dmxlan node3 User Manual

Similar documents
dmxlan node6x User Manual

dmxlan node1s User Manual

DMX Tool Splitter 1 to 5 User Manual

dmxlan nodegbx 8 User Manual

Architectural Lighting Controller AC612 XU User Manual

dmxlan node8 10-port DMX Ethernet node Users Manual Software version 1.23

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

OWNER S MANUAL CD-2 V 1.3

Neets Switching Relay - 2. Installation manual

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

SOUNDSTICKS WIRELESS. Setup Guide. Downloaded from

HDMI 1x2 Splitter B-230-HDSPLTR-1x2 INSTALLATION MANUAL HDMI OUT 2 HDMI OUT 1 B-230-HDSPLTR-1X2 POWER HDMI IN

U-300 Unity Amplifier User s guide

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-320-1CAT-HDIR

OWNER S MANUAL SINGLE CAT5E/6 3D EXTENDER B-200-1CAT-HDIR. Receiver

INSTALLATION MANUAL. HDMI 1x4 Splitter B-230-HDSPLTR-1x4. B-230-HDSPLTR-1x4 HDMI OUT 4 HDMI OUT 3 HDMI OUT 2 HDMI OUT 1 HDMI OUT 4 HDMI IN

Plug-in wireless speaker

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

DUAL LASER PACK & CONTROLLER USERS MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

User Manual ABS Molded Powered Loudspeaker MODEL: PB15PKG. QUESTIONS / COMMENTS CALL or pr o.com

IA1000. Integrated Amplifier with USB / SD Inputs IA1000. QUESTIONS/COMMENTS CALL or

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

C-300 Preamplifier User s guide

U-150 Integrated Amplifier User s guide

Quick Guide. ENC-H Video Encoder XX

CANTEEN 6000 Portable Battery Pack NAP-30. Instruction Manual Please read carefully before use and keep for future reference.

LTC 5121, LTC 5141 Series 2- and 4-Position Economical Sequential Switcher

C ookie User Manual BC

RIO R22 & R44. Quick Start Guide for all variants

SUBWOOFER SYSTEM YST-MSW10

Users Manual. Pronomic TAS-18 Active Touring System

Instruction Manual. 5.1 Channel Cinema System with Remote Wirless and Glossy MODEL:LS 250

QSW16M 16 Chn PoE managed switch

HDMI MATRIX SWITCHER B-120-HDMATRIX-4x4/8x8 CONFIGURATION UTILITY MANUAL

WELCOME SAFETY INSTRUCTIONS

HDBaseT EXTENDER B-520-TX-230-IR B-520-TX-330-IR INSTALLATION MANUAL

Owner s Manual. MOON Series 320 S. Power Supply

THANK YOU! CR120H. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

MODEL 805 USER MANUAL

5 B&W Rear View System Camera

Lightshow Box with Speaker

CPD SERIES OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier.

Monochrome Camera. Features. User manual

CG800H SERIES USER MANUAL ZIGBEE WIRELESS SCENE CONTROL PANEL VERSION JANUARY, Disclaimers and Copyright

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BeoLink Active. Setting-up Guide

Integrated Amplifier with USB / SD Inputs IA1200

User Manual for: Professional DJ Multi Beam LED Seashell Stage Effect Light with DMX. MODEL: LG8xSEA

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

DLHD2100 Owners Manual

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up. Roth BAR2 LX Manual UK VJ.indd 1 19/06/ :07

Video Surveillance System with 2 Indoor/Outdoor Night Vision Cameras

Classic Kiosk. User Guide. Before operating the unit, please read this manual thoroughly, and retain it for future reference

HEMC INSTALLATION GUIDE

VOICE-ACTIVATED INTERCOM SYSTEM

FOOT CONTROLLER FCV100

Instruction Manual Please read carefully before use and keep for future reference.

CS-MP125 INSTRUCTION MANUAL. Dual Alarm Clock Radio with Universal Dock for ipod. Please read this manual carefully before operation.

