GSM controller module for SMS remote monitoring, alarming and control applications BR900-ST. Preliminary data. GSM module BR900-ST.

Similar documents
GSM/GPRS GPS Tracker for real-time GPS data tracking BR900-GPS

GSM Controller BR160SM-Sd BR161SM-Sd V1.2

GSM Controller BR160SM-2FLOW-4A-A / BR161SM-2FLOW-4A-A Preliminary data

Power Supply. SIM Card. LED indicators

GSM Controller BR160SM-2SMT-4A-A / BR161SM-2SMT-4A-A

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

DinBox M36 Hardware Description Guide

LAUREL ELECTRONICS, INC.

AT200V3 Vehicle Tracking Device. Version 3.x Hardware. User Guide

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

RN-174 WiFly Super Module

EZ864 UMTS Terminal Telit Cellular GSM Engine

GSM HOME SECURITY SYSTEM

RN-174. WiSnap M2 Super Module. Features. Description. Applications. ~ page 1 ~ rn-174-ds v1.1 6/1/2011

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

Technical Documentation, RTCU-SA

Technical Manual for RTCU M10 / M10G

GT- IRDM-9603 Product description Rev. 2 17/06/2014

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723

icex-cmtm General specs and Installation guide

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

GNS-MC35iT, GNS-MC35iU Terminals datasheet

User Manual Revision 1.02

RN-134. WiFly GSX Super Module SuRF Board. Features. Description. Applications. ~ page 1 ~ rn-134-ds v1.

WI-I/O 9 Multi I/O Units

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 1/24/2011

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 4/20/2011

NX21 USER MANUAL. Telemetry Unit. Version 1.5

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

RN-171-XV b/g Wireless LAN Module

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GSM communicator GD-06 Allegro Complete manual

Hardware Interface Description

RN-174. WiFly GSX Super Module. Features. Description. Applications. rn-174-ds v1.1 3/3/2011

DATA LOGGER GEOLOGGER G8 PLUS

RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming

Technical Manual for the RTCU M11i Series

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs

QUADIMODO. Quad-Band IP68 GSM MODEM. Quad Band for Worldwide Use. IP68 Enclosure Submersible. Voice / Fax / SMS and Data. GPRS Class B Class 10:

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS

A1000 GSM ALARM DEVICE

AVL Tracking System TR-600

ELC2212X user manual

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

1 Introduction Required components Datalogger TrueLog Baseboard... 1

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

The JT-DO1 GPS-disciplined IRIG-B timecode generator produces timecode according to the IRIG-

EZmoto V4.1 Product description Rev. 2 30/07/2015

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

Tu Sitio de Automatización!

Netbiter EC300 Series

UP100-GSM. GSM based intercom and access control. Installation and user manual

IntesisBox SMS - Mitsubishi Electric air conditioners

ZETA Series 2G/3G/4G Modems with GPS Option

GSM Modem 5. Installation and User Guide. English

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Module Technical characteristics

TG Technical specifications

WIRING DIAGRAMS NVIROMON NDCNTRLRS485. Remote Environmental Monitoring and Control for IT equipment. NVIROMON

QUICK GUIDE for 4 modules. Installation

FIFOTRACK MOTORCYCLE/VEHICLE GPS TRACKER

Four-Faith Smart Power Technology Co., Ltd. F1103 GPRS MODEM USER MANUAL

ZETA Series 2G/3G/4G Modems with GPS Option

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

GSM/GPS/GPRS Vehicle/Motorcycle Motorbikes Tracking. User Manual V7.0

Innovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

TECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1)

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

FIFOTRACK VEHICLE GPS TRACKER. Model: A300 Version: V1.1

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

GSM SECURITY AND CONTROL SYSTEM ESIM021

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

Expansion Module HZS 541-1S

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

GPRS Pager 3 INSTALATION AND USER MANUAL

OnCell G3100 Series Quick Installation Guide

FIFOTRACK VEHICLE GPS TRACKER. Model: S30 Version: V1.1

USER MANUAL Mobeye Smoke Detector CM2400 Mobeye Heat Detector CM2400H. SW version 3.n

UCM 94/1 3G/GPRS Modem for RTU32 Series

MOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F)

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

LAUREL ELECTRONICS, INC.

