DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

Similar documents
Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

MED102A. Industrial Serial to Single-mode Fiber Converter

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Product Specification for SAB-S-MODBUS

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

KTA-250 Anemometer Alarm Card

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

K107A / K107B Half-duplex RS485 serial bus with 3-point insulation

2562 QUICK START GUIDE

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

TCNM-ACBB1 Installation Manual

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

RS485 MODBUS Module 8AO

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

8520/8520R. User Manual

RS485 MODBUS Module 8I8O

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

ICF-1150 Series Quick Installation Guide

MU110-6U. Analog output module 6 channel. User guide

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Mini Energy Web Server

LVX Control Unit. Features:

SYSTEMS ELECTRONICS GROUP

Saturn Reader User Manual

ECS ecompass Series. ECS ecompass Series. Strap down Electronic Compass. General Description. Features. Making Sense out of Motion

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

Electronic SD1, AS 8, ASR 14, ASR 20

Trident and Trident X2 Digital Process and Temperature Panel Meter

Manual Fiber Optic Interfaces

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

The JT-DO1 GPS-disciplined IRIG-B timecode generator produces timecode according to the IRIG-

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

Buffered Power Supply PS-30DR v1.0

MINI MCR-SL-PT100-UI-200

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

CuteLine AIN8 UI - Voltage Current. Manual

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

Operating Instructions. TCM Timer Counter Module Typ 686

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

PK2200 Series. Features. C-Programmable Controller. Specifications Board Size Enclosure Size Operating Temp.

Manual and Protocol Description

MRUC-20 Modul-R CAN Bus Network

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

icex-cmtm General specs and Installation guide

Maximum Value for OEMs SM. NX70 Serial Communications Unit (SCU) User Manual

Manual 601: : USB/RS232. Specifications. Contents. Options

Communication Controller CC-Link/CPL Converter CMC10A

RS485 MODBUS Module 6RO

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

dual-line 6-dIGIt process MeteR

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Carbon Monoxide Sensor - ModBus

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Aceprox FSK Proximity Reader REV2 Data Sheet

Installation Instructions 45MLA Controller

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

PAC BI-DP BIM and 8701-CA-BI Carrier

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

F3EM Measuring lightcurtain in robust aluminium housing

8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user

ASTAT XB/XBm Remote Operator

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Moxa TCC-100 Series User s Guide

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

RS485 MODBUS Module 16I-M

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

ICF-1150 Series Quick Installation Guide

45SD Series Bus Expansion Cards For use with Q45X Series Photoelectric Sensors on SDS Bus Networks

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

Installation Guide Serial Interface T942SI

A general-purpose industrial input/output

User Manual. cmt-svr Startup Guide

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

MC CO MODBUS ADDRESSABLE SENSOR

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Measurement Systems Datascan Installation and User Guide

GmbH, Stettiner Str. 38, D Paderborn

UNIVERSAL CURRENT CONVERTER

RPS-401A, RPS-426A Self-Contained Ultrasonic Sensor

MC 11 EB-2 Power supply cabinet with external bus, AC version

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Identification System CIS3A-Mini

SST-2450 Wireless Modem User s Manual

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

RS 485 Mini Modbus 1AO

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

Transcription:

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL 1

TABLE OF CONTENTS 1. MOUNTING INSTRUCTIONS 1.1 Standard DIN Rail mounting 1.2 Screw Mounting 2. FUSE REPLACEMENT 3. ASSEMBLING THE UNIT 4. SUPPLY VOLTAGE 5. MODES OF OPERATION 5.1 0-20/4-20mA output current selection 5.2 Switch Setting Table 6. PARALLEL CONTROL MODE 6.1 Parallel Mode - PLC Interface 6.2 The "E" (ENABLE) Terminal 7. SERIAL CONTROL MODE 7.1 RS-232C/RS-422 Select 7.2 RS-422 termination 7.3 Serial control switch settings 7.4 Serial communication parameters 7.4.1 Baud Rate Select 7.4.2 DCC-8 ID Code 7.4.3 DCC-8 Command Formats 8. SELF TEST MODE 8.1 SELF TEST # 1 (Communication Ports) 8.2 SELF TEST # 2 (Same Level) 8.3 SELF TEST # 3 (Saw Tooth) 9. MULTIDROP CONFIGURATION 10. PUTTING THE UNIT INTO OPERATION 11. DCC-8 CALIBRATION 12. SPECIFICATIONS 2

