Spectral analysis of non-stationary CT noise

Similar documents
Non-Stationary CT Image Noise Spectrum Analysis

Improvement of Efficiency and Flexibility in Multi-slice Helical CT

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Basics of treatment planning II

Comparison of Scatter Correction Methods for CBCT. Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis

Material for Chapter 6: Basic Principles of Tomography M I A Integral Equations in Visual Computing Material

CT vs. VolumeScope: image quality and dose comparison

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

Assessment of 3D performance metrics. X-ray based Volumetric imaging systems: Fourier-based imaging metrics. The MTF in CT

8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition

Contrast Enhancement with Dual Energy CT for the Assessment of Atherosclerosis

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration

Central Slice Theorem

Photon counting spectroscopic CT with dynamic beam attenuator

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

Cardiac Dual Energy CT: Technique

Feldkamp-type image reconstruction from equiangular data

Proton dose calculation algorithms and configuration data

Introduction to Biomedical Imaging

Iterative and analytical reconstruction algorithms for varying-focal-length cone-beam

S. Guru Prasad, Ph.D., DABR

Engineered Diffusers Intensity vs Irradiance

Simulation of Beam Hardening in Industrial CT with x-ray and Monoenergetic Source by Monte Carlo Code

Micro-CT Methodology Hasan Alsaid, PhD

DUAL energy X-ray radiography [1] can be used to separate

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

Energy resolved X-ray diffraction Cl. J.Kosanetzky, G.Harding, U.Neitzel

DICOM. Supplement 188 Multi-Energy CT Imaging. DICOM Working Group 21 Computed Tomography

A prototype table-top inverse-geometry volumetric CT system

Corso di laurea in Fisica A.A Fisica Medica 4 TC

A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY

Enhanced material contrast by dual-energy microct imaging

8/1/2017. Current Technology: Energy Integrating Detectors. Principles, Pitfalls and Progress in Photon-Counting-Detector Technology.

Digital Scatter Removal in Mammography to enable Patient Dose Reduction

AIDR 3D Iterative Reconstruction:

DETERMINISTIC 3D RADIATION TRANSPORT SIMULATION FOR DOSE DISTRIBUTION AND ORGAN DOSE EVALUATION IN DIAGNOSTIC CT

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

DUAL-ENERGY CT IN PROTON THERAPY

CoE4TN4 Image Processing. Chapter 5 Image Restoration and Reconstruction

Medical Image Reconstruction Term II 2012 Topic 6: Tomography

Optimisation of Toshiba Aquilion ONE Volume Imaging

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

Flying Focal Spot (FFS) in Cone-Beam CT Marc Kachelrieß, Member, IEEE, Michael Knaup, Christian Penßel, and Willi A. Kalender

A study on image quality provided by a kilovoltage cone-beam computed tomography

CIRCULAR scanning trajectory has been widely used in

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

An approximate cone beam reconstruction algorithm for gantry-tilted CT

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

Performance Evaluation of the Philips Gemini PET/CT System

45 µm polystyrene bead embedded in scattering tissue phantom. (a,b) raw images under oblique

A Novel Two-step Method for CT Reconstruction

BME I5000: Biomedical Imaging

Geometry Calibration Phantom Design for 3D Imaging

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Fits you like no other

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

EECS490: Digital Image Processing. Lecture #16

7/13/2015 EVALUATION OF NONLINEAR RECONSTRUCTION METHODS. Outline. This is a decades-old challenge

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

Radon Transform and Filtered Backprojection

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Scatter in an uncollimated x-ray CT machine based on a Geant4 Monte Carlo simulation. Wadeson, Nicola and Morton, Edward and Lionheart, William

Agenda : Lung Density Breakout Session

Improved Detector Response Characterization Method in ISOCS and LabSOCS

Scanner Parameter Estimation Using Bilevel Scans of Star Charts

RADIOLOGY AND DIAGNOSTIC IMAGING

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

Effects of the difference in tube voltage of the CT scanner on. dose calculation

Estimation of Missing Fan-Beam Projections using Frequency Consistency Conditions

FDK Half-Scan with a Heuristic Weighting Scheme on a Flat Panel Detector-Based Cone Beam CT (FDKHSCW)