GS828-H. GPRS Data Logger

QTech SMS Lite Quick Start Guide

SENECA s.r.l. Commercial

StarFinder Aire User Manual

Hardware MCST Technical Manual W E CREATE MOTION

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

Open gates & doors with your mobile phone.

Transcription:

GSM controller module for SMS remote monitoring, alarming and control applications BR900ST Preliminary data Introduction The BR900ST controller is a low dimensions low cost GSM communications device that used for wireless alarming, monitoring and control of remote equipments and systems. Multiple users can interrogate the BR900ST notified on configurable events. The builtin GSM module compatible with dualband (900/800Mhz) or quadband (850/900/800/900Mhz) GSM networks. You can use a mobile phone to monitor the status of equipment or system, receive notification of events, send control commands to remote equipment, receive information of controlled object to your mobile phone.

Features Dual or Quad band GSM module SIM900 or compatible digital inputs analogue input Solid State Relay outputs (30V/0.5A max) optionally (30V/0.5A max) OpenDrain Mosfet Outputs instead of SolidState Relay outputs Onboard power supply voltage monitoring Remote programming using SMS User definable input alarming text descriptions Pluggable screw terminal block for external signal connections PushPush SIM holder External stabilised +6...VDC (.5V max) Board dimensions: 50.5x77.5mm Enclosure: FISCHER ELEKTRONIK AKG 55 80 ME (optional) Applications: Pumping Transformer Station Base Stations Power Generator Refrigerator Wasterwater Treatment Station Unmanned Equipment and System BR900 Versions BR900ST Standard version BR900SMT Temperature monitoring version BR900PT00 Temperature monitoring version for Pt00 sensors BR900RF RFcontrol version for wireless remote control switch AC power plugs BR900GATE Gate opener version for Gate control BR900GPS GPS version for position tracking BR98DL Data logger version with extended inputs and outputs and with GPRS data transfer to WEB server

SMS Function SMS controller send an event SMS messages to up to 3 cell phones. Any cell phone can be used to send SMS commands to BR900. Mobile users can contact and request information from a BR900 GSM controller and up to users can receive notification of events. With the BR900 GSM controller you can use a mobile phone to: Monitor the status of equipment or systems Send control commands to remote equipment Receive notification of events to your mobile phone or WEB server (data logger version) Any BieneRemote GSM controller can be used to send SMS commands to other BieneRemote GSM controller for remote control. Any BR900 GSM controller can be programmed via SMS instruction. Input Signal Monitoring The BR900ST has digital inputs that can be configured as: 0 or 0 event input two inputs connect with pullup resistor to module power supply To receive SMS message by event on inputs, you need enter SMS message on a module (or SIM card) programming. The BR900ST has analogue input. 00V 0 bit resolution Analogue Input additional implemented onboard power supply voltage monitoring 5.5V maximum You can set minimum and maximum analogue signal threshold as events. Output Control The BR900ST has Solid State Relay outputs (30V/0.5A max) Optionally (30V/0.5A max) OpenDrain Mosfet Outputs instead of SolidState Relay output. These may be controlled with SMS messages from approved users. To set any output as you like, you need only to send an SMS message. Module to Module Control The BR900 supports ModuletoModule management with SMS command. Users and Administrator The BR900 supports up to 3 users. Each user can interrogate the device for the current I/O status. Users can be notified based on changes to each input. 3

Security The BR900 has a number of inbuilt security features. Caller ID security provide authentication for device interrogation and control. Alarm SMS messages can be sent to users when an input reaches an alarm state. The following setpoint configurations are available: Alarm when 0 or 0 event at digital input. Alarm when above set point at analogue input. Alarm when below set point point at analogue input. Alarm when inside set points point at analogue input. Module Programming/Configuration The BR900 can be configured (programming) remotely with SMS command. Configuration options include Alarm Message Content, Users and Administrators Phone Numbers and other.

