MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

Similar documents
Series MPM-815H 150W PFC MEDICAL ATX POWER SUPPLY

Watts. xppower.com. General. Input. Environmental. EMC & Safety. Output. IT & Medical Approvals. Energy Efficiency Level V, CEC2008 & EISA 2007

60 Watt Medical (MWLT)

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Series MPM-X12Y 120W PFC MEDICAL POWER ADAPTER

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

275 Watt Medical Ultra low profile

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

40 & 60 Watt Models. Low Leakage Current. EN61000 Compliant. Single & Multiple Outputs. Cover Kits Available

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

Safety Standards. Model Number:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Safety Standards. Model Number:

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

Safety Standards. Model Number: Unit Weight:

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Safety Standards. Model Number:

Safety Standards. Model Number:

MVAD040 Series 40W 2" x 4" AC-DC Power Supply Converter

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY. Revision History

EMH Series. 250 W & 350 W Forced-cooled. Industry Standard 3 x 5 x 1.43 Format. IT & Medical (BF) Approvals. 80 V VAC Operation

Safety Standards. Model Number:

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

5 x 8.5 x 1.61 Inch Form Factor. Convection Cooling Rated. Approved to EN Dual Fusing. Current Sharing. Open Frame. Peak Power Capability

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 95% at 85V AC)

VP ELECTRONIQUE MASSY - Tel

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

350A Series MDS 350 A D 701 A A. Technical Datasheet Medical ATX Power Supply ATX 12V 1U Power Supply

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

Safety Standards. Model Number:

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

Safety Standards. Model Number:

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

TEK360M series is a fan-less 300W, U-frame, switching power supply with active PFC function for medical application. Rated Output Power.

Safety Standards. Model Number:

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Safety Standards. Model Number:

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

LPS. ME20 20W Single Output External Power Medical Series. Features

Universal Power Supplies

POWERBOX Medline 150 EBM04 Series W Single Output AC/DC Medical Switch Mode Adaptor, Desktop Style

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

C B. Models. Operating up to 5000m altitude 5 year product warranty

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

Safety Standards. Model Number:

PRODUCT SPECIFICATION File: EA-A0601HE-12 Model: SSA-0601HE-12 Date: Apr. 17, 2015

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Watts. xppower.com. General. Input. Output. Environmental. EMC & Safety. Compact Size. IT & Medical Approvals.

Enclosed Power Supplies

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

GSP750 Series. 750 Watts. AC-DC Power Supplies. Models & Ratings. Input

< 50 A max. (115 VAC) / < 70 A max. (230 VAC)

12-15VDC (12V±5%) 24-28VDC (24V±5%)

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Max Output Power Voltage. Convection Forced Convection Forced Nom Peak (2) Model Number (1)

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

HEC-100RTN-48QSCA Rev A1.0

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

Safety Standards. Model Number:

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

ECF40 Series. 40 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Output Voltage* (nom.)(adjustable)

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

500Watts Medical Single Output

ME to 30W Single Output External Power Medical Series. Features

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

ORDERING INFORMATION SEE PAGE 6

Safety Standards. Model Number

LFWLP350 SERIES 350 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.00

Constant Voltage Mode

Electrical Specification for: efo Wide range AC/DC Single 12V Output 400W Power Supply Telkoor Part Number: CUSTOMER SIZE CAGE CO

MMA-15 series. 15W Medical Grade Ultraminiature Switching Power Supplies. Single / Dual / Triple Outputs. Universal 90 to 264VAC Input

PRODUCT SPECIFICATION File:SSA Model : SSA Rev:A2 Date: Nov. 29, 2010

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

PMT. Safety Standards. Model Number:

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

Snaptec Australia Pty. Ltd.

MB2000ERUI. High Isolation, 1 x 2 20W, 4:1 Input Range DC/DC Con vert ers. Key Features:

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Medical AC-DC Enclosed Power Supply 24V 200W 2 x4 High Density / MDS-200APB24 AA

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Transcription:

SPECIFICATION FOR SWITCHING POWER SUPPLY M/N: Revision History Version Date Change Items Rev. 1.0 July.21. 2017 Established. Page 1