1. MOUNTING INSTRUCTIONS The DCC-8 is designed be mounted on standard DIN rail. Place the unit on the upper part of the mounting rail with the fastening tab facing down. Loosen the tab slightly, using a suitable flat screwdriver, and attach the unit to the rail. After releasing the tab, make sure that the unit is fastened securely in place. 2. FUSE REPLACEMENT In order to replace a blown fuse, the unit has to be disassembled, as follows: 2.1 Take off both terminal strips by removing the four screws at the edges. Note: This does not require disconnecting the cables connected to the strips. 2.2 Remove the front panel using a suitable flat screwdriver. Press down gently on the plastic spring-loaded tabs located in the slots on either side of the unit. 2.3 Disconnect the flat connector which connects the front panel. 2.4 Replace the blown fuse. WARNING: Never install a fuse rated more than 800mA. 3. ASSEMBLING THE UNIT The DCC-8 unit includes two printed circuit cards designated as P.N 7041 and P.N 7040. The two printed circuit boards should occupy the slots in the enclosure according to fig 1. Figure 1 3

3.1 Assembling Procedure Insert the two printed cards into their slots. Connect the flat cable between them. Connect the front panel flat cable. The panel must be inserted into the grooves on both sides of the case while pressing down until a distinct "click" is heard. Assembly is completed by laying the terminal strips in place. Note: Because of their polarity, the terminal strips must not be placed backwards. 4. SUPPLY VOLTAGE The DCC-8 is fed by a DC power supply at a range of 15-32 Vdc. In order to determine the minimum supply voltage, use the following equation: V min = 8 + R load * 0.02 where: V min is the minimum required supply voltage (e.g. 15V). R load is the maximum output load including the leads resistance. Note: If V min turns to be less than 15V, the minimum required voltage should be 15 Vdc. 5. MODES OF OPERATION The DCC-8 unit can be operated in four modes of operation. 4-20 or 0-20mA output current selection Parallel control mode Serial control mode Self test mode An internal array of 8 dip-switches determines the selected mode of operation. 5.1 0-20 or 4-20mA Output Current Selection Two current output spans are available: 4-20mA or 0-20mA. SW-6 selects between the two spans. The DCC-8 receives 12 bit data which determines the output current value. Channel data value of 4095 (FFF) is always interpreted as a 20mA output current. Channel data value of 0 (000) will produce a 0mA output current when SW-6 is OFF, or 4mA when ON. Switch Setting Table PARALLEL 0-20mA OFF OFF X X X OFF OFF PARALLEL 4-20mA OFF OFF X X X ON OFF 4

5.2 Parallel Control Mode Switch Setting Table PARALLEL 0-20mA OFF OFF X X X * OFF PARALLEL 4-20mA OFF OFF X X X * OFF 5.3 Serial Control Mode Switch Setting Table 300 BPS OFF OFF UNIT ID CODE ON= 4-20mA 4800 BPS ON OFF UNIT ID CODE ON 9600 BPS OFF ON UNIT ID CODE OFF=0-20mA 19200 BPS ON ON UNIT ID CODE ON ON ON SW-5 =MSB 5.4 Self Test Mode Switch Setting Table SELF TEST #1 ON OFF X X OFF SELF TEST #2 OFF ON X * OFF SELF TEST #3 ON ON X * OFF * according to para #5.1 6. PARALLEL CONTROL MODE * according to para #5.1 PARALLEL MODE OFF OFF X * OFF 5

In the parallel control mode, the DCC-8 unit is controlled via a 15 bit bus. 3 Address bits (A0-A3) select the proper current output channel and 12 Data bits (D0-D11) determine its value (A0 and D0 are MSB). The DCC-8 microprocessor continuously scans the input vector terminals and updates its memory tables as soon as it recognizes new vector. The unit is asynchronous in nature. The data should be valid for at least 160 micro-seconds. 6.1 Parallel Mode - PLC Interface The PLC's output modules can be divided into three popular types; TTL output module, 24Vdc sink type and 24Vdc source type. There is a jumper selector on printed circuit card 7040 which selects between Sink/Source input. (TTL output module should be consider as sink type). See figure 2. 6.2 The "E" (ENABLE) Terminal Fig. 2 For E = "1" the unit is enabled, which means that all input vectors are received and the output is updated. When E="0" the unit ignores any new input vectors. The E terminal is recommended to be used as a strobe for parallel data which has a long setup time. In this case the following sequences recommended: prior to applying a new vector, the E terminal should be set to logical 0 (inhibit state) then the new input vector should be imposed. When the data is ready - the E terminal should be pulsed. The E terminal is used for multi-drop configuration. The 15 bit vectors are applied to the units in parallel to all units and the selection is carried out by controlling the "E" inputs. 7. SERIAL CONTROL MODE 7.1 RS-232c/RS-422 Select The DCC-8 is equipped with two serial communication ports: The RS-232c and the RS-422. A jumper switch at the right side of the dip-switch array is used to select the required communication protocol. See figure 3. Fig. 3 6