Technical Specification BR900 series Hardware Specification BR900ST GSM band support Internal GSM module RF Transmit Power Data transmission SIM card reader SIM card type Antenna Connection Digital inputs Digital inputs type Digital inputs Events digital inputs Digital inputs event Digital signal filter Temperature sensor inputs Temperature sensor Temperature inputs Temperature input events Temperature range Accuracy Temperature filter Analogue inputs Analogue inputs Analogue input range Analogue input mode Analogue input events ADC resolution Outputs Relay Output SMS BR900SMT BR900RF BR900GATE BR900GPS 800/900Mhz or 800/850/800/900Mhz Dual or Quad band GSM module SIM900 or compatible Class (W) 850/900Mhz, Class (W) 800/900Mhz SMS SMS SMS SMS/FTP/GPRS Pushpush Phase and phase +; SIM 3V /.8V 50Ω SMA (f) Connector MOSFET transistor input (0V max) 0 or 0 0 or 0 SMT6030 min/norm/max 5 to +99 C.7 C (.5 C) 0 or 0 0 and 0 BR98DL SMS/FTP/GPRS Simple Darlington transistor input 6 0 and 0 SMT6030 min/norm/max 5 to +99 C.7 C (.5 C) 0...0V 0...0V 0...0V 3 00V 05V/00V min/norm/max min/norm/max min/norm/max 00mA (optional) min/norm/max 0bit 0bit 0bit 0bit (5Vac/Vdc/0.5A Solid State Relay outputs MOSFET Open Drain outputs Wireless Outputs (AC remote switch control) Output control mode Onboard monitoring Power supply voltage monitoring Power supply voltage monitoring range Temperature monitoring Temperature range (30V/A max) (30V/A max) (30V) optionally instead of SolidState Relay output (30V) optionally instead of SolidState Relay output (30V/A max) (30V/A max) (30V) optionally instead of SolidState Relay output (30V) optionally instead of SolidState Relay output (0V) Up to 5 OnOff; Pulse 5.5V max 5.5V max 5.5V max 5.5V max 5.5V max 7.75V max 0 to +85 C 5

Wiring Wiring Connections Power Supply Required Power External Supply Power requirement Minimum current recommended Voltage regulator Power protection Environmental Conditions Operating temperature range Dimensions Board dimensions Enclosure Enclosure Enclosure dimensions BR900ST BR900SMT BR900RF BR900GATE BR900GPS BR98DL 0way Pluggable Screw Terminal block 0way Pluggable Screw Terminal block 5.5/. power connector; way pluggable screw terminal 0way Pluggable Screw Terminal block 0way Pluggable Screw Terminal block x0way Double row pluggable Screw Terminal block +6..Vdc (.5Vdc max) stabilised +5Vdc stabilised +5Vdc stabilised +6..Vdc (.5Vdc max) stabilised +6..Vdc (.5Vdc max) stabilised.a +Vdc stabilised (+Vdc min +.5Vdc max) 50mA typ, 50mA(rms) max, A peak typ. (3A max) peak during transmission A A.A.5A.5A Internal voltage regulator Reversepolarity and overvoltage protection 0 +85 C optional aluminium 80x55xmm aluminium 80x55x 77.5x50.5mm optional aluminium 80x55xmm optional aluminium 80x55xmm optional aluminium 80x55x3 BR900ST BR900SMT BR900RF BR900GATE BR900GPS BR98DL () () 5 () () 3 Quantity of digital event inputs 6 Quantity of analogue event inputs Quantity of readable analogue data Quantity of temperature event inputs Quantity of readable temperature data (+power supply voltage) (+power supply voltage) power supply voltage (+power supply voltage) 3 (+power supply voltage) 0 0 optional aluminium 80x55xmm BR900 series Firmware Specification Quantity of controlled outputs Events cell phone numbers 6 6 7