HARD DRIVE EXPANSION BAY DESIGNED FOR THE DIGIMERGE BLADE

Azimut. Minimalist design, maximum connectivity. Reference Guide

USB 2.0 SR. Extender over one CAT-5 Cable. User Manual EXT-USB2.0-SR. Version A1

Kam StarWash Multicolour wash effects with green & red star cluster laser

GigaCore 16Xt. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

BIOREP TEMPERATURE MONITOR MODEL No: BTM-01 USER MANUAL. Page 1 of 8

GigaCore 16RFO. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev3. English

Power LED Beam 56 Narrow

MP SERIES PROFESSIONAL POWER AMPLIFIER

1/4 Guitar / Mic input

Roth BAR 2LX High-Power Soundbar with Wireless Subwoofer. Turn it up.

SX2200 Series INSTALLATION INSTRUCTIONS. Electronic Systems Protection, Inc 8001 Knightdale Blvd. Suite 121 Knightdale NC 27545

THANK YOU! Crush PiX 20L. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

DAB A d a pt e r 3+ Dear Customer,

English MP210. Français. Multimedia Speaker. User Manual. Please read this manual carefully before operating the Speaker System

9 Digital Photo Frame NF-900. Instruction Manual Please read carefully before use and keep for future reference.

CONTENT COMPONENTS OF PROJECTOR... 2 SPECIFICATION... 3 INSTRUCTION MANUAL... 3 CHARGING THE PROJECTOR... 3 SET UP... 4

Operating Instructions

Us U er e r G u G i u de d AX A 3 X DA D N A T N E T I/O / O Car a d r d

KS-SB200 BOOM BOX INSTRUCTIONS LVT B [J]

Innovative K5 Palm Size LED Projector.

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

Versadrive SC-26 Speaker Management System

Cluster FX-Bar. Portable performance lighting and laser rig

WARNING! CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE COVER OF THIS UNIT. THERE ARE NO USER

Bluetooth Portable Speaker Slate MODEL:CAB PLEASE READ CAREFULLY BEFORE OPERATING THIS EQUIPMENT

CR6S Stereo Micro Crush

HSC-42. HDMI 4k2k Video Up/Down Scaler

PCM60A 100W MAX P.A. AMPLIFIER.

User`s Guide SBAR-51. Sound Bar and Docking Station

IMPORTANT SAFETY INSTRUCTIONS. 7) Do not block any ventilation openings. Install in accordance with the manufacturer s instructions.

FOOT CONTROLLER FCV100. Quick Start Guide. Ultra-Flexible Dual-Mode Foot Pedal for Volume and Modulation Control

P75 Dual Source Power Amplifier Installation Manual

MPF-1, Mains Power Filter User Manual

User Guide. JBL Professional UniAmp Power Amplifier Module Model 1214

VeniceU16/VeniceU24/VeniceU32

APT20. User Manual.

HP-101 HEADPHONE AMPLIFIER

Bluetooth Headphone FCC ID:OR8-T1

7-Port Fast Charging Station NAP Instruction Manual Please read carefully before use and keep for future reference.

Transcription:

dmxlan node3 User Manual

dmxlan node3 User Manual The ELC dmxlan node3 has 3 bi-directional DMX ports to convert from or to sacn, Art-Net or Shownet. An internal switch provides a second Ethernet port for a local lighting desk or additional Ethernet switches or nodes. The node3 can be outfitted with fully isolated DMX ports and Power over Ethernet. The ELC dmxlan node3 is available in the following variations: DLN3T DLN3T _FI DLN3T POE DLN3T POE_FI DLN3S DLN3S_FI DLN3W DLN3W_FI DLN3DIN DLN3DIN_FI truss mount truss mount fully isolated truss mount Power over Ethernet truss mount Power over Ethernet fully isolated surface mount surface mount fully isolated recessed wall mount recessed wall mount fully isolated DIN version DIN version fully isolated Features 3 Bi-directional DMX ports on the rear panel, XLR, RDM compatible Supports sacn, Art-Net & Shownet 2 Ethernet ports (Neutrik Ethercon) 10/100MBit with integral Ethernet switch Remote programming and monitoring, with remote fixture parameter override DMX Input normal or backup DMX Output normal, HTP, priority merging, softpatch (channel by channel), programmable merging with DMX channel control Local control via backlit display, rotary encoder/selector pushbutton Support for WYSIWYG, ESP, Capture

