NEC EXPRESS5800/R320b-M4 Configuration Guide

Similar documents
NEC EXPRESS5800/R320a-E4 Configuration Guide

NEC EXPRESS5800/R320b-M4 Configuration Guide

NEC EXPRESS5800/R320a-E4 Configuration Guide

NEC EXPRESS5800/R320a-E4 Configuration Guide

NEC EXPRESS5800/R320c-M4 Configuration Guide

NEC EXPRESS5800/R320d-E4 Configuration Guide

NEC EXPRESS5800/R320e-E4 Configuration Guide

NEC EXPRESS5800/E110d-1 Configuration Guide

NEC EXPRESS5800/R320d-E4 Configuration Guide

NEC Express5800/R320f Configuration Guide

NEC Express5800/R320f Configuration Guide

NEC EXPRESS5800/R320e-E4 Configuration Guide

NEC EXPRESS5800/R140b-4 Configuration Guide

NEC Express5800/R320g Configuration Guide

NEC EXPRESS5800/R320e-E4 Configuration Guide

NEC EXPRESS5800/GT110d-S Configuration Guide

NEC Express5800/B120e-h System Configuration Guide

NEC Express5800/B120f-h System Configuration Guide

NEC Express5800/E120b-1 Configuration Guide

NEC Express5800/B110d Configuration Guide

NEC Express5800/B120d-h System Configuration Guide

NEC Express5800/GT110e Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/GT110e-S Configuration Guide

NEC Express5800/R120d-2M Configuration Guide

NEC Express5800/GT110e-S Configuration Guide

NEC Express5800/R120d-1M Configuration Guide

NEC Express5800/R120e-2E Configuration Guide

1U Device Expansion Unit Configuration Guide

NEC Express5800/T110h-S System Configuration Guide

NEC Express5800/R120h-2M System Configuration Guide

NEC Express5800/R120f-1M System Configuration Guide

NEC Express5800/R120h-2E System Configuration Guide

NEC Express5800/R120g-1E System Configuration Guide

NEC Express5800/D120h System Configuration Guide

NEC Express5800/ft series

Acer AR320 F1 specifications

NEC Express5800/R120h-1M System Configuration Guide

NEC Express5800/R120h-1E System Configuration Guide

NEC Express5800/R120h-1E System Configuration Guide

Altos R320 F3 Specifications. Product overview. Product views. Internal view

Express5800/ A2040d/A2020d/A2010d/A1040d Configuration Guide

Express5800/ A2040d/A2020d/A2010d/A1040d Configuration Guide

System Configuration Guide

High Performance Computing

NEC Express5800/R110j-1 System Configuration Guide

Acer AR320 F2 Specifications

Acer AT310 F2 Specifications

Express5800/ A2040c/A2020c/A2010c/A1040c Configuration Guide

Acer AT110 F2 Specifications

Intel IP Network Server NSI2U

Altos T310 F3 Specifications

NEC Express5800/R120h-2M System Configuration Guide

GW2000h w/gw175h/q F1 specifications

Dual use as a high performance server and workstation

RS-200-RPS-E 2U Rackmount System with Dual Intel

FWA-6280A User Manual 1. FWA-6280A User Manual

System Configuration and order-information Guide TX150 S2. November 2005

Dual-Core Server Computing Leader!! 이슬림코리아

Suggested use: infrastructure applications, collaboration/ , web, and virtualized desktops in a workgroup or distributed environments.

Cisco MCS 7835-H2 Unified Communications Manager Appliance

Cisco MCS 7845-H1 Unified CallManager Appliance

System Configuration and Order-information Guide TX120. February 2009

GR585 F1 specifications

NOTE: Use the System Setup program to view microprocessor information. For more information, see "Using the System Setup Program."

HostEngine 5URP24 Computer User Guide

ThinkServer RD450 Platform Specifications

Integrated Ultra320 Smart Array 6i Redundant Array of Independent Disks (RAID) Controller with 64-MB read cache plus 128-MB batterybacked

Part Number Unit Descriptions

Acer AW2000h w/aw170h F2 Specifications

ThinkServer RD630 Photography - 3.5" Disk Bay*

Express5800/A2040e/A1040e Configuration Guide

System Configuration and order-information Guide RX200 S2. January 2006

Capacity driven storage server. Capacity driven storage server

System Configuration and order-information Guide RX600 S3. February 2007

GW2000h w/gw170h/d/q F1 specifications

Acer AC100 Server Specifications

Chapter 6 Cubix SP1 Blade Server

ftserver 3300 Service Bulletin

CISCO MEDIA CONVERGENCE SERVER 7825-I1

Cisco MCS 7816-H3. Supported Cisco Applications. Key Features and Benefits

The Genesis HyperMDC is a scalable metadata cluster designed for ease-of-use and quick deployment.


