Busmodul - LonWorks (R)

Similar documents
I/O module (Expansion module)

reflex accessories electronic modules The intelligent connection to your control room

INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

OT EASY 60 II. LED control unit Operating instructions

PXR11 PXR12. System controllers DESIGO PX

SK CU4-PBR-C Part number:

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

GFK-2415A March Type of sensor connection

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

SK TU4-PBR Part number:

This data sheet is only valid in association with the IL SYS INST UM E user manual.

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Expansion module EM-BAC-MOD-01. Installation manual

Accessories for stand-alone gird inverter SMART LOAD 6000

Supplementary instructions Sigma X control type with PROFIBUS

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

Installation and Operation Manual SPC1

SD1. Differential Controller. Operating and Installation Instructions F2 72.3

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

RMx621. Appendix to the operating manual

Carbon Monoxide Sensor - ModBus

Documentation. Mains filter AX2090-NF50. Version: Date:

RMx621 /FML621. Appendix to the operating manual

MU110-6U. Analog output module 6 channel. User guide

Autoranging True RMS Multimeter User Manual

SPA-ZC 200/SPA-ZC 202 IEC /SPA-gateway Modules. Installation Manual

Electrical devices may only be mounted and connected by electrically skilled persons.

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

SK CU4-CAO Part number:

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008

SK TU4-CAO-C Part number:

LevelControl Basic 2

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

OPERATING INSTRUCTION

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

Installation and Operation Manual DPC1

Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

Digital ac/dc (24V) Input Module

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

TPE, TPED Series 2000

IBS IL 24 BK RB-T-2MBD

AnyBus-PCI Profibus DPV1 Master

Allen-Bradley Motors

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

Supplementary operating instructions for your air curtain system Controller TMC 500

Intrinsically safe batch controller Batching Master 110i

IB IL 120 DI 1. Function. INTERBUS Inline Terminal With One Digital Input in the 120 V AC Voltage Area. Data Sheet 5764B

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

SCHMIDT Sensor interface PROFIBUS Instructions for use

MicroTech III Applied Terminal Systems BACnet MS/TP Communication Module

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

PanelView Plus/VersaView CE Terminals and Display Modules

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PSR DC/ESP4/2X1/1X2

Installation manual plugs and connectors with screw connection (16/32 A)

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

IF-80x Outdoor Terminal

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

TVAC25100 TVAC25110 User manual

LONWORKS Power Line Communication Adapter

PSR UC/ESAM4/3X1/1X2/B

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

External level devices for conductive point level switch

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

AXL E IOL AO1 U M12 R

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SK CU4-ECT-C Part number:

Operating Manual -ENGLISH- Page 1 KWG-ISO

270 MHz Control Modules

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Device manual Field modules DP AC2630 / AC2631 / AC2634 AC2636 / AC2637 / AC / / 2013

Nivotec 1. Table of contents. Level monitoring system NT 3500 Technical information / Instruction manual. Page

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

Installation Instructions

System CPX-E. IO-Link master module CPX-E-4IOL- Description. Protocol IO-Link. Function Parameterisation [ ]

D1210H dimmer pack. user manual

RITZ / Turbine controls DISPLAY

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Replacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 2120 Vibrating Fork Liquid Level Switch

Transcription:

Busmodul - LonWorks (R) 2014-04-08 GB Operating manual Original operating manual

English Busmodul - Busmodul - LonWorks (R) Contents 2014-04-08 Contents 1 Notes on the operating manual... 4 2 Models... 4 3 Technical data... 5 4 Connection... 6 4.1 RS-485 interface... 8 5 Settings... 9 5.1 Terminators of the RS-485 interface... 9 5.2 Commissioning LonWorks... 10 6 Network variables... 11 6.1 Network variables up to Version 2.00... 11 6.2 Network variables from Version 2.00... 14 7 Diagnosis... 16 8 Replacing the fuses... 17 9 Firmware update... 19 10 DIP switch... 21 10.1 Reflex Customer Service... 22 Busmodul - Busmodul - LonWorks (R) 2014-04-08 English 3

