LON Module for Variable Speed Drive

Similar documents
QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

TXM1.8RB. TX-I/O Blinds module

Digital input modules

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

Room unit with PPS2 interface

Room unit with PPS2 interface

Rotary version, three-position control

Fast running actuators for air dampers

BACnet/IP Web Interface

AEW Pulse Adapter. Building Technologies

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Rotary actuators for ball valves

Interface converter for VAV compact controllers

Air damper actuators

RMZ790. Operator Unit. Building Technologies. Synco 700

INSTALLATION INSTRUCTIONS

TAC Xenta 301. Controller, Freely Programmable

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Mobile Data Collector

VAV modular controller

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Network node WTT56.. A6V _en--_c Building Technologies

M-bus RF gateway. Meters and Energy Cost Allocation WTT563-0C0000

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

Content. Product Description

Handheld Tool for VAV compact and modular controllers

Super universal modules

TAC Xenta 280 UC-01 UC-02 UC-03

PXR11 PXR12. System controllers DESIGO PX

Din Mounted Smart LonWorks Router

Airflow Pressure Sensor

Extension module for lighting control

VAV compact controller

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Automation station, compact series

Extension module for graphic Web functions for one automation station

Room Temperature Controller

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

TAC Xenta 101-VF. 3-Speed Fan Coil Controller. TAC Xenta

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Extension module for Web functions generic

SLX Series. Application Specific Controllers (SLX-ASC-FCU-L, SLX-ASC-HPU-L, SLX-ASC-RTU-L, SLX-ASC-UV-L)

Climatix programmable controller

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Electromotive actuators for combi valves

Heating Circuit Controller

Electromotoric actuator

FEATURES DESCRIPTION MODEL 110B. Power Supply

Extension module for BACnet over Ethernet / IP and graphic Web functions

General information. Display. Supply voltage. Input current. Encoder supply. Output current

LX Series Remote Input/Output (I/O) Controller

Electromotoric actuators

Resistance measuring module

Web interface BACnet/IP

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

1201L-1K RTD Controller. Revision 1.1. Nico Technology Ltd. 1 Rev.1.1

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

Automation stations modular series

General information. Display. Supply voltage

Infilex GD Multipurpose Data Gathering Panel Model WY5310

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display

General information. Display. Supply voltage

LTEC Heat Pump DDC Controller

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

24-hour room temperature controller

General information. Display. Supply voltage. Input current. Encoder supply. Output current

HVAC Products. Introducing the SED2 Variable Frequency Drives

General information. Display. Supply voltage. Input current

CTR21, CTR22, CTR23, and CTR24 Wall Modules

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Heating Circuit Controller

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Product Datasheet NK8231 CEI interface for a single subsystem

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Lonix Automation/BMS. Installation Manual.

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

TKL19 (RTUL19) Installation Manual. Tema1.0_L19_IM_1.0_EN Pagina 1 di 24

TAC Xenta 121-FC Programmable Fan Coil Application

Semi flush-mounted room temperature controllers with LCD

General information. Display. Supply voltage. Input current

Transcription:

5 193. LON Module for Variable Speed Drive SED2 Conforms to and is certified to the LONMARK Interoperability Guidelines enabling information sharing with other LONMARK products. LONMARK-compliant with variable speed motor drive profile number 6010 Uses Standard Network Variable Types (SNVTs) for communication, allowing the SED2 VSD to be configured, controlled, and monitored via the LONTalk network 48 SNVTs preconfigured for control/monitoring Modular snap-on design for simple installation and easy control system integration to any existing or new SED2 CE1N5193en Building Technologies

72 F Use Direct digital control of fans and pumps in HVAC applications over a LONWorks network SED2 VSDs can be configured, controlled and monitored via the LONWorks network. The SED2 LON module enables the SED2 to share information and interact seamlessly with all other LONMark products from multiple vendors. Typical system architecture Workstation Workstation/ Web Browser/ E-Mail Ethernet, TCP/IP, BACnet, HTTP, XML Internet/ World Wide Web Wireless Web Device, Cell Phone, Pager, etc. Network Manager LONTALK Network Network Manager Room Sensors LONTALK Network Repeater Programmable Controller Controller Controller Controller SED2 VSD Controller with LON module LONMARK Third Party Device Application functions The SED2 LON Module corresponds to 1 LON node that communicates with other LONpartners. 2/6

Ordering When ordering, please give type reference: SED2-LONI/F Product documentations CE1B5193en CM1U5192en CM1G5192en SED2 LON Module Operating Instructions SED2 Variable Speed Drives Operating Instructions Variable Speed Drives Commissioning Guide Mechanical design Modular snap-on design for simple installation and easy control system integration to any existing or new SED2 VFD Status LED Connector to SED2 VSD operator panel Disposal Service switch LON network connection The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 5193J02 3/6

Technical data Environmental conditions General unit data Norms and standards NOTE: Permissible ambient temperature Transport and storage Operation Permissible air humidity Transport and storage Operation Operating voltage -25 C +70 C (13 F 158 F) -10 C +50 C (14 F 122 F) 95 % r.h. 85 % r.h. (non-condensing) the LON module receives power through its SED2 VSD connection Processor type Neuron 3120 Processor clock speed 40 MHz Memory size 16 KB ROM, 2 KB RAM Status LED tri-color (green, orange, red), LED provides indication of current operating state Service Pin provides external activation of service pin message Physical Interface free topology: FTT-10 Connector short-circuit proof, isolated, FTT-10 bus connector Network terminator bus topology: 105 ohm at both ends free topology: 52.3 ohm close to the center of the network Network communication 78 Kbps (FTT-10) Output rates bi-directional and configurable transmission rates for output network variables Dimensions height: 161 mm (6-11/32 in.) width: 73 mm (2-7/8 in.) depth: 43.5 mm (1-23/32 in.) Interface uses Standard Network Variable Types (SNVTs) exclusively Node identification fixed, unique Neuron ID, software configurable node ID Configuration all drive parameters can be updated through network variables Feedback monitor actual values and drive status on output network variables Control drive control and frequency references are available through input network variables Conforms to and is certified to LONMARK Interoperability Guidelines LONMARK compliance LONMARK-compliant with variable speed motor drive profile number 6010 RoHS conformity conform For technical specifications on the SED2, see data sheet Variable speed drives SED2, Document No CM1N5192en. 4/6

Connection terminals LONTALK TP/FT-10 29 (P+) 5193A01 LONTALK TP/FT-10 30 (N-) Field wiring SED2-LON I/F terminals Cabling note This connection supports twisted pair, unshielded, polarity-insensitive, peer-to-peer communications at 78 Kbps. Recommended cable type For the bus cables of the SED2 LON modules, we recommend the exclusive use of shielded twisted pair cables. The following types of twisted pair cables have been tested and approved by Echelon: Cable type Wire diameter AWG Conductor cross section R loop /km nf/km JY(St)Y 2x2x0.8 TIA 568A Category 5 0.80 mm 20.4 0.503 mm 2 73 98 0,51 mm 24 0.21 mm 2 28 48 Maximum bus length The maximum transmission distances that can be covered depend on the selected bus topology and the type of cable used. For more detailed information, refer to LON Module Operating Instructions CE1B5193en 5/6

ON 1 2 Dimensions 73 5193M01 SED2 167.5 WARNING! DANGEROUS VOLTAGES DISCHARGE TIME 5 M IN ACHTUNG! GEFÄHRLICHE SPANNUNG ENTLADEZEIT 5 MIN 52.6 Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 2001 Delivery and technical specifications subject to change 6/6