Pioneer DreamMicro. Rackmount 1U Server - S58 Series

Acer AN1600 F1 Network Storage System Specifications. Product Front view

Cisco MCS 7825-H3. Supported Cisco Applications

Cisco MCS 7815-I2 Unified CallManager Appliance

DNS-2608 Enterprise JBOD Enclosure User Manual

Fujitsu PRIMERGY TX100 S2 Server

IBM System x3755 SMP-capable rack server supports new dual-core AMD Opteron processors

Cisco MCS 7825-I1 Unified CallManager Appliance

Cisco MCS 7828-I5 Unified Communications Manager Business Edition 5000 Appliance

Data Sheet FUJITSU Server PRIMERGY CX2550 M1 Dual Socket Server Node

Cisco MCS 7815-I2. Serviceable SATA Disk Drives

QuickSpecs. HPE Cloudline CL7100 Server. Overview

Retired. Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

System Configuration and order-information Guide RX300 S2. June 2005

Supports up to four 3.5-inch SAS/SATA drives. Drive bays 1 and 2 support NVMe SSDs. A size-converter

The Cisco MCS 7835-H2 can run any of the following Cisco applications:

Cisco Connected Safety and Security UCS C220

Transcription:

NEC EXPRESS5800/R320b-M4 Configuration Guide Linux model Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC EXPRESS5800 server. November 2013 Revision 6.0 NEC Corporation

Contents TECHNICAL SPECIFICATION... 3 Key Features... 3 Specification... 3 EXTERNAL VIEWS... 5 Front and Rear Views... 5 Dimensions (mm)... 7 CONFIGURATION DIAGRAM... 8 SERVER CONFIGURATION... 9 1 Base Models... 9 2 2nd Processor... 9 3 Memory... 9 4 Internal Hard Disk Drives... 10 5 Optical Drive... 11 6 PCI Card... 12 7 Other Add-in Components... 12 7.1 Input Devices... 12 8 Add-on Components... 13 8.1 17-inch LCD Console Drawer... 13 8.2 KVM Switch... 13 8.3 Flash FDD... 13 8.4 Operating System... 13 8.5 Tower Conversion Kit... 14 8.6 External Tape Drives... 14 REFERENCES... 16 Note for Ordering... 16 Server Management... 16 Supported PCI Cards and Installable Slots... 17 Copyright Notice and Liability Disclaimer... 17 REVISION HISTORY... 18 NEC Corporation Revision 6.0, November 2013 2

Technical Specification Key Features Fault tolerant technology based on GeminiArchitecture TM Full manageability by integrated EXPRESSSCOPE Engine 2 High performance with the latest Intel Xeon processor 5600 series Up to 96GB of high speed DDR3-1333 memory Specification Model R320b-M4 Part Number N8800-163F Processor Type Intel Xeon processor X5670 Chipset Clock speed Logical Number of Processors Cache Cores and Threads 2.93 GHz 1 or 2 12 MB 6C / 12T Intel 5500 Chipset with GeminiEngine TM Memory Type DDR3-1333 ECC Registered DIMM Logical Standard Capacity Logical Maximum Capacity Memory protection 0GB Internal Storage Standard Capacity 0GB Expansion Slots [free] Maximum Capacity Disk Controller RAID Hot Plug 96GB (12 x 8GB) ECC, x4 SDDC 4.8 TB (8 x 600GB) SAS: 3Gb/s (Standard) SAS : RAID 1 (Standard) Supported Optical Disk Drive DVD Super Multi drive 1 Optical Drive Bays [free] Logical Disk Drive Bays [free] Standard 1 [0] 8 [8] Total: 4 slots available 2[2] x PCIe 2.0 x4 (x8 connector) 2[2] x PCIe 1.0 x4 (x8 connector) Video Controller (VRAM) Integrated in Server Management Controller (32MB) Interfaces Resolution / Color Supported Server Management EXPRESSSCOPE Engine 2 Power Supply Power Consumption (Max. Config, Operating) 800 x 600 / 16.7M, 1024 x 768 / 16.7M, 1280 x 1024 / 65K 1 x VGA (15-pin mini D-sub, 1 x rear per system) 4 x USB (1 x front, 3 x rear per system) 4 x 1000BASE-T LAN connector (1000BASE-T / 100BASE-TX / 10BASE-T, RJ-45, 2 x rear per CPU/IO module) 2 x Management LAN connector (100BASE-TX / 10BASE-T, RJ-45, 1 x rear per CPU/IO module) 100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz 1,400 VA / 1,390 Watt NEC Corporation Revision 6.0, November 2013 3