Notes on the operating manual 1 Notes on the operating manual Notice! Every person installing this equipment or performing any other work at the equipment is required to carefully read this operating manual prior to commencing work and to comply with its instructions. The manual is to be provided to the device operator and must be stored near the device for access at any time. 2 Models The "LonWorks " bus module enables you to provide the operating status of the REflex controller within a LonWorks network. The measured values and states of the controller are mapped on LonWorks network variables in the bus module. Other devices within the LonWorks network can read these network variables. There are two variants: Standard (R-S-I Art.No. 003544) The bus module assumes the "master function" on the RS-485 interface to the controller and retrieves the data. This variant is used only when the "network interface" (S1) is used to connect the bus module to the controller. Module bus interface version (R-S-I Art.No. 003546) The controller assumes the "master function". The bus module works as an "I/O module" and is cyclically polled by the controller. This variant is used when the bus module is connected to the "Control Touch" controller at the S2 module bus interface of Control Touch (in parallel to the main circuit board). Note! You use a DIP switch to select the mode, see chapter 10 "DIP switch" on page 21. 4 English Busmodul - Busmodul - LonWorks (R) 2014-04-08

Technical data 3 Technical data T H B 000227_001_R001 Housing Plastic housing Width 340 mm Height 233.6 mm Depth 77 mm Weight 2.0 kg Permissible operating temperature -5 C 55 C Permissible storage temperature -40 C 70 C Degree of protection IP IP 64 Voltage supply 230 V AC, 50 60 Hz (IEC 38) Fuses primary 0.25 A secondary 0.8 A LonWorks interface Transceiver FTT-1 A 78 kbit/s Connection with plug-in screw terminals Interface to the controller RS-485 or RS-232 19.2 kbit/s Floating Connection with plug-in screw terminals RSI-specific protocol Busmodul - Busmodul - LonWorks (R) 2014-04-08 English 5

Connection 4 Connection Danger electric shock! Risk of serious injury or death due to electric shock. Ensure that the system is voltage-free before installing the device. Ensure that the system is secured and cannot be reactivated by other persons. Ensure that installation work for the electric connection of the device is carried out by an electrician, and in compliance with electrical engineering regulations. The bus module is shipped with a power cable including earthed plug as standard. If required, you may use a different power cable. Proceed as follows: 1. Pull the power plug from the device. 2. Open the housing cover. The connection terminals are underneath the housing cover. 3 2 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 20 21 22 23 24 4 1 000232_001_R001 No. Component No. Component 1 COM 1 RS-232 interface 3 Power supply 230 V 2 COM 1 RS-485 interface 4 Interface for LonWorks 6 English Busmodul - Busmodul - LonWorks (R) 2014-04-08

Connection Terminal number Signal Function Wiring Power supply for the bus module 1 L 2 N 3 PE Interfaces for the bus module 4 Signal A (+) 5 Signal B (-) 6 Signal ground 7 Shielding (optional) 8 -- 9 -- 10 -- 11 -- 12 "RX" signal conductor for outgoing data 13 "TX" signal conductor for incoming data 14 "GND" signal ground 15 Shielding 16 -- 17 -- 18 -- 19 -- 20 NETA signal 21 NETB signal 22 Service key 23 Signal ground 24 Shielding Supply 230 V, maximal 16 A COM 1 RS-485 interface to the controller COM 2 RS-485 interface Currently not used COM 1 RS-232 interface COM 2 RS-232 interface Currently not used LonWorks interface On-site User supplied -- User supplied -- User supplied Note! You can connect the service key between the terminals 22 and 23. Busmodul - Busmodul - LonWorks (R) 2014-04-08 English 7

Connection 4.1 RS-485 interface Caution Device damage! Using an incorrect bus module may cause the destruction of the interface drivers. Ensure the use of a correct bus module. Proceed as follows: Provide the correct bus module. Use a shielded cable to connect the interfaces to terminals 4 to 7 of the main circuit board. Use a three-wire conductor as the interface is floating. Install a terminator at both ends of an RS-485 network. Activate the terminators. Note! Upon request, the Reflex Customer Service will provide the following information, see chapter 10.1 "Reflex Customer Service" on page 22. RS-485 interface protocol. Connection details. Details about the optional communication modules. 8 English Busmodul - Busmodul - LonWorks (R) 2014-04-08