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

Code of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³

Fits you like no other

Image Acquisition Systems

MEDICAL IMAGING 2nd Part Computed Tomography

Financial disclosure. Onboard imaging modality for IGRT

THE FAN-BEAM scan for rapid data acquisition has

Characterization of a Time-of-Flight PET Scanner based on Lanthanum Bromide

System Optimization and Patient Translational Motion Correction for Reduction of Artifacts in a Fan-Beam CT Scanner

Introduction to Positron Emission Tomography

Corso di laurea in Fisica A.A Fisica Medica 5 SPECT, PET

FAST KVP-SWITCHING DUAL ENERGY CT FOR PET ATTENUATION CORRECTION

Simplified statistical image reconstruction algorithm for polyenergetic X-ray CT. y i Poisson I i (E)e R } where, b i

Chapters 1 7: Overview

Polarization of Light

ratio of the volume under the 2D MTF of a lens to the volume under the 2D MTF of a diffraction limited

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Transcription:

Spectral analysis of non-stationary CT noise Kenneth M. Hanson Los Alamos Scientific Laboratory Int. Symposium and Course on Computed Tomography, Las Vegas, April 7-11, 1980 This presentation available at http://www.lanl.gov/home/kmh/ LA-UR-80-0323 April 9, 1980 CT Symposium and Course 1

NPS and NEQ For CT reconstructions, the noise power spectrum (NPS), or Wiener spectrum, is given by 2 π f H( f) S( f) = NEQ where f is radial spatial frequency H is the effective filter used in the reconstruction algorithm NEQ is the density of noise-equivalent quanta in the projection measurements If the NEQ is the same in all projection measurements, the NPS is stationary and isotropic However, if the density of detected quanta varies, the NPS is non-stationary and non-isotropic April 9, 1980 CT Symposium and Course 2

Geometry of CT projection measurement source detector source detector For the same incident x-ray fluence, the transmitted fluence is larger in the tangential direction (S' - D') than in the radial direction (S - D). Thus, one expects the noise at point P in the CT reconstruction to be anisotropic. April 9, 1980 CT Symposium and Course 3

Delta 2020 scan of uniform phantom Delta 2020 scan: 120 kvp, 200 mas. CT scan of 35.5-cm-diameter water-bath phantom, done on a Delta 2020 scanner without a dose compensation wedge. Note how noise streams outward near periphery, indicating that noise characteristics depend on direction. April 9, 1980 CT Symposium and Course 4

Standard NPS estimation 2D NPS for Delta 2020 displayed as a pseudograyscale image vs. horizontal and vertical spatial frequency. Zero frequency is in middle of image. 2D NPS obtained in standard manner appears to be isotropic. NPS goes to zero at zero frequency (middle of image), as expected. April 9, 1980 CT Symposium and Course 5

Standard NPS estimation Nyquist frequency = 0.64 mm -1 Radial frequency dependence of standard NPS, obtained by averaging 2D NPS over polar angles. NPS is roughly proportional to frequency at low frequencies. April 9, 1980 CT Symposium and Course 6

Radial-tangential NPS estimation Radial direction of power spectrum for each subsample is rotated to vertical before averaging. Method of estimating of radial and tangential components of NPS: The noise power spectra are calculated for subsamples of the original noisy image whose centers lie within an annulus. The power spectrum for each subsample is averaged after being rotated to align the radial frequency axes. April 9, 1980 CT Symposium and Course 7

Radial-tangential NPS Delta 2020 NPS displayed as a pseudo-grayscale image displayed in terms of the radial (vertical axis) and tangential frequency (horizontal axis). Zero frequency is in middle of plot. 2D NPS calculated for an average radius of 12.5 cm from the scan of a 35.5-cm-dia water phantom. Decomposed into radial and tangential components, NPS is highly nonisotropic. NPS lowest in radial direction, transverse to highest detected x-ray density. April 9, 1980 CT Symposium and Course 8

Radial-tangential NPS NPS analysis of a Delta 2020 scan of a 35.5-cm-dia water phantom Nyquist frequency = 0.64 mm -1 Radial-frequency dependence of NPS in radial and tangential directions, and midway between them, at average radius of 12.5 cm for Delta 2020 scan of a 35.5-cm-dia water phantom. April 9, 1980 CT Symposium and Course 9