Models & Ratings FEATURES 650W medical power supply with force air cooling. Peak power up to of 750W. Optional digital function to read PSU data by USB connector. Single + multi output versions up to 5 outputs included 5Vsb. IP to OP 2xMOPP; IP to Earth 1xMOPP. Thermally efficient U channel chassis design. Automatically fan speed control. Design to meet medical safety regulations. Model Number Wattage (Rated / Peak) Output Voltage Min. Current Rated Current Peak. Current MPM-U653 650 W / 750 W V1 +12 V 0 A 48 A 56.3 A V2 +5.1 Vsb 0 A 2A ---- V3-12V 0 A 0.2A ---- V4 +5V 0 A 8A V5 +3.3V 0 A 8A Note: 1. Rated output is 650W with a built in fan model. In a open frame type with suffix U model name, it can be 450W(AC115V) at 50 C convection cooled environment. 2. The peak output only at input voltage more than 100VAC, and max. 1000mS. 3. See below Output Specification for detail test condition. 4. Initial setting voltage is at input 115VAC and all outputs at 60% rated load. 5. Total power is 650W. 6. Model no. coding: M P M U 6 5 3 X X X X 1 : D or B means digital version or basic version 1 2 3 4 2 and 3 : optional DC/DC daughter board with U653 and U655 model only. 4 : A or B or C or D means different mechanical part. (see Mechanical Details) Summary Characteristic Minimum Typical Maximum Units Notes & Conditions Input Range 85 115 / 230 264 VAC Universal input range. Input Frequency 47 50 / 60 63 Hz AC input. Efficiency 90 91 % At input 230VAC, rated load, 1.0 hr. warm up. Operation Temperature -20 +70 C Derate linearly from 50 C, become 50% load at 70 C. Weight 1650 g Dimensions EMC 229 (L) x 127 (W) x 65 (H) mm, Tolerance +/- 0.5mm. EN 55011, EN 60601-1-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 Safety IEC 60601-1, EN 60601-1,ANSI / AAMI ES60601-1:2005,CAN / CSA-C22.2 No. 60601-1:08 Page 2

Input Characteristic Minimum Typical Maximum Units Notes & Conditions Input Voltage 85 115 / 230 264 VAC Universal input range. Input Frequency 47 50 / 60 63 Hz AC input. Input Current 4 12.5 A Inrush Current 30 / 60 A Nominal AC Input Voltage (115VAC/230VAC), rated load. Nominal AC Input Voltage (115VAC/230VAC), one cycle at 25 C cold start. Patient Leakage Current 100/300 μa Normal Condition / Single Fault Condition Power Factor 0.92 Rated load @ 230 VAC Input Protection Dual non-user serviceable internally located AC input line fuse. Fuse:15A / 250VAC * 2pcs Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage Initial Set Accuracy 12 (V1) 5.1 (V2) -12 (V3) 5 (V4) 3.3 (V5) ±1 (V1) ±1 (V2) ±5 (V3) ±2 (V4) ±2 (V5) Minimum Load 0 A VDC Start Up Delay 2 / 1.0 Sec. Hold Up Time 16 ms Line Regulation Load Regulation Ripple & Noise Overvoltage Protection Overload Protection Short Circuit Protection Remote On / Off Remote Sense ±1 (V1) ±1 (V2) ±1 (V3) ±1 (V4) ±1 (V5) ±1 (V1) ±4 (V2) ±10 (V3) ±3 (V4) ±3 (V5) 120 (V1) 100 (V2) 120 (V3) 50 (V4) 50 (V5) % % % mv Initial setting accuracy is adjusted at input 115VAC and output at 60% rated load. Time required for initial output voltage stabilization. Nominal AC Input Voltage (115VAC/230VAC), rated load at 25 C. Nominal AC Input Voltage (115VAC/230VAC), rated load. Less than ±1% at rated load with ±10% changing in input voltage. Measured from 60% to 100% rated load and from 60% to 20%rated load (60% ±40% rated load). Measured at rated load by a 20MHz bandwidth limited oscilloscope and each output is connected with a 10µF Electrolytic Capacitor and a 0.1µF Ceramic Capacitor. For some reason the power supply fails to control itself, the build-in over voltage protection circuit will shut down the outputs to prevent damaging external circuits. Auto recovery. Fully protected against output overload and short circuit. Automatic recovery upon of overload condition. The power supply will be turned on when the power On/Off pin is connected to secondary GND. N/A Page 3

General Characteristic Minimum Typical Maximum Units Notes & Conditions Efficiency 90 91 % At input 230VAC, rated load, 1.0 hr. warm up. Isolation IP to OP 4000 VAC 2 x MOPP IP to Ground 1500 VAC 1 x MOPP (Screw head to primary) Switching Frequency 65 KHZ MTBF 148692 hrs. MIL-HDBK-217F at 25 C Power Good Signal (Only with SB model) Power Fail Signal (Only with SB model) When power is turned on, the power good signal will go high 100 ms to 500 ms after all output DC voltages are within regulation limits. The power fail signal will go low at least 1 ms before any of the output voltages fall below the regulation limits. Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Low temperature start up -20 C Some specification parameters maybe exceeded until after 20 minutes warm up period. Operating Temperature -20 +70 C Derate linearly above 50 C, performance curves will be provided after testing. Storage Temperature -40 +85 C Relative Humidity 5 95 %RH Non-condensing. Operating Altitude 5000 m Vibration 0.26 6.09 G Frequency Type: Sweep Frequency Frequency Range: 10~55 Hz Displacement: 1.0mm Sweep Rate: 60 minute / cycle Number of cycle: 1 cycle / axis Direction: X,Y and Z axis Page 4

