Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Similar documents
Bulletin 294 ArmorStart LT Distributed Motor Controllers Feature Diagram

Bulletin 280E/281E, 284E ArmorStart Distributed Motor Controller Product Overview

TM241CE24U controller M IO transistor NPN Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40R controller M IO relay Ethernet

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE40T controller M IO transistor PNP Ethernet

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet

TM241C40U controller M IO transistor NPN

TM241CEC24R controller M IO relay Ethernet CAN master

TM241C24T controller M IO transistor PNP

TM241CE24T controller M IO transistor PNP Ethernet

TM241C40R controller M IO relay

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

TM221CE40R controller M IO relay Ethernet

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

TM241CE40R controller M IO relay Ethernet

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

TM221CE40R controller M IO relay Ethernet

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

em4 Accessories Digital expansions

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

TM221CE24R controller M IO relay Ethernet

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

TM221ME16T controller M IO transistor PNP Ethernet

TeSys IEC Contactors and Overload Relays

TM221CE40T controller M IO transistor PNP Ethernet

TM221ME32TK controller M IO transistor PNP Ethernet

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

TM221CE24T controller M IO transistor PNP Ethernet

Model Number Structure

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV71QC16N4 variable speed drive ATV71Q - 160kW / 250HP V - IP20

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

TM221ME16T controller M IO transistor PNP Ethernet

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

DC561, digital input/output module,

DC562, digital input/output module,

ATV32H075M2 variable speed drive ATV32-0,75 kw V - 1 phase - with heat sink

ATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet

CompactBlock Guard I/O EtherNet/IP Safety Modules

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

TM3DI16 module TM3-16 inputs

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ATV61HU55M3 ATV61 5,5 kw 7,5HP 240V single phase EMC IP20

Contact protection relay

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

TM251MESC controller M251 Ethernet CAN

TM221ME16RG. Main. Discrete output number. Discrete input current

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

ATV61QC31N4 variable speed drive ATV61Q - 315kW / 500HP V - IP20

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV630D11N4 variable speed drive ATV630-11kW/15HP V - IP21/UL type 1

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

TM221M32TK controller M IO transistor PNP

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

TM221M16R controller M IO relay

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

TeSys protection components

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

TM221CE24T. Main. Discrete output logic. Discrete input current. <= 7 relay output

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

Transcription:

Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals Motor Power Terminals PE (Earth Ground) Terminal Maximum Rated Operating Rated Impulsed (U imp ) Dielectric Withstand L1, L2, L3 T1, T2, T3 4 PE terminals 400Y/230 480Y/277 (-15%, +10%) 4 kv UL: 1960V AC, IEC: 2500V AC Operating Frequency 50/60 Hz (±10%) Maximum Rated Operating Current Cat. No. Hp (kw) Overload Range 290_- -A-* 291_- -A-* 290_- -B-* 291_- -B-* 3 (1.5) 0.25 3.5 A 5 (4) 1.1 7.6 A Overload Type Solid-state I 2 T Trip Class [10], 15, 20 with thermal memory retention (see Motor Overload Trip Curves) Trip Rating Full Load Current (FLC)) 120% of FLC Reset Mode Automatic or manual Overload Reset Level 1 100% TCU Overvoltage Category III Power Supply NEC Class 2 Rated Operating 24V DC (+10%, -20%) Overvoltage Protection Reverse-polarity protected Nominal Current 150 ma Unswitched Power Supply Requirements Switched Power Supply Requirements Switched and Unswitched Power Supply Requirements Power Input Current (each) Maximum Current Maximum Power Peak Inrush Nominal Current Power Output Current (each) Maximum Current Maximum Power Peak Inrush Nominal Current Power Number of Inputs (x 50 ma) Number of Outputs (x 500 ma) Maximum Current Maximum Power Peak Inrush 3.6 W 50 ma 450 ma 11 W <5 A for 35 ms 125 ma 3 W 500 ma 1.625 A 11 W <5 A for 35 ms 275 ma 6.6 W user defined user defined 275 ma + user defined 6.6 W + (24V DC x user defined) <10 A for 35 ms An internal 60 W isolated flyback power converter sources input, outputs, and main control board with 24V DC power. Cat. No. Sym. Amps RMS Circuit Breaker Fuse 290/1_-* 10 ka @ 480Y/277 When used with Allen-Bradley Cat. No. 140U-D6D3-C30 CC, J, or T fuse (maximum 45 A) 290/1_-* 5 ka @ 480Y/277 UL Class RK5 fuse Short Circuit Coordination Type 1 Size per NFPA 70 (NEC) or NFPA 79 for Group Motor Applications I/O is configurable to either input or output. Assumes zero wire resistance. Wire impedance will reduce current inrush. 10 Publication 290-SG001A-EN-P

