Flexoled FTP3HP RGB LED DMX Driver

Similar documents
FTP1 Single Channel LED DMX Driver

CS2 DMX Distribution Splitter

Microbar COB System. User Manual. Order code: EQLED137

UV Power Flood. User Manual. Order code: EQLED029

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

Crossfire. User Manual. Order code: EQLED061

RGB Power Batten. User Manual. Order code: EQLED032

Blitzer Strobe. User Manual. Order code: EQLED366

CDP 405 Digital Dimmer Pack

Blitzer RGB Strobe. User Manual. Order code: EQLED365

PF LED Profile. User Manual

ZF LED Zoom Fresnel. User Manual

DMX LED Starcloth Systems

EasiLED 4 DMX Controller

Gobo Projector XP 80W

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

Slimline CW & WW Series

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Performer 18 RGBWA MKII

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

Fusion Saber. User Manual. Order code: EQLED070

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

MICRON DJ Booth Tri-colour Starcloth

UV Spectra Batten 12 x 5W UV LEDs

Starlit Dance Floor. User Manual

LIGHT BRICK - 12 X 3W TRI-COLOUR

Vector Beam White. User Manual. Order code: LEDJ265

Microbar Multi System

Vortex. User Manual. Order code: EQLED073

MICRON DJ Booth System with Overhead Kit & CW Starcloth

w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

w w w. p r o l i g h t. c o. u k STAGE PAR 64

Saturn Spot. User Manual. Order code: EQLED023

Hypnos. User Manual. Order code: EQLED372

Endura 1Q120 RGBW COB Exterior Fixture

IMPACT Order code: EQLED79

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

order code: EQLED40 user manual

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

CPA 40 Two Channel Amplifier

Intense 9P10 RGBWA LED Slim Par

Slimline 12Q5 Series

Order code: EQLED60 USER MANUAL

Colour Burst Order code: LEDJ01 USER MANUAL

Professional DMX Stage Backdrop

Fresco 24 RGBW. Exterior Fixture User Manual. Order code: LEDJ267

Intense 9HEX10 LED Slim Par

TRANSCENSION Show Control

BGS 20T 100V/8Ω Background Music Loudspeakers

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Order code: EQLED53 User manual

Party Dimmer IEC ORDERCODE 50324

Multidim ORDERCODE 50391

Octostrip ORDERCODE 42220

D-Pack 6 Classic ORDERCODE 50315

Light Brick ORDERCODE 50370

LED Par 64 Short DMX ORDERCODE 42431

Antenna Distributor ORDERCODE D1444

LED PAR56 Order Code: P56-151

Network Camera. Quick Guide DC-B1203X. Powered by

DC-D4213RX DC-D4213WRX

1 Channel Strobe Controller ORDERCODE 40226

Heavy Duty DMX Mirror Ball Rotator with Safety Eye

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

DC-V3213XJ-4.3mm DC-V3213XJ-2.5mm

Colour Star Sky I DMX ORDERCODE 40341

DC-D2212R / DC-D2212WR

DPX-620III 6-Ch. dimmer pack. user manual

LED Pixel Rail Drive 640 controller. user manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

Network Camera. Quick Guide DC-T3243HRX. Powered by

Network Camera. Quick Guide DC-D1223WX. Powered by

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

LED Dancefloor ORDERCODE 42300

UP-1-1 Channel Dimmer. User manual. dimmer pack

Check that the unit has not been damaged during transport

UP-1-1 Channel Dimmer dimmer pack. user manual

xbrick Full-Colour 16 3W LED floodlight user manual

D1210H dimmer pack. user manual

LED Powerbar 24 ORDERCODE 41331

1 Channel Sliding Profile Dimmer ORDERCODE 50425

Large Police Light 100W ORDERCODE 80361

ENGLISH Flexstrip Set RGB

LED Giga Bar 4. User Manual

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

Warning... Safety-instructions Operating Determinations Rigging... Description... Features and Overview...

