PrepKing. PrepKing

Similar documents
Cisco UCS C200 M2 High-Density Rack-Mount Server

Cisco UCS C210 M1 General-Purpose Rack-Mount Server

Cisco UCS C210 M2 General-Purpose Rack-Mount Server

Cisco UCS C24 M3 Server

Cisco UCS C240 M3 Server

Cisco UCS C240 M3 Server

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

Cisco UCS C250 M2 Extended-Memory Rack-Mount Server

Cisco HyperFlex HX220c M4 Node

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Overview. Cisco UCS Manager User Documentation

Overview. About the Cisco UCS S3260 System

Cisco UCS B200 M3 Blade Server

Cisco HyperFlex HX220c Edge M5

Overview. About the Cisco UCS S3260 System

Cisco UCS B440 M1High-Performance Blade Server

Cisco UCS B230 M2 Blade Server

Cisco Connected Safety and Security UCS C220

Cisco Unified Computing System Delivering on Cisco's Unified Computing Vision

HP BladeSystem c-class Server Blades OpenVMS Blades Management. John Shortt Barry Kierstein Leo Demers OpenVMS Engineering

Cisco UCS B460 M4 Blade Server

C-Series Servers Meat and Tators

Cisco UCS E-Series Servers

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

Achieve Optimal Network Throughput on the Cisco UCS S3260 Storage Server

Design a Remote-Office or Branch-Office Data Center with Cisco UCS Mini

SAP High-Performance Analytic Appliance on the Cisco Unified Computing System


Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

UCS M-Series + Citrix XenApp Optimizing high density XenApp deployment at Scale

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

Cisco UCS S3260 System Storage Management

Questions & Answers

Sugon TC6600 blade server

UCS Technical Deep Dive: Getting to the Heart of the Matter

Installing the Server Operating System or Hypervisor

Cisco UCS Virtual Interface Card 1225

IBM Testpapers Now with Questions & Answers

Managing Cisco UCS C3260 Dense Storage Rack Server

Cisco Nexus 4000 Series Switches for IBM BladeCenter

Cisco UCS Mini. Edge-Scale Computing with Enterprise Capabilities. Rebecca Awde Cisco DC Specialist.

Cisco UCS S3260 System Storage Management

Cisco UCS S3260 System Storage Management

Front-loading drive bays 1 12 support 3.5-inch SAS/SATA drives. Optionally, front-loading drive bays 1 and 2 support 3.5-inch NVMe SSDs.

Cisco Services Ready Engine Virtualization Overview

SUN SERVER X2-8 SYSTEM

V.I.B.E. Virtual. Integrated. Blade. Environment. Harveenpal Singh. System-x PLM

Cisco StadiumVision Mobile Streamer

UCS-E160DP Double-wide E-Series Server, 6 core CPU, with PCIe

Density Optimized System Enabling Next-Gen Performance

HP Converged Network Switches and Adapters. HP StorageWorks 2408 Converged Network Switch

Installing the Operating System or Hypervisor

Oracle Database Consolidation on FlashStack

Next Generation Computing Architectures for Cloud Scale Applications

Data Center solutions for SMB

Lot # 10 - Servers. 1. Rack Server. Rack Server Server

HUAWEI Tecal X8000 High-Density Rack Server

Real4Test. Real IT Certification Exam Study materials/braindumps

Enterprise Network Compute System (ENCS)

Cisco 4000 Series Integrated Services Routers: Architecture for Branch-Office Agility

Cisco MCS 7845-H1 Unified CallManager Appliance

Cisco Exam Questions & Answers

Cisco Nexus 7000 Switches Supervisor Module

Cisco UCS Accelerated Accreditation Training

Cisco Actualtests Questions & Answers

Cisco Mobility Services Engine: An Open, Appliance-Based Platform for Delivering Mobility Services

Upgrading Earlier Release Version Servers for Cisco UCS Manager Integration

CompTIA ISS-001. Intel Server Specialist Certification. Download Full Version :

Rack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches

Cisco MCS 7825-I1 Unified CallManager Appliance

Active System Manager Release 8.2 Compatibility Matrix

Cisco UCS Unified Fabric

Cisco UCS E-Series Servers and Network Compute Engines

Deploying Cisco UCS Central

VersaStack for Data Center Design & Implementation (VDCDI) 1.0

Flexible General-Purpose Server Board in a Standard Form Factor

Veritas NetBackup on Cisco UCS S3260 Storage Server

GigaStor Upgradeable 2U. User Guide

Release Notes for Cisco UCS C-Series Software, Release 2.0(13)

Docker Enterprise Edition on Cisco UCS C220 M5 Servers for Container Management

HP0-S15. Planning and Designing ProLiant Solutions for the Enterprise. Download Full Version :

Cisco VDS Service Broker Software Installation Guide for UCS Platforms

Troubleshooting Server Disk Drive Detection and Monitoring

Backup Solution Testing on UCS B and C Series Servers for Small-Medium Range Customers (Disk to Tape) Acronis Backup Advanced Suite 11.

Overview. Overview. This chapter includes the following sections:

Overview. Overview. Cisco UCS 6324 Fabric Interconnect with Cisco UCS B-Series Servers and C-Series Servers, which is. Overview 1

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu.

Introducing the Cisco 1121 Secure Access Control System Hardware

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server


Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1

Cisco MCS 7835-H2 Unified Communications Manager Appliance

Overview of Cisco 3504 Wireless Controller

Cisco Troubleshooting Cisco Data Center Unified Computing. Download Full Version :

Acer Shared Resource Computing (SRC) Solution Brief

Cisco Secure Network Server

Cisco MCS 7845-I2 Unified Communications Manager Appliance

Transcription:

PrepKing Number: 650-286 Passing Score: 780 Time Limit: 120 min File Version: 8.5 http://www.gratisexam.com/ PrepKing 650-286

Exam A QUESTION 1 Which three interfaces are used to connect server management to the Cisco UCS C-Series server? (Choose three.) A. Connect via one of the server's standard-profile PCIe card slots on the rear panel of the server. B. Connect to the service processor using the integrated IPMI. C. Connect a console using the two USB ports on the rear panel of the server. D. Connecting a KVM cable to the server console connector on the front of the server. E. Connect using the 10/100/1000 Gigabit Ethernet RJ-45 ports on the front panel of the server. F. Use remote management through the 10/100 Ethernet management port on the rear panel of the server. DF /Reference: QUESTION 2 Before replacing a power supply on a Cisco UCS C-Series server, why is it vital to perform a graceful shutdown? A. to place the operating system into main power mode B. to avoid data loss or damage to the operating system C. to allow the operating system to be managed remotely D. to power down the operating system but allow the service processor and cooling fans to continue to operate Correct Answer: B /Reference: QUESTION 3 Which server is best suited for storage-intensive applications such as network file servers and appliances, storage servers, database servers, and content-delivery servers? A. Cisco UCS C210 M1 B. Cisco UCS C200 M1 C. Cisco UCS C260 M1 D. Cisco UCS C250 M1 /Reference: QUESTION 4 Using the show commands to view properties will provide information about which three of these items? (Choose three.)

A. voltage properties B. power supply properties C. storage properties D. CIMC log properties E. system log properties F. memory properties Correct Answer: BCF /Reference: QUESTION 5 What are two benefits of the Cisco extended memory technology? (Choose two.) A. It allows expansion of up to 384 GB of memory in a 2 RU form factor. B. It uses the virtual interface card to expand memory options up to 384 GB. C. It provides the cheapest memory expansion options in a 4 RU form factor. D. It can use 4-GB DIMMs for up to 192 GB for cost savings. E. It requires 8-GB DIMMs to expand memory to up to 384 GB. E /Reference: QUESTION 6 What is a feature of the Cisco extended memory technology? A. It offers the most flexibility for memory-intensive applications in a blade form factor. B. It increases performance and capacity for demanding virtualization and large-data-set workloads. C. It provides a flexible means of providing virtualization and policy compliance. D. It provides the performance needed for the Cisco unified fabric and 10 Gigabit Ethernet. Correct Answer: B /Reference: QUESTION 7 Which two areas of growth in the network have resulted in an increase in storage costs? (Choose two.)

http://www.gratisexam.com/ A. power and cooling B. speed and memory C. databases D. rich media E. system maintenance D /Reference: QUESTION 8 Which three architectural innovations are features of the Cisco UCS C-Series servers? (Choose three.) A. space-saving blade form factor B. virtual interface card for virtualization flexibility C. the latest Intel Itanium 9000 processor D. extended memory technology E. unified network fabric F. enhanced storage in a 4 RU form factor G. multiple points of management Correct Answer: BDE /Reference: QUESTION 9 In which two ways can you configure the RAID controller for the Cisco UCS C200 and C210 servers? (Choose two.) A. Access the RAID controller remotely using the Cisco UCS Manager GUI. B. Reinstall the firmware during a server reboot. C. Reset the power and reinstall the operating system to access the RAID controller built-in configuration GUI. D. Interact with the firmware installed on the controller during the server boot time using a BIOS configuration utility. E. Use Intel's RAID Controller Drivers after the operating system is installed. E

/Reference: QUESTION 10 How is WebBIOS used to set up RAID controllers? A. It enables users to create and manage RAID configurations on LSI SAS controllers. B. It allows administrators to adjust topology views from the controller and disk enclosure down to the logical and physical drive level to manage RAID volumes. C. It provides operating system-level software tools to efficiently manage all RAID controllers across the Cisco UCS C-Series server family. D. It provides integration with Intel RAID Controller Drivers once the operating system is installed. /Reference: QUESTION 11 Which server offers up to up to 384 GB of industry-standard DDR3 main memory in 48 DIMMs? A. Cisco UCS C260 M1 B. Cisco UCS C210 M1 C. Cisco UCS C200 M1 D. Cisco UCS C250 M1 /Reference: QUESTION 12 Which hardware feature of the Cisco UCS C-Series servers provides management services even in the event of a processor failure? A. the Cisco Integrated Management Controller B. the virtual interface card C. the Baseboard Management Controller D. the Intelligent Platform Management Interface /Reference: QUESTION 13 Which two situations have impacted virtualization in server technology? (Choose two.) A. increased number of virtualized servers to manage

B. need to consolidate the server infrastructure to a single location C. easy-to-secure policy coherence D. reduced number of physical servers needed E. need for increased points of management D /Reference: QUESTION 14 What are two reasons that a firmware upgrade might not be immediately activated on a server? (Choose two.) A. to provide a fail-safe in case the firmware upgrade is not installed correctly B. to allow the server to run normally during an upgrade C. to allow a specified amount of time before reboot using thecli reboot activate command D. to allow the operating system to be reinstalled E. to allow activation to take place when a reboot is selected B /Reference: QUESTION 15 How can you position the Cisco UCS C-Series servers for a customer concerned about the costs of changing to a unified computing environment? A. The Cisco UCS C-Series provides a cost-effective entry point to unified computing with scalability and flexibility for growth to other UCS solutions. B. The Cisco UCS C-Series offers the fastest processors, most memory, and most storage of any server on the market. C. The Cisco UCS C-Series offers a space-saving blade form factor for customers who need to expand data center flexibility without increasing infrastructure space. D. The Cisco UCS C-Series eliminates the need for management in the data center. /Reference: QUESTION 16 What is a feature of the Cisco UCS C-Series virtual interface card? A. It provides a centralized point of management for the UCS solution. B. It provides the Cisco extended memory technology. C. It provides 10 Gigabit Ethernet capability. D. It provides a flexible means of providing virtualization and policy compliance.

/Reference: QUESTION 17 Which format for output information using theshowcommand is intended to be easy to read? A. default mode B. CIMC mode C. YAML mode D. IPMI mode /Reference: QUESTION 18 What are two features of the Cisco UCS C-Series servers that are not available in the Cisco UCS B-Series? (Choose two.) A. virtualization and unified fabric B. rack-mount form factor for customers who prefer that option C. faster processor speeds D. multiple points of management E. higher internal storage with flexibility for growth Correct Answer: BE /Reference: QUESTION 19 Which of these is a characteristic of the Cisco UCS C-Series Rack-Mount server family? A. The series offers a cost-effective entry point to the rack-mount server profile and a migration to a full Cisco Unified Computing System solution. B. The series integrates both blade- and rack-mount form factors to offer the fastest server options on the market. C. The series enables an incremental, group server deployment model with a single point of entry into the Cisco Unified Computing System product line. D. The series is based on Intel's latest Itanium 9000 Series processors. /Reference:

QUESTION 20 What is a primary purpose of the BMC? A. offering agent and agentless management B. controlling access to and integration of virtual media C. controlling BIOS upgrading and downgrading D. providing out-of-band management /Reference: QUESTION 21 Feature for feature, in which three ways does a Cisco C250 M1 compare to an HP Proliant DL? (Choose three.) A. fewer PCIe slots B. fewer DIMMs C. less maximum memory D. more DIMMs E. more PCIe slots F. more maximum memory DF /Reference: QUESTION 22 Which of the Cisco partners offers Ionix ControlCenter to automate discovery, monitoring, reporting, planning, and provisioning of physical and virtual interfaces? A. BMC Software B. Microsoft C. VMware D. EMC /Reference: QUESTION 23 What are two features of the baseboard management controller BMC? (Choose two.) A. It is used for firmware updates. B. It provides a CLI interface for Cisco UCS C-Series servers. C. It provides KVM functionality on the Cisco UCS C-Series servers.

D. It runs off the main system processor to provide unmatched speeds. E. It provides a single point of management for the Cisco UCS C-Series servers. F. It runs independent of the main server to provide services even in the event of a processor failure. F /Reference: QUESTION 24 It is important to qualify customers before attempting to sell Cisco UCS C-Series servers. What are three important qualifiers to consider? (Choose three.) A. The customer has a strong relationship with HP. B. The customer is already using servers with a blade form factor. C. The customer has experience with Cisco ISR products. D. The customer is an early adopter of technology. E. The customer has experience with Cisco Nexus products. F. The customer has a strong relationship with IBM. BF /Reference: QUESTION 25 What command is used to finalize a firmware upgrade via the CLI? A. save B. commit C. run D. activate /Reference: QUESTION 26 How many Ethernet ports come standard on all Cisco UCS C-Series Rack-Mount Servers? A. one B. two C. three D. four Correct Answer: B

/Reference: QUESTION 27 How does the Cisco extended memory technology offer the most memory in a 2 RU server? A. It incorporates the memory available in the Cisco UCS B-Series blades. B. One virtual DIMM is mapped to four physical DIMMs. C. Four physically distinct DIMMs are mapped to a single logical DIMM. D. It offers twice the physical DIMMs found in other 2 RU servers. /Reference: QUESTION 28 A customer has data center needs for memory-intensive applications, including modeling applications. Which Cisco UCS C-Series server best fits this requirement? A. Cisco UCS C200 M1 B. Cisco UCS C210 M1 C. Cisco UCS C260 M1 D. Cisco UCS C250 M1 /Reference: QUESTION 29 In what way are converged network adapters an integral element of a unified fabric infrastructure? A. They simultaneously send TCP/IP communications over multiple 1-Gbps connections. B. They support the 4-Gbps Fibre Channel connections and use a PCIe interface to connect to the server. C. They simultaneously send either FCoE or TCP/IP communications over a single 10-Gbps connection. D. They use multiple integrated ASICs to separately perform 10-Gb Ethernet and Fibre Channel functions. /Reference: QUESTION 30 Which CLI command is used to put network configuration settings into the system configuration? A. shutdown

B. restore C. save D. commit E. show /Reference: QUESTION 31 Which command is used to remotely reset the server to its initial power-on state without cycling the power? A. power commit B. power shutdown C. power hard reset D. power cycle /Reference: QUESTION 32 How can you verify that the Cisco UCS C-Series server is in standby power mode? A. The Power Status LED is blinking green. B. The Power Status LED is dark. C. The Power Status LED is green. D. The Power Status LED is amber. /Reference: QUESTION 33 How is Cisco able to offer networking solutions that operate within the distributed hypervisor layer featuring Cisco VN-Link? A. using virtual Ethernet interfaces that are the virtual equivalent of physical network access ports B. providing a single point of management across the Cisco Unified Computing System solution C. using the virtual interface card to provide 10-GB Ethernet and FCoE D. manually provisioning virtual interfaces based on network policies

/Reference: QUESTION 34 How do you activate new firmware on the Cisco UCS C-Series server? A. It is activated by switching the server to the new firmware after a system reboot. B. It is activated by reinstalling the server operating system. C. It is activated when the firmware is installed on the server. D. It is activated by downloading the desired images from Cisco Connection Online and copying them to a network server. /Reference: QUESTION 35 How can you manage operating systems and applications on the Cisco UCS C-Series servers? A. using the CIMC B. by the serial port C. over the network by SSH or Telnet D. using the KVM console /Reference: QUESTION 36 Which management solution provides standards-based Ethernet network access for the Cisco UCS C-Series servers? A. CNA B. IPMI C. BMC D. CIMC /Reference: QUESTION 37 When using CLI configuration commands on the Cisco UCS C-Series servers, why is it beneficial to commit multiple commands together? A. In order for commands to be implemented at various levels of the CLI hierarchy.

B. The commands are implemented in reverse order, making it obvious which command has failed by determining which commands have been implemented. C. If one command fails, the successful commands are still applied. D. To view failed commands in order via the CIMC log. /Reference: QUESTION 38 How does the CIMC protect the network from intrusions for the Cisco UCS C-Series servers? A. It provides power to the server even in the event of a processor failure. B. It uses IP blocking. C. It interacts with Cisco UCS Manager to provide centralized security. D. It has an internal firewall that can be configured according to network policies. Correct Answer: B /Reference: QUESTION 39 All Cisco UCS C-Series servers come standart with internal local storage that can be confiruged foe RAID. Which two RAID levels can be configured? (Choose two) A. RAID 0 B. RAID 1 C. RAID 3 D. RAID 4 E. RAID 6 F. RAID 7 B /Reference: QUESTION 40 What is a feature of the Cisco UCS virtual interface card? A. It supports network interface virtualization and Cisco VN-Link technology. B. It provides both data networking and storage networking traffic on a single I/O adapter. C. It provides management support for the Cisco UCS C-Series servers. D. It provides FCoE capability in a virtualization environment.

/Reference: QUESTION 41 How does the Cisco extended memory technology offer the most memory in a 2 RU server? A. It incorporates the memory available in the Cisco UCS B-Series blades. B. One virtual DIMM is mapped to four physical DIMMs. C. Four physically distinct DIMMs are mapped to a single logical DIMM. D. It offers twice the physical DIMMs found in other 2 RU servers. /Reference: QUESTION 42 Which command is used to remotely reset the server to its initial power-on state without cycling the power? A. power commit B. power shutdown C. power hard reset D. power cycle /Reference: QUESTION 43 When using CLI configuration commands on the Cisco UCS C-Series servers, why is it beneficial to commit multiple commands together? A. In order for commands to be implemented at various levels of the CLI hierarchy. B. The commands are implemented in reverse order, making it obvious which command has failed by determining which commands have been implemented. C. If one command fails, the successful commands are still applied. D. To view failed commands in order via the CIMC log. /Reference: QUESTION 44 Which three interfaces are used to connect server management to the Cisco UCS C-Series server? (Choose three.)

A. Connect via one of the server's standard-profile PCIe card slots on the rear panel of the server. B. Connect to the service processor using the integrated IPMI. C. Connect a console using the two USB ports on the rear panel of the server. D. Connecting a KVM cable to the server console connector on the front of the server. E. Connect using the 10/100/1000 Gigabit Ethernet RJ-45 ports on the front panel of the server. F. Use remote management through the 10/100 Ethernet management port on the rear panel of the server. DF /Reference: QUESTION 45 What are two benefits of the Cisco extended memory technology? (Choose two.) A. It allows expansion of up to 384 GB of memory in a 2 RU form factor. B. It uses the virtual interface card to expand memory options up to 384 GB. C. It provides the cheapest memory expansion options in a 4 RU form factor. D. It can use 4-GB DIMMs for up to 192 GB for cost savings. E. It requires 8-GB DIMMs to expand memory to up to 384 GB. E /Reference: QUESTION 46 It is important to qualify customers before attempting to sell Cisco UCS C-Series servers. What are three important qualifiers to consider? (Choose three.) A. The customer has a strong relationship with HP. B. The customer is already using servers with a blade form factor. C. The customer has experience with Cisco ISR products. D. The customer is an early adopter of technology. E. The customer has experience with Cisco Nexus products. F. The customer has a strong relationship with IBM. BF /Reference: QUESTION 47 How do you activate new firmware on the Cisco UCS C-Series server? A. It is activated by switching the server to the new firmware after a system reboot. B. It is activated by reinstalling the server operating system. C. It is activated when the firmware is installed on the server.

D. It is activated by downloading the desired images from Cisco Connection Online and copying them to a network server. /Reference: QUESTION 48 What is a feature of the Cisco UCS virtual interface card? A. It supports network interface virtualization and Cisco VN-Link technology. B. It provides both data networking and storage networking traffic on a single I/O adapter. C. It provides management support for the Cisco UCS C-Series servers. D. It provides FCoE capability in a virtualization environment. /Reference: QUESTION 49 How is WebBIOS used to set up RAID controllers? A. It enables users to create and manage RAID configurations on LSI SAS controllers. B. It allows administrators to adjust topology views from the controller and disk enclosure down to the logical and physical drive level to manage RAID volumes. C. It provides operating system-level software tools to efficiently manage all RAID controllers across the Cisco UCS C-Series server family. D. It provides integration with Intel RAID Controller Drivers once the operating system is installed. /Reference: QUESTION 50 How does the CIMC protect the network from intrusions for the Cisco UCS C-Series servers? A. It provides power to the server even in the event of a processor failure. B. It uses IP blocking. C. It interacts with Cisco UCS Manager to provide centralized security. D. It has an internal firewall that can be configured according to network policies. Correct Answer: B /Reference:

http://www.gratisexam.com/