Input Output Supply Type of Inputs Connection Type Input per Connection Rated Operating On-State Input (pin 4) Off-State Input On-State Input Current (pin 4) Off-State Input Current Input and Output Ratings Maximum Sensor Leakage Current Unswitched power A3/A2 24V DC current sinking Single keyed M12, quick disconnect 1/each 24V DC 10 26.4V DC, nominal 24V DC 5V DC 1 3.7 ma, 2.6 ma @ 24V DC <1.5 ma <2.5 ma Maximum Number of Input Devices 6 Maximum Sensor Sourcing Current (pin 1) Sensor Operating Range Input Bounce Filter (Software Configurable) Filtering DeviceLogix I/O Response Supply (Switched Power) Type of Outputs Load Types Utilization Category (IEC) Output State Connection Type Output per Connection Overcurrent Protection Rated Insulation (U i ) Rated Operating (U e ) Maximum Blocking Nominal Operating Current (I e ) Maximum Thermal Current (I the ) Maximum Off-state Leakage Current 50 ma per point (maximum 300 ma total for sourcing one device) 19.2 26V DC Off-On or On-Off: 0.5 ms + 64 ms 100 μs 2 ms (500 Hz) A1/A2 DC sourcing Resistive or light inductive DC-1, DC-13 Normally Open (N.O.) Single keyed M12, quick disconnect 1/each 1.5 A (the sum of all outputs can not exceed this value) UL: 1500V AC, IEC: 2000V AC 35V DC 500 ma per point 500 ma per point Maximum Number of Outputs 6 Surge Suppression Input ON-to-OFF delay time is the time from a valid input signal to recognition by the module. If an output exceeds 1.5 A for greater than 7 ms, a fault is generated. 1 μa Integrated diode to protect against switching loads Operating Temperature Range Storage and Transportation Temperature Range Altitude Humidity Environmental Ratings -20 +50 C (-4 +122 F) 25...+85 C ( 13 +185 F) 2000 m 5 95% (non-condensing) Pollution Degree 3 Enclosure Ratings IP66/UL Type 4/12 Approximate Shipping Weight 4.6 kg (10 lb) Publication 290-SG001A-EN-P 11

Resistance to Shock Resistance to Vibration Disconnect Lock Out Disconnect LOTO Locks Disconnect Mechanical Life Contactor Utilization Category (IEC) Contactor Opening Delay Contactor Closing Delay Minimum Off Time Contactor Mechanical Life Wire Size Wire Type Mechanical Ratings Operational 30 G, exceeds IEC 60947-1 Non-Operational 50 G, exceeds IEC 60947-1 Operational 2.5 G, tested to MIL-STD-810G, exceeds IEC 60947-1 Non-Operational 5 G, tested to MIL-STD-810G, exceeds IEC 60947-1 Maximum of 3/8 in. (9.5 mm) diameter lock shackle or hasp Up to 2 locks or hasps are supported 200 000 operations AC-1, AC-3, AC-4 (refer to Life Load Curves) 8 12 ms 18 40 ms 200 ms 15 million operations Power Terminals Motor Terminals Control Terminals PE/Ground (2) #18 #10 AWG (0.8 5.2 mm2) per terminal (2) #18 #10 AWG (0.8 5.2 mm2) per terminal Multi-strand/solid copper wire (2) #18 #10 AWG (0.8 5.2 mm2) per terminal (2) #16 #10 AWG (1.3 5.2 mm2) per terminal Tightening Torque 10.6 ± 2 lb in (1.2 ± 0.2 N m ) 18 ± 2 lb in (2 ± 0.2 N m ) Wire Strip Length 0.35 ± 0.01 in. (9 ± 2 mm) Power Rating 600V AC/25 Amp VAC 600V AC/10 Amp VAC 600V AC/10 Amp VAC Emission Immunity Emission and Immunity Ratings Conducted EN 60947-4-1 Radiated Class A Electrostatic Discharge Radio Frequency Electromagnetic Field Fast Transient Surge Transient Radio Frequency Conducted Disturbance 4 kv contact, 8 kv air EN 60947-4-1 10V/m, 80 MHz 1 GHz 10V/m, 1.4 GHz 2 GHz 2 kv (Power) 2 kv (PE) 1 kv (Communication and control) 1 kv (12) L-L, 2 kv (2) L-N (earth) 10V, 150 khz 80 MHz Standards Compliance Certifications Standards Compliance and Certifications UL/CSA EN/IEC Other Agencies UL 508 Industrial Control Equipment Suitable for Group Installation CSA C22.2, No. 14 EN 60947-4-1 Low Switchgear CE Marked per Low Directive 2006/95/EC and EMC Directive 2004/108/EC culus (File No. E3125, Guide NLDX, NLDX7) CCC (Pending) C-Tick (Pending) ODVA for EtherNet/IP 12 Publication 290-SG001A-EN-P

