Analog Interface Unit Operation Manual

Similar documents
3 Input Multiplexer Operation Manual

Installation & Operation

ProScale. Model 18W. Limited Edition. Model 18W

ProScale. Models 150, 250, 180, 280, 380 & 580 INSTALLATION

Holz-Her Sliding Table Saw Kit Installation Instructions: For 1243 Rip Kits

Installation & Operation

Paoloni Rip Kit Installation Instructions

Delta Unifence Kit Installation Instructions

Biesemeyer Fence Kit Installation Instructions:

Delta Unifence Kit Installation Instructions

Paoloni Rip Kit Installation Instructions

Shop Fox Fence Kit Installation Instructions:

Version Accurate Technology, Inc.

ProScale LCD Readout Quick Start Guide

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

TB-100 ControLynx Terminal Block

DCM Digital Control Modules

Model CD-AW. Infrared Environmental CO2 Sensor. Operator's manual

PMDX-105 Quad Isolator Board

PMDX-170 Slotted Optical Sensor

LCD Digital Readouts. 950, General Purpose, Basic & In-Panel OPERATION

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

SNT-E RT 10.4 VGA TFT with Touch Screen Display Module Powered By SegeNT embedded GUI Board Hardware Manual

LCI Load Cell Junction Box with Fault Monitor

FES LCD Display Version 1.1

PSI DITHERLESS BIAS CONTROLLER USER GUIDE

MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL

SA SERIES Arlingate Lane, Columbus, Ohio (614)

Proliphix EPA-60 Installation Guide

Sensoray Model 627 CompactPCI to PCI Adapter

Plus-X 300. Installation and Operation Manual

OP8/16 Optoisolated Digital Input Board User's Manual

ProTable. Operation Manual For ProTable Serial Number xxxxxxc

PRODUCT CONTENTS... 3 II. REQUIRED MATERIALS... 3 III. OVERVIEW... 3 IV. BENCH LAYOUT...

User Manual for Models

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

ACLD Channel Opto-isolated Digital Input Board

User Manual for: ProPanel-HD & -HDE

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

Resolver to Digital Expansion Board

General Purpose Input/Output (GPIO) Module Programmer s Reference Manual

TDM-170 TIMER DISPLAY

FNet Repeater Installation & Operator s Instruction Manual

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

V-9908 MESSAGE/PAGE PANEL

CF15118 CompactFlash Carrier utilitymodules User s Manual

LCI User Manual mantracourt.com

Grundfos MAGNA, GENI Module

TDM-150 TIMER DISPLAY

OZONE SWITCH Model OS-6. OS-6 Features

F²MC-8L FAMILY MB89201 SERIES FLASH PROGRAMMING 8-BIT MICROCONTROLLER APPLICATION NOTE. Fujitsu Microelectronics Europe Application Note

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge

LPG STM 94442A User s Manual

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option

AUTOMATION. Operator s Manual PG-5. Full Access. DOC Rev. A1 3/10

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

MD9 MULTIDROP INTERFACE INSTRUCTION MANUAL

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

INSTRUCTION MANUAL 4 UNIT AES SWITCH MODEL R198 S/N

BRG17088HR User's Manual PCI to ISA Bridge PC/104-Plus Module

I/O Expansion Box Installation & Operator s Instruction Manual

SeaLINK PIO-96 User Manual

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

FTC-200 X-ray Tube Controller Users Manual

XCD EDGE Evaluation Kit

TSD-DA28 2x8 Balanced Line Distribution Amplifier

Owner s Manual. TSD-ZDC Audio Impedance Combiner/Divider. TSD-ZDC Audio Impedance Combiner/Divider. AtlasIED.com

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation Manual. Flow Max 110

F2MC MB90385 series Evaluation Board Documentation. Revision Date Comment V New document

