "Edit Position Data" button "Edit Position Data" button Action1 Move the cursor to Position No. 1 Action Click >, then OK buttons 4 Action2 Input 50.00 and hit the "Enter" key Other data, such as speed and acceleration are automatically input with their default values. Action Click "Send to Controller" button 6 Action Click "Move" button All data in the Position Table is sent to the controller. The actuator will move 50mm to Position No. 1. Use the "Stop" button to stop movement. During power start-up, the actuator will return to its Home before moving 50mm to Position No. 1. "Send to Controller" button "Move" button "Continuous Move" button "Stop" button

Parameter Change Procedure for Standalone Testing Purpose To show the procedure for connecting and testing a RoboCylinder unit without using an I/O (no connection to a PLC). This procedure will disable the HOLD input and disable the SERVO ON input. This will also allow the actuator to be run on a benchtop for testing purposes. Where Used When getting a '20D' error when running the system without an I/O connection to a PLC or similar device. Instructions apply to RCP2 products. 1. Connect the actuator to the controller with the supplied IAI cables. 2. Connect the PC cable from serial port on PC to PORT IN on controller (looks like mouse input port). 3. Supply power to the controller and turn ON. 4. Turn PORT ON. 5. Start IAI RoboCylinder Software and connect to controller (auto). 6. Back up the parameters to a local file on the PC by choosing PARAMETERS Edit Select Axis. Click the DISK button to save a copy locally. 7. Go to PARAMETERS Edit Select Axis. Change Parameter #15 PIO INPUT state from '0' to '1'. 8. Click the SEND TO CTL button or select it from the FILE pull-down menu. 9. Click OK and cycle the power to the controller. 10. Reconnect the software to the controller and the system should be ready to move under local PC control from the POSITION menu. For additional questions please contact IAI Technical Support or see www.intelligentactuator.com for more info. US Headquarters (CA): 1-800-736-1712 Mid West Region (IL): 1-800-944-0333 East Coast (NJ): 1-732-683-9101