Back-UPS RS APC Back-UPS RS 800VA 120V Black

Similar documents
Smart-UPS APC Smart-UPS 750VA USB & Serial 120V

Smart-UPS APC Smart-UPS 1500VA USB & Serial 120V

Smart-UPS APC Smart-UPS 2200VA USB & Serial 120V

Smart-UPS APC Smart-UPS 750VA USB & Serial RM 1U 120V

Smart-UPS XL APC Smart-UPS XL 2200VA RM 3U 120V

Smart-UPS APC Smart-UPS 2200VA RM 3U 120V/230V In 120V Out

Smart-UPS RT APC SMART-UPS RT 2000VA 120V

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 16kVA N+1, Tower 208/240V Input, 208/240V and 120V Output

Symmetra LX APC Symmetra LX 8kVA Scalable to 8kVA N+1 Rack-mount, 208/240V Input, 208/240V and 120V Output

APC Matrix-UPS 3kVA 208V/240V In 120/208/240V Out

Back-UPS RS 550 Installation & Operation

Installation and Operation Back-UPS Pro 900

Installation and Operation Back-UPS Pro 900

PC Smart-UPS XL Modular 1500VA 120V Rackmount/Tower

User Manual Back-UPS BE650MC

Installation and Operation Manual Back-UPS BR900G-RS

AIS 3000 APC AIS kVA 400V w/3 Batt. Modules Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Installation and Operation Back-UPS Pro BR700G-TW

User Manual Back-UPS Pro BN 1100/1350/1375/1400/1500 M2 BN 1100/1350/1500 M2-CA

APC Smart-UPS C. Efficient, true sine-wave power protection for entry-level servers and network equipment. >

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Premium Online Series

UPS Series. features: uninterruptible power supply. what great systems are built on.

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

SmartPro 120V 750VA 500W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro LCD 120V 1300VA 720W Line- Interactive UPS, AVR, Tower, LCD, USB, 8 Outlets

SmartPro LCD 120V 1200VA 700W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartPro LCD 120V 50/60Hz 1500VA 900W Line- Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

SmartPro 120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 1kVA 650W Line Interactive Sine Wave UPS, Tower, USB, DB9 Serial

Powerware 3105 UPS User s manual

Powerware 3105 UPS User s manual

Hardwired Uninterruptible Power Supply

APC Backs UPS. We re waiting for your call or

SmartPro 1.5kVA 1000W Line Interactive Sine Wave UPS, 2U Rack/Tower, LCD, USB, RS232, EPO, 120V

SmartPro LCD 120V 1500VA 900W Line- Interactive UPS, AVR, 2U Rack/Tower, LCD, USB, DB9 Serial, 8 Outlets

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Reliable backup power and surge protection for your critical electronics. Uninterruptible Power Supply Back-UPS Pro Compact Towers

SmartPro LCD 120V 1500VA 900W Line-Interactive UPS, AVR, Tower, LCD, USB, 10 Outlets

SmartPro UPS System Intelligent line interactive medical-grade battery backup and network power management

SmartOnline 120V 3kVA 2.7kW On-Line Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Option, ENERGY STAR

TAA-Compliant SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial

SmartPro 120V 1.05kVA 705W Line-Interactive UPS, Tower, 120V, USB port

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 3U Rack/Tower, USB, DB9 Serial

VS Series 120V 600VA 300W Line-Interactive Desktop UPS, Tower, 6 Outlets

AVR Series 230V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port, French/Belgian Outlets

SmartPro 120V 1kVA 750W Medical-Grade Line- Interactive Tower UPS with 4 Outlets, Full Isolation, USB, Lithium Battery

POS Series 120V 50/60Hz 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

AVR Series 120V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port

OFFICE UPS MULTI-DEVICE PROTECTION UPS 500S/600S/750S

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

SmartPro LCD 120V 1000VA 500W Line- Interactive UPS, AVR, Tower, USB, TEL/DSL/Coax Protection, 8 Outlets

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial

AVR Series 120V 700VA 350W Ultra-Compact Line-Interactive UPS with USB port

OmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer

SmartPro 230V 1.5kVA 900W Line-Interactive UPS, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets

OmniSmart LCD 120V 50/60Hz 1500VA 810W Line-Interactive UPS, Tower, LCD display, USB port, Energy Star

