PRODUCT MANUAL SMOKE-1500 ENGLISH. Version: 1.0

Similar documents
Z-350 FAZER USER MANUAL

FT-20 Fire Training Fog Machine User Manual English

FAZE 800 FT PRO USER MANUAL. Version: 1.2. ROBE Lighting s.r.o. Czech Republic

W-715 Fog Jet USER MANUAL English 2013 Antari Lighting and Effects Ltd.

FT-20 Fire Training Fog Machine User Manual English

Stage Fog Machine User Manual

Z-380 Fazer Machine User Manual English

S-100X / S-200X Snow Machine User Manual

User Manual for the Antari M-1 Mobile Fog Machine

S-500 Snow Machine User Manual English

User Manual for the Antari M-1 Mobile Fog Machine. Congratulations on the purchase of your new ANTARI M-1 Mobile Fog Machine

SW-250 Wireless Control High Output Snow Machine User Manual

Robe X1 FT PRO USER MANUAL. Version: 1.1. ROBE Lighting s.r.o. Czech Republic

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

1 Channel Strobe Controller ORDERCODE 40226

LCU-2S Liquid Supply System User Manual English

V1.0. Showven Technologies Co.,Ltd.

Octostrip ORDERCODE 42220

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

OPERATION MANUAL FEATURES BEFORE USE SAFETY INSTRUCTIONS: JB SYSTEMS 1/6 COLOR JET

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

VBAR 270. User Manual. Version 1.2

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

LED SPIDER MOVING HEAD LIGHT

LOW FOG 3000 FT USER MANUAL. Version: 1.0. ROBE Lighting s.r.o. Czech Republic

LCU-1S Liquid Control Unit User Manual English 中文

Fog machine PT Users Manual

Robot Light V2. User Manual

ZEPHYR Compact Haze Machine

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

Colour Star Sky I DMX ORDERCODE 40341

1 Channel Sliding Profile Dimmer ORDERCODE 50425

LED Par 64 Short DMX ORDERCODE 42431

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

Order code: EQLED53 User manual

LIGHT BRICK - 12 X 3W TRI-COLOUR

D-Pack 6 Classic ORDERCODE 50315

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

PROFESSIONAL SHOW LIGHT

Ostar Eye K6. Beam and Kaleido Effects. User manual. Please read the instructions carefully before use

Haze 800 DMX. User Guide. English

Magnum Club Smoke System

Spectrum Laser. User manual UK. Version 1.0

LED W RGBA User Manual

Blue Weapon Laser. User manual UK. Version 1.0

Multidim ORDERCODE 50391

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

Ostar Eye K18. Beam and Kaleido Effects. User manual. 6. Fixture Cleaning. Please read the instructions carefully before use

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

TourPro RGBAW Stagebar USER MANUAL

DUAL LASER PACK & CONTROLLER USERS MANUAL

Large Police Light 100W ORDERCODE 80361

ALO Duo Roll DMX LED barrel scanner with dual light source

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

LED BEAM MOVING HEAD FL x3W User Manual

User Instructions. American DJ

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

3D OBJECTS RGB LASER. Order ref: UK User Manual

Hazer DHZ-660 USERS MANUAL

Professional DMX Stage Backdrop

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Fog machine H-1 Moving Head

imove 50SR LED-MS50A User Guide Professional Entertainment Technology

i.shine 1136 RGBW Color Stainer CN USER MANUAL

Light Brick ORDERCODE 50370

LED DANCING FLOOR User Manual

Antenna Distributor ORDERCODE D1444

Warning... Safety-instructions Operating Determinations Rigging... Description... Features and Overview...