Settings 5 Settings Danger electric shock! Risk of serious injury or death due to electric shock. Some parts of the main board may still carry 230V voltage even with the device physically isolated from the 230 V power supply. Before you remove the covers, completely isolate the device controller from the power supply. 5.1 Terminators of the RS-485 interface You must activate or deactivate the terminators at both ends of an RS-485 network. J1 J2 J3 J4 1 2 3 4 5 6 7 8 9 10 11 L1 N J1 J2 J3 J4 1 2 3 4 5 6 7 8 9 10 11 L1 N 12 13 14 15 16 17 18 19 12 13 14 15 16 17 18 19 000048_001_R001 Terminators are active Terminators are inactive Select the setting: Active setting of the terminators. The bus module is installed at the beginning or the end of the RS 485 network. For long conductors. Inactive setting of the terminators. The bus module is not placed at the beginning or the end of the RS 485 network. A short conductor directly connects the.bus module with the controller. Use of more than two devices. Proceed as follows: 1. Pull the power plug from the bus module. 2. Open the housing cover. 3. Select the required setting. Jumper J1 and J2 installed at the left side. The terminators are active. Jumper J1 and J2 installed at the right side. The terminators are inactive. The setting process for the terminators is completed. Note! The COM2 interface is inactive. The jumpers (J3-J4) are not functional. Busmodul - Busmodul - LonWorks (R) 2014-04-08 English 9

Settings 5.2 Commissioning LonWorks Danger electric shock! Risk of serious injury or death due to electric shock. Some parts of the main board may still carry 230V voltage even with the device physically isolated from the 230 V power supply. Before you remove the covers, completely isolate the device controller from the power supply. Only a specialist may integrate the bus module in the LonWorks network. The integration requires a LonWorks management tool: The XIF file of the bus module is provided on disk. Alternatively, you can diretly read the configuration from the bus module. The LonWorks management tool must be suited for this task. Note! The service key required for the installation can be connected to the terminals 22 and 23 on the bus module's main circuit board. 10 English Busmodul - Busmodul - LonWorks (R) 2014-04-08

Network variables 6 Network variables Note! This section describes the currently used configuration of the network variables. This an application-specific configuration not meeting the "LonMark Application-Layer Interoperability Guidelines". Version 2013-07-25 Program ID RSI_R003 XIF file Servako_2013-07-25.xif 6.1 Network variables up to Version 2.00 Network variables up to Version 2.00 NV Index Name SNVT Type 0 nvopressure SNTV_press (30) 1 nvolevel SNVT_lev_cont (21) 2 nvorunhoursp1 SNVT_time_hour (124) 3 nvorunhoursp2 SNVT_time_hour (124) 4 nvowatermeter SNVT_vol_kilo (42) 5 nvowatermeter_32 User defined (0) unsigned integer 32 bit 6 nvoinpstate SNVT_state (83) 7 nvooutpstate SNVT_state (83) 8 nvoerrorstate SNVT_state (83) 9 nvowarnstate SNVT_state (83) 10 nvocommstate SNVT_state (83) 11 nvolevel_16 SNVT_lev_percent_ (81) 12 nvopressure2 SNVT_press (30) Busmodul - Busmodul - LonWorks (R) 2014-04-08 English 11

Network variables Explanations to the network variables up to Version 2.00 Communication status nvocommstate.bit0 Faulty connection between controller and bus module. The other network variables are invalid System pressure nvopressure Not with Servitec with Levelcontrol operating mode SNVT_press type Pressure filling pipe nvopressure2 Only with Servitec SNVT_press type Filling level nvolevel nvolevel16 Not with Servitec SNVT_lev_cont type Range limited to 100 % SNVT_lev_percent type Identical value but different type Operating hours Pump 1 or Compressor 1 nvorunhoursp1 SNVT_time_hour type Operating hours Pump 2 or Compressor 2 nvorunhoursp2 SNVT_time_hour type Water meter nvowatermeter nvowatermeter_32 Accumulated sum SNVT_vol_kilo type Resolution 100 litres User defined, 32 bit unsigned Integer Resolution 1 litres Status Digital inputs nvoinptstate.bit0 Feedback Pump 1 nvoinptstate.bit1 Feedback Pump 2 nvoinptstate.bit2 Insufficient water switch Status nvooutpstate.bit0 nvooutpstate.bit1 nvooutpstate.bit2 nvooutpstate.bit3 nvooutpstate.bit4 nvooutpstate.bit5 nvooutpstate.bit6 nvooutpstate.bit7 Digital outputs Pump 2 ON Pump 1 ON Overflow valve 2 OPEN Overflow valve 1 OPEN Make-up valve OPEN Message: min. level Message: Group fault Message: Make-up fault Identical value but different types only 12 English Busmodul - Busmodul - LonWorks (R) 2014-04-08

