TT-NRM. Network Relay Module Installation Instructions WARNING:

Similar documents
NGC-40-BRIDGE CONTROL AND MONITORING MODULES FOR USE WITH THE RAYCHEM NGC-40 SYSTEM INSTALLATION INSTRUCTIONS

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

NGC-40-BRIDGE. Control and Monitoring Modules for use with the nvent Raychem NGC-40 System Installation Instructions

ACS-30-EU-MONI-RMM2-E

The max number of C910 controllers is 8 per ProtoNode.

TRC-190 User s Manual

TRC-190 User s Manual

S-series Horizontal Carriers

INJ-24A Series Quick Installation Guide

DeltaV Bulk Power Supplies

FLEX Ex Spring Clamp Terminal Base

User Interface Terminal for nvent RAYCHEM NGC Systems Installation Instructions DESCRIPTION TOOLS REQUIRED. Nonhazardous Locations LR67275

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

PXC Compact Unitary Equipment Controller (UEC)

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

PS/IO Circuit Board Retrofit

Classification Enclosure rating Input voltage Type of

S-series Mass Connection Solutions

DeltaV Bulk Power Supplies

Ethernet Adapter Installation Instructions

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

H3C S12500 Routing Switch Series

Component identification

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Model 2380 Rack-Mount Kit

To connect the AC adapter:

nvent RAYCHEM NGC-40 SYSTEM OVERVIEW

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Operation and Maintenance Manual

Installation Instructions

Installation and Maintenance

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE

Surge Protective Devices. STV25K Series. Instruction Manual

CS XL XM. EcoSystem Bus Supply

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

DeltaV M-series I/O Subsystem Horizontal Carriers

MOXA EtherDevice Switch & PoE Splitter

6222 Two Door Module Technical Operations Manual

Model 2380 Rack-Mount Kit

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

EP/2 Installation Instructions

Dell SC460 Expansion Enclosure Getting Started Guide

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

S-series Horizontal Carriers

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Overview These instructions are presented as a guideline for installing and setting up the LX Series Breaker Control Panel.

H704-42(H)(E), H704-42/1(H)(E)

IO-DI8-RO4, IO-DI8-RO4-L I/O Expansion Modules 8 Inputs, 4 Outputs

PC9/P9 CPU Card Replacement

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

SER-4485-SI-M USER S MANUAL

Installing the DX LCD Display

IBM. Rack Installation Instructions

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Description. Green. Red. Orange

Rack Installation Instructions

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Installation & Operation Guide

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

Open Processor with Square D Driver

PowerFlex 700L Liquid-to-Liquid Heat Exchanger Control Board Replacement

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

EA500. Installation Instructions Transponder

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

INSTALLATION INSTRUCTIONS

Installation Notes TII Model 341 Protector

SAVE THESE INSTRUCTIONS

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Analog Voltage Combination Module

System Storage EXP3000 Rack Installation Instructions

PM Series Power Meter

A-100G6 - Basic frame assembly diagram

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

Screen 2.4" 3.5" Color Touch 4.3" Color Touch. RS232/485 Yes Yes Yes Yes Yes* USB device, mini-b Com Ports, separate order, user-installed

Rack Installation Instructions

EDS-G308 Series Quick Installation Guide

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

PowerFlex DC Drive - Frame A SCR Modules for Drives with a Power Traces Circuit Board

Installing a Power over Ethernet injector

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

EX-RC1 Remote I/O Adapter

PT-7728/7828 Quick Installation Guide

PTC-101 Quick Installation Guide

PLC Racks IC697CHS782/783

EX-RC1 Remote I/O Adapter

Surge Protective Devices. STV100K Series. Instruction Manual

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

SMS 4 / SMS 5 safety mat Product information

Surge Protective Devices. STV100K Series. Instruction Manual

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Quick Start Guide TS A

SCv360 Expansion Enclosure

Submittal Data Sheet WAGO Node for itm

Content. Product Description

Installation Instructions

Transcription:

TT-RM etwork Relay Module Installation Instructions TT-RM-BASE unit with four TT-RM-2RO modules removed Description The TraceTek etwork Relay Module provides multiple relay outputs for switching alarm or control devices for the leak detection system. TT-RM units are modular and may be configured with 2 to 32 relay outputs. A single TTDM-128 unit communicates with up to up to 20 RMs over a single, twisted pair RS-485 cable. I/O RU I/O ERR 750-312 Additional Materials Required TT-RM-2RO, 2-channel relay output module (marked 750-517) [up to 15 additional modules may be added to one TT-RM-BASE] RS-485 cable, 1 shielded twisted pair [TT-RS485-BUK or equivalent] Suitable enclosure or panel Additional wire, as necessary Tools Required 3.5-mm flat-blade terminal screwdriver Wire stripper/cutter Approvals Kit Contents TT-RM-BASE: 1 etwork processor (marked ) 1 24 Vdc power supply (marked 5101-7663) 1 Relay output module (marked 750-517) 1 End termination module (marked 750-600) 1 RS-485 network connection module 1 Ribbon cable with screws 1 DI 35 rail for mounting 1 Ground terminal 2 DI rail end stops Reference Documents TTDM-128 Installation Manual (H57341) TTDM-128 User Manual (H56583) Specifications Function Provides relay outputs to switch power to contactors under control of the TTDM-128 Ambient operating range 0 C to 55 C (32 F to 130 F) Ambient storage range 40 C to 60 C (40 F to 140 F) Relative humidity 5% to 95%, noncondensing Supply voltage 94-264 Vac Supply current 60 VA max. Relay output type Mechanical, normally open, voltage free Relay output rating 230 Vac, 30 Vdc, 2 A max. Communications RS-485, single shielded twisted pair, max. 20 RM units per network Connection terminals 2812 AWG (0.082.5 mm 2 ) WARIG: This component is an electrical device. It must be installed correctly to ensure proper operation and to prevent shock or fire. Read and carefully follow these important installation instructions. THERMA MAAGEMET SOUTIS E-TraceTekTTRM-IM-H57474 01/13 1 / 8

