Manual Supplement. Manual Title: ESA609 Users Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13

Similar documents
Manual Supplement. Manual Title: ESA615 Users Supplement Issue: 2 Print Date February 2012 Date: 2/13 Revision/Date: 1 Page Count: 18

Manual Supplement. Manual Title: ESA615 Users Supplement Issue: 1 Print Date February 2012 Date: 6/12 Revision/Date: 1 Page Count: 9

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

Advanced Test Equipment Rentals ATEC (2832)

The low weight, small size, one-touch solution. Portable appliance testing. The Fluke 6000 series PAT testers

Autoranging True RMS Multimeter User Manual

ESA615 Electrical Safety Analyzer

Please use the Q & A utility to ask us any questions concerning the material being presented.

2200 Series. Quick Start Guide SAFETY CHECKLIST. Safety Made Simple

PRODUCT. Data Sheet. Introducing the new Fluke-287 Advanced Logging Multimeters with Trend Capture

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

OPERATING INSTRUCTION

LOW WEIGHT, SMALL SIZE,

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

PRODUCT. Data Sheet. The new Fluke-289 Advanced Logging Multimeters with Trend Capture

Fluke 43B. Power Quality Analyzer. Getting Started. EN June Fluke Corporation, All rights reserved. Printed in The Netherlands.

ESA615. Users Manual. Electrical Safety Analyzer

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Model A Mini AC/DC Clamp Meter. User's Guide

DM3058/DM3058E Digital Multimeter

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

ESA615. Electrical Safety Analyzer. Getting Started Manual

Relay Deck Datasheet

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Model 2657A-LIM-3 LO Interconnect Module

Power Prowler. Quick Start Guide. 3-In-1 DMM/TDR Cable Fault Finder for Energized and Unenergized Cables 600V CAT III. For Live Energized Cables

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

ESA601. Electrical Safety Analyzer. Getting Started Manual

SC6540. Quick Start Guide

Digital Clamp Meter User Manual

Manual Supplement. Manual Title: 1760 Users Supplement Issue: 4 Print Date: June 2006 Issue Date: 5/14 Revision/Date: 2, 5/10 Page Count: 4

ESA614. Electrical Safety Analyzer. Getting Started Manual

RTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version

MTP INSTRUCTION MANUAL

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

ScopeMeter. Accessories. PC Software. Protective Cases. Powering and Charging

Line Impedance Stabilization Network (LISN)

USER'S MANUAL DCL-650

Wa r n i n g-wa r n i n g-wa r n i n g

9040/9040UK. Users Manual. Phase Rotation Indicator

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

User Guide True RMS Multimeter Extech EX205T

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

WALKING TEST KIT WT5000

Model 7705 Control Module

Manual Supplement. Manual Title: 1760 Users Supplement Issue: 5 Print Date: June 2006 Issue Date: 2/18 Revision/Date: 2, 5/10 Page Count: 5

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Actuator Commissioning Tool

2 in 1 LAN Tester and Multimeter Model:

5 Performance Verification

Autoranging Mini Multimeter

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

GT-A81051-XXYY SERIES 5W

Model R5010. TRMS Digital Multimeter. Instruction Manual

Mini Digital Multimeter

Surge Protection for Surveillance Systems

HypotULTRA. Quick Start Guide SAFETY CHECKLIST. Survey the test station. Make sure it is safe & orderly.

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Hypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending)

earth ground) 2000 Vpeak (if neither input exceeds 1000 Vp rating to earth ground)

Mini Digital Multimeter

Detailed Specifications 6 1/2 Digits High-Performance DMM

* * Agilent Power Distribution Unit (PDU) Installation Guide

ClareHAL 104 Electrical Safety Tester

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Fluke 180 Series Digital Multimeters Features

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

MEASURING AND TESTING INSTRUMENTS

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Visit us at

Single-Output 2000 W GPIB

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

Digital Clamp-on Meter Instruction Manual

True RMS Digital Bench Multimeter Model:

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

REVISION HISTORY REV DESCRIPTION SALES RFS DATE A INITIAL RELEASE MS /20/2011 B UPDATE LABEL: CHANGE CQC PSE NAME TO COGNEX K.K.

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Application Note. Use of Palm Switches with QuadTech Hipot Testers

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

CAUTION CAUTION CAUTION HIGH VOLTAGE PRESENT

Manual for PSDC_OPT_EIGHT_01: Optics Power Supply

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

HYPOT III. Quick Start Guide

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

User's Guide. Extech AM A AC Analog Clamp Meter

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

700 Series 200 Amp Clamp Meters

Autoranging Mini Multimeter Model MN16A

Transcription:

Manual Title: Supplement Issue: 7 Print Date: February 2014 Date: 2/19 Revision/Date: 1 Page Count: 13 This supplement contains information necessary to ensure the accuracy of the above manual. This manual is distributed as an electronic manual on the following CD-ROM: CD Title: ESA609 CD Rev. & Date: 2/2014 CD PN: 4370089 2014-2019 Fluke Corporation. All rights reserved.