Network variables Faults nvoerrorstate.bit0 Expansion module Option defective EEPROM defective Undervoltage Below minimum pressure Insufficient water nvoerrorstate.bit1 nvoerrorstate.bit2 nvoerrorstate.bit3 nvoerrorstate.bit4 nvoerrorstate.bit5 Fault pump 1 nvoerrorstate.bit6 Fault compressor 1 nvoerrorstate.bit7 Fault pump 2 nvoerrorstate.bit8 Fault compressor 2 nvoerrorstate.bit9 nvoerrorstate.bit10 nvoerrorstate.bit11 nvoerrorstate.bit12 nvoerrorstate.bit13 Insufficient water 2 Only with Servitec Fault pressure measuring Level measurement fault Fault pressure measuring in spray tube Only with Servitec The device is in "STOP" mode for more than 4 hours Warnings nvowarnstate.bit0 nvowarnstate.bit1 nvowarnstate.bit2 nvowarnstate.bit3 nvowarnstate.bit4 nvowarnstate.bit5 nvowarnstate.bit6 nvowarnstate.bit7 nvowarnstate.bit8 nvowarnstate.bit9 nvowarnstate.bit10 nvowarnstate.bit11 nvowarnstate.bit12 nvowarnstate.bit13 nvowarnstate.bit14 nvowarnstate.bit15 Not used Maximum level exceeded Pump runtime exceeded Make-up time exceeded Make-up cycles exceeded Maximum pressure exceeded Make-up quantity exceeded Filling time exceeded Only with Servitec Filling quantity exceeded Only with Servitec Discharge period exceeded Only with Servitec Make-up valve leaking Power failure Null balancing defective Parameter defective Maximum make-up quantity exceeded Maintenance requested Busmodul - Busmodul - LonWorks (R) 2014-04-08 English 13

Network variables 6.2 Network variables from Version 2.00 Network variables from Version 2.00 NVIndex Name SNVT Type 13 nvoerrorstate2 SNVT_state (83) 14 nvoerrorstate3 SNVT_state (83) 13 nvowarnstate2 SNVT_state (83) 14 nvowarnstate3 SNVT_state (83) 15 NvoRunHoursP1_32 User defined (0) unsigned integer 32 bit 16 NvoRunHoursP2_32 User defined (0) unsigned integer 32 bit Explanations to the network variables from Version 2.00 Faults nvoerrorstate2.bit0 Main circuit board fault Not with "Control Basic" controller nvoerrorstate2.bit1 Digital input voltage fault Not with "Control Basic" controller nvoerrorstate2.bit2 Analogue input voltage fault Not with "Control Basic" controller nvoerrorstate2.bit3 Input voltage ball valve 1 fault nvoerrorstate2.bit4 Input voltage ball valve 2 fault nvoerrorstate2.bit5 "Pressure" jumper fault Not with "Control Basic" controller nvoerrorstate2.bit6 "Level" jumper fault Not with "Control Basic" controller nvoerrorstate2.bit7 Pump running dry Only with "Control Basic" controller nvoerrorstate2.bit8 Insufficient water 3 Only with "Control Basic" controller nvoerrorstate2.bit9 Insufficient water 4 Only with "Control Basic" controller Faults nvoerrorstate3 Currently not used 14 English Busmodul - Busmodul - LonWorks (R) 2014-04-08