SmartPro 120V 750VA 450W Line-Interactive UPS, AVR, Tower, USB, Surge-only Outlets

Omni LCD 650VA Tower Line-Interactive 120V UPS with LCD display and USB port

TAA-Compliant AVR Series 120V 750VA 450W Ultra-Compact Line-Interactive UPS with USB port

BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets

SmartPro 208V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U Rack/Tower, Network Card Options, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack, USB, DB9 Serial, LCD

OmniSmart LCD 120V 1500VA 810W Line-Interactive UPS, Tower, LCD display, USB port, Energy Star

SmartPro 230V 2.2kVA 1.6kW Line-Interactive UPS, Tower, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 1kVA 800W Line Interactive Sine Wave UPS, SNMPWEBCARD option, 1U Rackmount, USB, RS232, EPO, 120V

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 3U Rack, LCD display, USB, DB9 Serial

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Tower, Extended Run, SNMPWEBCARD Option, USB, DB9 Serial

U P S USER S MANUAL IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Uninterruptible Power System. Line Interactive (Network) UPS

850VA 480W Line-Interactive UPS with 6 C13 Outlets - AVR, 230V, C14 Inlet, LCD, USB, Tower

SmartPro 230V 1.5kVA 900W Line-Interactive UPS, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets

SmartPro 120V 700VA 450W Line-Interactive Sine Wave UPS, Tower, 120 or 230V input, Network Card Options, USB, DB9

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

OmniVS 230V 800VA 475W Line-Interactive UPS, USB port, C13 Outlets

AVR Series 230V 550VA 300W Ultra-Compact Line-Interactive UPS with USB port, C13 Outlets

OmniSmart 120V 1400VA 940W Line-Interactive UPS, Tower, USB port

SmartOnline 120V 2.2kVA 1.6kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Network Card Slot, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.6kW Line-Interactive UPS, Tower, Extended Run, Network Card Options, USB, DB9 Serial

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

APC Easy UPS 1 Ph Online Rack Mount Models

SmartPro 230V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 230V 5kVA 3.75kW Line-Interactive Sine Wave UPS, 3U, Extended Run, Network Card Options, USB, DB9

Model #: SMART3000RM2U

TAA-Compliant OmniVS 120V 1000VA 500W Line-Interactive UPS, Tower, USB port

SmartPro 120V 750VA 450W Line-Interactive UPS, AVR (Boost only), Tower, USB

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

BC Pro 120V 1400VA 940W Standby UPS, Tower, USB port, 6 Outlets

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U, Extended Run, Network Card Options, LCD, USB, DB9

TAA-Compliant POS Series 120V 500VA 300W Standby UPS, Tower, USB port, 6 Outlets, TEL/DSL Protection

OmniVS 230V 1000VA 500W Line-Interactive UPS, Tower, USB port, C13 Outlets

OmniSmart 120V 500VA 300W Line-Interactive UPS, Tower, USB port

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets

SmartPro LCD 120V 1300VA 720W Line-Interactive UPS, AVR, Tower, LCD Display, USB

Powerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)

OmniVS 120V 1500VA 940W Line-Interactive UPS, Tower, USB port

ECO Series 120V 850VA 425W Energy-Saving Standby UPS with USB, LCD Display and 12 Outlets

Transcription:

Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email privacy : system recovery and online backup software, USB cable, User Manual Standard Lead Time: Usually in Stock

Back-UPS RS Features & Benefits Protection Battery-protected and surge-only outlets Boost and Trim Automatic Voltage Regulation (AVR) Data line surge protection Safety-agency approved Power conditioning Convenience Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment Gives higher application availability by correcting low and high voltage conditions without using the battery. Provides protection of connected equipment from power surges on the data lines. Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. Protects connected loads from surges, spikes, lightning, and other power disturbances. Audible Alarms Provides notification of changing utility power and UPS conditions. Automatic restart of Automatically starts up the connected equipment upon the return of utility loads after UPS power. shutdown Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Battery replacement Allows quick, easy battery replacement. without tools LED status indicators Quickly understand unit and power status with visual indicators. Cold-start capable Provides temporary battery power when the utility power is out. Hot-swappable Ensures clean, uninterrupted power to protected equipment while batteries batteries are being replaced Resettable circuit Enables a quick recovery from overload events. breakers Transformer-block Protect equipment with input transformer blocks without blocking access to spaced outlets other receptacles. User-replaceable Increases availability by allowing a trained user to perform upgrades and batteries replacements of the batteries reducing Mean Time to Repair (MTTR) Manageability Adjustable voltage sensitivity Adjustable voltagetransfer points Serial Connectivity USB Connectivity Multiple mounting methods Intelligent Battery Management Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. Provides management of the UPS via a serial port. Provides management of the UPS via a USB port (not available on all models). Allows for standardization on one product for use in different environments. Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.

