APC Backs UPS We re waiting for your call or email. 800-222-1440 uptime@uptime4u.com Cost Effective UPS Back UPS Office ES Best Value for Home (350 and 500 VA) Back UPS CS Best Value for Office (350 and 500 VA) Back UPS LS High Performance Home (350, 500, and 700 VA) Back UPS Pro High Performance Office (280 1,400 VA)
For Home and Business Back-UPS Office 350 Back-UPS Office 500 PART NUMBER BF350U BF500U Capacity 350VA(225W) 500VA(325W) Nominal input Total # of UPS receptacles Maximum Dimensions (H x W x L) 120 Vac single-phase, 50/60 Hz +/- 3 Hz (auto sensing) Single line phone/fax/modem/dsl 3 battery + surge, 3 surge only. 2 transformer block-spaced outlets 2.7 x 17.0 x 7.0 in (6.9 x 43.2 x 17.8 cm) Net weight 8.20 lb (3.73 kg) 8.60 lb (3.91 kg) User-replaceable, sealed, maintenance-free lead acid (included) Typical recharge time 9 hours 12 hours Visual indicators Serial RJ45 Connector Agency Approvals On line, on battery, replace battery, building wiring fault Automatic self-test at reboot USB Connectivity, data saving, unattended shutdown for Windows XP, Windows Me, and Windows 2000 included. UL, UL-C, CSA $75,000 lifetime protection, including lightning (see policy for details) Watts Back-UPS Office 350 Back-UPS Office 500 Typical runtimes 12 17
For Home and Business Back-UPS CS 350 Back-UPS CS 500 Back-UPS 650 PART NUMBER BK350 BK500 BK650MC Capacity 350VA (210W) 500VA (300W) 650VA (400W) Nominal Input 120 Vac single-phase, 50 or 60 Hz ± 5% Stepped approximation to sine wave output at 115 Vac ± 8% (auto sensing) Single phone/fax/modem/dsl Total number of receptacles 3 battery + surge, 3 surge only. 2 transformer block-spaced outlets Maximum Dimensions (H x W x L) 6.5 x 3.6 x 11.2 6.6 x 4.7 x 14.2 (16.5 x 9.1 x 28.3 cm) (16.8 x 11.9 x 36.1 cm) Net weight 13.1 lbs (5.9 kg) 15.3 lbs (7.0 kg) 23.0 lbs (10.4 kg) User-replaceable, Hot swappable, sealed, maintenance-free lead acid Maintenance-free lead acid Typical recharge time 6-8 hours 5-10 hours Visible indicators On-line, on battery, UPS overload, replace battery On-line 14 Day automatic self-test Manual self-test, adjustable battery transfer points and alarm settings USB Connector Data saving and unattended shutdown for Windows XP, Windows Me, Windows 98 and Mac OS 9 (9.0.4 or higher) included. Configuration software for Windows 2000 also included. Serial Connector Free optional in-box offer Data saving and unattended (Data saving and unattended shutdown for Windows XP shutdown for Windows XP, Windows Me, Windows 98, Windows 95, Windows 2000 Windows Me, Windows 98, and Windows NT included.) Windows 95, Windows 2000 and Windows NT included. Agency Approvals UL 1778, C-UL, FCC Part 68 FCC Part 68, UL 1778, CSA $100,000 lifetime protection, including lightning (see policy for details) Back-UPS CS 350 Back-UPS CS 500 Back-UPS 650 Typical runtimes 16 22 44
Product Specifications For Home / For Business Back-UPS LS 350 Back-UPS LS 500 Back-UPS LS 500 Clear Back-UPS LS 700 PART NUMBER BP350UC BP500UC BP500CLR BP700UC Capacity 350VA (220W) 500VA (315W) 700VA(410W) Nominal input 120 Vac single-phase, 50 or 60 Hz ± 5% Automatic Voltage Regulation (AVR) Total # of outlets Maximum Dimensions (H x W x L) Increases output voltage by 15% when input voltage is between 92 Vac and 106 Vac 2-line phone/fax/modem/dsl 4 battery back-up + surge, 3 surge only. 2 transformer block-spaced outlets 9.4 x 5.0 x 7.9 in (23.9 x 12.7 x 20.0 cm) Net weight 14.8 lb (6.7kg) 15.8 lb (7.2 kg) 17.0 lb (7.8 kg) Typical recharge time to 90% of full capacity Visual indicators USB Connector User-replaceable, hot swappable, sealed, maintenance-free lead acid (included) 6-8 hours On line, on battery, UPS overload, replace battery, building wiring fault 14 Day automatic self-test, manual self-test Data saving, unattended shutdown for Windows XP, Windows Me, Windows 98, and Mac OS 9 (9.0.4 or higher) included. Configuration software for Windows 2000 also included. Agency Approvals UL, C-UL, CSA UL, C-UL UL, C-UL, CSA $150,000 lifetime protection, including lightning (see policy for details) Back-UPS LS 350 Back-UPS LS 500 Back-UPS LS 500 Clear Back-UPS LS 700 Typical runtimes 17 20 20 28
For Business Back-UPS Pro 280 Back-UPS Pro 420 Back-UPS Pro 650 Back-UPS Pro 1000 Back-UPS Pro 1400 PART NUMBER BP280S BP420S BP650S BP1000 BP1400 Capacity 280VA (170W) 420VA (260W) 650VA (410W) 1000VA (670W) 1400VA (950W) Nominal Input Automatic Voltage Regulation (AVR) Vac single-phase, 50 or 60 Hz ± 5% (auto sensing) Factory Default: (on line) Increases output up to 30% when input between 81Vac and 106Vac. User-selectable transfer point as low as 75Vac. Decreases output up to 15% when input between 127Vac and 143Vac.User Selectable transfer point as high as 154Vac Single Line Phone/fax/modem/DSL/10-100 Base-T Total number of receptacles 2 battery + surge, 1 surge only 3 battery + surge, 3 surge only 3 battery + surge, 3 surge only 6 battery + surge 6 battery + surge Maximum Dimensions (H x W x L) 5.9 x 3.4 x 13.3 6.6 x 4.7 x 14.5 6.6 x 4.7 x 14.5 8.5 x 6.7 x 17.3 8.5 x 6.7 x 17.3 (15.0 x 8.6 x 33.8 cm) (16.8 x 11.9 x 36.8 cm) (16.8 x 11.9 x 36.8 cm) (21.6 x 17.0 x 43.9 cm) (21.6 x 17.0 x 43.9 cm) Net weight 16.6 lbs (7.9 kg) 21.6 lb (9.8 kg) 26.0 lb (11.8 kg) 42.6 lbs (19.3 kg) 54.1 lb (24.6 kg) User-replaceable, hot swappable, sealed, maintenance-free lead acid Typical recharge time 2-4 hours 3-6 hours Visible indicators UPS On-line, on battery, UPS overload, replace battery, site wiring fault 14 Day automatic self-test, manual self-test Serial DB9 RS-232 Connector PowerChute software with network manageability, data saving, unattended shutdown and UPS Optional network auto-shutdown software diagnostics for Windows XP, Windows Me, Windows 98, Windows 95, Windows 2000 and Windows NT Agency approvals CSA, FCC Part15 Class B, FCC Part 68, UL 1778 CSA, FCC B, UL1778 $150,000 lifetime protection, including lightning (see policy for details) Back-UPS Pro 280 Back-UPS Pro 420 Back-UPS Pro 650 Back-UPS Pro 1000 Back-UPS Pro 1400 Typical runtimes 14 20 45 79 145