7.2 RS-422 Termination S.W. #8 when ON, inserts 100Ω terminator resistor to the RS-422 transmission line. In a multi-drop configuration, the most far DCC-8 unit should be terminated in order to match the transmission lines. Note: Only one termination load per RS-422 communication link is permissible. 7.3 Serial Control Switch Settings * according to para #5.1 BAUD RATE ID CODE * ON 7.4 Serial Communication Parameters The communication protocol is: Data: 8-bit, Parity: even Stop bit: one 7.4.1 Baud Rate Select SW-1 and SW-2 select one out of four available baud rates. SW1 SW2 300 BPS OFF OFF 4800 BPS ON OFF 9600 BPS OFF ON 19200 BPS ON ON 7.4.2 DCC-8 ID Code Up to eight DCC-8s can be connected in a multi-drop configuration. Switches SW-3, SW-4, and SW-5 (SW-5 is MSB) set the ID code. 7.4.3 DCC-8 Command Formats Three types of command formats are available: Without echo-back The host computer sends a massage and does not receives an acknowledgment. With echo-back The host computer sends a message and receives an acknowledgment stating the DCC-8 ID number and the addressed channel number. Status report 7

7.4.3.1. Without Echo-Back Format [A] [DCC-8 ID CODE] [CHANNEL NUMBER] [CHANNEL VALUE] [CR] The first byte is the character "A". It begins the command block. The second byte is the ID code (0-7). The third byte is the addressed channel number (0-7). Up to four bytes of a channel's value can be in BCD mode (0-4095). Leading zeroes can be omitted. The last byte is [CR] which must terminate the command block. 7.4.3.2. With Echo-Back Format [C] [DCC-8 ID CODE] [CHANNEL NUMBER] [CHANNEL VALUE] [CR] This format differs only in the opening character. After every command block transfer, the DCC-8 echoes back the following: [C] [DCC-8 ID CODE] [CHANNEL NUMBER] [LF] [CR] Note: If the value is omitted it will be treated as zero. Separators such as blanks or commas are not allowed. Example: Channel 4 in DCC-8 no. 7 has to receive the value of 981. Echo back is required The command format is: The echo back will be: C 7 4 [C] [7] [4] [981] [CR] Note: Note: The channel numbers on the DCC-8 front panel are designated from 1 to 8, in binary they are designated from 0 to 7. When applying the echo-back mode, it is advisable to wait for the echo back before transmitting a new command. 7.4.3.3 Status Report Format [S] DCC-8 ID CODE] [CR] The addressed DCC-8 unit will respond with the values stored in its eight channels. The response will start with S, DCC-8 ID CODE, following with eight channel values separated with commas and [LF] [CR] as terminators. Example DCC-8 number 3 has the following stored data: ch1: 300, ch2: 1270, ch3: 0, ch4: 4087, ch5: 2099, ch6: 764, ch7: 3078, ch8: 550. The response from the device will be: S3,300,1270,0,4087,2099,764,3078,550 [LF] [CR]. Note: Wait until the status report has terminated before transmitting new commands. 8