Versions Truss Mount (DLN3T / DLN3T_FI) The Truss Mount version of the node3 has a built-in power supply and is equipped with 3 DMX ports and 2 Ethernet ports (both with Neutrik Ethercon) located on the back of the device. The DMX ports are bi-directional so they can function as input or output. The unit has an M10 nut on the bottom and a safety eye. The DLN3T is also available in a fully isolated version (DLN3T_FI). All node3 Truss Mount versions can be mounted in a 19 rack using the ELC Rack Mount Kit (ELC-RMKIT). Truss Mount Power over Ethernet (DLN3TPOE / DLN3TPOE_FI) The Truss Mount Power over Ethernet version of the node3 has specifications identical to the regular node3 Truss Mount, except for the power supply. This version is powered by PoE instead of a built-in power supply. The PoE version of the node3 Truss Mount is also available in a fully isolated version (DLN3TPOE_FI). Surface Mount (DLN3S / DLN3S_FI) The Surface Mount version of the node3 can be mounted onto a wall. The Surface Mount unit has 3 bi-directional DMX ports located on the front of the device. The DMX ports can be ordered in male or female version (any combination is possible), as well as a version with fully isolated DMX ports (DLN3T_FI). There is also one Ethernet connection (Neutrik Ethercon) on the front of the node3 SM. Another internal Ethernet connection (RJ45) is located on the back of the device. This is the main Ethernet input and requires a PoE switch as its power supply. To gain access to the internal Ethernet connection, a technician must open the housing of the node3 by removing the four screws located along the sides of the front panel. Wall Mount (DLN3W / DLN3W_FI) The Wall Mount version features the same hardware and specifications as the Surface Mount version, but the housing is designed for recessed wall mounting. DIN Version (DLN3DIN / DLN3DIN_FI) This DIN-rail mounted Power over Ethernet version connects 3 bi-directional DMX ports to an Ethernet network, and an internal switch provides a second Ethernet port for a local lighting desk or a PC running ELC dmxlan control/management freeware or additional Ethernet switches or nodes. The DIN version of the node3 is also available in a fully isolated version (DLN3DIN_FI).

Connections Network 10/100 Mbit Ethernet (on Neutrik Ethercon or RJ-45) The network connection uses a standard UTP network connection. DMX port pin out Pin Description 1 Ground/screen 2 Data 3 Data + 4 5 All DMX ports are bi-directional (can act as input or output) with RDM preparation and can optionally be supplied in a fully isolated (FI) version. The ports also have internal 120 Ohm terminator resistors and line biasing for RDM. This product may only be used for controlling dimmers and moving lights. Using the product outside of these specifications will remove all responsibility from the supplier.

Operation The dmxlan node3 can be operated in 2 ways; either through the front panel or the dmxlan control software. The software can be downloaded from the ELC website at www.elclighting.com. The front panel control options will be explained below. Main display Encoder +/- Press Encoder Change the view on the display to see the device ID, IP address, status, software version, etc. Enter the setup menu Setup menu Encoder +/- Select one of the setup items: Exit Setup DMX port 1 DMX port 2 DMX port 3 Set ID Network Options Press Encoder Activate the selected option DMX port menu Select mode Edit mode

In select mode: Encoder +/- Press Encoder In Edit mode: Encoder +/- Press Encoder Select different item Go to Edit mode Change the value of the item Go to Select mode DMX port as output When a port is set up as a DMX output it can operate in the following modes; Disabled the DMX output is disabled Outzero the DMX sends out a DMX test signal with all channels at 0% Single the output sends out the DMX values of the selected (primary) Art-Net universe. The DMX output is enabled the first time it detects the DMX universe on the network (or internal DMX inputs). If the universe on the network fails, the DMX output will go into DMX hold. Dual HTP like single, but merges two DMX universes (primary and secondary) in highest takes precedence. Dual LTP like dual HTP but in latest takes precedence (on a channel by channel basis). DMX port as input When a port is set up as a DMX input it can operate in the following modes; Disabled the DMX input does nothing Normal any valid DMX is sent onto the network (and internal use) using the selected universe (Art-Net) Backup the DMX input will not send data if the selected universe is present on the network. If the selected universe is not present on the network for several seconds and the input has valid DMX, then it will send DMX data. If another sender starts sending the same universe, the input will go back into backup mode.

