Instruction Manual. Rack PDU XP Series. geistglobal.com

Similar documents
Instruction Manual Basic Rack PDU VP7541 and VP9571A

Auto-Transfer Rack Power Distribution Unit

Instruction Manual Rack Power Distribution Unit. J, VHV Series

Instruction Manual Rack In-Line Power Measurement Unit. L Series

Instruction Manual. Rack PDU BRE and VRTE Series. geistglobal.com

Instruction Manual. Rack PDU BR, SP, SVR, VRT, NSV, and VSS Series. geistglobal.com

Instruction Manual. Rack PDU J, VHV, and MJ Series. geistglobal.com

LVN5200A-R2, rev. 1, Hardware Installation Guide

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

3M RFID Tracking Pad Model 770

SAFETY WARNINGS AND GUIDELINES

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Instruction Manual Environmental Monitoring Unit with Optional POE. Watchdog 15 Series Firmware Version 1

Stacking Module. Installation Guide AT-MCF2000S. PN Rev A

elise 3 embedded linux server including safety instructions

Zebra RW 420 Mobile Battery Eliminator Kits

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Unity 100-watt Bridgeable Power Amp

Switched Rack Power Distribution Unit

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

RCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number

G5 PDU Installation Guide

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

Safety and Radio-Frequency Interference

HDMI and USB KVM Extender

Plug-in wireless speaker

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

BCM2 Series Branch Circuit Monitors Quick Setup Guide

MONOPRICE. Blackbird 4K Pro 1x2 Ultra Slim HDMI Splitter. User's Manual P/N 21612

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

TWISTED PAIR DISTRIBUTOR KE 0108CH-DW. Instruction Manual. Thank you for your purchase of this product

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Handset Charging Rack OpenStage WL 3 / OpenStage WL3 Plus. Installation Guide A31003-M2000-J

WIRELESS BLUETOOTH BOOMBOX

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

SB Channel Soundbar with Built-in Subwoofer

2 Mesa Ethernet Dock User s Manual

Lightspeed Advanced Reporting Bottle Rocket Hardware Installation Guide

iconverter 2-Module Power Chassis

USER GUIDE. Laptop Charger NS-PWLC591/NS-PWLC591-C. Before using your new product, please read these instructions to prevent any damage.

Changes or modifications not expressly approved by InFocus Corporation may void authority to operate the equipment.

MONOPRICE. Blackbird 4x4 HDMI Matrix/Extender with 4 Receivers. User's Manual P/N 21905

Controller Specifications

MONOPRICE. Blackbird HDMI Bi-Directional Switch. User's Manual P/N 24280

CSM200 Expansion Tray

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

HD40H(X) Performance Series Camera. User Guide

Solarflare X2522 network adapter Quick Start Guide

PM Series Power Meter

ShoreTel IP Phone 655. Quick Install Guide & Warranty

Installation Guide DRAFTMF4100

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

Emotiv Insight User Manual. Revision 1.0 June 2015 Emotiv Inc, 2015

SANnet II Family Safety, Regulatory, and Compliance Manual

USB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide

CONVERTEON Family. One-Slot Chassis AT-CV1000. Installation Guide Rev. A

KP7 Keypad Quick Install Guide

OVERVIEW. *Press and release. *Hold for 5 seconds. *Charging port

IFS NS P/4S GE-DSSG-244 GE-DSSG-244-POE Quick Installation Guide

USB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Fast Ethernet Switch AT-FS705L. Installation Guide Rev. A

Media Conversion Rack-Mount Chassis AT-MCR12. Installation Guide Rev. A

Stage Rack Installation Guide

PD-6506, PD & PD-6524

Panduit Basic Rack PDU

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

Broadband Automatic Disconnect Switch. User Manual

IPS-800/1600-D20 Series

Rack Power Distribution Unit AP7530, AP7540

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

SySTIUM TM TECHNOLOGIES Model 215

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

PDU Branch Current Monitoring Board Installation and Configuration

NANOPTIX HEAVY DUTY KIOSK REGULAR CUTTER PRINTER Thermal Print Mechanism Replacement

MONOPRICE. Blackbird 4K HDMI 1x8 Splitter/Extender. User's Manual P/N 18787

* * Agilent Power Distribution Unit (PDU) Installation Guide

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Quick Start Guide. C-100 Series Switches

CAUTION: Before installing the Windows or Macintosh operating system, see our knowledge base answer ID 1485 for precautionary procedures.