COB100/200W 2in1/3in1 led Par Light

MATRIX LED LED User Manual Please read the instructions carefully before use

Titan Strobe ORDERCODE 40222

LED Dancefloor ORDERCODE 42300

Snapshot. Hurricane 1800 Flex USER MANUAL

ITA100 MKII 100mW green DMX laser

Eternal Lighting. Premier150 Spot. User Manual

Party Dimmer IEC ORDERCODE 50324

MANUAL. ENGLISH Showtec PSA-161 Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

LED Powerbar 24 ORDERCODE 41331

LED Slimline PAR RGBW 7x8W

12X3W UV LEDS PROJECTOR LED- 12 USER GUIDE

Fire Fogger 1500 fog machine. user manual

Blitzer Strobe. User Manual. Order code: EQLED366

Promopar ORDERCODE 30120

CP 64 BD15 CP 64 PD15

N-E Color Par 64 USER MANUAL

dynamic white par manual

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

RGB Power Batten. User Manual. Order code: EQLED032

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

i.shine 3148 RGBW Color Stainer XP USER MANUAL

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Shogun DJ G-40 ORDERCODE 32000

Quick Reference Guide

4-CHANNEL DMX WALL-MOUNTED CONTROLLER

w w w. p r o l i g h t. c o. u k STAGE PAR 64

ef smoke 3100 manual

CW-WW LEDWash USER MANUAL

User Manual Please read the instructions carefully before use

Transcription:

PRODUCT MANUAL SMOKE-1500 ENGLISH Version: 1.0

CONTENTS Warning 1 Caution 3 Please note: 3 Important 3 Description 4 Figure 1 SMOKE-1500 Functions 5 Getting ready 6 Set Up 6 DMX Connector Pin Assignment 7 Operation 8 Figure 2 DMX Chart 9 Important 11 Note other important detail 11 Troubleshooting 12 Maintenance 12 Product Specification 13 Appendix-A SMOKE-CONTROL 14 Appendix-B DMX Dip Switch Value Guide 16 If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Instructional icons Read the manual Indoor use only This symbol indicating separate collection for electrical and electronic equipment!! Warning: situations that could cause injury to yourself or others Caution: situations that could cause damage to your machine or other equipment Note: notes, usage tips, or additional information

Thank you for selecting our SMOKE-1500, you already own the high-tech, professional DMX Fogs! Better read the manual thoroughly before operation, follow instruction will help you have a smooth handling with SMOKE-1500 to achieve the most satisfactory fog effect, it will also assist unit to further prolong life time as a whole. Warning! Like all electronic products, SMOKE-1500 must be used with safety precautions in mind. Fill enough fog fluid before plugging in, empty fluid tank when not in use or moving. Products for indoor use only. Keep away from liquids. Never operate in rain or in damp conditions. Use only appropriate, grounded electric power supply for your unit. See your product specification label for appropriate power supply. This appliance must be earthed. Disconnect from electric mains power supply when not in use, when filling the fog fluid tank, or when changing a fuse. Keep unit dry. If moisture or liquids enter the fog machine case, immediately disconnect power. Contact a service technician to determine safety for use. Keep machine in flat position, never put it in tilted place. Before moving fog machine, always drain fog fluid into the tank and tighten the tank cap securely to avoid spilling. Without user-serviceable parts in the package, please contact your local agent or qualified technician for servicing. Without changeable structure by non-qualified user, please do not open the up cover or have any change at will, otherwise, it may cause an accident! (1)

Fog machine is for adult use. Keep out of reach of children. Never leave the unit running unattended. Fog machine nozzle gets hot over 200 degrees (celsius) during use. Don t touch! Maintain a safe distance over 100CM. Never aim the nozzle directly at people. Keep case closed while operating. Put fog machine in drafty place, do not insert objects into air vents. Allow 20cm space or above around the machine for proper ventilation. Keep fog machine away from flames and flammable items. Never aim the nozzle at open flames or sparks. Use only high quality water-based fog fluid. Never put flammable substances into the tank. Machine must cool down before cleaning, servicing or storing. Never put any flammable material (lipid, gas, perfume etc.) into the tank, read the user manual thoroughly before operation. Better use our high quality water-based fog fluid, random use with other fog fluid may jam the pipe, or even erode the components inside. Keep sufficient fog fluid in tank. Operating the unit without sufficient fog fluid, will damage the pump. If any abnormal running occurs, stop it immediately, empty the fluid, and bring the done up unit (recommend original box) to your agent or dealer for servicing. Make sure all fluid is empty from the tank before moving or shipping. Never drink fog fluid. If fluid contacts eyes or skin, rinse skin thoroughly with water. Read user manual instructions thoroughly before operating. Follow the instruction. Never remove warning or informative labels from the unit. (2)