HX1 Bluetooth Stereo Headset

LED Commander 16/2 DMX controller. user manual

Promopar ORDERCODE 30120

Network Camera. Quick Guide DC-S1283WRX. Powered by

order code: EQLA04 user manual

TA18 active subwoofer. user manual

DMX Splitter 4 MKIII 19" DMX splitter. user manual

DS-2 RF DMX dimmer. user manual

ENGLISH Flexstrip Set IP44 RGB

LED Colour Flood 10W / 30W RGB LED floodlight. user manual

Showdesigner 512 ORDERCODE 50721

DDS 405 digital dimmer and switcher. user manual

Version 1.0 March 2014 OLC 10.1

Pixel Panel 144 RGB effect panel. user manual

Transcription:

Flexoled FTP3HP RGB LED DMX Driver User Manual + 12-24V DMX INPUT DMX OUTPUT DC IN (12A MAX) DMX ADDRESS & DIMMER SETTINGS SWITCH 10 11 12 DMX MODE DIMMING MODE BUILT-IN MODE LOAD 4A PER CHANNEL (12A MAX) OUTPUT BLUE GREEN RED Order code: FLEX30

Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make sure that there is no damage caused during transportation. Should there be any damage, consult your dealer and do not use the equipment. To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual. Please note that damages caused by user modifications to this equipment are not subject to warranty. CAUTION! KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS CAUTION! TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!! IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment. This product is designed to be installed by a competent, qualified installation technician into commercial environments. Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution! Never remove warning or informative labels from the unit. Do not open the equipment and do not modify the unit. Do not connect this equipment to a dimmer pack. Do not switch the equipment on and off in short intervals, as this will reduce the system s life. Only use the equipment indoors. Do not expose to flammable sources, liquids or gases. Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable. Make sure that the available voltage is between 12-24V DC. Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g: short-circuit, burns and electric shocks etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and/or property. If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again. If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature. If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service. Only use fuses of same type and rating. Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. This lighting fixture is for professional use only - it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls. WARRANTY: One year from date of purchase. www.prolight.co.uk FTP3HP RGB LED DMX Driver User Manual 2

Product overview & technical specifications FTP3HP RGB LED DMX Driver The FTP3HP RGB LED DMX Driver is suitable for most types of 12-24V RGB flexible colour strips requiring constant voltage control. After connecting a RGB LED Strip(s) with this RGB controller you can utilise the manual dimming mode or built-in programs via the on-board dipswitches. Further control can be facilitated by the units DMX input. The driver can also be used for 3 channels of single colour LED tape. + 12-24V DMX INPUT DMX OUTPUT DC IN (12A MAX) DMX ADDRESS & DIMMER SETTINGS SWITCH 10 11 12 DMX MODE DIMMING MODE BUILT-IN MODE 115mm LOAD 4A PER CHANNEL (12A MAX) OUTPUT BLUE GREEN RED 24.5mm Constant voltage driver for 12-24V RGB LED flexible colour strip Housed in a compact, rugged metal casing Phoenix type plug in terminals DMX and manual dimming mode plus built-in programs Dipswitch mode/dmx selection 54mm Specifications FTP3HP RGB LED DMX Driver 04 Power supply DC 12-24V Maximum total output Dimensions Weight IP rating Order code 12A 24.5 x 115 x 54mm 0.2kg IP20 FLEX30 In the box: 1 x unit & 1 x user manual 01 02 03 + 12-24V DMX INPUT DMX OUTPUT DC IN (12A MAX) DMX ADDRESS & DIMMER SETTINGS SWITCH 10 11 12 DMX MODE DIMMING MODE BUILT-IN MODE LOAD 4A PER CHANNEL (12A MAX) OUTPUT BLUE GREEN RED 07 05 06 07 DMX mode: 01-3-Pin DMX input terminal 02-3-Pin DMX output terminal 03-2-Pin power in terminal 04 - Dipswitches 05 - RGB output terminals 06 - +VE output common terminals 07 - Mounting points In DMX mode, dipswitch 10 should be in the ON position. The DMX address is set by combining dipswitches (0-9) that add up to the value required between 001-511. Please refer to the table below for more information. Dipswitch Value 1 1 2 2 3 4 4 8 5 16 6 32 7 64 8 128 9 256 1 2 3 4 5 6 7 8 9 10 11 12 DMX address examples: 1 = ON 0 = OFF To set the DMX address to 021 ; Switch dipswitches 1, 3 and 5 in the ON position. 1 = 1 3 = 4 5 = 16 = 21 To set the DMX address to 451 ; Switch dipswitches 1, 2, 7, 8 and 9 in the ON position. 1 = 1 2 = 2 7 = 64 8 = 128 9 = 256 = 451 www.prolight.co.uk FTP3HP RGB LED DMX Driver User Manual 3