Radial-tangential NPS NPS analysis of a Delta 2020 scan of a 35.5-cm-dia water phantom The average noise power above a frequency of 0.14 mm -1 plotted versus angle wrt. radial direction for various average radii. The curves have been drawn by eye. April 9, 1980 CT Symposium and Course 10

Radial-tangential NPS NPS analysis of a Delta 2020 scan of a 35.5-cm-dia water phantom Average noise power above 0.14 mm -1 in the tangential and radial frequency directions, as a function of average radius. Tangentially, the noise power remains constant, as expected. Radially, the dashed curve is based on the dependence of the fluence calculated for the phantom geometry. The solid curve is the same, with an added uniform background of 0.11. April 9, 1980 CT Symposium and Course 11

Delta 2020 In other studies, similar scans done on a Delta 2020 scanner with a dose compensation wedge show no significant noise anisotropy. April 9, 1980 CT Symposium and Course 12

GE 8800 scan of uniform phantom GE 8800 scan: 120 kvp, 456 mas Full scan mode; 576 views / 360º CT scan of 34-cm-diameter water-bath phantom, done on a GE 8800 scanner employing a dose compensation wedge. The noise appears to have approximately uniform characteristics everywhere and seems isotropic. April 9, 1980 CT Symposium and Course 13

GE 8800 third generation CT scanner GE 8800 is a third generation CT scanner rotating fan-beam geometry fan angle = α (approx. 34º) source and detector rotate around patient Two scanning modes: full scan rotation through 360º each pixel sees same ray coverage, i.e., 360º half-scan mode rotation through 180º + α additional rotation by α required so all pixels have at least 180º coverage but most pixels see more than 180º coverage the pathlengths for the redundant rays are typically averaged together, resulting in lower noise in certain directions expect to see this effect in 2D NPS April 9, 1980 CT Symposium and Course 14

Standard NPS estimation 2D NPS for GE 8800 in halfscan mode (342 views), displayed as a pseudograyscale image vs. horizontal and vertical spatial frequency. Zero frequency is in middle of image. For a half scan (180º + 34º), 2D NPS is nonisotropic; there is a dip in NPS along a radial line, about 20º from horizontal. April 9, 1980 CT Symposium and Course 15

Standard NPS estimation 2D NPS for GE 8800 in halfscan mode (342 views), displayed as a pseudograyscale image vs. horizontal and vertical spatial frequency. Zero frequency is in middle of image. For a subsequent half scan, the 2D NPS is also nonisotropic; there is a dip in NPS along a radial line, about 50º from horizontal. Note: GE 8800 starts scanning at an arbitrary angle. April 9, 1980 CT Symposium and Course 16

Standard NPS estimation 2D NPS for GE 8800 in fullscan mode (576 views), displayed as a pseudograyscale image vs. horizontal and vertical spatial frequency. Zero frequency is in middle of image. For a full scan (360º gantry rotation), the 2D NPS obtained in standard manner is isotropic. April 9, 1980 CT Symposium and Course 17

Summary Image noise in CT reconstructions depends on the density of detected x-rays in the projections Variable densities of detected x-rays implies the CT noise is nonstationary and non-isotropic even so, it is possible and useful to estimate the NPS, as a function position and direction in the image Analysis of the noise in reconstructions from a scanner without a compensation wedge (bowtie filter) demonstrates feasibility of decomposing NPS behavior into radial and tangential components explanation in terms of the density of detected x-rays (NEQ) NPS of half-scan images from a third-generation scanner (GE8800) with compensation shows non-isotropic noise because of ray averaging April 9, 1980 CT Symposium and Course 18

Bibliography Noise due to photon counting statistics in computed X-ray tomography, D. A. Chesler, S. J. Riederer, and N. J. Pelc, J. Comput. Assist. Tomogr. 1, pp. 64-74 (1977) Detectability in computed tomography images," K. M. Hanson, Phys. Med. Biol. 6, pp. 441-451 (1979) "Noise and contrast discrimination in CT," K. M. Hanson, in Radiology of the Skull and Brain, Vol. V: Technical Aspects of Computed Tomography, T. H. Newton and D. G. Potts, eds., pp. 3941-3955 (C. V. Mosby, New York, 1981) This presentation available at http://www.lanl.gov/home/kmh/ April 9, 1980 CT Symposium and Course 19