Model R320b-M4 1 2 3 Dimensions (W x D x H ) Weight (Minimum / Maximum) Temperature, Relative Humidity (non-condensing) Regulatory and Safety 483.0 x 736.0 x 178 mm / 19.0 x 29.0 x 7.0 in (4U) 46 kg / 52 kg, 101.41 lbs. / 114.64 lbs. Operating: 10 to 35 C / 50 to 95 F, 20 to 80% Non-Operating: -10 to 55 C / 14 to 131 F, 20 to 80% FCC, CE, BSMI, CCC, UL, CB, RoHS Operating Systems Red Hat Enterprise Linux 5.5/5.6/5.7/6.1/6.2 (EM64T) 2 3 Writing software is not provided for this DVD drive. Xen/KVM (Kernel-based Virtual Machine) is not supported. For Red Hat Enterprise Linux 5.6/5.7/6.1/6.2, new version of ft Server Control Software is required. Refer to 8.4 Operating System for details. NEC Corporation Revision 6.0, November 2013 4

External Views Front and Rear Views Front View A B C D E F G H I J A B K L M N O P Q R S T U Legend A. Drive Bays L. CPU Fault LED B. UID Button M. Memory Fault LED C. DVD Super Multi Drive N. Module Power LED D. System Power LED O. SAFE TO PULL LED E. System Status LED P. PRIMARY LED F. System FT LED Q. IO Module Fault LED G. UID LED R. Fan Fault LED H. USB Connector S. PSU Fault LED I. Pull-out Tab T. DC Power Fault LED J. Power Button U. Temperature Fault LED K. Module ID LED NEC Corporation Revision 6.0, November 2013 5

Rear View B C D A E F F G H I E Legend 1 A. USB Connectors F. AC Inlet B. Management LAN Connector G. Serial Port Connector 1 C. Module ID LED H. VGA Connector D. Data LAN Connectors I. PCI Slots (Full-Height) E. PCI Slots (Low-Profile) For service personnel only. NEC Corporation Revision 6.0, November 2013 6

Dimensions (mm) Rack mount 178 736 450 483 689 Tower Conversion (Optional) 220 804 592 327 NEC Corporation Revision 6.0, November 2013 7

Configuration Diagram Server CHASSIS REAR Optical Drive Bay CHASSIS FRONT Backplane CPU/IO Module CPU/IO Module CPU/IO module #0 : CHASSIS REAR DIMM #1 DIMM #2 DIMM #3 DIMM #4 DIMM #5 DIMM #6 CHASSIS FRONT PCI Riser PCIe 2.0 x4 (x8 socket) FH Processor Processor Cooling Fan #1 - #4 Drive Cage PCIe 1.0 x4 (x8 socket) LP PCIe 1.0 x4 (x8 socket) LP DIMM #7 DIMM #8 DIMM #9 DIMM #10 DIMM #11 DIMM #12 Power Supply CPU/IO module #1 : DIMM #1 DIMM #2 DIMM #3 DIMM #4 DIMM #5 DIMM #6 PCI Riser PCIe 2.0 x4 (x8 socket) FH Processor Processor Cooling Fan #1 - #4 Drive Cage PCIe 1.0 x4 (x8 socket) LP PCIe 1.0 x4 (x8 socket) LP DIMM #7 DIMM #8 DIMM #9 DIMM #10 DIMM #11 DIMM #12 Power Supply Legend: Minimum required components Standard components NEC Corporation Revision 6.0, November 2013 8

