Seletek. Tarsier. User's manual

Similar documents
Pegasus Astro Dual Motor Focus Controller v2.0

Pegasus Astro Stepper Motor Focus Controller v1.x

Pegasus Astro Dual Motor Focus Controller v3.0. Thank you for choosing our Dual Motor Focus Controller v3.0 (DMFCv3)

Installing the Focus Motor

Installing the Focus Motor

IRF90 - Rotating Focuser

Artemis Focuser User Guide. S Chambers

MD3. Microstepping Motor Driver Page 1 of 7. Description. Software. Mechanical Drawing. Features

VERSION 1.1 SEPTEMBER 12, 2017 ULTIMATE POWERBOX PRODUCT MANUAL BY PEGASUS ASTRO [COMPANY ADDRESS]

TOC F1 Operations Manual

TCF-Lynx 2-inch Focuser Installation

PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLATION!

ConText "Control by Text"

DIGITAL PANEL THERMOMETER

TCF-S Commander Help

Dimensions (inch) 3.74 x 1.45 x.95. PMA1-03S 70 MHz - 3 GHz Inline Power Monitor with SMA Connectors 1

TRIO-TECH SOFTWARE CONTENTS

USER MANUAL. IST channel speed calibrator

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

Dimensions (inch) 3.74 x 1.45 x.95. PMA1-08S 70 MHz -10 GHz Inline Power Monitor with SMA Connectors 1

Skyan. Wireless Control System for Telescopes. Copyright 2007 Belsico Inc. Rev. 1.3

Datalogging Hot Wire CFM Anemometer

CODUCTIVITY METER OPERATION MANUAL. Model : CD-4303

DEV16T. LCD Daughter board

PC Focus Control Operator's Guide

ST400C-NT USER S GUIDE. Table of Contents

Heavy Duty Hot Wire CFM Thermo-Anemometer

3 in 1, Type K/J, Pt 100 ohm, Infrared Thermometer Real time data logger, Data logger no., RS232 THERMOMETER.

ProScale LCD Readout Quick Start Guide

SS443 Unipolar Hall-Effect Digital Switch

CBM-105FP Troubleshooting

Model IMP-22G2,H Low Cost Slave Clock Impulser Converts your slave clock to a working timepiece without modifying its original mechanism.

CCD Astronomy. Imaging the Deep Sky. Ken Westall. Abell 1656 Coma Galaxy Cluster

Paramount Robotic Telescope Mount Specifications

GUIDE PROGRAMMABLE PANEL METER M905

HEAVY DUTY WATERPOOF MONITOR

RCX Tutorial. Commands Sensor Watchers Stack Controllers My Commands

micro Bus-Cam 2K for BC2000 Enclosures

Alt-Az 'GoTo' Telescope drive and tracking system

ASTRO-PHYSICS GTO CONTROL BOX FOR SERVO DRIVE Model GTOCP1

705 INSTALLATION MANUAL

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Programmable Control. Name Class Teacher. Ellon Academy Technical Faculty

TOC DX1-K Operations Manual

1. Introduction 2. Specifications 3. Symbol Definition and Button Location 4. Operation Instructions 5. Temperature Measurement 6.

INJECTION EXPLORER STARDEX 0501

DIGITAL PANEL THERMOMETER

MicroTrans EQ Signal Processor. Operation & Maintenance Manual

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Datalogging Conductivity/ TDS Meter. Instruction Manual

Baader SteelDrive Instruction Manual

SS3144 Unipolar Hall-Effect Digital Switch

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

Motorized Capacitor. Electrical Installation of ID-400. Service Bulletin 63

INTRODUCTION. FX-1 Operations Manual. Standard Features. Optional Features. Read This Manual Completely Before Proceeding!

TR-TEXT_EC. Display module for use with the EMUS BMS from Elektromotus and motor controllers from Curtis Instruments

Color Touchscreen Users Manual

Temperature-Humidity Sensor Configuration Tool Rev. A 1/25/

ASEQ MC35. USB stepper motor controller, driver

1. Introduction 1.1.Product Overview

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

QCPort Cover Control Trouble Shooting Guide

CDD4 Duct Carbon Dioxide Transmitter

Computer Interface for Focusmate Driver/Digital Indicator. Operating Guide

Smart Focus. Operator's Guide. Copyright 2013 JMI Telescopes Jim's Mobile, Inc W 14th Ave Lakewood, CO U.S.A.

FILM & VIDEO SETUP MANUAL

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

ECI1. COMPASS display. ECI1-REV For latest update: Electronic Compass Indicator ECS1

195Z. 321Z_Manual_V0.82

mi:node User Manual Element14 element14.com/minode 1 User Manual V3.1

What s in the Box? REAR VIEW SAFETY

GF-1. Introduction. 1 Features. +-10G Tilt Compensated dual range aviation G-force meter. Operating Manual English 1.00

User Manual. Rack Mount Display Monitor - 4K RMP-161-4K17. 7U 17.3 inch Rack Mount Display Monitor

How to Electrical Calibration

Studuino Programming Environment Manual

OVEN INDUSTRIES, INC.

