TETRIS 2500 High Impedance Active Probe. Instruction Manual

Similar documents
PML 791-RO Low-Z Passive Probe. Instruction Manual

TETRIS 1000 / High Impedance Active Probe Order-No: Features:

PMT 201A-RO High Impedance Passive Probe. Instruction Manual

PMT 221A High Impedance Passive Probe. Instruction Manual

designed for OMICRON Lab PML 111O High Impedance Passive Probe Instruction Manual

38 MHz Passive Voltage Probe R&S RT-ZP1X

KHT 6000 C HV-Probe Calibrator. Instruction Manual

TA MHz Oscilloscope Probe USER S GUIDE

LeCroy PP009 Passive Probe Instruction Manual

LeCroy PP008 Passive Probe Instruction Manual

Instruction Manual LeCroy PP007-WR / PP007-WS Passive Probe

PP007-WR-1 PP007-WR-2 PP007-WS-1 PP007-WS-2. Operator s Manual. PP007 Passive Probe

Instructions. P MHz 10X Passive Probe

Instructions. P GHz 10X Active Probe

TCP305A & TCP312A AC/DC Current Probes Instructions

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

P5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD

P344 4-lane MIPI DPhy Stimulus Generator Data Sheet & User Manual. January Rev 1.31

custom test and measuring environments.

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

User's Guide. Extech AM A AC Analog Clamp Meter

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

DC 100 A Current Probe

Mini Digital Multimeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

MTP INSTRUCTION MANUAL

1103 Power Supply (SN B and Above) Instruction Manual

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

DC 100 A Current Probe

N2870A Series Passive Probes and Accessories

N2870A Series Passive Probes and Accessories

Accessory GP-EXT. EXTERNAL USB PRINTER User's Manual

Automated Tuner System Power Distribution Hub

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

CAEN. Electronic Instrumentation. NIM slot 5U CERN Compliant NIM Crate. Rev July Tools for Discovery

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

SCC-AO10 Isolated Analog Output Module

User s Manual Model PBL250 Logic Probe IM E. 3rd Edition

User s Guide. 600A AC Clamp Meter. Model 38387

Operating Instructions PRO-AB /6.15. Leakage Current Measuring Adapter

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Quick Start/Installation Guide

Keysight N2870A Series Passive Probes and Accessories. Data Sheet

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

User's Guide. Phase Sequence and Motor Rotation Tester Model

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

PicoScope 9000 Series PC Sampling Oscilloscopes. Quick Start Guide

DVI Extender over Fiber with EMI Shielding

RSA306 Real-Time Spectrum Analyzer Installation and Safety Instructions

9040/9040UK. Users Manual. Phase Rotation Indicator

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

PRODUCT SPECIFICATION. PC Board Relays. Series.

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

±15 V Current-Limited Power Supply

Visit us at

Model Number Structure

POCKET MULTIMETER 5115 ENGLISH User Manual

UTAH-100/XHDA SERIES

TSD-DA28 2x8 Balanced Line Distribution Amplifier

ETHOS Auto Ranging Digital Multimeter

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

HV-CS kv Edge Mount Triaxial Jack

DVI Extender over single LC Fiber with TMDS video and EDID data.

NI PXI-2567 Specifications

SATA II HDD Canister KISS DA 435 Quick Reference Guide

80W (16V/5A) Power Supply with USB Output. User Manual

S82S (3/7.5-W Models)

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

DVI Extender over Single CAT5 Mini SET

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

RSA306B Real-Time Spectrum Analyzer Installation and Safety Instructions

NI What You Need to Get Started. Unpacking INSTALLATION GUIDE. This document explains how to set up your NI 8262 expansion module.

SCC-RLY01 Relay Module

Model SPDT Switch Module

You need the following to set up and use your terminal block:

Agilent 16442B. User s Guide. Agilent Technologies

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

NX8 Pocket Toner Users Guide

Model Number Structure

Agilent U2941A Parametric Test Fixture

Operating instructions LSR-3000

WAXPENCIL PRO Owner & Operator s Manual

USB3740. High Speed Switch for Mobile and Portable Applications USB3740 PRODUCT FEATURES DATASHEET. USB3740 Block Diagram

2 Port DVI Splitter. Model #: SPLIT-DVI

Model Channel TTL I/O

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

MDM 011-Z1 Regen Resistor

TVAC25100 TVAC25110 User manual

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Line Impedance Stabilization Network (LISN)

SLA Battery Capacity Analyzer

CerePlex A. Instructions for Use. 630 Komas Drive Suite 200. Salt Lake City UT USA P F

Transcription:

TETRIS 2500 High Impedance Active Probe Instruction Manual

Copyright 2018 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications are subject to change without notice. Manufacturer PMK Mess- und Kommunikationstechnik GmbH Königsteiner Str. 98 65812 Bad Soden, Germany Internet: www.pmk.de Tel: +49 (0) 6196 5927-930 E-mail: sales@pmk.de Fax: +49 (0) 6196 5927-939 Warranty PMK GmbH warrants this oscilloscope accessory for normal use and operation within specifications for a period of two (2) years from date of shipment and will repair or replace any defective product which was not damaged by negligence, misuse, improper installation, accident or unauthorized repair or modification by the buyer. This warranty is applicable only to defects due to material or workmanship. PMK GmbH disclaim any other implied warranties of merchantability or fitness for a particular purpose. PMK GmbH will not be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if PMK GmbH has been advised of the possibility of such damages arising from any defect or error in this manual or product. 2

Declaration of Conformity TETRIS 2500 (EC conformity marking) The manufacturer declares,that this product is designed and manufactured in accordance with the requirements of the specified Directives and Standards as listed below. The product carries the CE mark. EU Directives covered by this declaration: 2004/108/EC Electromagnetic Compatibility Directive 2006/95/EC Low Voltage Equipment Directive 2002/96/EC Waste Electrical and Electronic Equipment 2002/95/EC Restriction of use of certain Hazardous Substances and its revised version 2011/65/EU The basis on which conformity is being declared: EN61010-1:2010 Safety requirements for electrical equipment for measurement, control and laboratory use, general equipment requirements EN61010-031:2002 + A1:2008 Safety requirements for hand-held probe assemblies for electrical measurement and test EN61326-1:2006 Electrical equipment for measurement, control and laboratory use EMC requirements. Basic Immunity - static discharge per EN61000-4-2 RoHS and WEEE Statements and Confirmations issued by our vendors that no hazardous or restricted substances are used to manufacture components, parts and subassemblies for our products. TETRIS Power Supplies Models PS-01 and PS-01-INT (International version with exchangeable mains adapters) are manufactured in Germany by Friwo Gerätebau GmbH. The power supplies are not included in the scope of this declaration of conformity. Upon request we are able to provide full information about conformity and certifications of the power supplies made by Friwo and supplied with our TETRIS probes. WEEE/ RoHS Directives (EC conformity marking) Your help and efforts are required to protect and keep clean our environment. Therefore return this electronic product at the end of its life either to the Service Department of PMK Mess- und Kommunikationstechnik GmbH or take care of separate WEEE collection and professional WEEE treatment yourself. Do not dispose as unsorted municipal waste. * EC Directives: WEEE Directive 2002/96/EC - Waste Electrical and Electronic Equipment RoHS Directive 2002/95/EC - Restriction of the use of certain Hazardous Substances in Electrical and Electronic Equipment 3

Safety Symbols TETRIS 2500 The following symbols may appear on the product or in this instruction manual: Caution, risk of danger. Refer to manual. Caution, risk of electric shock. Earth (ground) TERMINAL. 4

Safety Information TETRIS 2500 To avoid personal injury and to prevent fire or damage to this product or products connected to it, review and comply with the following safety precautions. Be aware that if you use this probe assembly in a manner not specified the protection this product provides may be impaired. Only qualified personnel should use this probe assembly. Use only grounded instruments. Do not connect the probe ground lead to a potential other than earth ground. Always make sure the probe and the measurement instrument are grounded properly. Connect and disconnect properly. Connect the probe output to the measurement instrument and connect the ground lead to earth ground before connecting the probe to the circuit under test. Disconnect the probe input and the probe ground lead from the circuit under test before disconnecting the probe from the measurement instrument. Observe probe ratings. Do not apply any electrical potential to the probe input which exceeds the maximum ratings of the probe. Keep away from live circuits. Avoid open circuitry. Do not touch connections or components when power is present. Do not operate with suspected failures. Refer to qualified service personnel. Indoor use only. Do not operate in wet/damp environment. Keep product surfaces dry and clean. Do not operate the product in an explosive atmosphere. 5

About the Tetris Active Probe System TETRIS 2500 PMK presents a unique Inline Probing System the TETRIS active probe which can contact adjacent square pins in 2.54 mm pitch simultaneously. The probe s housing is T-shaped so that many probes can be positioned next to each other in a never ending chain. Like this a number of measurements can be performed at the same time. The TETRIS is system-independant and its standard SMA connector can be plugged onto any measuring instrument with a 50 Ω input. With an input resistance of 1 MΩ and an input capacitance of 0.9 pf the TETRIS probe is suitable for measurements in all frequency ranges. Compared to passive probes the TETRIS active probe offers a high input impedance into the GHz-range. Passive probes with their relative high input capacitance load the signal source already at frequencies above 100 khz. That s why the TETRIS active probe with its high input resistance and its low input capacitance is the ideal probe for most of your daily measurments. TETRIS 2500 testing adjacent pins in 2.54 mm Pitch 6