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

USB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

Ultra Slim Multimedia Keyboard (KB3100MF)

WCC100 IN-VEHICLE CHARGING CRADLE OWNER S MANUAL

User Manual. Per Port Monitoring Models

Panduit Basic Rack PDU with Local Meter

WTI Part No Rev. H. VMR Series. Managed Power Controllers. NPS Series. Network Power Switches. User's Guide

Infosystem Remote Touchscreen Installation Instructions

Multi-Power Miniature Media Converter 10/100/1000 JUNE 2007 LGC322A-NPS LGC320A-NPS, LGC321A-NPS,

This document will show you how to set up the Hotwire 6205 ADSL Modem, and how to customize its configuration to get the most out of this product.

Transcription:

Instruction Manual Rack PDU XP Series geistglobal.com

Table Of Contents 3 Table of Contents Specifications 4 Overview... 4 Environmental... 4 Tem perature... 4 Hum idity... 4 Elevation... 4 Electrical... 4 Receptacle... Ratings 4 EMC Verification... 4 Installation 6 Instructions... 6 Guidelines... 6 Mounting Optional Local Monitoring 7 14 Power... Meter 14 Current... Meter 14 Service/Tech Support 15 Service... and Maintenance 15 More... Technical Support 15 Revision History 15 3

4 RPDU Instruction Manual XP Series Specifications Overview The XP Series products are Power Distribution Units (PDU) intended for connection to a 30 Amp AC Mains circuit.* The PDUs are designed to be powered by either a single phase or a three phase AC input circuit. Three phase units can be configured for either a delta or wye input connection. XP Series PDUs can optionally be configured with a Geist Current Meter that provides local monitoring and display of each output circuit current. *Global Versions of the XP Series are intended to be connected to a 32 Amp AC Mains Branch Circuit Environmental Temperature Operating: Storage: 10 C (50 F) min 45 C (113 F) max -25 C (-13 F) min 65 C (149 F) max Humidity Operating: Storage: 5% min 95% max 5% min 95% max (non-condensing) (non-condensing) 0 m (0 ft) min 0 m (0 ft) min 2000 m (6561 ft) max 15240 m (50000 ft) max Elevation Operating: Storage: Electrical See nameplate for unit ratings. Receptacle Ratings NEMA 5-15R or L5-15R NEMA 5-20R or L5-20R NEMA 6-20R or L6-20R IEC-320 C13 IEC-320 C19 125 Volts, 15 Amp 125 Volts, 20 Amp 250 Volts, 20 Amp 125/250 Volt, 15 Amp (per Receptacle Bank) 125/250 Volt, 20 Amp EMC Verification This Class A device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Specifications 5 This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment.

6 RPDU Instruction Manual XP Series Installation Instructions 1. 2. 3. 4. 5. Using appropriate hardware, mount PDU to rack (see Mounting section for additional instructions. Plug PDU into de-energized 30 Amp branch circuit receptacle.** Connect devices into PDU s output receptacles. It is recommended that the devices are turned off until all devices are connected to PDU Turn on branch circuit to energize PDU. Power on devices. Sequential power up is recommended to avoid high inrush current. **Branch Circuit should be sized based on the PDU s nameplate electrical rating. A 24 Amp rated PDU is intended for use on a 30 Amp Branch Circuit. For Global Units a 32 Amp rated PDU is intended for use on a 32 Amp Branch Circuit. Guidelines If the PDU is installed in a cabinet the ambient temperature of the rack should be no greater than 45 C. Install the PDU such that the amount of airflow required for safe operation of equipment is not compromised. Mount the PDU so that a hazardous condition is not achieved due to uneven mechanical loading. Follow nameplate ratings when connecting equipment to the branch circuit. Take into consideration the effect that overloading of the circuits might have on over-current protection and supply wiring. The PDU relies on the building installation for protection from over-current conditions. A certified overcurrent protection device is required in the building installation. The overcurrent protection device should be sized according to the PDU s nameplate ratings and local/national electrical codes. Reliable earthing of rack-mount equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit. The PDU must be connected to an earthed socket-outlet.*** The PDU is intended for Restricted Access Locations only and only qualified service personnel should install and access the PDU. For pluggable equipment, install the PDU so that the input plug or appliance coupler may be disconnected for service. Sequential power-up of devices powered by the PDU is recommended to avoid high inrush current. Caution: Disconnect all power cords before servicing. The PDU is intended for use with TN, TT, or IT power supply systems ***XP Series PDUs may optionally be configured as Isolated Ground units. All Isolated Ground units will be shipped with an enclosure grounding cable. This cable must be connected between the enclosure and a reliable safety ground.