Hardware The BR900ST module consists of the microprocessor, voltage regulator, inputs driver, MOSFET output transistors, builtin GSM module, pushpush SIMcard holder, GSM antenna connector, pluggable 0ways screw terminal for external power supply and input and output signal connection. 7

8

Power Supply The BR900ST operates from a stabilized power source. It draws less then 50mA standby, less then 300mA rms and A peak typ. (3A peak max.). +VDC/.A min switching stabilized power supply is recommended. Power supply input has reverse polarity and overvoltage protection. The BR900ST can operates also from 6VDC to up to.5vdc stabilized power supply. SIM Card Small SIMcard with 3V/.8V technology Preparation of SIM card.. 3. Delete any SMS messages from SIM. Disable PIN code request so it will not prompt for a PIN code on turning on. First SMS to module 35N from your cell phone (store your number) Note: The BR900 can only be used with small SIMcards with 3V/.8V.technology. For SIM card preparation you can use cell phone or external GSM modem. SIM card change if power turn off. LED indicators Module status indication RED LED (LED) GSM module SIM900 status indication GREEN LED (LED) Module LED indication (Red LED) LED status Modem status Permanently off Short blinking after power on Short periodic blinking Permanently on Device off SIM card read process Module in work Module work with modem GSM Module SIM900 LED GSM status indication (Green LED) LED status Modem status Off 6ms On / 800ms Off 6ms On / 3000ms Off 6ms On / 300ms Off GSM module SIM900 is not running GSM module does not find the network GSM module find the network GPRS communication 9

Connectors and Jumpers The BR900ST consist 0way pluggable screw terminal for power supply, inputs and outputs connection, pushpush SIM connector for SIM card, SMA (female) connector for GSM antenna connection and optional MMCX (female) connector for MMCX(male)SMA(female) cable for GSM antenna connection. Optionally BR900 have also x8 pin header (X) and x pin header (X) for additional extended adapter board connection. X GSM antenna SMA (female) connector X Pushpush SIM connector X3 Pluggable 0ways terminal block for power supply and external inputs/outputs signal connection X, X Pin headers for optional extension adapter board connection X5 optional MMCX (female) connector for MMCX to SMA bulkhead GSM antenna cable for any other enclosure X7 ISP interface connector for Firmware programming X8 control point J/J Jumpers for firmware mode setting J3 Jumper for connection INPUT to GND. Power Supply: Digital Inputs: Analogue Input: Digital outputs: see Power supply NTR003N MOSFET transistor 00V max) 0...5.5 max with resistive divider and diode protection Solid State Relay outputs, 30V max / A max 0

Jumpers Jumper J not used Jumper J Set default password 35: set jumper power ON after 5sec power OFF remove jumper GSM antenna connector GSM antenna must be connected to SMA female connector X. Use only the 50Om antenna of the necessary frequency range. Base version completed with direct mount GSM antenna. Optional X5 MMCX female connector used for connection MMCX(m) to SMA(f) cable for mounting to any other enclosure. Note: It is very important that the antenna is installed on a location where the GSMnetwork coverage is sufficient. Please also check carefully that antennas are not installed nearby technical devices, cables etc. which could influence the GSMradiation. Inputs and Outputs connection Digital inputs, analogue input, outputs and power supply must be connected with pluggable screw terminals blocks X3. Digital inputs Analogue inputs Solid State Relay outputs See Inputs and Outputs

Inputs and Outputs Inputs Digital Transistor Inputs Driver type: MOSFET transistor NTR003 Connector: Pluggable screw terminal block Inversion: Max input voltage: 0V Free Input: logic "0" Logic "0": 0V +V Logic "": +V +0V Pullup resistor: 5k only for INPUT3 and INPUT INPUT and INPUT without pullup resistors Analogue Inputs Connector: Pluggable screw terminal block (for analog input) Input type: CMOS Input Voltage: 0 to +0V: ANALOG ADC resolution: 0bit Outputs Solid State Relay Outputs Connector: Pluggable Screw terminal block Solid State Relay: singlepole, normally open (FormA) Solid State Relay CPC00N Max. Voltage: 30V Max. Current: A Onresistance: 0.5om MOSFET Open Drain Outputs (optional) Connector: Pluggable Screw terminal block MOSFET transistor: IRL637PBF Max. Voltage: 30V

Connection Example Connection example to Input Driver 0 and 0 event notification You can use J pin header for inboard pullup resistor connection. Connection example to MOSFET Open Drain Output Electromechanical relay connection Relay Module connection Solidstaterelay (SSR) connection 3

Enclosure For all BR900 version used Fischer Elektronik aluminium enclosure AKG 55 80 ME. BR900 Board dimensions: 50.5x77.5mm Enclosure AKG 55 80 ME dimension 5 x 80 x mm

Programming Digital signal monitoring Open input Connection to Connection to Event GND Power supply all 0 Event all 0 Digital input '0' '0' '' 0 0 Digital input '0' '0' '' 0 0 Digital input 3 '' '0' '' 0 0 Digital input '' '0' '' 0 0 Event 0 or 0 selected with SMS command 35V0 and 35V Analogue signal monitoring Analogue input and supply voltage monitoring (default setting) Analogue input Analogue (internal) = Supply Voltage Minimum setpoint 00% 70% Maximum setpoint 00% 00% (setpoint disable) +5V 3.6% 3.6% +0V 6.5% 6.5% +0.85V 70.00% 70.00% +V 77.% 77.% +5,5V 00% 00% Can set minimum and maximum setpoints in % ( for Analogue and Analogue ). Analogue signal (in %) 0% MIN level < MIN MAX level NORMAL 00% > MAX For supply voltage monitoring Alarm text SMS constantly: Voltage low Voltage normal Voltage high 5

SMS command Digital and Analogue signal monitoring SMS command Text (length 6 characters) Default text 35X0,text Input event 35X,text Input event 35X,text Input event 3 35X3,text Input event 35X,text Analogue low 35X5,text Analogue normal 35X6,text Analogue high 35X7,text (not used) 35X8,text (not used) 35X9,text (not used) Note If first character in text space, then disable alarm SMS for this event SMS command Answer SMS Function 35I Read status SMS 35N 35N 35N3 35N Set up to cell phone numbers for alarm SMS at position.. Send SMS without number from cell phone,,3, 35C 35C 35C3 35C Clear number,,3 or Send SMS from any cell phone 35P00 Passw: 00, 00 new password Change password; default password 35 If forgot password, you can with jumper J restore default password 35. Set jumper J, power ON, wait 50 sec, power OFF, remove jumper J Note: J jumper for set password default = 35 35S 35S (optional) Set output Set output (optional) 35R 35R (optional) Reset output Reset output (optional) 35S3 Output sec pulse 35E 35E0 35E Enable alarm SMS, default enable Disable alarm SMS Disable alarm SMS 35V 35V0 (or 35V) Digital event 0 Digital event 0 6

35M,0 35M,30 : Set minimum analogue setpoint, Analog default: 00 (no event) Analog default: 75 35A,60 35A,00 : Set maximum analogue setpoint, Analog default: 00 (no event) Analog default: 00 (no event) Reference voltage =.56 (default) I=0 I=0 I3=0 I=0 O=OFF O=OFF outputs state input status A=00.0% U=66,7%.0V A:0 60 U:80 00 analogue level supply voltage analogue level (setpoints) in % supply voltage level (setpoints) in % Password Default password 35 If you forgot password, you can restore default password with jumper J 7