Network variables Warnings nvowarnstate2.bit0 Replace battery Not with "Control Basic" controller nvowarnstate2.bit1 Softening, replace cartridge nvowarnstate2.bit2 Check data logger nvowarnstate2.bit3 nvowarnstate2.bit4 The device is in "STOP" mode for more than 4 hours Only with "Control Basic" controller Warnings Expansion module nvowarnstate3.bit0 Message digital input 1 nvowarnstate3.bit1 Message digital input 2 nvowarnstate3.bit2 Message digital input 3 nvowarnstate3.bit3 Message digital input 4 nvowarnstate3.bit4 Message digital input 5 nvowarnstate3.bit5 Message digital input 6 nvowarnstate3.bit6 Message digital output 6 Operating hours Pump 1 or Compressor 1 nvorunhoursp1_32 32 Bit, unsigned Integer. Resolution 1 hour Operating hours Pump 2 or Compressor 2 nvorunhoursp2_32 32 Bit, unsigned Integer. Resolution 1 hour Busmodul - Busmodul - LonWorks (R) 2014-04-08 English 15

Diagnosis 7 Diagnosis Danger electric shock! Risk of serious injury or death due to electric shock. Some parts of the main board may still carry 230V voltage even with the device physically isolated from the 230 V power supply. Before you remove the covers, completely isolate the device controller from the power supply. The bus module features 6 LEDs indicating the operating state. LED1 and LED2 are located in the terminal space next to the terminal strip for the interfaces. LED3 to LED6 are located on the LonWorks plug-in module. LED 1 and LED 2 in the terminal space 1 2 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 000225_001_R001 No. Component No. Component 1 LonWorks plug-in module 3 LED 2 2 LED 1 LED 1 function: Visual signal display of the controller connection Illuminated in normal mode. The LED illuminates when a connection to the controller is established. The LED flashes when there is no connection to the controller. LED 2 function: Visual signal display for the detection of the field bus module. Switched off in normal mode The LED flashes when the LonWorks plug-in module has not been detected. Alternate flashing of the LEDs 1 and 2 indicates that the bus module is in "firmware update" state: DIP switch 8 is set to "ON". A previous firmware update has been aborted. 16 English Busmodul - Busmodul - LonWorks (R) 2014-04-08

Replacing the fuses LEDs 3 to 6 on the LonWorks plug-in module 1 3 4 5 6 000233_001_R001 No. Component 1 LEDs 3 to 6 LED 3 function: No function. Not used for visual signal. LED 4 function: Visual maintenance display of the bus module The LED is switched off. The bus module is installed in a LonWorks network and works correctly. The LED flashes "green". The bus module is not installed in a LonWorks network. The LED illuminates "green". Fault in the bus module: 1. Switch off the power supply of the bus module. 2. Switch on the power supply of the bus module. 3. The bus module is defective if the fault is still present. LED 5 function: Visual signal for the bus module status. The LED illuminates "green". The bus module works correctly. The LED illuminates or flashes "red". Fault in the bus module: 1. Switch off the power supply of the bus module. 2. Switch on the power supply of the bus module. 3. The bus module is defective if the fault is still present. LED 6 function: Visual signal display of the "wink" command. The LED flashes "red" A "wink" command is received via the LonWorks network. 8 Replacing the fuses Busmodul - Busmodul - LonWorks (R) 2014-04-08 English 17

Replacing the fuses Danger electric shock! Risk of serious injury or death due to electric shock. Some parts of the main board may still carry 230V voltage even with the device physically isolated from the 230 V power supply. Before you remove the covers, completely isolate the device controller from the power supply. The fuses are installed in the terminal space of the bus module. 2 1 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 000230_001_R001 No. Component No. Component 1 Feeble current fuse F1 2 Feeble current fuse F2 250 V 250 V 0.25 A time-lag 0.8 A time-lag Proceed as follows: 1. Disconnect the bus module from the power supply. Pull the power plug from the bus module. 2. Open the housing cover. 3. Replace the defective fuses. 4. Close the housing cover. 5. Reconnect the power supply for the bus module. The fuse replacement is completed. 18 English Busmodul - Busmodul - LonWorks (R) 2014-04-08