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

SOLVES-IT! 4 CHANNEL TIMER APPLICATION MODULE

Users Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

PIM-Mini Pulsed Current Source Operation Manual

6001TA Terminal Adapter Installation Instructions

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Embeddable Digital Video Recorder with Incremental Encoder Interface. Hardware Manual

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

Sensoray Model 623 PC/104+ to PCI Adapter. Revised December 19, Sensoray Model 623 Instruction Manual 1

CTI 2551-A 8-CHANNEL ISOLATED THERMOCOUPLE INPUT MODULE INSTALLATION AND OPERATION GUIDE. Version 1.3 CTI Part # * *


Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Owner s Manual. TSD-ZDC Audio Impedance Combiner/Divider. TSD-ZDC Audio Impedance Combiner/Divider

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Series ST. User s Guide DIGITAL TORQUE TOOL TESTERS. .com. Series ST Torque Tool Testers. User s Guide

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

CMT36106/3106/56106/5106 Hard Drive Carrier utilitymodule. User s Manual. BDM Rev. E

Brushless DC Motor Controller Specification Assembly 025A0053

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Sierra 80 Volt Brushless DC Motor Controller Product Specification

Transcription:

Analog Interface Analog Interface Unit Operation Manual

WARRANTY Accurate Technology, Inc. warrants the product against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon notification of a defect, Accurate Technology, Inc., shall have the option to repair or replace any defective part. Such services shall be the customer's sole and exclusive remedy. Expenses incidental to repair, maintenance, or replacement under warranty, including those for labor and material, shall be borne by Accurate Technology, Inc. (Including freight or transportation charges during the first 30 days). Except as expressly provided in this warranty, Accurate Technology, Inc. does not make any warranties with respect to the product, either expressed or implied, including implied warranties of merchantability or fitness for a particular purpose, except as expressly provided in this agreement. Accurate Technology, Inc. shall not be liable for any special, incidental, or consequential damages or for loss, damage or expense directly or indirectly arising from the customer's use of or inability to use the equipment either separately or in combination with other equipment, or for personal injury or loss or destruction of other property, or from any other cause. To request repair work, (either warranty qualified parts or not) follow the directions at www.proscale.com. A Returned Merchandise Authorization (RMA) number is required before returning any product for repair. SAFETY WARNING Before installing this product: Turn off and disconnect all power. SAFETY WARNING Accurate Technology, Inc. +1 828.654.7920 800.233.0580 828.654.8824 (F) www.proscale.com info@accurate-technology.com Manual P/N 800-1406-001 Copyright 2011 Accurate Technology, Inc. All rights reserved Revision C Accurate Technology Analog Interface Page 2 of 12

Table of Contents SECTION 1 GENERAL INFORMATION 4 INTRODUCTION... 4 BASIC THEORY OF OPERATION... 4 SPECIFICATIONS... 5 TERMINAL BLOCK... 5 MOUNTING... 5 MAKING CONNECTIONS... 6 SECTION 2 OPERATION 7 CALIBRATION AND POSITION LIMIT SETTING... 7 CALCULATING THE VOLTAGE PER STEP... 8 CALCULATING THE CURRENT POSITION:... 8 CONSIDERATIONS IN A/D CONVERSIONS... 9 PROGRAMMABLE OUTPUT... 9 RE-ESTABLISHING FACTORY DEFAULTS... 10 Factory Default Values... 10 POWERING A PROSCALE READOUT... 10 Manual Part # 800-1406-001 Page 3 of 12

SECTION 1 Introduction GENERAL INFORMATION The Analog Interface Unit, or AIU, is an interface device that provides the user of a ProScale measurement system with a method of generating an analog DC output voltage that is proportional to the currently displayed ProScale position. This output can be used with an A/D converter input on a PLC or other device that utilizes an analog input signal. Basic Theory of Operation The AIU converts the digital position signal from the ProScale Readout and compares it to an internal pre-programmed set of lower and upper position limits. The AIU uses a ratio utilizing these factors and generates an analog output via a 12-bit digital-to-analog converter. This provides 4096 discrete voltage steps over the defined measurement range. Accurate Technology Analog Interface Page 4 of 12