Output Output Power Capacity Max Configurable Power Nominal Output Voltage Output Connections 540 Watts / 800 VA 540 Watts / 800 VA 120V (3) NEMA 5-15R (Surge Protection) (4) NEMA 5-15R (Battery Backup) Input Nominal Input Voltage Input Frequency 120V 47-63 Hz Input Connections NEMA 5-15P Cord Length Input voltage range for main operations Input voltage adjustable range for mains operation 1.83 meters 88-139V 78-152V Batteries & Runtime Battery Type Included Battery Modules 1 Typical recharge time Replacement Battery Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof 8 hour(s) RBC32 RBC Quantity 1 Typical Backup Time 17.3 minutes (270 Watts) at Half Load Typical Backup Time 5.1 minutes (540 Watts) at Full Load Runtime Chart Back-UPS RS Energy Use/Efficiency

Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and resistive load output. View Enlarged Chart Communications & Management Control panel Audible Alarm LED status display with On Line : On Battery : Replace Battery and Overload indicators Alarm when on battery : distinctive low battery alarm : configurable delays Surge Protection and Filtering Surge energy rating Filtering Data Line Protection 320 Joules Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449 RJ-11 Modem/Fax/DSL protection (two wire single line),rj45 10/100 Base-T Ethernet protection Physical Maximum Height 229.00 mm Maximum Width 102.00 mm Maximum Depth 324.00 mm Net Weight 9.32 KG Shipping Weight 10.24 KG Shipping Height 305.00 mm Shipping Width 229.00 mm Shipping Depth 432.00 mm Master Carton Units 1.00 Color Black

Units per Pallet 40.00 Environmental Operating Environment 0-40 C Operating Relative Humidity 0% Operating Elevation 0-3000 meters Storage Temperature -5-45 C Storage Relative Humidity 0% Storage Elevation Audible noise at 1 meter from surface of unit Online Thermal Dissipation 0-15000 meters 45.00 dba 170.00 BTU/hr Conformance Regulatory Approvals Standard Warranty CSA,FCC Part 15 Class B,FCC Part 68,UL 1449,UL 1778,UL Listed 3 years repair or replace **The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS.