Installation 7 Mounting Full Length Bracket Using the full length bracket, mount PDU to rack as shown Mini "L" Brackets (SLB-4)

8 RPDU Instruction Manual XP Series Using the mini L brackets, attach PDU to rack as shown Vertical Extension Brackets (VCB-1) Using the vertical extension brackets, attach PDU to rack as shown Toolless Mounting Hardware (11621) Secure toolless mounting buttons to PDU as shown. Use toolless buttons with key-holed slots built into cabinet or with optional Geist key-holed brackets.

Mounting 9 Toolless Full Length Bracket (TLFL) Using full length toolless bracket and toolless mounting buttons, attach PDU to rack as shown Single Side Mount 2 Unit Brackets (TSMX2) Using single side mount 2 unit brackets and toolless mounting buttons, attach PDU to rack as shown

10 RPDU Instruction Manual XP Series Offset/Side Mount Brackets (EZB-1) Using the offset/side mount brackets, attach PDU to rack as shown. 7" Extension Brackets (XB-7) Using the 7 extension brackets, attach PDU to rack as shown

Mounting 11 Flush Mount Brackets (FM) Using flush mount brackets, attach PDU to rack as shown Adjustable Mount Brackets (AM) Using adjustable mount brackets, attach PDU to rack as shown

12 RPDU Instruction Manual XP Series Panel Mount Brackets (PM) Using panel mount brackets, attach PDU to rack as shown 23" Conversion Mounting Brackets (23-RM) Using conversion mounting brackets, attach 19 PDU to 23 rack as shown

Mounting 13 Cable Mount Bracket (CMB-1) Attach cable mount bracket to PDU as shown; use tie-wraps to secure cords to bracket 19" Horizontal/Panel Mount Brackets (7938) Using the 19 horizontal/panel mount brackets, attach PDU to rack as shown

14 RPDU Instruction Manual XP Series Optional Local Monitoring Power Meter The Geist PM-1 power meter is a low-power, high accuracy meter capable of measuring true RMS Current, Voltage, Power, and Power Factor. These values are individually shown on an easy to read, 4-digit LED Display, which continuously scrolls through the four different measured values. Each one of these displayed parameters is defined below. The Power Meter will automatically begin cycling through the displayed values when the PDU is connected to AC Mains power. Current: PDU output current draw measured in true RMS Amps Voltage: PDU output voltage measured in true RMS Voltage Power: PDU output power measured in Watts referred to as real or active power Power Factor: Ration of real PDU output power to apparent PDU output power**** Power Meter Display ****Real power is the power in a circuit that is transformed from electric to non-electric energy, while apparent power is the total power supplied to the circuit. Current Meter The Geist CM-1 current meter is a low-power, high accuracy meter capable of measuring true RMS Current. The value of current is continuously shown on an easy to read, 4-digit LED Display. The Current Meter will automatically begin to display value of output current when the PDU is connected to AC Mains power. Current Meter Display

Optional Local Monitoring 15 Service/Tech Support Service and Maintenance No service or maintenance is required. Do not attempt to open the PDU or you may void the warranty. No serviceable parts inside. It is recommended that power be removed from the unit before installing or removing any equipment. More Technical Support http://geistglobal.com Americas 1 888 630 4445 Europe and Middle East From within the UK 0845 026 3853 From abroad +44 845 026 3853 Asia English +1 888 630 4445 (US number) Chinese +86 755 8663 9505 Email: support@geistglobal.com or contact your distributor Technical Support Form: http://www.geistglobal.com/tech-support Revision History Revision Date Notes Approved By 1.0 5/20/2010 Original Published Version BP 1.1 7/1/2010 Minor Text Edits BP 1.2 1/24/11 Added Satellite Current Monitoring SC & BP 1.3 3/12/12 Add Packet Power CG 1.4 6/22/2012 Changed Logo and Web Address SR 2.0 7/29/2014 Changed Company Name QN 3.0 5/30/2017 Remove Current Monitor and CM-3 GY

Thank You For Purchasing Geist geistglobal.com