Specifications Dimensions: Power: Power connector: Input: Output: 2.75 x 3.38 x 2.27 In. (70 x 86 x 57 mm) 12-24 VDC @ 100mA (max) Terminal Screw Block Synchronous serial BCD (Mitutoyo Digimatic ) 0-5 or 0-10 VDC, 60 ma Terminal Block Position 1 Position 2 Position 3 Position 4 Position 5 Positive 12 to 24 VDC Ground Analog voltage output Ground Programmable output, active LOW (encoder failure or Readout SEND button) Mounting The AIU is mounted via a standard 35 mm wide DIN rail. This can be either 7.55 mm or 15 mm height. A quick release latch can be disengaged using a small flat screwdriver and pulling on the latch tab located on the bottom of the AIU housing Manual Part # 800-1406-001 Page 5 of 12

Making Connections NOTE: DO NOT APPLY POWER UNTIL ALL CONNECTIONS HAVE BEEN COMPLETED. 1. Connect 12 to 24 VDC to terminals 1 and 2. Terminal 1 is positive. Terminal 2 is ground and must share common ground with the PLC. 2. Connect the analog output terminals 3 and 4 to the analog input of the PLC or other control device. Terminal 3 is positive. Terminal 4 is ground. 3. Optionally, connect the programmable output on terminal 5 to a digital input of the PLC or control device. 4. Connect the 10 pin cable between the ProScale Readout SPC Output and the AIU Input. The cable connectors are keyed for proper alignment. 5. Remove the snap-on cover from the AIU by squeezing the sides of the top cover and set the analog output configuration jumper JP3 across pins 1 & 2 for 0-10 volts output JP3 across pins 2 & 3 for 0-5 volts output. 6. Optionally, install a jumper on JP2 for a supply voltage pull-up if needed on the output. If JP2 is left open, the AIU will provide a ground signal when an encoder fault/send button is active. When normal, the output is high impedance. If a jumper is installed on JP2, the normal output will be pulled up to the supply voltage via a 10K ohm resistor. 7. Apply power to the AIU. The two indicators should momentarily light up to indicate operation. If the ProScale Readout is connected properly, the status LED will illuminate. Accurate Technology Analog Interface Page 6 of 12

SECTION 2 OPERATION Calibration and Position Limit Setting Complete the following procedure to calibrate the ProScale and the AIU for position measurement. 1. Set the position offset of the ProScale Readout using the PLUS (+), DATUM and MINUS (-) buttons. See the ProScale user s manual for additional information regarding this procedure. 2. Move the Encoder on the scale to the point that will be the minimum position of travel. Press the Lower Limit pushbutton on the AIU. The limit switch activation LED will momentarily illuminate. 3. Move the Encoder on the scale to the point that will be the maximum position of travel. Press the Upper Limit pushbutton on the AIU. The limit switch activation LED will momentarily illuminate. The AIU is now calibrated with the ProScale Readout. When the displayed position is at or below the programmed lower limit, the analog output will be approximately 0 VDC (typically about 3-4 millivolts.) When the displayed position is at or above the programmed upper limit, the analog output will be at either 5 VDC or 10 VDC depending on the setting of jumper JP3. Displayed positions between the lower and upper limits will generate an analog output proportional to distance from the current position and the lower limit. NOTE: If the offset of the ProScale Readout is reconfigured, the AIU s upper and lower limits must also be reconfigured. Failure to do so will result in unexpected output from the AIU. Manual Part # 800-1406-001 Page 7 of 12