Change #1 On page 13, under the Performing a Ground-Wire (Protective-Earth) Resistance Test, replace the two bullets with. If using an accessories probe, connect it to the other end of the test lead and place the probe tip into the Ground Pin of the Analyzer s test receptacle. If using an alligator clip accessory, connect it to the other end of the test lead, place the null post adapter in the Ground Pin of the Analyzer s test receptacle, and clamp the alligator clip to the null post adapter. Change #2, 184, 185, 256 On page 2, add the following to the Symbols table: CAT II MEASUREMENT CAT II is applicable to test and measuring circuits connected directly to utilization points (socket outlets and similar points) of the low-voltage mains installation. On page 13, under the Performing a Ground-Wire (Protective-Earth) Resistance Test, add the following for Products shipped with a US outlet: Some configurations include a 15 A to 20 A adapter for units equipped with a 15 A test receptacle. Use the adapter to accommodate devices with 20 A power plugs. When this adapter is installed, use the included ground lug and zero out the resistance for Ground Wire (Protective Earth) Resistance measurements. If you do not zero the resistance, you must add an additional factor of 5 mω to the readings obtained in Ground Wire Resistance mode. 2/19 1

To zero the resistance for units with the adapter, follow the procedure on page 13, under Performing a Ground-Wire (Protective-Earth) Resistance Test, and replace the two bullets with: If using an accessories probe, connect it to the other end of the test lead and place the probe tip into the Ground Pin of the test receptacle. If using an alligator clip accessory, connect it to the other end of the test lead, place a ground pin adapter in the Ground Pin of the receptacle, and clamp the alligator clip to the ground pin adapter. On page 29, under Specifications, replace the Power section with: Power 115 Volt test outlet... 100/120 V ac rms, 50Hz/60Hz, 20 A maximum 230 Volt test outlet... 200/220/230/240 V ac rms, 50Hz/60Hz, 16 A maximum Power input... 115V 20A - 2.6 kva and 230V at 16A - 4.2 kva Change #3, 187 On page 30, under Leakage Current, replace the Accuracy with: Accuracy DC to 1 khz... ±(1 % of reading + 1 µa) 1 khz to 100 khz... ±(2.5 % of reading + 1 µa) 100 khz to 1 MHz... ±(5 % of reading + 1 µa) Change #4, 188 On page 29, under Specifications, remove the Agency approvals. 2 2/19

Change #5, 626 On page 26, under Table 6. Replacement Parts, change the Power Cord for USA to: USA 2238644 Change #6, 680 On page, 13 replace the Performing a Ground-Wire (Protective-Earth) Resistance Test section with: Performing a Ground-Wire (Protective-Earth) Resistance Test The Ground-Wire (Protective-Earth) Resistance test measures the impedance between the Analyzer s test receptacle s PE terminal and the exposed conductive parts of the DUT that are connected to the DUT s Protective Earth. Prior to conducting any leakage tests with the Analyzer, it is best to test the integrity of the ground connection between the Analyzer s test receptacle ground and the DUT s Protective earth ground or enclosure with this test. WX Warning To avoid electric shock, remove the null post adapter from the test receptacle after a test lead zero is performed. The test receptacle becomes potentially hazardous during some of the test conditions. 2/19 3

USA 120 VAC 60 Hz models: 1. Before connecting the Device Under Test (DUT) to the test receptacle, connect the Red test lead to the Red test lead opening on the front panel of the Analyzer. 2. Connect the Red alligator clip to the other end of the Red test lead on the Analyzer. 3. Insert the Ground Pin Adapter into the Ground opening on the Analyzer Test Receptacle. 4 2/19

4. Connect the Red alligator clip to the Ground Pin Adapter. 2/19 5

5. Turn on the Analyzer and wait for the power-up self-test to be completed. 5. Push the Ω test button on the front panel of the Analyzer. 6. Push F1 (Zero). 7. Observe that the displayed PE/Ground wire resistance is zero. 8. Connect the test lead coming from the red jack to the DUT enclosure or protective earth connection. 9. Plug the power cord from the DUT into the Analyzer s test receptacle. The measured resistance displays as shown in Figure 7 after any the DUT connections are made. Figure 7. Ground-Wire Resistance Test fis205.bmp 6 2/19

Euro/Shuko 240 VAC 50 Hz models: 1. Before connecting the Device Under Test (DUT) to the test receptacle, connect the Red test lead to the Red test lead opening on the front panel of the Analyzer. 2. Connect the Red alligator clip to the other end of the Red test lead on the Analyzer. 3. Connect the Red alligator clip to the ground in the Euro/Shuko Test Receptacle of the Analyzer. 2/19 7

4. Turn on the Analyzer and wait for the power-up self-test to be completed. 8 2/19

5. Select the Ω test button on the front panel of the Analyzer. 6. Push F1 (Zero). 7. Observe that the displayed PE/Ground wire resistance is zero. AUS/NZ 240 VAC 50 Hz models: 1. Before connecting the Device Under Test (DUT) to the test receptacle, connect the Red test lead to the Red test lead opening on the front panel of the Analyzer. 2. Connect the Red Test Probe (PN: 650887 with flat blade) to the other end of the Red test lead on the Analyzer. 2/19 9

3. Insert the Red Test Probe (PN: 650887 with flat blade) into the Ground opening of the Analyzer Test Receptacle. 10 2/19

4. Turn on the Analyzer and wait for the power-up self-test to be completed. 5. Select the Ω test button on the front panel of the Analyzer. 6. Push F1 (Zero). 7. Observe that the displayed PE/Ground wire resistance is zero. UK 240 VAC 50 Hz models: 1. Before connecting the Device Under Test (DUT) to the test receptacle, connect the Red test lead to the Red test lead opening on the front panel of the Analyzer. 2. Connect the Red Alligator clip to the other end of the Red test lead on the Analyzer. 3. Insert the NULL pin (shipped with the product) into the Ground opening of the Analyzer Test Receptacle. 2/19 11

4. Clip the Red Alligator clip to the NULL pin 12 2/19

5. Turn on the Analyzer and wait for the power-up self-test to be completed. 6. Select the Ω test button on the front panel of the Analyzer. 7. Press F1 (Zero) button. 8. Observe that the displayed PE/Ground wire resistance is zero. 2/19 13