8. SELF TEST The DCC-8 is provided with three test modes. SELF TEST #1 ON OFF X X OFF SELF TEST #2 OFF ON X * OFF * according to para #5.1 SELF TEST #3 ON ON X * OFF 8.1 Self Test #1 (Communication Ports Test) In order to test the serial communication ports, this test mode converts the unit to a transponder for ASCII characters. Any transmitted character will be echoed to the host terminal. The host parameters should be set to: Baud rate : 4800 Data: 8 bits Parity: even Stop bit: 1 8.2 Self Test #2 (Same Level) In this test mode, the DCC-8 unit ignores the address field. All the outputs are set according to the data field only. 8.3 Self Test #3 (Saw Tooth) In this test mode, only one output channel (according to the address setting) will produce a saw tooth wave form in which the whole value range is used. 9. MULTIDROP CONFIGURATION Up to eight DCC-8 units can be installed in a multi-drop configuration using the RS-422 communication port. All the (DCC-8) RS-422 receiver (Rx) terminals are connected to the controller's RS-422 output driver, while all the (DCC-8) RS-422 transmitter (Tx) terminals are connected to the controller's RS-422 receiver. As the communication cable might be several thousand feet long, it is necessary to terminate the end of the line with its characteristic impedance in order to avoid reflections in the transmission line and data distortion. SW-8 in its ON state terminates the Rx inputs with a 100Ω load. 10. PUTTING THE UNIT INTO OPERATION The DCC-8 is supplied configured to parallel control mode. The dip-switch setting is: PARALLEL 4-20mA OFF OFF OFF OFF OFF ON OFF The communication port selector (see para #7.1) is set to RS-232C. 9

1. First determine the required configuration. 2. Disassemble the unit in order to set the dip-switch array accordingly (see instructions in para #5). 3. Connect the unit to the supply. The channel LED s are connected in series with the output current so that they will light only when the output current is flowing, indicating the existence of a closed current loop. The DCC-8 stores the last updated value of output current in its memory. As long as no power failure has occurred, no restoring is needed. However, in the serial control mode it is possible to monitor the unit's memory by using the "Status Report" command. After every power on, the unit is reset and the initialized default output currents are according to SW-6 setting (see para #5.1). 11. DCC-8 CALIBRATION Generally there is no need to calibrate the DCC-8 unit. However if calibration is required, please follow the following instructions. Two potentiometer trimmers, one for "Zero" and the other for "Span" are located on printed card 7040. The trimmer which is close to the card edge is the "Zero". Use the following switch setup for switching the outputs between 4 and 20mA. ALL CH.= 4mA OFF OFF X X X ON OFF ALL CH.= 4-20mA OFF ON X X X ON OFF Step 1: Select one channel (for example ch.#1) for the initial tuning. Set the dip-switch array to "all - 4mA". Apply supply voltage to the unit. The initial state of all the output currents is 4 ma. Use SW-2 to toggle the outputs between 4 and 20mA. Step 2: Monitor all the 8 channels in 4mA state, and calibrate the Zero trimmer so that the average readings is 4.000mA. Then repeat for 20mA state, and calibrate the Span trimmer so that the average readings is 20.000mA This procedure should be repeated until calibration is satisfactory. 10

SPECIFICATIONS INPUTS: PARALLEL INPUTS: LOGIC LEVELS: DATA HOLD TIME: MAXIMUM PARALLEL INPUT RATE: SERIAL COMMUNICATION: BAUD RATES: PARITY: STOP BIT: STATUS REPORT: MULTI-DROP CAPABILITY: OUTPUTS: OUTPUT CURRENT SPAN: OUTPUT CURRENT SETTLING TIME: POWER SUPPLY: CURRENT CONSUMPTION: Parallel & Serial control inputs 3 - Output current loop address 12 - Output current value (Data) 1 - Enable (E) 0<"0"<0.4V, 3<"1"<40V 150 microsecond 6000 updates per second RS-232c full duplex RS-422 full duplex 300, 4800, 9600, 19200 bps Even One Reports as interrogated Up to eight units 8 continues current loops 0-20mA or 4-20mA (user selected) 4.2 ms max. for 99.3% of step 15-32 Vdc (regulated) 85mA max. MAXIMUM LOOP RESISTANCE: According to Rmax (Kohm)= (Vsupply -6)/20 ACCURACY: RESOLUTION: INDICATORS: ±0.1% of span typical, ±0.2% of span max. ±0.025% of span typical, ±0.05% of span max. Yellow Power-On LED 8 Red output channel LED s 11

AMBIENT TEMPERATURE: Operation: 0 to 55 C Storage: -25 to +85 C RELATIVE HUMIDITY: HOUSING: 5 to 95%, non-condensed Plastic polycarbonate BOX: According to IP 50 DIN 40050 TERMINALS: According to IP 20 DIN 40050 MOUNTING: FUSE: WEIGHT: DIMENSIONS (mm): Standard DIN rail 630mA fast blow 0.7Kg 200(W) x 73.2(H) x 121(D) data subject to change without notice 12

13