Server Configuration 1 Base Models Product Name / Description NEC EXPRESS5800/R320b-M4 no RAM, no 2.5-inch HDD Including: Intel Xeon Processor X5670, 1 x DVD Super Multi, EXPRESSBUILDER DVD Part Number N8800-163F 2 2nd Processor Available logical sockets: 1 Product Name / Description Intel Xeon Processor X5670 2nd Processor Kit : 2.93 GHz / 6C-12T / 12 MB, 2 processors included Part Number N8801-043 3 Memory Available logical slots: 6 per processor Product Name / Description Part Number 2GB DDR3-1333 REG Memory Kit : 2 x 2GB DIMM included N8802-050 12GB DDR3-1333 REG Memory Kit : 2 x 3 x 4GB DIMM included N8802-051 24GB DDR3-1333 REG Memory Kit : 2 x 3 x 8GB DIMM included N8802-046 NOTE: Minimum one memory kit must be installed. For RHEL6.1 and 6.2, at least 4GB of logical main memory is required. Memory Configuration Guideline See the table below for the number of memory kits required in accordance with logical main memory size and number of logical processors. Memory configurations which are not listed below are not supported in the system. Number of Logical Processors Logical Main Memory Size Number of Memory Kits Required 2GB 12GB 24GB 1 2GB 1 - - 4GB 2 - - 6GB 3 - - 8GB 4 - - 10GB 5 - - 12GB 6 - - - 1-24GB - 2 - - - 1 36GB - 1 1 48GB - - 2 NEC Corporation Revision 6.0, November 2013 9

Number of Logical Processors Logical Main Memory Size Number of Memory Kits Required 2GB 12GB 24GB 2 2GB 1 - - 4GB 2 - - 6GB 3 - - 8GB 4 - - 10GB 5 - - 12GB 6 - - 16GB 8 - - 20GB 10 - - 24GB 12 - - - 2-36GB 6 2-48GB - 4 - - - 2 72GB - 2 2 96GB - - 4 4 Internal Hard Disk Drives Available bays: 8 Product Name / Description Part Number 146.5GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 146.5GB N8850-042 300GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 300GB N8850-043 600GB 10K Hot Plug 2.5-inch SAS HDD : 1 x 600GB N8850-044 73.2GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 73.2GB N8850-045 146.5GB 15K Hot Plug 2.5-inch SAS HDD : 1 x 146.5GB N8850-046 NOTE: Hard drives must be installed in identical pairs to configure RAID 1. NEC Corporation Revision 6.0, November 2013 10

Required System Disk Capacity Required system disk capacity depends on the partition configuration pattern and memory size. Refer to the tables below for HDD requirements. For example, pattern 1 with 24GB memory requires 146.5GB or larger capacity HDD and pattern 3 with 96GB memory requires 300GB HDD. It is recommended to install hard drives providing the minimum required system disk capacity to reduce the time to resynchronize after a hard drive replacement. Pattern Setting Partition File system Size 1 1 /boot ext3 256MB /var/crash ext3 33GB / ext3 15GB swap swap 4 to 96GB 1 Free area - Remaining 2 /boot ext3 256MB /var/crash ext3 33GB / ext3 15GB swap swap 4 to 96GB 1 /home ext3 Remaining 3 /boot ext3 256MB /var/crash ext3 33GB / ext3 Remaining swap swap 4 to 96GB 1 Below 32GB: Memory size + 2GB, Over 32GB: Memory size Pattern Memory Size Required System Disk Capacity 1, 2 Up to 20GB 73.2GB 24GB to 48GB 146.5GB 72GB to 96GB 300GB 3 Up to 24GB 73.2GB 36GB to 72GB 146.5GB 96GB 300GB 5 Optical Drive Available bays: 1 Product Name / Description Internal DVD Super Multi Drive : 1 x DVD Super Multi drive, not including writing software Part Number (Standard) NEC Corporation Revision 6.0, November 2013 11