Caution!! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact your local dealer. Please note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. Important The wires in this mains lead are colored in accordance with the following code. EU Green and Yellow Earthed (E) Blue Neutral (N) Brown Live (L) Warning: This appliance must be earthed. USA Green and Yellow Earthed (E) White Neutral (N) Black Live (L) Warning: This appliance must be earthed. (3)

Description DMX on board, 2 DMX modes for choice; 1CH, 3CH, operate by any additional DMX controller. Simply to operate by SMOKE-CONTROL timing control allows easy timing control volume, interval, and duration through by control panel. Humanized warning function for abnormal status: In case the fogger has any abnormal functioning, the status of LED under the tank will be indicating abnormal status as warning to let the user be aware of the problematic situation in time. LED heating indicator system in tank: Red ON= Heating; Red OFF=Ready to use; Red Flash= Out of fluid. Advanced oil-level sensor detects shortage of oil and warns the pump to cut the oil supply automatically. Aluminum die-cast design functioned with high-effective heating module prevents clogging. Triple safety protection of heater gave consumers more security. High output fog machine, approx.18,000 cu.ft/min output for SMOKE-1500. Electronic Thermo Sensing (ETS) electronic heater stay hot at all times between fog blasts. Direct thermal protection. Master / Slave mode can be operated either by the built-in timing control or by outside connected controller. Simple and humanized design makes the fogger easier for use. (4)

Figure1 SMOKE-1500 Functions A B C D E F G H I L K J A. Bracket B. Handle C. Fog Fluid Tank D. Safety Loop E. LED Indicator F. DMX 3 pin XLR Output G. DMX 3 pin XLR Input H. Control Socket Connection I. DMX Dip Switch FDS1: OFF=DMX 1CH; ON=DMX 3CH FDS2: No function J. Power Switch K. Fuse Holder L. Electric Power Input (5)

Getting Ready All products are thoroughly tested at the factory and shipped in perfect condition. If damage has occurred during shipping, or if components are missing, please contact your local dealer immediately. Your package should include: 1. One SMOKE-1500 2. One SMOKE-CONTROL timer controller 3. One powercon cord 4. One product user manual Set Up 1. Open the shipping carton and carefully remove the unit from the shipping carton. 2. Be sure to remove packing material from around the fog machine, especially near the nozzle. 3. Set the fog machine on a dry, flat surface. 4. Place the feeder tube with filter deep inside the full fog fluid tank (C of figure1). Use only high quality, water-based fog fluid. 5. Firmly attach the remote control mechanism to socket (H of figure1) on the back of the unit. Or use DMX control setting (I of figure1) on the back of the unit. 6. Plug mains power cord from the fog machine into appropriate power supply socket. Wait about 7 minutes for heating element to heat up. 7. Refer to your controller manual for operation details. (Appendix A & B) 8. If fog is emitted continuously for a long time, the heating element temperature may drop, shutting off fog production. If so, please do not activate for emission. Wait briefly. When the heating element temperature rises, fog emissions can be resumed. (6)

DMX Connector Pin Assignment The machine provides a 3- or 5-pin XLR connector for DMX connection. The diagram below indicates pin assignment information. 5 pin XLR 3 pin XLR 1. Ground 5. N/A 1. Ground 2. Cold 2. Cold 4. N/A 3. Hot 3. Hot 5. N/A 1. Ground 2. Cold 1. Ground 4. N/A 2. Cold 3. Hot 3. Hot XLR Pin Configuration Pin 1= Ground Pin 2= Data Compliment (negative) Pin 3= Data True (positive) Pin 4= No use Pin 5= No use XLR Pin Configuration Pin 1= Ground Pin 2= Data Compliment (negative) Pin 3= Data True (positive) (7)