EtherNet/IP Web Server Network Connections Rated Insulation Operating Dielectric Withstand Communication Ratings 250V UL/NEMA: 1500V AC, IEC: 2000V AC EtherNet/IP ODVA - Conformance Testing EtherNet/IP Interoperability Performance Per A9 PF 2.1 Ethernet Communication Rate Ethernet Ports Ethernet Network Topologies Supported Device Level Ring Support Ethernet Connector Ethernet Cable IP Configuration DHCP Timeout Data Packet Rate (pps) 10/100 Mbps, half or full-duplex 2 (embedded switch) Star, Tree, Linear, and Ring Beacon Performance, IEEE 1588 Transparent Clock M12, D code, female, with Ethernet keying, 4 Pin Category 5e: Shielded or unshielded Static, DHCP, or BootP 30 s Transported over both TCP and UDP 500 packets-per-second (2000 μs), Tx 500 packets-per-second (2000 μs), Rx Consume Instance (Command) Default of 3 words (Instance 150) Produce Instance (Status) Default of 14 words (Instance 152) Message Support Address Conflict Detection (ACD) Sockets Security E-mail Webpage Features Unicast or Multicast IP v4 Address Conflict Detection for EtherNet/IP devices 150 maximum Login and password configurable Support Simple Mail Transfer Protocol (SMTP) Status, diagnostics, configuration Concurrent Sessions 20 Web Server HTTP 1.1 Concurrent TCP Connections Maximum I/O Connections (CIP Class 1) Maximum of 15 encapsulated messages over both TCP and UDP Supports up to 2 Class 1 CIP connections (Exclusive owner (data) or listen-only). One connection per PLC. Listen-only connection requires a data connection to be established. Maximum Concurrent Explicit Messages (CIP Class 3) 6 Class 1 Connection API Class 3 Connection API Request Packet Interval (RPI) 2 3200 ms 100 10 000 ms 20 ms default (2 ms minimum) Publication 290-SG001A-EN-P 13

Motor Overload Trip Curves Class 10 Approximate Trip Time [s] Hot Cold % Full Load Current Class 15 Approximate Trip Time [s] Hot Cold % Full Load Current Class 20 Approximate Trip Time [s] Hot Cold % Full Load Current 14 Publication 290-SG001A-EN-P

Bulletin 100-K/104-K Life-Load Curves Electrical life; Ue = 400 460V AC AC-3 : Switching of squirrel-cage motors while starting 10 Contact Life (millions of operations) 1 0.1 100-K09 (Used with ArmorStart LT) 0.01 1 10 100 Rated Current Ie AC-3 [A] Electrical life; Ue = 400 460V AC AC-4 : Stepping of squirrel-cage motors 10 (Used with ArmorStart LT) 100-K09 Contact Life (millions of operations) 1 0.1 0.01 0.1 1 10 Rated Current Ie AC-4 [A] Publication 290-SG001A-EN-P 15