Industry leading low energy evaporative fresh air cooling.

Similar documents
Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Case Study Leicester City Council

Case Study The University of Warwick

Repeatable IT Hub Rooms

Data Centre Solutions. Data Centre Solutions Expertly Engineered

APC by Schneider Electric Elite Data Centre Partner

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

Modular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered

Repeatable IT Hub Rooms

Total Modular Data Centre Solutions

Case Study Host Europe Group

Rack Colocation Hosting. Data Centre Solutions Expertly Engineered

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

Data Centre Optimisation Services

CASE STUDIES ENERGY EFFICIENT DATA CENTRES

Switch to Perfection

Thermal management. Thermal management

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

FREEING HPC FROM THE DATACENTRE

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

MEASURE MONITOR UNDERSTAND

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

A separate CRAC Unit plant zone was created between the external façade and the technical space.

Server Room & Data Centre Energy Efficiency. Technology Paper 003

Ecotel Free Cool 5-15kW

Green Sustainable Data Centres. Checklist - EU Code of Conduct on Data Centres. Annex

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Planning a Green Datacenter

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Engineering & Support Services

Green Data Centers A Guideline

Case Study: The design of a modern data centre Jeffrey Brindle Technical Director, HP Critical Facilities Services

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Scalable, Secure. Jason Rylands

Precision Cooling Mission Critical Air Handling Units

Planned Preventative Maintenance Schedule. Raised Access Floor PPM Schedule

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Taking The Heat Off University of East Anglia Data Centre

MSYS 4480 AC Systems Winter 2015

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Introducing the Heat Wheel to the Data Center

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Power Generation. Power Generation services deliver continuous and predictable power availability for 24/7 mission critical environments.

Ecoflair Air Economizers

Rack cooling solutions for high density racks management, from 10 to 75 kw

CASE STUDIES ENERGY EFFICIENT COOLING FOR THE PUBLIC SECTOR

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Data Centre Solutions Expertly Engineered APC Management Software

CLIMATE. CUSTOMIZED. CyberHandler2 from 30KW to 520 KW. The indirect evaporative free-cooling Air Handling Unit

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Avoidable Mistakes that Compromise Cooling Performance in Data Centers and Network Rooms

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

Indirect Adiabatic and Evaporative Data Centre Cooling

Rittal Cooling Solutions A. Tropp

Power and Cooling for Ultra-High Density Racks and Blade Servers

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

Defence Sector Solutions. Providing Next Generation Data Centre and Networking Infrastructure to the Defence and Security Sector

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Beyond BREEAM Excellent DCs. Cobalt Data Centre Campus

Overcoming the Challenges of Server Virtualisation

Data Center Trends: How the Customer Drives Industry Advances and Design Development

High Efficient Data Center Cooling

Next Generation Cooling

Data centre solutions - energy efficient by design

Close-coupled cooling

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

Virtualization and consolidation

ASHRAE IRELAND HVAC FOR DATA CENTRES. Michael Geraghty Building Services Engineer (DipEng) Company owner and managing director

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Five Best Practices for Increasing Efficiency, Availability and Capacity: The Enterprise Data Center Design Guide

Liquid Cooling Package LCP Cooling Systems

HIGH DENSITY RACK COOLING CHOICES

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)

Impact of Air Containment Systems

18 th National Award for Excellence in Energy Management. July 27, 2017

brightsolid Data Hall 1 Keysource Technical Specifications

IT Air Conditioning Units

Welcome Association of Energy Engineers to the Microsoft Technology Center

Indirect Adiabatic and Evaporative Data Center Cooling

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Liebert DCW CATALOGUE

ECOBAY: Closed loop water cooled server cabinet for data centers

IXcellerate Moscow One Datacentre - Phase 1 & 2 Overview

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Running Your Data Center Under Ideal Temperature Conditions

Munters Data Center Cooling Solutions. Simon Young & Craig MacFadyen Munters Data Centers

84 kw, Tier 3, Direct Expansion, 937 ft 2

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

ENCLOSURE HEAT DISSIPATION

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Data Center Energy Savings By the numbers

Transcription:

Industry leading low energy evaporative fresh air cooling.

Freecool Evaporative Free Air Cooling by Workspace Technology delivers innovative low energy cooling for a range of applications including data centre environments. Freecool offers clients a choice of direct and indirect airflow configurations. The optional Cool Wall module supports mechanical backup or top up cooling for all modes of system operation. Freecool installations are designed and built from scalable standardised modules that can be interconnected in a bespoke arrangement supporting real world client applications. Freecool delivers significant technical advantage over factory built single chassis alternatives that are very often cumbersome, expensive and difficult to deploy in many applications. Workspace Technology s Freecool can be installed as part of a new data centre or can be retrofitted and configured to work in harmony with existing cooling technology. Supporting rack densities from 1kW to 20kW Freecool is growing in popularity and has become the preferred cooling technology for many public sector and corporate organisations. Freecool deployment benefits include the following:- n Reduced CO2 Emissions n Significant Reduction of Energy Consumption and Operating Costs n Can Co-Exist with Existing Cooling Technologies n Delivers Industry Leading PUE* Energy Performance n Improved Resilience Through Optional Support via UPS Systems n Sustainable Product Assisting Clients Gain BREEAM and LEED Points/Credits n Flexible Design and Modular Architecture * Power Usage Effectiveness is the industry recognised metric for data centre room efficiency introduced by the Green Grid.