Operating Basics TETRIS 2500 When using this active probe device make sure the measuring instrument is set to 50 Ω input coupling and the probe is connected to the power supply. Handling Note that the probe cable is a sensitive part of the probe. Do not damage through excessive bending or pulling. Avoid mechanical shock to this product in general to guarantee accurate performance and protection. Power Supply Double Voltage Single Voltage Inner Connector +12 V 24 V Inner Shielding -12 V 0 V Outer Shielding Earth-Ground Open (floating) Required Current Connector Type 150mA Triaxial Lemosa Connector Please note, that any noise of the supply voltage influences the noise of the signal in general. Maintenance Cleaning To clean the exterior of the probe use a soft cloth moistened with either distillated water or isopropyl alcohol. Before use allow the probe to dry completely. 7

Specifications TETRIS 2500 Specifications that are not defined to be guaranteed are typical and published as general information to the user. The instrument should have warmed-up for at least 20 minutes and the environmental conditions should not exceed the probe's specified limits. Electrical Specifications Attenuation Ratio 10:1 ± 0.5 % at DC Dynamic Measuring Range ± 8 V System Bandwidth (1) 2 GHz (-3 db) Bandwidth (Probe only) 2.5 GHz Maximum Rated Input Voltage 20 V Max. Input Voltage and Dynamic Measuring Range The TETRIS active probe is protected against electro-static-discharge voltage (ESD). However, applying input-voltages outside the specified limits can result in destruction of the probe s amplifier. The maximum amplitude of the applied signal may not exceed the limits of the graph below, to avoid input linearity errors and damage to the probe The maximum amplitude of the applied signal may not exceed the limits of the graph below, to avoid damage to the probe. 100 Input Voltage vs. Frequency TETRIS 2500 Voltage [V] AC peak 10 1 1M 10M 100M 1G 10G Frequency [Hz] Dynamic Measuring Range Maximum Input Voltage To avoid input linearity errors and damage to the probe feel free to contact our customer support under sales@pmk.de for questions regarding the maximum input range or dynamic measuring range. (1) connected to oscilloscope >2.0 GHz 8

Specifications TETRIS 2500 Electrical Characteristics Input Resistance (System) Input Capacitance (System) Oscilloscope Input Coupling > 1 MΩ 0.9 pf 50 Ω AC / DC Input Impedance Note that the input impedance of the probe decreases as the frequency of the applied signal increases. For further information on the matter contact our support under sales@pmk.de. Mechanical Characteristics Weight (probe only) Cable Length 96 g 1.3 m Environmental specifications Altitude operating up to 2000 m non-operating up to 15000 m Temperature Range operating 0 C to +45 C non-operating -40 C to +71 C Maximum Relative Humidity operating 80 % relative humidity for temperatures up to +31 C, decreasing linearly to 40 % at +45 C 9

Accessories TETRIS 2500 890-700-108 Set 10 PCB Adapters 890-700-258 Set 25 PCB Adapters 890-400-800 Z - Ground 018-291-103 Ground Blade 018-291-105 Ground Leaf 890-100-150 10 self-adhesive Cu Pads ( 2 x 2 cm ) DEVICE UNDER TEST 890-800-001 Set 5 Spring Tips 890-800-000 Set 5 Solid Tips 890-500-801 L - In Adapter 890-502-130 QFP IC-Clip 13 mm long down to 0.5 mm pitch ( 1 pair, yellow/green ) 890-720-800 Y-Lead Adapter to 0.8 mm sockets 10 cm 890-502-000 QFP IC-Clip short down to 0.5 mm pitch ( 1 pair, yellow/green ) 890-720-816 Y-Lead Adapter to open Leads 6 cm P25-2 Pico hook red 890-720-813 Y-Lead Adapter to open Leads 3 cm P25-0 Pico hook black 10

Accessories TETRIS 2500 890-020-916 Marker Bands 4 Colors 890-400-801 Ground Lead 6 cm 890-400-802 Ground Lead 12 cm 890-400-803 Ground Lead 90 5 cm 890-400-804 Ground Lead 90 10 cm 11

Scope of Delivery TETRIS 2500 The following items are included in the scope of delivery. Please check the delivery for completeness. If any item is missing, send a message to our service department and we will send you this item immediately. Item Qty Ground Blade 1 Ground Lead 6 cm 1 Ground Lead 12 cm 1 Ground Lead 90 5 cm 1 Ground Lead 90 10 cm 1 Ground Leaf 1 Instruction Manual 1 L-In Adapter 1 Marker Bands 4 colors 1 PCB Adapter 1 Picohook TM black 1 Picohook TM red 1 Power Supply 1 Probe 1 self adhesive Cu Pad (2 x 2 cm) 2 Solid Tip 1 Spring Tip 1 Y-Lead Adapter to 0.8 mm sockets 1 Z-Ground 1 Use ground lead only for connections to earth ground. The accessories provided with the probe have been safety tested. Do not use any other accessories than those originally provided. M-TETRIS2500 Revision I - Jan 2018