6 PCI Card Category Product Name / Description Part Number LAN Controller Fibre Channel Controller SAS Controller NOTE: 1000BASE-T 2ch board kit : 2 x GbE NIC Intel Gigabit ET Dual Port Server Adapter Fibre Channel board kit (8Gbps) : 2 x FC Controller QLogic QLE2560-SP 8Gbps Fibre Channel Adapters SAS Controller : 1 x SAS Controller LSI SAS3442E-R Host Bus Adapter NOTE: Up to one controller per module N8804-009 N8803-038 N8803-037 For supported NEC Storage products to connect with N8803-038, contact your sales representative or refer to the NEC Storage WEB site. (http://www.nec.com/global/prod/storage/) 7 Other Add-in Components 7.1 Input Devices Category Product Name / Description Part Number Keyboard USB Keyboard N8870-002AF Mouse USB Optical Wheel Mouse N8870-012 Cable USB cable : 1.5m USB extension cable K410-177(1A) NEC Corporation Revision 6.0, November 2013 12

8 Add-on Components 8.1 17-inch LCD Console Drawer Category Product Name / Description Part Number Drawer w/ KVM Switch Drawer w/o KVM Switch Drawer Cable Drawer 8.2 KVM Switch 17inch LCD Console Unit (1U/8port) 17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height Switch Unit Connection Cable Set (USB, 1.8m) 1.8 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 3m) 3 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB, 5m) 5 m, 1 x 15-pin mini D-SUB to 1 x 15-pin mini D-SUB / 1 x 4-pin USB A 17inch LCD Console Unit 1U 17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2m N8143-77F K410-118(1A) K410-118(03) K410-118(05) N8143-76F Category Product Name / Description Part Number KVM Switch Server Switch Unit (8 server) 1U USB 8 port KVM switch N8191-12F Cable KVM Switch Unit Connection Cable Set (USB,1.8m) 1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Switch Unit Connection Cable Set (USB,3m) 5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A Cascading Switch Unit Connection Cable 1.8 m 1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2 8.3 Flash FDD Order the Flash FDD if you need to prepare an alternative for a floppy drive. Product Name / Description Flash FDD USB flash emulating USB floppy disk, Native capacity 1.44 MB K410-118(1A) K410-118(03) K410-118(05) K410-119(1A) Part Number N8160-86 8.4 Operating System Red Hat Enterprise Linux 5.5 (EM64T) is supported on the R320a/R320b series. Purchase the OS and support service from a Red Hat reseller directly. To update to Red Hat Enterprise Linux 5.6/5.7 (EM64T), ft Server Control Software update is also required. For Red Hat Enterprise Linux 6.1 (EM64T), OS clean installation with new version of ft Server Control Software is required. For Red Hat Enterprise Linux 6.2 (EM64T), ft Server Control Software update is also required. The ft Server Control Software and installation procedures can be downloaded at http://www.nec.com/en/global/prod/express/download/ NEC Corporation Revision 6.0, November 2013 13

8.5 Tower Conversion Kit Product Name / Description Tower Conversion Kit 23 inch height pedestal with front bezel Part Number N8843-003 8.6 External Tape Drives 8.6.1 Tape Drive Selection Refer to the section in accordance with your type of tape drives. LTO LTO2 SAS Refer to 8.6.2 LTO3 SAS Refer to 8.6.2 LTO4 SAS Refer to 8.6.2 8.6.2 LTO / SAS Category Product Name / Description Part Number Controller Required External Cable Required Tape Enclosure Required Power Module Recommended Internal Cable Required Drive 2 bays available SAS Controller LSI SAS3442E-R Host Bus Adapter External SAS cable 2 m, 1 x SFF-8470 SAS to 1 x SFF-8088 Mini-SAS 2U Tape Drive Enclosure 4 x 5-inch media bays, two internal SAS cables included Power Supply 1 x non-hot plug power supply unit for redundant configuration Internal SAS cable 2 m, for 2U Tape Drive Enclosure internal connection NOTE: Required when three or more SAS connections (including other general purpose servers) to the N8141-59F Internal LTO (SAS) LTO3, Half height, Native capacity 400GB Internal LTO (SAS) LTO4, Half height, Native capacity 800GB Internal LTO (SAS) LTO5, Half height, Native capacity 1500GB Internal LTO (SAS) LTO6, Half height, Native capacity 2.5 TB N8803-037 K410-168(02) N8141-59F N8181-54F K410-249(00) N8151-102 N8151-90 N8151-103 N8151-106 NEC Corporation Revision 6.0, November 2013 14