Set ID If the node3 is being controlled by the dmxlan software, an ID can be assigned to the unit. The ID can be useful for preprogramming of the network. Use the encoder in Select and Edit mode to change the 3 digits of the ID. The digits are in hexadecimal format (16 possibilities 0-9, A-F). This means you can have up to 4095 different ID s in the system (ID 000 means that the ID is not used ---). Network options Use the Select and Edit modes to change the values of the IP address and the netmask. For normal Art-Net operation, the netmask should be set to 255.0.0.0 and the IP address should be between 2.0.0.1 and 2.254.254.254. Technical specifications node3 Truss Mount Power: 100-240 VAC 47-440 Hz 10VA max Dimensions: 200 x 160 x 45 mm Weight: 1.2 kg node3 Surface Mount Power: Power over Ethernet required on the internal connection Dimensions: 140 x 85 x 50 mm Weight: 0.6 kg node3 Wall Mount Power: Power over Ethernet required on the internal connection Dimensions: 165 x 115 x 40 mm Weight: 0.3 kg node3 DIN Dimensions: 105 x 90 x 60 mm Weight: 0.2 kg

General safety instructions Read all instructions - especially the safety requirements - in the user manual before use. Save these instructions - the safety and operating instructions should be retained for future reference. Carefully follow all instructions. Cleaning Disconnect all connected supply and signal cables before cleaning the unit. Clean with a dry cloth. Do not use any liquids or aerosols on the unit. Usage Do not use the unit near water or moisture. - Do not block any ventilation openings, they are necessary for the essential airflow within the unit and protect it against overheating. - Install in accordance with the manufacturer s instructions. - Do not insert any objects through the ventilation slots of the unit, as these could come in contact with live parts or could cause short circuits. This could cause electric shock and/or fire. - Do not install near any heat sources such as radiators, stoves or other apparatus (including amplifiers) that produce heat. - Unplug this apparatus during lightning storms or when unused for long periods of time. Do not place the unit on unstable surfaces. Do not place any objects on the power cord. Protect it from being walked on or pinched particularly at the plugs and the point where they exit from the device. If the power cord or the mains plug is damaged, let a qualified technician replace it immediately. - Do not defeat the safety purpose of the grounding plug. A grounding plug has two blades and a third grounding connection. The third grounding connection is provided for your safety. If the provided plug does not fit in your outlet, consult an electrician for replacement of the obsolete outlet. Servicing Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way such as; damage to the power supply cord or plug, spillage of liquids, objects falling into the apparatus, exposure to rain or moisture, abnormal operation or falling damage. In all of the previous conditions, disconnect the main plug immediately and call your distributor or technical support!

Cautionary instructions Maintenance and service of the device may only be carried out by qualified service personnel, as when opening and /or removing coverings of the device live parts may be exposed causing the risk of an electric shock. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE

Declaration of Conformity We, Manufacturers name: ELC lighting b.v. Manufacturers address: Weerijs 8 5422 WV Gemert the Netherlands Herewith take the full responsibility to confirm that the product Product Category: Name of product: Lighting control equipment ELC-DLN3T / ELC-DLN3T_FI Which refer to this declaration are manufactured in the Netherlands and complies with the following product specifications and harmonized standards: Safety: EMC: ROHS (II): LVD (Low Voltage Directive) 2014/35/EU, EN62368-1 2014/30/EG, EN55032 2011/65/EU With the presumption that the equipment is used and connected according to the manual, supplied with the equipment. All signal input- and output connections must be shielded and the shielding must be connected to the ground of the corresponding plug. Gemert, February 16, 2018 ing. Joost van Eenbergen