Studuino Programming Environment Manual

Waves. MultiRack SoundGrid V9. Outboard Processing Host for Your DiGiCo Console


Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

242 Winch 1 User Manual

Blue Point Engineering

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

Create moving images in forward and reverse with your Arduino when you connect a motor to an H-bridge and some still images BATTERY POTENTIOMETER

Engine Test Bench Manual ADH-1 (version 1.0)

Jadis I-35. Owner's Manual. Integrated amplifier

Shack Clock kit PCB Revision: QCU Rev 1 or QCU Rev 3

EV3 Programming Workshop for FLL Coaches

Manual Anemometer PCE-423

ICS Regent. Thermocouple Input Assembly. Input Module, Mux, Termination Panel and Cable (T3431-IM, T3431-Mux, T3431-TP and T3431-CA) PD-6024

RMCWin. WalkThrough. This document is intended for walking through RMCWin with customers over the telephone/internet.

CALOG CALOG - LC DISPLAY. Loadcell Display. English Users Manual. Rev. 1.10

SS1438 Unipolar Hall Switch

User Manual. Rack Mount Display Monitor RMP-161-F17A. 6U 17.3 inch Rack Mount Display Monitor. Options : - AV, S-video input - Touchscreen

Display Unit User Manual

DINALOG A 144 x 36 A1400 Light-Strip Indicator

OPERATION MANUAL. SD card real time datalogger, RS232/USB VIBRATION METER. Model : VB-8206SD

TEC APO 200 OWNER S MANUAL

Transcription:

Seletek Tarsier User's manual Tarsier users' manual rev. 1.1 1 21/11/2013

The Seletek Tarsier has been designed to assist in the task of focusing a telescope, in those situations where a computer is not desirable or available. While it will not perform auto-focusing functions, it will make the task of focusing much easier as: it will drive almost any kind of motor, from inexpensive DC ones to high accuracy stepper ones as you won't touch the focus knob, the scope will not vibrate thus making the process faster and more accurate focus positions can be permanently stored for a repeatable positioning of the imaging train it includes a display to make the process much easier and last, if a careful calibration is done, it will track the temperature as the session progresses and will automatically move the focuser to the correct position, avoiding the need to manually refocus every time. Setup For the device to operate, you will have to supply: a 12V DC power supply (standard power jack, positive inside) a suitable motor coupled to your telescope focuser: either a stepper one (any of the Seletek focuser motors and plates, apart from motors by Technical Innovations, Moonlite, FeatherTouch, Lakeside...) These motors will use the DB9 connector of the Tarsier or an inexpensive DC one (from Orion, Rigel systems or many others) These ones will connect to the mono audio jack of the Tarsier Optionally, an external temperature sensor (again, compatible with all other Seletek models) Tarsier users' manual rev. 1.1 2 21/11/2013

Operation of the Tarsier One powered, we'll be presented with the main screen: Tarsier P: 0 where we can see the actual position of the motor ( 0 ). If we have installed the optional temperature sensor, the current temp. in ºC will also be displayed T: +20º C P: 0 First, please note the buttons can be pressed in two ways, a normal one, button pressed and released in a few tenths of a second, and a long one, if the button is kept pressed for longer. So, going to business, the buttons will operate in the following way: Menu [normal press] access the MENU [long press] save the current position, see later in the manual > and < move to either direction, in a slow way, that meaning: [normal press] the motor will move a small number of steps (you can define that number from the MENU) [long press] it will move continuously at the slowest speed defined, until the button is released >> and << same as before, but faster: [normal press] the motor will move a higher number of steps (you can also define that number from the MENU) [long press] it will move continuously accelerating from the slowest speed defined to the fastest one OK [long press] the current position (and temperature if available) will be stored in the internal list Tarsier users' manual rev. 1.1 3 21/11/2013

So far, we can already operate our Tarsier; no configuration is needed in many cases, and our focusing experience has already improved compared to a fully manual operation. Take make the most of the Tarsier, however, it is recommended to keep reading. From the MENU, we will access quite a few options: Saved points Temperature compensation (SUBMENU) from current point from saved point parameters Motor configuration (SUBMENU) Minimum speed Maximum speed High accuracy (steps) Low accuracy (steps) Motor type Wiring Backlash Halfstep Power while moving Power while stopped Reset position Backlight Contrast Volume Pressing OK at any option will go down in the MENU, pressing MENU will go up until back to the main screen. Tarsier users' manual rev. 1.1 4 21/11/2013