TT-RM System ayout The TTDM-128 controls up to 127 circuits of leak detection. TT-RM units switch external alarm or control devices. RMs are connected to the TTDM-128 unit via a single RS-485 network. TTDM 128 TT-RM TT-RM Assembly 1 etwork processor (marked ) 2 2-channel relay output module(s) (marked 750-517) [up to 16 total modules allowed per processor] 3 End termination module (marked 750-600) 4 DI 35 rail 5 Address switches 6 RS-485 ribbon cable 7 RS-485 network connection module 8 24 Vdc power supply 9 Ground terminal bk End stops 750-517 750-517 750-517 750-517 750-600 THERMA MAAGEMET SOUTIS E-TraceTekTTRM-IM-H57474 01/13 2 / 8

Overview of installation procedures for TT-RM A. Mount TT-RM assembly in enclosure selected for the application. B. Connect power and relay contact wiring. C. Connect RS-485 cables and set address. D. Update the TTDM-128 network. A. Mount DI rail 1. Select a location for installation. The TT-RM may be installed in any panel or enclosure suitable for electronic control devices. The TT-RM assembly is powered with line voltage and switches relay contacts that may be connected to line voltage. Select an electrical panel or enclosure considering the area classification (i.e., non-hazardous or hazardous), the location (indoors or outdoors, exposure to moisture and/or dust), and the chemical environment. If ambient temperatures below freezing are expected, install the TT-RM unit in a heated location or use an enclosure heater. If moisture is expected, install a drain in the enclosure. 2. Size and install DI rail. Use the supplied DI 35 rail. The rail may be shortened if necessary. The width of the TT-RM assembly is determined based on the number of TT-RM-2RO relay modules used. 38 mm (1.5 in) 38 mm (1.5 in) 45 mm (1.75 in) 12 mm (0.5 in) 12 mm (0.5 in) 100 mm (4 in) 750-517 750-517 750-517 750-600 35 mm (1.4 in) Power supply RS-485 network connection module etwork processor Relay module End termination Overall width: = 157 mm 12 mm per relay module = 6.25 in 0.5 in per relay module THERMA MAAGEMET SOUTIS E-TraceTekTTRM-IM-H57474 01/13 3 / 8

750-312 B. Install TT-RM assembly 1. Attach the TT-RM components to the DI rail The TT-RM-BASE comes assembled. To remove a module, pull up on the orange release tab until the module releases from the DI rail. Do not remove modules while power is on. To install additional TT-RM-2RO relay modules, you must first remove the End termination module (3) and the adjacent DI rail end stop. Slide the additional relay modules into place and ensure they snap on to the DI rail. Replace the End termination module and DI rail end stop to the right of the last relay module added. Refer to the TT-RM Assembly diagram on page 2 for the proper order of module assembly. Important: Modules and/or external equipment may be damaged if modules are not installed in the correct sequence. Orange tab 2. Attach the RS-485 network connection module to the DI rail. ocate the module to the left side of the etwork processor. Press the module down onto the DI rail to lock it in place. Connect the supplied ribbon cable between the etwork processor and the RS-485 connection module. Use the screws provided to secure the ribbon cable connectors. 3. Mount the power supply. Mount the power supply on the DI rail to the left of the RS-485 network connection module. I/O RU I/O ERR THERMA MAAGEMET SOUTIS E-TraceTekTTRM-IM-H57474 01/13 4 / 8

C. Connect power wiring ote: TT-RM units use cage-clamp spring terminals for secure wire connections. Review the steps at right for using this type of terminal. ote: Strip length for wires in terminals is 10 mm (3/8 in). Using Terminals Insert flat-blade screwdriver into square hole. Rotate and push the screwdriver firmly to open the spring. Insert stripped wire into round hole. Remove screwdriver. 1. Connect 24 Vdc wiring. 24 Vdc supply must be connected to the etwork processor module. Connect wires from the power supply output to the terminals shown. Connection terminals on TT-RM module accept 2812 AWG (0.082.5 mm 2 ) wire. 01 02 15 16 POWER SUPPY 750-517 750-517 750-600 2. Connect line voltage supply. Connect line voltage and ground to the input of the power supply as shown. 01 02 15 16 POWER SUPPY To AC supply 750-517 750-517 750-600 ote: Previous wiring omitted for clarity THERMA MAAGEMET SOUTIS E-TraceTekTTRM-IM-H57474 01/13 5 / 8