Calculating the Voltage per Step As stated earlier, a 12-bit digital-to-analog converter generates the analog output of the AIU. This yields 4096 discrete steps for the position range of the measuring system. To calculate the linear distance per step, divide the range of motion of the ProScale by 4096. For example: Lowest measurement position: 1.500 inches Highest measurement position: 7.750 inches Range of motion: 6.250 inches Distance per step =: 6.250 / 4096 =.00152 inches per step. Next, determine the voltage per step of the AIU. This depends on the analog output voltage range setting of JP1. JP3 set for 10 volt output yields:.00244 volts per step. JP3 set for 5 volt output yields:.00122 volts per step. If the AIU were generating an analog output of 2.999 volts with the voltage range set to 10 volts, the calculated position of the ProScale would be: 2.999 volts /.00244 volts per step = 1229 steps (rounded). 1229 steps x.00152 Inches per step = 1.868 inches. Calculating the Current Position: Starting position: 1.500 inches (set in Step 1 Calibration) + 1.868 inches (as calculated in the example above) = a new position of 3.368 inches NOTE: Rounding errors can have an effect on the calculations. The actual calculated position should have been 3.374 inches if rounding had not been used. The error is.17% Accurate Technology Analog Interface Page 8 of 12

Considerations in A/D Conversions The resolution of the A/D converter being used by the PLC or control device will have a direct impact on the measurement and conversion capabilities of the system. In the previous example, the voltage per step was calculated using the 12- bit resolution capability of the AIU. If the PLC or control device utilizes an A/D converter with a different resolution, then that resolution must be used. As an example, if the PLC s A/D converter resolution was only 10-bit, then the voltage per step would be: 10 volt range / 1024 =.00976 volts per step 5 volt range / 1024 =.00488 volts per step This results in less resolution capability and thus less position accuracy capability when calculating the ProScale Measurment System s position. In summation, the resolution of the PLC s A/D converter should be at least 12- bit or higher to provide maximum conversion accuracy. Programmable Output The AIU has a programmable output that can be used for either an encoder fault output or an output that activates when the SEND key is pressed on the ProScale Readout. When configured for Encoder Fault, the output of the AIU will transition low (ground) when the SPC signal from the Readout is interrupted. When configured for the Readout SEND button, the output will transition low for approximately 100 milliseconds when the SEND button is depressed on the ProScale Readout. This can be useful in signaling the PLC when a measurement sample is to be completed and/or recorded. The unit can be configured for either mode by the following: Encoder Fault output Jumper on JP5 to pins 1-2. Readout SEND Button - Jumper on JP5 to pins 2-3. Manual Part # 800-1406-001 Page 9 of 12

Limit Setting Switches Enable/Disable The limit setting switches can optionally be disabled once the limit positions have been set. This functionality is controlled by jumper JP4. Limit Setting Switches Enabled Jumper on JP4 pins 1-2. Limit Setting Switches Disabled Jumper on JP4 pins 2-3. Re-establishing Factory Defaults The AIU has the option of restoring factory default values in non-volatile memory if necessary. To activate this feature, complete the following: 1. Remove power from the AIU. 2. Depress and hold both the UPPER and LOWER limit switches while re-applying power. 3. Release the limit switches. Factory Default Values Lower Position Limit 0.000 inches Upper Position Limit 4.000 inches Powering a ProScale Readout You may power a ProScale Readout directly from the AIU via the SPC cable thereby eliminating the need for batteries in the Readout. To enable this feature, move the jumper JP4 inside the ProScale Readout to the External Power setting. Note: This feature is available only when using the General Purpose Readout. Accurate Technology Analog Interface Page 10 of 12

This page left intentionally blank Manual Part # 800-1406-001 Page 11 of 12

Thank you for choosing an Accurate Technology Product This product was proudly MADE IN USA Accurate Technology, Inc. 270 Rutledge Rd. Unit E Fletcher, NC 28732 USA 800 233-0580 828-654-7920 Fax 828-654-8824 www.proscale.com customerservice@accurate-technology.com Please register your system at: http://www.proscale.com/registration.htm This manual is available at www.proscale.com Manual P/N 800-1406-001 Copyright 2011 Accurate Technology, Inc. All rights reserved Accurate Technology Analog Interface Page 12 of 12