Operating instructions 3 channel mode: Channel Value Function 1 000-255 Dimmer 1 (Red) (0-100%) 2 000-255 Dimmer 2 (Green) (0-100%) 3 000-255 Dimmer 3 (Blue) (0-100%) Manual dimming/static colour selection mode: In manual dimming mode, dipswitch 11 should be in the ON position. Dipswitches 1-3 should be now used to control the intensity of the Red LEDs, 4-6 for the Green LEDs and 7-9 for the Blue LEDs. Please refer to the table below for more information. Dipswitch setting: Intensity CH1 Red (1-3) CH2 Green (4-6) CH3 Blue (7-9) 0% 000 000 000 14% 100 100 100 28% 010 010 010 43% 110 110 110 57% 001 001 001 71% 101 101 101 86% 011 011 011 100% 111 111 111 1 2 3 4 5 6 7 8 9 10 11 12 Red Green Blue 1 = ON 0 = OFF Built-in programs mode: In built-in programs mode, dipswitch 12 should be in the ON position. Dipswitches 1-3 should be now used to control the Fade, 4-6 to set the Speed and 7-9 to set the program. Please refer to the table below for more information. Dipswitch setting: Dipswitch Fade time (1-3) Speed (4-6) Program (7-9) 000 0% 128s 1 100 14% 64s 2 010 28% 32s 3 110 43% 16s 4 001 57% 8s 5 101 71% 4s 6 011 86% 2s 7 111 100% 1s Auto (runs through programs 1-7) 1 2 3 4 5 6 7 8 9 10 11 12 Fade Speed Program 1 = ON 0 = OFF www.prolight.co.uk FTP3HP RGB LED DMX Driver User Manual 4

Example configuration DMX Controller DMX OUT DMX IN 12/24V DC Power supply Power IN 230V AC 12/24V DC LED tape (Parallel) R G B + R G B + R G B + R G B + Please note: The feed cable between the controller and the LED tape must be kept as short as possible. Using a large diameter cable will prevent voltage drop issues over longer distances. Wiring in parallel with feed cables to both ends of the LED tape will prevent colour fades across the length of the tape. www.prolight.co.uk FTP3HP RGB LED DMX Driver User Manual 5

Example configuration DMX Controller DMX OUT DMX IN DMX OUT DMX IN Power IN Power IN 12/24V DC Power supply 12/24V DC Power supply 230V AC 230V AC + R G B + R G B 12/24V DC LED tape 12/24V DC LED tape www.prolight.co.uk FTP3HP RGB LED DMX Driver User Manual 6

Related items Please contact your local retailer to purchase these related items. Visio TRI-RGB Flexible Tri-colour Strip (FLS-RGB) (5m roll) Order code: LEDC220 Visio TRI-RGB60 Flexible Tri-colour Strip (5m roll) Order code: LEDC227 Visio TRI-RGB60 Flexible Tri-colour Strip (5m roll) Black PCB Order code: LEDC227B Visio Meanwell SP-320-24 320W 24V DC Power Supply Order code: LEDC233 To keep up-to-date on the latest accessories and product range additions please visit www.prolight.co.uk www.prolight.co.uk FTP3HP RGB LED DMX Driver User Manual 7

WEEE notice Correct Disposal of this Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking shown on the product or its literature, indicates that it should not be disposed of with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal. www.prolight.co.uk FTP3HP RGB LED DMX Driver User Manual 8