Firmware update 9 Firmware update Danger electric shock! Risk of serious injury or death due to electric shock. Some parts of the main board may still carry 230V voltage even with the device physically isolated from the 230 V power supply. Before you remove the covers, completely isolate the device controller from the power supply. A new firmware version is loaded to the bus module using the "COM1" serial interface. 1 2 ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 No. Component No. Component 1 DIP switch 2 LonWorks plug-in module To load the new firmware to the bus module, you need: A PC with an RS 232 interface. A software for flash programming for the PC. flash-xxx.exe The new firmware for the bus module (*.hex). To connect the "COM1" interface, you have two options: COM 1 RS 485. Terminals 4 7 COM 1 RS 232. Terminals 12 15 Connect a "COM1" of the bus module with the RS-232 interface of the PC. You need: RS 232/RS 485 converter. For terminals 4 7 Optional flash programming adapter. For terminals 4 7 Optional cable for the direct connection of the PCs RS 232 interface with the bus module. For terminals 12 15 000222_001_R001 Busmodul - Busmodul - LonWorks (R) 2014-04-08 English 19

Firmware update To load the new firmware, proceed as follows: 1. Disconnect the bus module from the 230V power supply. 2. Open the housing cover. 3. Set the DIP switch "8" to "ON". Do not change the settings of the other DIP switches "1 7". 4. Remove the connection between the Reflex controller and the bus module. 5. Connect the selected "COM1" interface with the PC. 6. Close the housing cover of the bus module. 7. Connect the bus module to the 230V power supply. 8. Start the "Flash programming" program on the PC. 9. In the program, click "Open". 10. Select the required HEX file in the program. 11. In the program, click "Burn". If necessary, change the interface setting in the program. 12. Click "OK" to start the programming process. 13. Close the program when programming has completed. The status bar displays the progress of programming. 14. Disconnect the 230V power supply of the bus module. 15. Open the housing cover of the bus module. 16. Disconnect the "COM 1" connection between PC and bus module. 17. Re-connect the Reflex controller and the bus module. 18. Set the DIP switch "8" to "OFF" for the bus module to enter the operating mode when switched on. Do not change the settings of the other DIP switches "1 7". 19. Close the housing cover of the bus module. 20. Re-connect the 230V power supply of the bus module. 21. Check the functioning of the bus module. Loading the new firmware to the bus module is completed. 20 English Busmodul - Busmodul - LonWorks (R) 2014-04-08

DIP switch 10 DIP switch DIP switch settings ON 1 2 3 4 5 6 7 8 1 2 ON 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 1 2 3 4 5 6 7 8 000224_001_R001 DIP switch: Designation: DIP switch: Designation: Magnifier 1 Bus module for LonWorks 4 Reserved (optional) Standard design Magnifier 2 Bus module for LonWorks 5 Reserved (optional) MK200 design Module bus interface version Control Touch» RS485-s2 1 "COM1" interface function. "ON": Slave "OFF": Master 2 Selection of the used field bus plug-in module. "ON": RSI Profibus module (Profibus bus module) "OFF": HMS AnyBus module (other bus modules) 6 FTP and Tenet activation. "ON": FTP and Telnet activated (for diagnostics) "OFF": Standard operation 7 Switch to configuration mode. (currently only internally used by RSI) "ON": Configuration mode "OFF": Standard operation 3 Reserved 8 Switch to firmware update mode. "ON": Firmware update "OFF": Standard operation Note! Change the DIP switches when a firmware update is executed on the bus module. Note! The bus module reimports the DIP switch settings when the power supply is switched on or off. Busmodul - Busmodul - LonWorks (R) 2014-04-08 English 21

DIP switch 10.1 Reflex Customer Service Central customer service Switchboard: Telephone number: +49 (0)2382 7069-0 Customer Service extension: +49 (0)2382 7069-9505 Fax: +49 (0)2382 7069-523 E-mail: service@reflex.de Technical hotline For questions about our products Telephone number: +49 (0)2382 7069-9546 Monday to Friday, 8:00 a.m. 4:30 p.m. 22 English Busmodul - Busmodul - LonWorks (R) 2014-04-08

SIXXXXen / 91XXXXX / 04-14 Reflex Winkelmann GmbH Gersteinstraße 19 59227 Ahlen, Germany Telephone: +49 (0)2382 7069-0 Fax: +49 (0)2382 7069-588 www.reflex.de