Detailed description of options: Saved points Access to the list of saved positions; use the direction keys to navigate, OK to perform a goto to the displayed point, long press of OK to delete the point. The points with stored temperature reading will be used for the temperature compensation algorithm. Menu to go back Temperature compensation (SUBMENU) (more on temp. comp. Later) from current point the controller will understand the scope is already correctly focused, and will start applying corrections, based on the temperature drift, from this moment. Press Menu to leave the temperature compensation mode, no other buttons will have any effect while active. from saved point the controller will understand the scope is NOT correctly focused, and will first move to the position matching the current temperature, then apply corrections, based on the temperature drift, from this moment. This feature is the most powerful to users with a fixed imaging train as, if the focuser is not moved manually (disengaging the motor) at any time, the can be up and running in no time! Press Menu to leave the temperature compensation mode, no other buttons will have any effect while active. Parameters will simply display the parameters calculated for the current set of points, showing the slope and the offset. Tarsier users' manual rev. 1.1 5 21/11/2013

Motor configuration (SUBMENU) Minimum speed specify the minimum speed of the motor, in milliseconds / step. Maximum speed specify the maximum speed of the motor, in milliseconds / step. Note: as it is specified in ms / step, the value for min. speed should be higher than the value for max speed! High accuracy (steps) this number defines the number of steps that the focuser: will move when the buttons < or > are pressed normally will wait for the temperature correction algorithm before applying any actual movement So, basically, this number should be related to the length, in steps, of your CFZ (critical focus zone). I suggest to use ½ the CFZ. Low accuracy (steps) number of steps a normal press of the << and >> buttons will imply Motor type used to select unipolar stepper (default), bipolar, DC or even step/direction interface Wiring Lunático (default), Lunático reversed motion, RF/Moonlite, RF/Moonlite reversed. Backlash backlash of the setup in steps Halfstep true or false, to drive the motor in full (default) steps or halved ones Power while moving % of the input power to be applied to the motor while in motion (PWM) Power while stopped Tarsier users' manual rev. 1.1 6 21/11/2013

same as before, while the motor is stopped (defaults to 0, only change if very sure of what you're doing) Reset position sets current position as 0, then cleans the saved points list and also updates the power on position to 0. Backlight adjust the brightness of the screen Contrast adjust the contrast of the screen Volume adjust the volume of the key click Tarsier users' manual rev. 1.1 7 21/11/2013

A few final notes a) About focuser position when storing the telescope If you want your goto points, or your absolute 1 temperature tracking parameters (that is, when you select from saved point ) to work between sessions, then it is important that the Tarsier memorizes the current position before switching it off. This can be accomplished simply by pressing Menu, long press, before switching it off, until the message position saved is displayed. b) Saving the fully racked in position in the list It may be convenient to store this position as one (the first?) of the goto points in the controller. Doing so, it won't be needed to save the position everyday (just the first one) and packing to go back home will be faster. Beware, however, if you plan to use temperature compensation, and the temperature is stored with that position, this will void the algorithm, as it will believe that point to be a valid focus point for that temperature. A trick for this to work not fooling the temperature compensation: press the direction buttons until the focuser is fully racked in carefully unplug the motor, so the temperature sensor is also removed (in general, it is not recommended hot plugging, just be careful this time!) wait a few seconds until the temperature reading disappears from the main screen (it will be replaced by No temp ); please be patient until the No temp is fixed on the screen, it may take a while as the temperature readings are averaged now long-press Ok to save the point to the list. Also long-press Menu to store the position as the one it will start from on power up. You can now go to the Saved points menu option to check the current position was saved with no temperature attached. c) About temperature compensation in general The accuracy of this approach will depend on motor and focuser quality, and on the thermal 1 The other way of applying temperature compensation, focusing first, will always be available whatever the focuser position... as long as you don't change the focal length of the setup! Tarsier users' manual rev. 1.1 8 21/11/2013

behavior of the telescope. With a good stepper motor (not with a DC one!), and a decent focuser, if you are careful setting it up you'll be surprised of the results. In order to maximize the possibilities of success, you should remember that: - It is recommended to place the temperature sensor in contact with the OTA, covered in such a way that no wind affects the reading. - Usually the tubes shrink with the fall of temperature of the night. So it is better to do the first focusing outwards, pulling out the focuser, to do it match with small compensation motions, that will also be outwards. - A good backlash calibration will be of real help in case the motor has to change direction. - And of course, and foremost, a careful selection of points, as perfectly focused as possible, and good temperature readings. Last, for those curious, even if the temperature is displayed in approx. Celsius degrees, no decimal places, it is stored in the system in 1/37 degree increment, far more than enough for the purpose of focusing. Recommended values: MinSpeed MaxSpeed MotorType Wiring Halfstep Power moving Power Stopped Lunatico 10 8 unipolar Lunatico Optional 100 0 RoboFocus 5 5 unipolar rf/moonlite Optional 100 0 FeatherTouch 3 3 bipolar lunatico Optional 100 0 Typ. DC 50 50 DC lunatico No 100 0 Tarsier users' manual rev. 1.1 9 21/11/2013

Tarsier users' manual rev. 1.1 10 21/11/2013