8.6.3 Notes for double backup In a single backup configuration, in case a CPU/IO module or backup device fails, backup is not possible until the failed part is repaired or replaced. If this does not meet your system requirements, consider a double backup configuration. Refer to the following notes on double backup configuration. When configuring two sets of a SAS controller, a SAS cable and a backup device, two backup devices are recognized separately by the OS. When scheduling an automatic backup job, make a job for each backup device so that the other backup device can backup in case one device fails. In a double backup configuration, the device numbers of the tape devices may switch in the event of an IO module failover. When this occurs, automatic backup cannot be performed. To resolve the situation, re-enter the appropriate device settings again. 8.6.4 Supported backup software See the table below for the supported backup software on NEC EXPRESS5800/R320b. Tape drive Product Name / Description Internal LTO (SAS) LTO3, Half height, Native capacity 400 GB Internal LTO (SAS) LTO4, Half height, Native capacity 800 GB Internal LTO (SAS) LTO5, Half height, Native capacity 1.5 TB Internal LTO (SAS) LTO6, Half height, Native capacity 2.5 TB Backup software Part Number NetVault8.5/8.6 NetVault9.0 RHEL5.5 or later RHEL5.5 or later N8151-102 N8151-90 N8151-103 N8151-106 - NEC Corporation Revision 6.0, November 2013 15

References Note for Ordering Part numbers provided may be needed to modify by country/region when you order the products. For example, the operable part number for N8100-1738F in EMEA is N8100-1738F-O, adding "-O", the country-specific identifier for EMEA, after the part number. Please consult your sales representative for your country identifier. Server Management The EXPRESSSCOPE Engine 2, integrated into the server, provides superior remote control and system management features listed in the table below. 1 Hardware monitoring Boot monitoring Alerting Temperature/voltage/power/ fan /degeneration (memory/hard drive) Hardware event log collection Booting, BIOS/POST stall, OS stall, shutdown HW error, Boot error and OS panic (by SNMP, E-Mail) Remote console POST/BIOS setup, DOS utility (via LAN) Panic screen, Boot screen Text-based screen (OS console) - GUI-based screen (OS console) Remote control Remote reset - (via LAN) power on-off/ dump OS shutdown Remote media (CD/DVD/FD) Server Management Command Line Protocol (DMTF compliant) Remote control via Web browser (without dedicated app) Remote batch 1 Scheduling (without UPS) 1 Others Set automatic IP address via DNS/DHCP Remote wakeup Wake On LAN Centralized management Monitoring of multiple servers Control of multiple servers 1 Industry standard IPMI 2.0 DianaScope is required. NEC Corporation Revision 6.0, November 2013 16

Supported PCI Cards and Installable Slots Part Number Product Name Slots Notes Slot # : #1 #2 #3 #4 PCI Slot: x4 x4 x4 x4 Card height: LP LP FH FH Slot type: x8 x8 x8 x8 N8804-009 1000BASE-T 2ch board kit N8803-037 SAS Controller Max. 1 N8803-038 Fibre Channel board kit - - Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 6.0, November 2013 17

Revision History Revision Date Description 6.0 2013.11.20 New products added: Internal LTO / N8151-106 Discontinued products removed: N8151-101 Internal LTO(SAS) Others: Supported backup software matrix updated 5.1 2013.7.1 Red Hat Enterprise Linux 6.2 supported 5.0 2012.10.3 Red Hat Enterprise Linux 5.7 supported N8141-41F deleted (EOL) N8141-59F 2U Tape Drive Enclosure added N8151-77 (LTO4) deleted (EOL) Backup software support matrix added K410-119(1A) (cable for KVM switch cascading) added Description of K410-168(02) corrected 4.2 2012.5.23 SCSI Controller and related products deleted (EOL) 17-inch LCD Console Drawer and KVM Switch Part Numbers changed 4.1 2012.4.23 Keyboard Part Number corrected Mouse Part Number changed from N8170-22 to N8870-012 4.0 2011.11.25 Document form changed. Red Hat Enterprise Linux 5.6/6.1 supported Memory P/N changed. N8151-103 (LTO5) added in 8.6 External Tape Drives 3.0 2011.9.13 Mouse P/N corrected 2.0 2011.7.20 N8870-010A is deleted. (EOL) Supported software matrix for tape backup updated 1.0 2011.4.18 Initial release NEC Corporation Revision 6.0, November 2013 18