Derating curve Performance curves of MPM-U653 EMC: Emissions Phenomenon Standard Class Notes & Conditions Conducted Radiated EN 55011 / CISPR 11 & FCC Part 18 EN 55011 / CISPR 11 & FCC Part 18 B B 1. Pass without enclosure. 2. Pass with or without a metal plate below the power supply. Harmonic Current EN 61000-3-2 D Voltage Flicker EN 61000-3-3 Note: 1. Above specification is applied with output equal or below 650W. For higher output power, please re-confirm with us. 2. Above specification is based on the test conditions of EN 55011 / CISPR 11 & FCC Part 18. If there is any question when the power supply is applied to the system, please contact us for assistance. Page 5

EMC: Immunity Phenomenon Standard Criteria Notes & Conditions ESD IEC 61000-4-2 A ±15KV air discharge, ±8KV contact discharge Radiated IEC 61000-4-3 A 10V/m EFT IEC 61000-4-4 A ±2KV Line & PE, 100KHz Surges IEC 61000-4-5 A L-N:±1KV, L/N-PE:±2KV Conducted IEC 61000-4-6 A Power Magnetic IEC 61000-4-8 A 30A/m 10V, 80% AM, 1KHz 150KHz~230MHz Dips and Interruptions IEC 61000-4-11 A A B B DIP: >95%, 0.5 cycle DIP: 30%, 25 cycles (Note 2.) DIP: 60%, 5 cycles (Note 2.) INT: >95%, 250 cycles Note: 1. Above specification is applied with output equal or below 650W. For higher output power, please re-confirm with us. 2. The test result of input 240Vac / 100Vac is criteria A / B. Safety Approvals Safety Agency Safety Standard Notes & Conditions TUV EN 60601-1: 2006+A11+A1+A12 CB IEC 60601-1: 2005+CORR. 1: 2006+CORR. 2: 2007+A1: 2012 Designed to meet (Medical 3.1 rd ) UL/cUL ANSI/AAMI ES60601-1, CAN/CSA-C22. 2 No. 60601-1 Designed to meet (Medical 3.1 rd ) Digital Interface Item Device class CDC Baud rate Protocol Output Real-Time Item (Note 1) Output Information Item (Note 1) Content Mini-USB Type B 12Mbps USB 2.0 Full-Speed, USB CDC class (RS232 Type) 19200 bit/s Magic Power Standard protocol Output Voltage Output Current Output Power Remote Signal PGPF Signal OTP Signal Model Name Firmware Version Rate Voltage Rate Power Note: 1. Customer can control the PSU ON / OFF and read above output data through the mini USB device with a PC. 2. If any other control / read function is needed, please contact Magic Power to check the modification. Page 6

Mechanical Details 1. MPM-U653-XXX-A: With AC inlet, open frame type Estimated size 229 (L) x 127 (W) x 65 (H) mm. Note: Optional daughter board for the digital function to read PSU data by mini USB type B connector and Magic Power software installed. Page 7

2. MPM-U653-XXX-B: With AC inlet, Fan and cover type Estimated size 229 (L) x 127 (W) x 65 (H) mm.. Note: Optional daughter board for the digital function to read PSU data by mini USB type B connector and Magic Power software installed. Page 8

3. MPM-U653-XXX-C: With input terminal block, open frame type, estimated size 229 (L) x 127 (W) x 65 (H) mm. Note: Optional daughter board for the digital function to read PSU data by mini USB type B connector and Magic Power software installed. Page 9

4. MPM-U653-XXX-D: With input terminal block, fan and cover type, estimated size 229 (L) x 127 (W) x 65 (H) mm. Note: Optional daughter board for the digital function to read PSU data by mini USB type B connector and Magic Power software installed. Page 10

Performance curve (Input voltage: 115Vac) Switching frequency ripple rated load Line frequency ripple rated load 50mV/div, 5uS/div 50mV/div, 5mS/div Output turn-on rated load Output turn-off rated load 5V/div, 100mS/div 5V/div, 10mS/div Hold-up time rated load OVP 60% of rated load 200V/div,5V/div, 20mS/div 5V/div, 10mS/div Page 11

Performance PG rated load PF rated load 5V/div,2V/div, 100mS/div 5V/div,5V/div, 20mS/div Step response 20%~100% of rated load Remote on off rated load 200mV/div, 2mS/div 5V/div,5V/div, 500mS/div Page 12

EMI: EN55011 B (Conduction) EMI: FCC B (Conduction) 230Vac/rated load 115Vac/rated load EMI: EN55011 B (Radiation) EMI: FCC B (Radiation) 230Vac/rated load 115Vac/rated load Thermal Considerations In order to ensure safe operation of the SPS in the end-use equipment, the temperature of the components listed in the table below must not be exceeded. Temperature should be monitored using J type thermocouples placed on the hottest part of the component (out of any direct air flow). See mechanical details for component locations. Component Temperature measurements at max. amb. Max Temperature T1 120 C Q2 120 C Q6,Q6A,Q7,Q7A 120 C C3,C3A,C3B,C3C 105 C C11,C11A,C11B,C11C,C11D,C11E 105 C Page 13