3. Connect wiring to relay contacts. Connect the external alarm or control devices to the terminals on each TT-RM-2RO 2-channel relay output modules as shown. Up to 16 TT-RM-2RO's per network processor 01 02 15 16 Status relay 1 15 16 Status relay 2 POWER SUPPY /O /O Common /C Common /C 750-517 750-517 750-600 750-517 ote: Previous wiring omitted for clarity Common (line) eutral /O /C oad THERMA MAAGEMET SOUTIS E-TraceTekTTRM-IM-H57474 01/13 6 / 8

D. Connect RS-485 cables and set address 1. Select the RS-485 address for the TT-RM unit. Each TT-RM connected to a TTDM-128 must have a unique address in the range 1 to 99. If two TT-RM units are assigned the same address, communications faults will result. To ensure you assign an unique address to each TT-RM unit, review the system layout. If a layout document does not exist, create one. Assign an unique address to each TT-RM unit. ote: TraceTek TTSIM modules are connected on the same RS-485 network and must not have the same address as any TT-RM. 2. Set the RS-485 address for the TT-RM unit. Use a small flat-blade screwdriver to rotate the address switch marked x1 to the desired address. For an address of 50, set the x1 to 0 and the x10 to 5. Set address 0-9 Set 10's digit of address 3. Connect RS-485 cables. ote: Do not make connections to the RS-485 bus while it is connected to an operating TTDM-128, or damage and/or alarms could result. The RS-485 bus allows units with unique addresses to be daisy-chained together along a common bus. To add a new unit to the network, simply daisy-chain the RS-485 bus from the last unit to the new one or insert the new unit between two existing units on the bus. The order in which units are attached to the RS-485 bus does not matter. There are just two constraints on the RS-485 network: Each TT-RM must be assigned a unique address. The RS-485 bus must be a continuous string from the first unit to the last unit in the system. ote: The RS-485 bus operates at 5 V, and equipment connected to it could be damaged by exposure to higher voltages. Take precautions to avoid exposing the RS-485 wiring to discharge of static electricity or other sources of high voltage potential; in particular, avoid contact with the power supply wiring. 1 Connect the clear or white wire of the RS-485 cable to the () terminal as shown. 2 Connect the black wire of the RS-485 cable to the () terminal as shown. 3 Connect the shield wire of the RS-485 cable to the shield terminal as shown. If connecting two RS-485 cables (one I and one OUT), use the same terminals for both wires. Important: Do not connect the shield of the RS-485 cable to the enclosure or panel grounding terminal. Connect the shield only to the terminal provided. To avoid the potential for spurious ground loops, the RS-485 cable shield should be connected to ground only in the TTDM-128. POWER SUPPY 3 1 2 750-517 750-517 750-517 RS-485 ote: Previous wiring omitted for clarity THERMA MAAGEMET SOUTIS E-TraceTekTTRM-IM-H57474 01/13 7 / 8

E. Update the TTDM-128 etwork TT-RM units are controlled by a central TTDM-128. The Update etwork Function in the TTDM-128 software must be triggered in order for the TTDM-128 to recognize new or changed TT-RM units. Until this software function is run, the TTDM-128 will not control new TT-RM units. 1. Energize all TT-RMs in the network. Confirm that the RS-485 network is complete (all TT- RM and TTSIM units and the TTDM-128 are connected to the RS-485 bus), and that the power to each unit has been turned on. 2. Use the TTDM-128 system software to update the network. ote: When the TTDM-128 is first powered, it automatically runs the Update function. Run the TTDM-128 Update etwork software function to trigger it to recognize new TT-RMs. The TTDM-128 User Manual (H56853) describes this software function in detail. Power on Communications 3. If necessary due to problems or questions, check function of individual modules. Verify that a TT-RM is functioning by confirming that the power ED is illuminated. Check all connections. Check that all TT-RM modules are securely seated on the DI rail. Confirm that the TT-RM network does not have any duplicate RS-485 addresses. Individual relays can be checked using TTDM Self-test/ RM Relay test. WWW.THERMA.PETAIR.COM ORTH AMERICA Tel: 1.800.545.6258 Fax: 1.800.527.5703 Tel: 1.650.216.1526 Fax: 1.650.474.7215 thermal.info@pentair.com Europe, Middle East, Africa Tel: 32.16.213.511 Fax: 32.16.213.603 thermal.info@pentair.com Asia Pacific Tel: 86.21.2412.1688 Fax: 86.21.5426.2917 cn.thermal.info@pentair.com atin America Tel: 55.11.2588.1400 Fax: 55.11.2588.1410 thermal.info@pentair.com Pentair and TraceTek are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. 2003-2013 Pentair. THERMA MAAGEMET SOUTIS E-TraceTekTTRM-IM-H57474 01/13 8 / 8