TROUBLESHOOTING Problem Possible Cause Corrective Action Back-UPS will not switch on. Back-UPS not connected to AC power source. Ensure the Back-UPS is securely connected to an AC outlet. Back-UPS circuit breaker tripped. Disconnect non-essential equipment from the Back-UPS. Reset (push in) the rear panel circuit breaker. Switch on the Back-UPS and plug in devices one at a time. If the circuit breaker trips again, disconnect the device that caused the breaker to trip. Back-UPS does not power essential equipment during an outage. Back-UPS operates on battery although utility power exists. Back-UPS does not provide expected backup time. Red Replace Battery indicator is flashing. Green On Line indicator is on. Red Replace Battery indicator is on. Red Overload indicator is on or flashing. Green On Line indicator is on and all other front panel indicators are flashing. Utility input voltage quality is out of range. Internal battery cartridge is not connected. Equipment plugged into a Surge Only outlet. Back-UPS circuit breaker tripped. Utility input voltage quality is out of range. Back-UPS is heavily loaded. Back-UPS battery cartridge is discharged due to recent power outage and has not had time to recharge. Battery has reached the end of its life. Internal battery cartridge is not connected. Battery has reached the end of its life. Connected equipment is drawing more power than the Back-UPS can provide. Internal UPS fault. ORDER REPLACEMENT BATTERY CARTRIDGE Consider adjusting the transfer voltage and sensitivity. See Transfer Voltage and Sensitivity Adjustment. Connect battery cartridge (see Connect Battery Cartridge). Unplug device from 'Surge Only' outlet and move to a 'Battery Backup' outlet. Disconnect non-essential equipment from the Back-UPS. Reset (push in) the rear panel circuit breaker. Switch the Back-UPS on and plug equipment in one-at-a-time. If the circuit breaker trips again, disconnect the device that caused the breaker to trip. Consider adjusting the transfer voltage and sensitivity. See Transfer Voltage and Sensitivity Adjustment. Unplug non-essential equipment (printers, scanners, etc) from the Battery Backup outlets and plug into 'Surge Only' outlets. Charge the battery cartridge for 8 hours. Back-UPS runtime is reduced until the battery cartridge is fully charged. Replace battery cartridge (see Order Replacement Battery Cartridge). Connect battery cartridge (see Connect Battery Cartridge). Replace the battery cartridge (see Order Replacement Battery Cartridge). Move one or more equipment power plugs from Battery Backup outlets to Surge Only outlets. Contact APC Technical Support (see Contact Information). The battery cartridge typically lasts 3-6 years, shorter if subjected to frequent outages or elevated temperatures. Order part number RBC32. Please recycle spent battery cartridges. REPLACE BATTERY CARTRIDGE 1 2 3 4 SPECIFICATIONS Item On-line Input Voltage Range (default settings) Specification 88-139 Vac Automatic Voltage Regulation (AVR) +12% On-line Frequency Range 47-63 Hz (autosensing) On-battery Waveshape Stepped Sine Wave Maximum Load 800 VA - 540 W Typical Recharge Time 8 Hours Operating Temperature 32 o to 104 o F (0 o to 40 o C) Storage Temperature 23 o to 113 o F (-5 o to 45 o C) Operating / Storage Relative Humidity 0 to 95% non-condensing Size (H x W x D) 9 x 4 x 12.75 inch (22.86 x 10.16 x 32.38 cm) Weight 22 lbs (9.9 kg) Shipping Weight 23 lbs (10.4 kg) EMI Classification FCC / DOC Class B Certified On Battery Run-Time See http://www.apc.com/product TRANSFER VOLTAGE AND SENSITIVITY ADJUSTMENT In situations where the Back-UPS or connected equipment appears too sensitive to input voltage, it may be necessary to adjust the transfer voltage. This is a simple task requiring use of the front panel pushbutton. To adjust the transfer voltage, proceed as follows: 1. Plug the Back-UPS into the utility power source. The Back-UPS will be in a Standby Mode (no indicators lit). 2. Press the front panel pushbutton fully inward for 10 seconds. All indicators on the Back-UPS will flash to acknowledge going into Programming Mode. 3. The Back-UPS will then indicate its current Sensitivity Setting, as shown in the following table. Indicators Flashing 1 (yellow) 2 (yellow, and red) 3 (yellow, red, and red) Sensitivity Setting Input Voltage Range (for utility operation) Use When Low 78-142 Vac Input voltage is extremely low or high. Not recommended for computer loads. Medium (factory default) 88-139 Vac Back-UPS frequently goes On Battery. High 88-136 Vac Connected equipment is sensitive to voltage fluctuations (recommended). 4. To select the Low Sensitivity setting, press the pushbutton until the yellow indicator is flashing. 5. To select the Medium Sensitivity setting, press the pushbutton until the yellow and red indicators (second and third from the top) are flashing. 6. To select the High Sensitivity setting, press the pushbutton until yellow and both red indicators (bottom three) are flashing. 7. To exit without changing the Sensitivity Setting, press the pushbutton until the green indicator is flashing. 8. Once in Programming Mode, if the pushbutton is not pressed within 5 seconds, the Back-UPS will exit Programming Mode; all indicators will extinguish. SERVICE If the Back-UPS arrived damaged, notify the carrier. If the Back-UPS requires service, do not return it to the dealer. The following steps should be taken: 1. Consult the Troubleshooting section to eliminate common problems. 2. If the problem persists, go to http://www.apc.com/support/. 3. If the problem still persists, contact APC Technical Support. 4. Have the Back-UPS model number, serial number and date of purchase available. Be prepared to troubleshoot the problem with an APC Technical Support representative. If this is not successful, APC will issue a Return Merchandise Authorization (RMA) number and a shipping address. LIMITED WARRANTY The standard warranty is two (2) years from the date of purchase. APC s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the replacement unit to the customer. This device complies with Parts 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation.