MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Similar documents
MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

MYRIAD RTU REMOTE TELEMETRY UNITS INSTRUCTION MANUAL

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

700 SERIES TPC TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Global Water globalw.com. Global Water. Instrumentation, Inc.

Tempco Instruction Manual

Global Water Instrumentation, Inc.

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

SP6R Level Controller Operation Manual

LCI User Manual mantracourt.com

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

5504 Thermocouple Analog Input Module

User's Guide. MiniTec TM Series Model MN25 MultiMeter

MODEL SIB-V245 / V453

POWER SERIES Plus. 3 in 1 AC Voltage. Digital Switchboard Meter. User s Manual IM2493VVV-2

Series 8000 RF Signal Switch Solution

Series 8000 RF Signal Switch Solution

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1

EX-RC1 Remote I/O Adapter

LCI Load Cell Junction Box with Fault Monitor

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

V E1B Snap-in I/O Module

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

PM Series Power Meter

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

AirTest Model CN9000 Series Sensor Controller

V E2B Snap-in I/O Module

POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

FLOW MONITOR & TRANSMITTER

Resolver to Digital Expansion Board

Digital Lighting Systems, Inc.

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Durant Eclipse Series Digital Panel Meters Durant Durant Visit our Web Site at

AD-7830 Servo Amplifier

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

CONTROL MICROSYSTEMS Differential Analog Input Module. Hardware Manual

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

CDD Carbon Dioxide Transmitter

SERIES CMT CARBON MONOXIDE GAS TRANSMITTER

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

FLS M9.06. ph/orp MONITOR

NFC110. Flow Computer For Low Pulses FEATURES

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

CTS-M5 TOXIC GAS TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE MANUAL. Automation Components, Inc.

High Voltage DC Meter

9500 and 9600 I/O Card Installation Instructions

PWRguard PLUS Spring City Drive Waukesha, WI

Table of Contents. 1 Introduction Introduction Front Panel Description Rear Panel Description 3

Operating Instructions. For. Level Control Module. Model SSR 1000

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

Digital Lighting Systems, Inc.

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro

MODEL 8000MP LEVEL SENSOR

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

User's Guide. Extech AM A AC Analog Clamp Meter

Rotork Fairchild PAX1 Linear Actuator User s Manual

24/7 Sprinkler Monitor. The Ultimate Rain/Freeze Sensor

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

Global Water Instrumentation, Inc.

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Plus-X 300. Installation and Operation Manual

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

M-SWITCH SWITCH INPUT IN GAS CONTROL SYSTEM INSTALLATION OPERATION AND MAINTENANCE MANUAL

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

XT-9100 Technical Bulletin

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

FLS M9.06 PH/ORP MONITOR. safety instructions. packing List

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

WS115 BREAKOUT ADAPTER USER MANUAL

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

HIGH-VOLTAGE DC METER

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Product Description. S&C IntelliNode Interface Module. Table of Contents. Instruction Sheet

OZONE SWITCH Model OS-6. OS-6 Features

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

TC-9102 Series Surface Mount Temperature Controllers

AUTOMATION. Operator s Manual. PG5 Digital Pressure Gauge

ES-600 Ozone Controller Operation Manual

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

BCM2 Series Branch Circuit Monitors Quick Setup Guide

PCM-7140 Pulsed Current Source Operation Manual

Transcription:

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114

2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 7 Dwg #: 04-143-2 Analog Input Analog Output Digital Input Digital Output PROGRAMMING AND INITIAL SETUP... 8 Input Range Selection Terminal Block Detail Initial Setup & Programming Overview/Key Description TROUBLESHOOTING & MAINTENANCE.. 15 APPENDIX A 17 WARRANTY 18

3 INTRODUCTION: The Sigma Myriad QLC (Monitor/Controller) is a 4-channel microprocessor based, state of the art, process/level monitor/controller offering unmatched performance and full user configurability. The QLC is used with primary measuring devices, whose input signal is compatible with common analog outputs 4/20MA, 0-5VDC, 1-5VDC, and 0-10VDC. Process indication for each channel is displayed in both numeric and graphic format on the QLC s graphic LCD display along with the current status of the unit s 4 relay outputs. All aspects of the instrument are user configurable through the plain English menus and combinations of the 5 user data key push buttons. Available in 2 styles of mounting, ¼ DIN (4 x 4 nominal) and wall mounted Nema 4X enclosures, the Myriad QLC is suitable for installation in all industrial environments. ORDERING INFORMATION: 1/4 DIN Case Wall Mount Nema 4X Sigma Myriad-QLC Sigma Myriad-QLC-N4X SPECIFICATIONS: ANALOG INPUT (4 ea.) Analog, 4/20MA, 0-5V, 1-5V, 0-10VDC, isolated with common negative, +-0.1% accuracy. DIGITAL INPUTS (4 ea.) Digital 10-30V AC or DC, 120 or 240 VAC (requires external resistor). ANALOG OUTPUT: (4 ea.) Analog, with common negative 0-20MA, 4/20MA, 0-5V, 0-10V (voltage output requires a resistor). DIGITAL OUTPUTS: (4 ea.) Opto isolated, solid state, open collector, 100MA 30VDC max. RELAY OUTPUTS: (4 ea.) SPDT, Form C 5A Relay DISPLAY: LCD, 128 X 32 pixel bitmapped graphic display LOOP POWER: 24VDC regulated output, 100MA max.

4 5 USER KEYS: Up, Down, Left, Right, Enter ACCURACY: 0.1% of calibrated span LOCKOUT: User password, user configurable LINEARIZER 20 point programmable for non linear inputs INPUT IMPEDANCE: Voltage 100K, current 100 OHMS POWER: 120VAC (230VAC available) ENVIRONMENTAL: Operating, 0-65 C Storage, -40-80 C R.H., 0-90% non condensing ENCLOSURE: ¼ DIN, ABS plastic 96 X 96 X 150MM FRONT PANEL: Gasketed Nema 4X ACCESS: Chassis & boards remove from front of case. TERMINAL STRIP: (40) Pluggable for ease of wiring 28 16 AWG CONNECTIONS: Removable screw terminal blocks 28 16 AWG wire. CONTROL OUTPUTS: 4 relay outputs, user programmable, SPDT Form C relays 5 AMP. 4 digital outputs. OUTPUT ANNUNCIATION: On board piezo buzzer WATCHDOG CPU ACTIVITY MONITOR

5 PROGRAMMING: Menu based, all parameters and setpoints are user configurable via menu prompts and user keys. The preconfigured screens and pull down sub menus with English prompts assures rapid setup and commissioning. 1 YEAR WARRANTY OPTIONS: Expansion cards, networking M.V. NET: Network allows multiple units to be connected together for distributed applications, remote monitoring SCADA applications. EXPANSION CARDS: Significant expansion is possible via additional control boards and MV networking. (Consult factory for details.) FEATURES: Microprocessor Based Graphic LCD Display 5 Function Keys 20 Point Linearization Isolated 24VDC Sensor Power 4/20MA, 1-5V, 0-5V, 0-10VDC Input 4 Analog Input 4 Analog Output 4 Digital Inputs 4 Digital Outputs 4 Form C Relay Outputs Fully User Programmable in English 2 Ea. RS485 Ports (Programming and SCADA)

6 WIRING DETAIL Inputs/Output see Dwg # 04-143-2! CAUTION All electrical wiring must be in accordance with all local state and national codes that apply. Do not exceed the rated current of the D.C. power supply (100MA) or the form C relay outputs (5A/240VAC resistive). WARNING Hazardous voltages are present within the enclosure. Installation or service should only be carried out by trained personnel.

7

8 PROGRAMMING & SETUP The Myriad QLC offers multiple Main screens allowing the user to view the four input channels in different ways. The options are as follows: Individual Channel Screens: Shows a selected channel in numeric and graphical formats with engineering units and channel number. Selected Channel # Process Value Engineering Units Graphical Process Indicator CPU Activity Monitor Press buttons to advance through each channel in this format and to the following displays. Combination Screen: Shows all channel values in numerical format with channel number indicators. Channel # Process value for channel 2 Displayed value will appear larger depending on the resolution (decimal place) selected. Bargraph Screen: Shows all four input values as vertical bar graphs with channel numbers. Channel # Vertical Bargraph Digital Status Screen: Shows the status of the digital inputs, relay outputs and digital outputs for each channel.

9 In the example shown above, relay 2 and 4 are active, digital output 2 is active and digital input 4 is active. Any active point will be indicated as shown. From any of the status screens press ENTER to access the password screen and the programming screens. Enter user selected password (factory default is zero) with the up and down keys, then with arrow buttons, move cursor to next Press ENTER to access menu 1 In this screen user access is provided for. SCALE AOUT - SETPOINTS - DIN - Permits analog scaling of each analog input Permits analog scaling of each analog output Permits sets values for relay and digital outputs for each channel Allows the user to set the condition of a digital input With the desired item highlighted, press ENTER to access the menu. Scale: Press ENTER to select scaling for channel 1 or use the buttons to select the desired channel, press ENTER to access scaling for input 1.

10 Using the buttons, scroll to NEXT, press ENTER to move to linearized screen. NOTE: If the application is linear between minimum input signal and maximum input signal, i.e. 2 point, then scroll the cursor to NEXT and press ENTER to continue the scaling process. Note on non linear inputs The Myriad QLC offers a 20 point linearizer which allows the user to customize the indicated display for 20 points of input signal. This feature is often used to read volume in a non-linear vessel such as a horizontal tank with domed end caps. a strapping table must be created to allow the display to be linear with the resultant non-linear input signal. If the user required a non-linear display, scroll the cursor to # OF POINTS and use the arrows to select the number of calibration points required, then select NEXT and press ENTER to continue. Decimal Point Selection: Use buttons to select number of digits to be displayed to the left of decimal point, scroll to NEXT, press ENTER and use this screen to enter the number digits to appear after the decimal point. Scroll to NEXT and press ENTER to proceed to the Input Text screen. Input Text: When SCALE MENU is complete the INPUT TEXT menu is the last menu in the scaling process.

11 This screen allows the selection of several engineering units. With the cursor on the default value as shown, press the buttons to select between FEET OF WATER PSI GALLONS LITERS UNITS INCHES OF WATER Once the selection is made select NEXT and press ENTER. Proceed to: Input Filter: Input filtering is used to prevent NOISY signals from causing false alarm trips. Use the keys to change the amount of filtering applied to the input signal. O is no filter and 10 is high filter. Once the selection is made select NEXT and press ENTER to return to Menu 1. The scaling process is now complete. Select NEXT and press ENTER to move to the analog scaling screen. Input Scaling to Engineering Units: NOTE: This screen sets what the Myriad QLC displays in its default screen for the selected input. The example shown above will display 0.0 units when the input is 4.00 MA. Both the input and the display at that input can be changed for different requirements.

12 A) With the cursor selecting INPUT = 4.00 use the buttons to change the input value for the required displayed value. B) Use the buttons to move the cursor to the display value and the buttons to change the desired display for the previously selected input. Once complete, scroll to SAVE, press ENTER to access INPUT SCALE 2 screen. Follow the steps outlined above to set the values of input and display for input Scale 2. When complete with scale 2, scroll the cursor to the DONE position and press ENTER to move to programming screens for input #2 and repeat the above steps. After setting all four input channel parameters, return to MENU 1 and select AOUT to program analog outputs for each channel. Analog Outputs: Using the buttons as described previously, select and adjust the values required for the analog output for channel 1. Both the output value and the display value for that output can be selected. When complete, select NEXT and press ENTER. This will bring up the scaling window for analog output 1 point 2 which is set as before. When complete scroll to DONE and press NEXT to move to analog output settings for channels 2 4. When complete, return to Menu 1 and select SETPOINTS to access the setpoint menu. Setpoints: NOTE: Each channel is provide with one SPDT Form C relay output and one 24 VDC digital output.

13 Using the keys as before, enter the ON and OFF values for both relay and digital outputs for each channel. Continue this process for all relay and digital outputs. Return to Menu 1 and select DIN to program digital inputs. DIN: The Myriad QLC is provided with four digital inputs which when activated will turn on their respective relay outputs, i.e. channel 1 digital input on will turn on relay output 1. The relay may be set to energize or de-energize by changing the selection in the highlighted item from Y (yes) to N (no). Scroll and set all digital inputs as desired and return to Menu 1 with the EXIT key. Menu 2: Menu 2 is accessed from Menu 1 by selecting NEXT and pressing the ENTER key. Peaks: The PEAKS window shows a record of the highest and lowest value for each screen since the last peak reset.

14 To reset a channel to the current value, press the and simultaneously to clear channel 1, the and for channel 3, the and for channel 2 and the and for channel 4. From the Menu 2 window, scroll to SETUP and press ENTER to access the QLC s global settings. Password: Enter a desired password number with the keys. When complete scroll to NEXT and ENTER to the screen scroll window.! Once the password has been changed, make sure a record of the new password is retained. Access to the programming menus requires a correct password. Screen Scroll: Selecting ON in this display will cause the MAIN screens to scroll continuously to permit sequential viewing. With this value selected to OFF the user must press ENTER to view the MAIN screens. Once the desired setting is selected, move to the next settings screen. Screen Hold: Sets the time a screen will stay on the display before scrolling to the next screen.

15 Sensor Type: The user may choose to select the sensor input as a digital or analog. Selecting digital will only allow the QLC to turn on and off a relay when the channel digital input is active. Most applications will utilize an analog sensor. When all programming is complete, use EXIT and ENTER to return to the MAIN screens. MAINTENANCE AND TROUBLE SHOOTING MAINTENANCE: The Myriad QLC is a digital solid state device which requires no periodic maintenance. Occasional physical checks of the unit should be carried out for physical and mechanical security of mounting, terminal blocks, and electrical wiring. TROUBLE SHOOTING: UNIT LOCKS UP Recycle power to the unit by removing AC power, waiting 10 seconds and reconnecting power. WARNING NOTE: This. should be done by using the user provided circuit breaker or fuse, not by removing the power wires at the terminal block. Serious injury or death can occur if contact is made with the incoming ac power. LCD display goes dim or contrast is poor. Remove power from the unit, release the 2 rear mounting screws and slide the unit forward in its case approximately 1 inch. On the left side of the circuit board is an adjustable potentiometer. With a small screwdriver adjust this pot to allow alter the contrast to the desired amount. Return the unit to its normal position and secure the rear screws. DISPLAY REMAINS AT ZERO OR SHOWS NO CHANGE -- If the display remains at zero or shows no change but the process is changing, check for D.C. voltage on the loop. With 2 wire (4/20MA) instruments check with a D.C. voltmeter at the level instrument, by disconnecting the level instrument from its terminals ( AI1, AIC) and measuring across these terminals with a D.C. voltmeter for the presence of 24VDC.

16 If D.C. voltage is present, reconnect the negative wire of the supply and insert a milliamp meter between the positive wires. The loop should provide a signal between 4 and 20 MA. If no current is present or the current exceeds 20MA consult the level instrument supplier. If D.C. voltage is not present check the user supplied power supply or if using the Myriad supply measure across terminals 24VDC and AIC. If no 24VDC is present consult factory. If 24VDC is present check field wiring between the Myriad and the field device and recheck SCALE functions to ensure correct setup.

17 APPENDIX A SWITCH SELECTION OF ANALOG INPUT RANGES (Factory default 4/20MA). The range dip switches are located on the bottom of the main circuit board. Disconnect power, remove two rear screws, remove terminal strips and slide the entire unit out of its case. Turn the unit upside down to locate the range dip switches. SW1 SW2 INPUT 4 DESCRIPTION 0 0 Ain1 range = 5V 0 1 Ain1 range = 10V 1 0 Ain1 range = 20mA 1 1 Not Used SW3 SW4 DESCRIPTION 0 0 AIn2 range = 5V 0 1 AIn2 range = 10V 1 0 AIn2 range = 20mA 1 1 Not Used SW5 SW6 DESCRIPTION 0 0 AIn3 range = 5V 0 1 AIn3 range = 10V 1 0 AIn3 range = 20mA 1 1 Not Used SW7 SW8 DESCRIPTION 0 0 Ain4 range = 5V 0 1 Ain4 range = 10V 1 0 Ain4 range = 20mA 1 1 Not Used ON (1) 1 2 3 4 5 6 7 8 EXAMPLE ONLY

18 WARRANTY All Sigma Controls, Inc. products are warranted to be free from defective materials and workmanship for one (1) year from date of shipment. Sigma reserves the right to repair or replace at its option any product found to be defective. In no event shall Sigma Controls, Inc. be liable for any consequential, incidental, or special damages and the limit of its liability shall not exceed the purchase price of the supplied equipment. RETURN FOR REPAIR POLICY (WARRANTY/NONWARRANTY REPAIR) Return status can be determined upon factory inspection of returned equipment. A completed Return Authorization form must accompany all items returned for repair. Repairs will be evaluated as quickly as possible. Cost for non-warranty repairs will be provided before repairs are initiated and repairs will be completed only after approval by customer. 217 S. Fifth Street, Perkasie, PA 18944 215-257-3412