SGH Cable Actuated Sensor Industrial CANOpen

Similar documents
SGH. SGH inch stroke range, no terminating resistor 5-pin M12 mating plug, mounting bracket. CANopen Output Signal SGH-80-4-TR

SR1H Cable Actuated Sensor Industrial CANOpen Output Signal

SKH. CANOpen Output Signal. Linear Position to 400 inches (10 m) Compact Design Simple To Install User Adjustable Measuring Cable Orientation

SGJ Cable Actuated Sensor Industrial CANBus J1939

Dual Channel LVDT/RVDT Readout/Controller

PT8CN. CANbus SAE J1939 Output Signal

ED-22 Analog Output Series Magnetic Encoder

ULTIMATE-PRECISION DIGITAL LBB

CANopen IO X2 Fact sheet

D-SERIES INCLINOMETER

CANopen IO X4 Fact sheet

PT9DN. Heavy Industrial DeviceNET

PT9232. Heavy Industrial RS232 Communication

Analog output linear. Wear free, high resolution High shock resistance Servo flange mounting U8 I1

MEAS HTU21D PERIPHERAL MODULE

CANopen IO X1 Fact sheet

P-SERIES INCLINOMETER

T600 TACHOMETER MultiTasker - a measurement & monitoring instrument with 2 frequency and 1 analog inputs

3 CH Analog Output module / CANopen

T200 IDENT PRINTER BUDGET THERMAL TRANSFER PRINTER TECHNICAL DATASHEET

GW-7553-CPM PROFIBUS/CANopen GATEWAY. User's Manual

ABSOPOS Series CANopen DS406 V3.1 Operating Manual Configuration and CAN-Bus Coupling

VP Process Inc. Model: VP-EC-RDU Modbus RTU LCD Display

TSYS01-FAMILY Digital Temperature Sensors

Operating Manual. Inferface. CANopen. English

TE3124 PRINTER THERMAL TRANSFER PRINTER TECHNICAL DATASHEET

INDUSTRIAL MINI I/O CONNECTOR

MEAS TEMPERATURE SYSTEM SENSOR (TSYS01) XPLAINED PRO BOARD

CANopen Manual. Draw Wire Sensor Series SX Draw Wire Sensor Series MH Encoder Series WP

CANopen Unit CANit-20

PRINTER ACCESSORIES TECHNICAL DATASHEET UNIVERSAL REEL HOLDER

Draw wire sensors, draw wire sensors for displacement, position

VisConnect VC-2xxx Series Converter. Product Manual. VC-2xxx Series Converter Product Manual

REMOTE INPUT/ OUTPUT TERMINAL SYSTEM (RITS) CONNECTORS

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

NOVOtechnik SIEDLE GRUPPE

IO Module User Manual

Integrated Stepper Drive & Motor

PRINTER ACCESSORIES TECHNICAL DATASHEET UNIVERSAL REEL HOLDER

NOVOtechnik. Content. TIM CANopen Gebrauchsanleitung TIM CANopen user manual SIEDLE GRUPPE

CANopen. Network configuration. Operating instructions Software. Integration of Bürkert devices in CANopen networks

MEAS OPTIMUS PRESSURE SCANNING SYSTEMS

Positioning Controller

AEROSPACE, DEFENSE & MARINE /// MC801 FIBER OPTIC CONNECTORS

AMP-LATCH RIBBON CABLE INTERCONNECT SOLUTIONS

AP-COBD Manual V /03

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

USER MANUAL EAZY-CAL LVC-4000 LVDT Signal Conditioner

CANopen. stepim. Reference Manual. Manual Revision: 1.3 Firmware Version:

Draw wire sensors, draw wire sensors for displacement, position

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

CAN OPEN DP404 Digital Output

hipecs-cio55 CANopen I/O module with 4 analog inputs

Rotary Measurement Technology Absolute Encoders, Multiturn

hipecs-cio56 CANopen I/O module with PT100/1000 inputs

CANopen Interface for SG5 and SG7

Universal Safety Photo Eye UL MONITORED DEVICE

CANopen Interface for SG5, SG6 and SG7

EZ-LIGHT K50 Modbus Series Pick-to-Light Sensors

CMP Applications. Features

User Manual. K Series Encoders with CANopen Interface KXN FE 09 / 2005

FACTORY AUTOMATION. MANUAL R CANopen Protocol

MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL

Compact IO Modules (M8) for CANopen

More Precision. Draw-wire displacement sensors

CANopen User Manual IE25, IWN

CANopen User manual Website: Technical Support: Skype: Phone: QQ: Technical forum:

User Manual. R Series Encoders with CANopen Interface RNX HE 11 / 2005

hipecs-cio52 CANopen I/O module with 4 analog outputs

More Precision. Draw-wire displacement sensors

MS4515DO SPECIFICATIONS FEATURES APPLICATIONS

Actuator Commissioning Tool

VisConnect VC-20xx Series Converter. Product Manual. VC-20xx Series Converter Product Manual

ETHERNET INTELLIGENT PRESSURE SCANNER

High Voltage DC Meter

CMP Applications. Features

Connection Procedure of WAGO CANopen Bus Coupler and Pro-face AGP-3****-CA1M/LT. Instruction Manual. Version1.1 (

1 General Description

T3224 PRINTER. THERMAL TRANSFER PRINTER (600dpi) TECHNICAL DATASHEET

2-Way Wireless I/O Expander Installation Guide

EUROCARD CONNECTORS PER DIN AND IEC

3M Pak 100 Wiremount Plug Series

FLAT FLEXIBLE CABLE (FFC) CONNECTORS

Linear-Encoders CANopen Profile

M5600/U5600 Software Manual Wireless Pressure Transducers (Rev 2.0)

Installation & Operation Guide

MODULAR PLUGS, ACCESSORIES AND TOOLING

User manual. Inclinometer with CANopen-Interface IK360

PDW30 Point-To-Point Wireless Bridge

Linear measuring technology

For Powerful Digital Marketing and Total Multimedia Solution DV-6664 & DV-6664T. User s Guide version 1.0

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

AS5161-EK-AB / AS5162-EK-AB 12 BIT Magnetic Angle Position Sensor

I-8123W CANopen Master Module

MCx-xxxAx Installation. Contents. Mounting: Short Instruction MCx-xxxAx Connecting Power and Signal

Contents. Additional Instructions P-3X CANopen

AS5510. User Manual AS5510 Adapterboard. 10-bit Linear Incremental Position Sensor with Digital Angle output

Linear-Encoder Multi-Sensor CANopen Profile

Transcription:

Cable Actuated Sensor Industrial CANOpen Two Available Stroke Ranges: 0-80 in & 0-120 in. Rugged Polycarbonate Enclosure Simple Installation Compact Design Built for IP67 environments IN STOCK FOR QUICK DELIVERY! 5.0 [127 mm] 6.3 [160 mm] 80-inch 120-inch 3.8 [96 mm] 5.2 [131 mm] Ordering Information: w/o terminating resistor w/ terminating resistor CAN-H CAN-L 5-pin M12 connector 16 ft (5 m) 22 AWG (.50mm²) 5-pin, field installable M12 connector 120 Ω -80-4 80-inch stroke range, no terminating resistor, 5-pin M12 mating plug, mounting bracket included -80-4-TR 80-inch stroke range, with terminating resistor, 5-pin M12 mating plug, mounting bracket. 2.6 [66 mm] A perfect solution for both OEM and single-piece user, this string pot provides an economically priced CANopen sensor for 80-inch and 120- inch stroke range applications. This sensor is constructed with a rugged polycarbonate enclosure, a stainless steel mounting bracket and universally accepted M12 connector for operation in both outdoor or factory dry environments. For the OEM, customized options are available. -120-4 120-inch stroke range, no terminating resistor, 5-pin M12 mating plug, mounting bracket included -120-4-TR 80-inch stroke range, with terminating resistor, 5-pin M12 mating plug, mounting bracket. Optional Cordset for short-run connections, a convenient optional 16-ft. cordset with a 5-pin M12 connector. 9036810-0030 Field Installable Connector While every SGJ ships with a field installable 5-pin M12 mating plug, additional connectors are available. 9036810-0032 Specifications Stroke Range Options 80 in. (2032 mm), 120 in. (3048 mm) Accuracy.5% FS. Repeatability.05% FS. Resolution 12-bit Input Voltage 10-36 VDC Input Current 100 ma, max. Measuring Cable.019-inch dia. nylon-coated stainless steel Measuring Cable Tension, 80-inch 14 oz. (3,9 N) ±30% Measuring Cable Tension, 120-inch 9 oz. (2,5 N) ±30% Maximum Acceleration 10 g Sensor plastic-hybrid precision potentiometer Cycle Life 250,000 Electrical Connection M12 connector (mating plug included) Enclosure glass-filled polycarbonate Environmental IP 67 Operating Temperature -40 to 185 F (-40 to 85 C) Weight, 80-inch (not including bracket).6 lbs (272 g) Weight, 120-inch (not including bracket) 1 lb. (454 g) CANopen Specifications Communication Profile CiA 301 V 4.0.2, CANopen Slave Device Type CiA 406 V3.2, Encoder Vendor ID Company x0002e0, Dept x00 Node ID 1-127 (Adjustable via dipswitch or LSS, default set to 1) Baud Rate Options 125K (default), 250K, 500K, 1M Data Rate 50ms (default) Error Control Heartbeat, Emergency Message PDO 2 TxPDO, 0 RxPDO, no linking, static mapping PDO Modes Event / Time triggered, Synch / Asynch SDO 1 server, 0 client Position Data Object Dictionary 6004 Cam Switches Not Supported Termination Resistor See Ordering Information SENSOR SOLUTIONS /// PAGE 1

Electrical Connection: connector cordset field installable connector (included) 1 signal pin pin-colorcode n/c 1 1 - brown 10...36 Vdc 2 2 - white common 3 3 - blue CAN high 4 4 - black CAN low 5 5 - green/yellow 4 5 4 contact view 2 3 1 2 2.4 [60mm] cordset, part no. 9036810-0030 (optional) customer supplied electrical cable, (.25 in [6 mm] max. dia.) 5 contact view 3 1.7 [45 mm] (.21 in [5 mm] max. dia.) 22 AWG (.50mm 2 ) 16.4 ft. [5 M] Position Data Overview: 0x000 (out of range) 0x006 0xFE5 0xFFF (0% fs.) (100% fs.) (out of range) Nominal Full Stroke Range Position Values position data... endpoint tolerance 0x002 0x00A 0xFCC 0xFFC endpoint tolerance cable extension Internal Controller Board spring loaded cable reel access to controller board and dipswitch Status LED - Indicates Operating Condition of the Potentiometer green red on flash emergency message (high) off flash buffer (high) on off normal operating range flash off buffer (low) flash on emergency message (low) LSS, Baud Rate and Node ID settings: LSS, Baud Rate and Node ID settings are set via dip switch found on the internal controller board. To gain access to the controller board, remove the 4 cover attaching screws and carefully separate the sensor cover from the main body. Be careful not to damage the small gage wires that connect the potentiometer to the controller board mounted directly to the rear cover. Follow the instructions below for desired settings and reinstall sensor cover. SENSOR SOLUTIONS /// PAGE 2

Settings (cont.): LSS options on off 1 2 3 4 5 6 7 8 9 10 LSS settings SW1 disabled off enabled on LSS Settings: IF DIP Switch 1 is set to on position, then LSS will be functional and uses the contents of EEPROM including Node ID and Baud Rate. If DIP Switch 1 is set to off position, then DIP switches will override information in EEPROM including the Node ID and Baud Rate. on off 1 2 3 4 5 6 7 8 9 10 BAUD Rate: If DIP Switch 1 is set to off then BAUD rate is set via DIP switch 2 and 3 as shown : transmission rate options baud rate SW2 SW3 125 kbps off off 250 kbps on off 500 kbps off on 1 Mbps on on node ID options 1 127 (0x01 0x7F) off 1 2 3 4 5 6 7 8 9 10 node ID SW4 SW5 SW6 SW7 SW8 SW9 SW10 Dec. Hex (20) (2¹) (2²) (2³) (24) (25) (26) 1 0x01 on off off off off off off 2 0x02 off on off off off off off 3 0x03 on on off off off off off........................... 126 0x7E off on on on on on on 127 0x7F on on on on on on on on Node ID: If DIP Switch 1 is set to off then the Node ID is set via DIP switches 4 10 as shown below. The DIP switch settings are binary starting with switch number 4 (=2 0 ) and ending with switch number 10 (=2 6 ). The Node ID is equal to the binary setting. Manufacturer Objects: Index Sub-Index Name Default Comment 2000 Raw Position Value This is the averaged, non-scaled value from the encoder. 2001 Emergency Buffer Distance 0.1 Emergency Message is sent when the output of the sensing potentiometer is outside it s calibrated range by more than.1% of the sensors full measurement range (Emwergency Buffer). This allows for non-repeatability of sensor and customers application. This object allows user ability to change buffer size along with transmission of Emergency Message, Manufacturer specific bit in error register set, and error added to error list. Device Profile Area: Index Sub-Index Name Default Comment 6000 Operating Parameters 0X0000 6004 Position Value 0 Counts proportional to measuring cable extension. Nominal values are 0x006 with cable fully retracted and 0xFE5 with cable fully extended. Format of data in CAN message is little endian least significant byte pair first. Therefore 0x008 would be shown as 08 00 and 0xFE5 would be shown as E5 0F 6400 Area State Register SubNumber= 2 (indicates underflow or overflow per CiA406) 0 Highest Subindex 0x01 1 Work Area State Channel 1 0 SENSOR SOLUTIONS /// PAGE 3

Device Profile Area (cont.): 6401 Work Area Low Limit The averaged, non-scaled (raw) encoder data below which the encoder is out of range. 0 Highest Subindex 0x01 1 Work Area Low Limit Channel1 0x024 6402 Work Area High Limit The averaged, non-scaled (raw) encoder data above which the encoder is out of range. 0 Highest Subindex 0x01 1 Work Area High Limit Channel 1 0xF4E 6500 Operating Status 0x0000 6501 Measuring Step 1 Position Measuring Step. Can be set by user to convert Position Value (Object 6004) to measurement units (inches, mm). Default is set to 1. Communication Area Profile: Index Sub-Index Name Default Comment 1000 Device Type 0X00080196 Device Profile 406 1001 Error Register 0 Manufacturer Specific Error bit 7 is set when sensor is outside of calibrated range and cleared when back in range. 1003 Pre-Defined Error Field SubNumber= 9 (lists last eight Emergency Messages) 0 Number of Errors 0 1 Standard Error Field 1 2 Standard Error Field 2 3 Standard Error Field 3 4 Standard Error Field 4 5 Standard Error Field 5 6 Standard Error Field 6 7 Standard Error Field 7 8 Standard Error Field 8 1005 SYNC COB-ID 0x80 1010 Store Parameters SubNumber=2 1010 0 Highest Subindex 0x01 Only Save All Parameters feature supported 1 Save All Parameters Write save or evsa to save parameters to EEPROM. They are automatically loaded on power up/reset. Saves the value of all R/W object dictionary entries. 1014 Emergency COB-ID $NodeID + 0x80 COB-ID Emergency Message 1015 Emergency Inhibit Time 0 Multiple of 100us. Minimum time between transmissions of emergency messages. 1017 Producer Heartbeat Time 0 Multiples of 1ms. Time between transmission of heartbeat messages. 0 = disabled SENSOR SOLUTIONS /// PAGE 4

Communication Area Profile (cont.): 1018 Identity Object 0 Number of Entries 4 1 Vendor Id 0x2E0 2 Product Code 269 (decimal) Celesco Reference # 604269 3 Revision Number 1 4 Serial Number 0x00000000 1800 Tx PDO Comm. Parameter PDO1 0 Number of Entries 5 1 COB-ID $NodeID + 0x108 COB-ID used by PDO1 2 Transmission Type 254 PDO1 Tx Type: 0 = on Sync Message. 254 = Asynchronous Tx 3 Inhibit Time 0 Multiple of 100us. Minimum time between transmissions of the PDO 5 Event Timer 0x32 If non-zero then transmits the PDO periodically. This value is a multiple of 1ms. 1801 Tx PDO Comm. Parameter PDO2 0 Number of Entries 5 1 COB-ID $NodeID + 0x280 COB-ID used by PDO2 2 Transmission Type 0 PDO2 Tx Type: 0 = on Sync Message. 254 = Asynchronous Tx 3 Inhibit Time 0 Multiple of 100us. Minimum time between transmissions of the PDO 5 Event Timer 0 If non-zero then transmits the PDO periodically. This value is a multiple of 1ms. 1A00 Tx PDO Mapping Parameter Subnumber = 2 0 Number of Entries 1 1 PDO Mapping Entry 0x60040020 Mapping Parameter 1A01 Tx PDO Mapping Parameter Subnumber = 2 0 Number of Entries 1 1 PDO Mapping Entry 0x60040020 Mapping Parameter SENSOR SOLUTIONS /// PAGE 5

80-inch -80-4 w/ Mounting Bracket: 1.87 [47,5] eyelet detail.56 [14,3] Ø.22 [5,6] 2 plc. Ø.79 [20,1] Ø.40 [10,2].20 [5,1].65 [16,5].69 [17,5] 3.38 [85,7] 4.98 ±.13 [126,5 ±3,3] 1.65 [41,9] 1.50 [38,1] Ø.18 [4,5] 4 plc. 3.15 [80] Ø2.00 [50.8] 3.25 [82,6] 1.13 [28,6] 3.80 [96,4].9 [22,9] 2.62 [66,5] INCHES [MM] 120-inch -120-4 w/ Mounting Bracket: 1.87 [47,5] eyelet detail.56 [14,3] Ø.22 [5,6] 2 plc. Ø.79 [20,1] Ø.40 [10,2].20 [5,1].65 [16,5].69 [17,5] 4.75 [120,1] 6.32 ±.13 [160,5 ±3,3] 2.20 [55,9] Ø.18 [4,5] 4 plc. 4.49 [114] Ø2.00 [50.8] 2.30 [58,4] 4.62 [117,4] 1.20 [30,5] 1.13 [28,6] 5.17 [131,3] 2.62 [66,5] INCHES [MM] SENSOR SOLUTIONS /// PAGE 6

Mounting Options: Changing Measuring Cable Exit and Electrical Connector Direction: For the ultimate in flexibility, the measuring cable exit direction and the di- mounting bracket and attaching screws. rection of the electrical connector can be rotated around in 90 increments to accommodate just about any installation requirement. sensor cover and mounting screws. To change measuring cable exit direction, simply remove the 4 mounting bracket screws, rotate the bracket to desired position and replace the screws. To change the direction of the electrical connector, remove the 4 sensor cover screws and carefully remove the sensor cover just far enough to separate the cover from the main body. Be careful of the three small gage wires that attach the internal controller board to the potentiometer. Mounting Option Mounting Dimensions 80-inch (-80-4): 4.98 [126,5] 1.71 [43,4].53 [13,5] 2.77 [70,4] 1.71 [43,4] 1.68 [42,7] INCHES [MM] Mounting Option Mounting Option Dimensions 120-inch (-120-4): 1.71 [43,4] 6.32 [160,5] 4.11 [104,4].49 [12,4] 1.71 [43,4] 1.72 [43,7] SENSOR SOLUTIONS /// PAGE 7

NORTH AMERICA Measurement Specialties, Inc. a TE Connectivity Company 20630 Plummer Street Chatsworth, CA 91311 Tel +1-800-423-5483 Tel +1-818-701-2750 Fax +1-800-701-2799 customercare.chtw@te.com te.com/sensorsolutions Measurement Specialties Inc. a TE Connectivity company Measurement Specialties, TE Connectivity, TE Connectivity (logo) and Every Connection Counts are trademarks. All other logos, products and/ or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2016 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS /// version 3.0 // October 12, 2016 PAGE 8