Operation Function Dip Switch Selection: FDS1: Channel Selection OFF: DMX 1CH FDS2: No Function ON: DMX 3CH Remote Control Operation (Any of DMX Dip 1-9 OFF ) For best result, use SMOKE-CONTROL timing controller. 1. Firmly attach the remote control mechanism to socket (H; figure 1) on the back of the unit. 2. Plug mains power cord from the fog machine into appropriate power supply socket. Wait about 7 minutes for heating element to heat up. 3. Refer to your controller manual for operation details. (Appendix A) DMX Control Operation (Any of DMX Dip 1-9 ON ) Use DMX Dip switches 1-9 to set the unit to the desired DMX512 address. Refer to the DMX value guide in Appendix B. 1. Connect the DMX 512 controller cable to the input socket (G of figure 1) of the fog machine unit. Make sure the signal cable polarity is correct. Connect power lines. Your machine is now ready for operation with your DMX controller. 2. If desired, connect another fog machine: Plug one end of another signal cable in to the output socket (F of figure 1) on the back of the first SMOKE-1500; plug the other end of the signal cable to the input socket (G of figure 1) on the back of the second SMOKE-1500. Follow the same procedure to link more fog machine, if desired. (8)

Figure 2 DMX Chart DMX 1CH MODE... CH1 Volume 5-255 10%-100% 0-4 OFF DMX 3CH MODE... CH1 CH2 CH3 Volume Interval Duration 5-255 10%-100% 0-4 OFF 0-255 10-250(s) 0-255 1-10(s) (9)

MASTER/SLAVER Operation (Any of DMX Dip 1-9 OFF ) More than two foggers can be set as synchronic fogging mode by SMOKE-CONTROL. Following is the setting way: 1. Master fogger: 1.Set DMX Dip Switch 1-9 to OFF, at this moment, DMX for output mode, used to control other fog machines connected to follow the synchronous action; 2. Slave fogger: After connecting in series, set DMX address of all slave foggers to 1 and set its FDS1 to OFF (the number of channels is set to single channel); 3. Done! Now you can use the SMOKE-CONTROL for master / slave operation. SMOKE-CONTROL (10)

Important: Any of DMX Dip 1-9 ON for Master fogger, will switch to DMX mode, only for receiving external DMX control signals, and stop Master/Slave control by SMOKE-CONTROL. For Master/Slave control, only one fogger can be set as the Master fogger. The DMX Dip 1-9 cannot be set to OFF for any of the other Slave fogger. As the high power better put SMOKE-1500 in steady place. If do tilt it for special need, please fasten it thoroughly with incline angle within 15 degree. Note other important detail: Plugging SMOKE-1500 in, the red LED under tank bottom will glow indicating power on & warming-up. Check if with correct voltage in case it doesn t glow. Red LED off appears as warm-up arrives at fogging point, indicating a finished heating time. Besides, SMOKE-1500 devises the low fluid sensor. Red LED under tank bottom will automatically flash to warn low fluid supply. The pump stops simultaneously. Keep an eye on to ensure enough fog fluid when running. Should there be any low fog emitted, running noisily or hindered fogging, pull out the plug immediately. Check if string enough fog fluid, or if outside fuse, controller connection and power supply improper, if not, plug-in again, still persists abnormal running, check if with an unhindered pipe, with flowing fluid. If causation is unclear, stop running to avoid any damage, shut down to cool it, and bring unit to your local agent or appointed service place for inspection, prohibit any dismantlement by yourself. (11)

Troubleshooting This troubleshooting guide is meant to help solving simple problems. If a problem occurs, carry out the steps below in sequence until a solution is found. If the problem persists, refer servicing to a qualified technician. -- Power Connected but No Fog Is Emitted 1. Check the power supply. Plug the unit into grounded electric power supply socket with proper voltage. 2. Check your controller connection. 3. Check your DMX address setting. 4. Disconnect fog machine from electric power supply. Replace fuse with one of the same type. Maintenance Before doing maintenance, please make sure that the power is cut, the power cord is unplugged, and the machine itself has cooled down. The maintenance must be done by qualified person. The fog liquid is not allowed to get dirty. Be sure to always clean or replace the caps on the fog liquid vessel and tight the cover of the fog machine liquid tank immediately after filling. The nozzle can be possibly jammed with impurities after long-time use. Dismantle the nozzle for cleaning every certain period of time to keep its flow. Periodically check the connections among the oil tube, the pump and the heater to see if there s oil leaking. If positive, lock tight the connections carefully with proper tool. PC board should be kept from being dirtied with oil. In case this happened, dismantle carefully the PCB, and have it brushed clean both sides with dilute alcohol. Leave it dry itself, then install it back. Make sure all wires are well connected. Clean the metal cover with dry cloth. (12)