Unlike conventional monolithic packaged direct/indirect fresh air cooling solutions, Freecool by Workspace Technology delivers a truly flexible architecture. Freecool offers standardised modules that can be configured to create a bespoke cooling solution addressing individual client demands. With 30kW, 60kW, 90kW and 120kW modules, Freecool is designed to support a wide range (<30kW to >1MW) of data centre capacities. Primary System Modules... flexible design, modular & scalable architecture. Evaporative Cooler The Freecool Evaporative Cooler module is designed to pre-cool intake air during warmer ambient conditions. The Evaporative Cooler works on the simple principle of evaporative heat exchange. This process takes advantage of free latent heat which is generated as a result of water evaporation. The Freecool Evaporative Cooler is fitted with CELdek filter pads which help minimise water consumption by re-circulating water through the pump and automated drainage systems. Air Movement Freecool Air Movement module is based on industry leading EC fans which consume significantly less energy than conventional fan technology. Freecool systems are designed with a combination of intake and exit air fans supporting N or N+1 system configurations. Fan speeds are individually modulated via the Freecool Crouzet controller matching cooling demands and maximising system performance. Air Distribution The Freecool Air Distribution module interconnects core sub modules to channel Hot and Cold air streams within the data centre space. Freecool Air Distribution module consists of bespoke arrangements to support site specific air flow requirements. Air Distribution is created through a combination of ductwork, composite wall systems, floor and ceiling voids combined with aisle containment technology. Control Central to the operation of Freecool the Crouzet Control module manufactured by Schneider Electric is implemented with system sensors and site signal wiring. The Control module sits at the heart of the Freecool technology, configured to provide environmental control through the intelligent control of dampers and exit and intake air fans. Mixing Box Mixing Box modules support the Freecool Intelligent Atemperation mode which is designed to blend hot exit air with cold intake air to produce controllable equipment inlet temperatures irrespective of external ambient conditions. The Mixing Box module is configured with volume control air dampers (VCD) modulated via the Freecool Crouzet control system.

Freecool offers a number of configuration options, including indirect cooling through high efficiency heat exchange technology as well as mechanical backup or top up cooling. Optional System Modules Indirect & mechanical modes of operation. Heat Exchange The Heat Exchange module consists of a high efficiency cross air heat exchange system. The Heat Exchange module is designed to support indirect evaporative free air cooling. Passing cool external air through the Heat Exchange module removes latent heat from the data centre air stream. The Heat Exchange module allows data centres to benefit from the exceptional energy efficiency of evaporative free air cooling whilst maintaining a conventional closed loop eliminating the need for outside air to enter the data centre space. Cool Wall The Cool Wall module consists of a series of high efficiency chilled water coils that are typically positioned within the Freecool Mixing Box. The Cool Wall delivers an independent back up cooling circuit. The Cool Wall system offers automated backup cooling for both direct and indirect cooling options with start-up based on a range of configurable environmental conditions including fire, air quality, temperature and humidity.

Freecool Data Centre Innovations & Benefits Workspace Technology has developed an extensive and unrivalled expertise in data centre evaporative fresh air cooling technology following our first Freecool installation back in 2009. Through continued development and innovation Workspace Technology has successfully positioned Freecool as the evaporative free air cooling solution of choice for many data centre operators in the UK. Freecool offers data centre managers a range of innovations to improve performance and deliver industry leading PUE s. Dual Filtration Freecool Evaporative Free Air Cooling installations are configured as standard with a combination of G3 and G4 air intake filtration systems designed to eliminate data centre contamination. Intelligent Atemperation Freecool Intelligent Atemperation is designed to blend hot exit air with cold intake air, as a result this enables the system to deliver controllable equipment inlet temperatures irrespective of external ambient conditions. Atemperation is delivered through a combination of variable speed fans and volume control air dampers positioned within a Mixing Box and controlled via the intelligent PLC system. Dynamic Temperature Control Conventional closed loop cooling typically requires higher equipment intake temperatures to improve the performance of the free cool mode. The Freecool Dynamic mode of operation allows cold aisle/equipment inlet temperatures of 20 c for extended operating periods without compromising energy efficiency. Lowering equipment inlet air temperature will help reduce power demands of server fans whilst also improving overall equipment reliability*. When external ambient conditions rise above 20 c the Freecool Dynamic mode of operation simply allows the equipment inlet temperature to gradually rise falling back again as the external ambient decreases. *Results will depend on equipment age and type of fan. Fan Power Verses Inlet Temperature In Dynamic Mode the Freecool control system can also be programmed to ramp up/ down temperature (in-line with the rate of change parameters defined by ASHRAE) to ensure humidity levels are maintained within Class A1 Allowable data centre operating mode (8% to 80% RH). Reduced Fan Power Freecool only deploys EC fans because they use significantly less energy than conventional fan technology. EC stands for Electronically Commutated and is the term used when the fan is fitted with a Permanent Magnet Motor (PMM). EC technology allows continuous adjustment of fan speeds as required to support data centre cooling demands. The speed of each fan within the Freecool system is individually modulated via the Freecool Crouzet control system. Typically fan selections are oversized to support N+1 system resilience and to allow reduced speeds during normal operating conditions. Because motor power associated with EC fans varies with the cube of the motor speed any reduction in fan speed will result in energy reductions. As an example a 20% decrease in fan speed results in a 49% energy reduction. Benefits of EC Fans over Traditional Fan Technology Include: n Reduced Energy Consumption n Improved Noise Reduction n Intelligent Electronic Control

Approved Endorser EU Code of Conduct on Data Centre Efficiency APC Elite Partner Data Centre Certified Workspace Technology s Commitment to help clients reduce their carbon footprint through the deployment of energy efficient technology and design. Workspace Technology Limited Unit 10, Reddicap Trading Estate, Sutton Coldfield, West Midlands B75 7BU Tel : 0121 354 4894 Fax: 0121 354 6447 email : sales@workspace-technology.com www.workspace-technology.com Data Centre Solutions Expertly Engineered