Product Specifications Item No. SMOKE-1500 Consumption 1450W DMX Channel DMX 1CH or 3CH Master/Salve Yes Fuse (230V) T7A/250V Tank (L) 2 Fog Output (cu.ft/min) 18000 Warm Up time(min) 7 Fluid Consumption (ml/min) 45 Date Connection 3P XLR Low Fluid Shutdown Yes Bracket or handle Both Voltage 230V/50Hz Dimensions/mm(LxWxH) 418 220 209mm Weight (kg) 7.5kg Matching Controller (Included) SMOKE-CONTROL * Voltage is preset at the factory and may not be changed. 418mm 220mm 209mm (13)

Appendix-A SMOKE-CONTROL D G E F Timing Remote Control Operation... A B C Function Timers ON/OFF Continuous Fogging Manual Fogging D Duration 0.5s~10s±1s E Interval 3s~255s±1s F Volume 10%~100% G 1/4 jack cable 8m A B C (14) Movement Instruction Press the button; the timer of interval output ON and the upper red LED will glow. Press the button, the fog machine emits fog continuously and the upped red LED will glow. Press the button, it allows the operation be controlled manually. After the machine has warmed up, the upper green LED will glow.

SMOKE-CONTROL timing controller is suitable for SMOKE-1500, the operating manners and functions as follows: 1. The order of fogging: Manual Fogging-->Continuous Fogging-->Timing Fogging 2. Red LED of machine: On, heating up; Off, heating is completed; Slow flash, low fluid level indication; Fast flash, the thermal sensor wire falls off or acts abnormal; Intermittent flash, the communication of thermo circuit and main control circuit faulted. 3. When TIMER button pressed (down), the upper red led glows, means timing function turns ON; the fogging duration is adjusted by turning Duration knob, Interval knob sets the amount of time in between every fog output, and Volume knob is adjust the fog volume. Duration and Interval knobs are effective at this moment. TIMER button release (up) to OFF the timing function. 4. When CONTINUOUS button pressed (down) to turns on, the upper red LED glows, the machine emits fog continuously until an OFF green LED appears (indicating time is now to warm-up again). Under this state, Volume could be adjusted by knob. TIMER and MANUAL button are ineffective at this moment. 5. When the MANUAL button is pressed (down), the fog output is output with the maximum amount of smoke. When the MANUAL button is release (up), it returns to its original state. Caution: Before removing or replacing the remote control unit disconnect the power cord. (15)

Appendix-B DMX Dip Switch Value Guide This is a brief guide to DMX dip switch value settings. DMX products must have their own address to receive DMX signals. Addresses on SMOKE-1500 are set by flipping appropriate DMX dip switches. To do this, you need to know the DMX dip switches have the following values: #1=1; #2=2; #3=4; #4=8; #5=16; #6=32; #7=64; #8=128; #9=256. And you need to know that DMX address settings are the sum of the dip switch values. For example, standard DMX addresses for four SMOKE-1500, each of which has three channels (see Figure 2), follow: Address Value DMX Dip Switches ON Unit 1 1 #1 Unit 2 4 #3 Unit 3 7 #1, #2, & #3 Unit 4 10 #2, & #4 Explanation: Since each unit has one channel, each address advances one values (see address value above). Once address values are figured out, add DMX dip switch values to obtain the appropriate address (Any of Dip 1-9 ON ) for each unit. Flip appropriate DMX dip switches on each unit. The average operating temperature of the fog machine must be less than 250 degrees Celsius. (16)