Tools required 1/8 hex wrench (provided) Phillips Screwdriver (not provided) Mounting the FMS in a Channel

Installation Guide Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

The purpose of this guide is to describe mounting of FMS, docking station, external alert device or Hotspot in channel.

Installation Guide. Universal Camera Mount Bracket

Installation Guide Philips MP20/30/40/50/60/70 IntelliVue M-Series Arm Rail Mount Kit

Installation Guide Philips MP60/70 IntelliVue VHM Arm Rail Mount Kit

GCX Mounting Assembly Operation/Installation Manual Dräger Model Primus with Siemens 6002/7000/9000XL Patient Monitors

GCX Mounting Assembly Installation Guide. Pedestal Mount for Philips IntelliVue MP5/20/30/40/50/60/70, MX400/450/500/550/600/700/800

Installation Guide GE Healthcare Solar 8000M Keypad Mounting Kit for 15'' and 18'' Flat Panel Displays

Installation Instructions. Roll Stand.

Installation Instructions. Barcode Dock Mount

EVOLVE1-M MONITOR ARM

ASSEMBLY AND ADJUSTMENT

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

Print Mechanism Maintenance Kit

Flat Panel Static Wall Mount MSP-SS (GSM-210)

Universal Desktop and Monitor Stand

Peel/Rewind Upgrade Kit

Adjustable Height Monitor (AHM) Arm

HeRO. solo/duet. Version 3.1 Customer Assembly & Maintenance Procedure

Assembly Instructions for #5630 Medication PalWOW

INSTALLATION INSTRUCTIONS YAMAHA Speaker Adapter Accessory Model: PAC-Y2

Quick Installation Guide

LARGE S URGE-PROTECTOR S HELTER

LinkStation MINI QUICK REFERENCE GUIDE

CLIMB2 DUAL MONITOR SIT/STAND WORKSTATION

Star Trac Fitness E-ST 5090 Stepper. Install Guide

Quick Installation Guide

SNOWBOARD RACK KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 25

NAV-1 Lens Support. NAV-2 Lens Support BEFORE YOU BEGIN

System Storage EXP3000 Rack Installation Instructions

CDRPanP. Installation. Instructions for Instrumentarium OP-100 FOR PANORAMIC SYSTEMS. Schick Technologies, Inc. Avenue

Ultra short throw lens installation

Quick Installation Guide

MD-BSL15W / SPRING-LOADED TWIN-ARM. For ( cm) LCD desktop computer. User Manual

A-dec 584 Monitor Mount on a Central Cabinet

Z Series and S4M Ribbon Take-Up Spindle Maintenance Kit

SCHNEIDER OPTICS INC. DISTAR PROJECTOR LENS W/ FOCUS MOUNT INSTRUCTION MANUAL

Formulate 20 Vertical Curve

Installing the Server into a Rack

CDRPan. Installation. Instructions for Siemens OP-10 FOR PANORAMIC SYSTEMS

ASSEMBLY INSTRUCTIONS, ELO SELF SERVICE STAND

Installation Instructions. Falcon IT (FIT)

ASSEMBLY ASSEMBLY INSTRUCTIONS ASSEMBLY INSTRUCTIONS

DIGITAL OBSERVATION GUARD LOW PROFILE PAN TILT KIT USER MANUAL

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Universal Tablet Mount Accessory for Flex TechBridge

D-Control Desk Module Installation Guide

G12/G12x USER S MANUAL

INSTALLATION INSTRUCTIONS

MD-BD13B / DUAL SEGMENT TWIN-ARM. For (33-69 cm) LCD desktop computer monitors. User Manual

Articulating TV/Monitor Clamp/Grommet Desk Mount Model: DE640S (Hydro Series)

Pandora Assembly Instructions With Diamond Systems PC/104 CPUs (Athena, Elektra and Prometheus) November, 2006

Extra Large Full Motion TV Mount for Televisions

If you are missing any of the following items, please contact Stanton Video immediately (602)

7403 K321. Display Wall Mount. Kit Instructions. Issue A

User Manual. Revision B

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Encore XT Manual Gun Upgrade Kit

Quad Monitor Desk Stand - 13" to 24" Installation Instructions

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)

HD NO HOLES MOUNT RAM SSV

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447

Assembly Instructions Triton Enclosure for Poseidon With Data Acquisition November, 2007 V0.9 DSC Document #

COMPLETE S YSTEM SHELTER

INSTALLATION MANUAL DATAVAULT DATAVAULT - BARE JOBSITE STORAGE SOLUTIONS

DIGITAL Server Rackmount Installation Guide

Linear Kiosk 02. features and benefits: dimensions: additional information:

Assembly Manual for Mobile X-ray

T9 EPP KEYPAD FIELD UPGRADE

Technical Communications Bulletin TCB

TX-3 TILE SAW OPERATION & PARTS MANUAL

Tile Plow Installation O Connell

A-MOD DESKTOP OWNER S MANUAL

CDRPan. Installation. Instructions for Planmeca / PM 2002 CC / EC FOR PANORAMIC SYSTEMS

Desk Stand for Dual Monitors

A-dec 586 Ceiling Monitor Mount

In-Sight 7000 Series Vision System. Optional Configurations

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

BE Series. Dual Action Ballhead. You re on steady ground

Assembly and Setup Manual

IBM. Rack Installation Instructions

WaveRider Installation

Rack Installation Instructions

Central Processing Unit (CPU) Replacement

Tailgates Conracks Sunshades

Titan Media Cart. Installation and Operation Manual

ANIxx. Installation Manual.

Power Supply, 17-inch

DUAL-ARM MONITOR MOUNT For in. ( cm) desktop computer monitors

IS-DM220/IR/HB IS-DM220

Tile Plow Installation Gold Digger

VMC Touch: Mounting Monitor Bracket Ports Connection And Cables Installation

Floor Standing Pedestal

PFPDARM3 Product Illustration

V5420 Host Card Upgrade Kit for R3082D Quick Start Guide

Service Bulletin. MiTek. RoofTracker Roof Truss Roller Press. Machinery Affected: Adding an Operator Platform. Machinery Division

How to add a Second Drive to a Mac mini (2012) using the OWC Data Doubler SSD/2.5 Installation Kit

Rear Consumer LCD Hinge Assembly Large Displays

Transcription:

3875 Cypress Drive Petaluma, CA 94954 800.228.2555 707.773.1100 Fax 707.773.1180 www.gcx.com Installation Guide Roll Stand Kit for Philips Avalon FM20/30 The purpose of this guide is to: 1. Describe attachment of Roll Stand Post to Base (page 2). 2. Describe attachment of Handle to Roll Stand Post (page 3). 3. Describe attachment of Utility Bin to Roll Stand Post (page 3). 4. Describe attachment of Mounting Adapter to monitor (page 4). 5. Describe mounting of monitor on Roll Stand Post (page 4). Parts Reference The following parts and hardware are included with this installation kit (see photos for parts; hardware not shown): Item # Description Qty 1 Roll Stand Post, 34'' with Mounting Adapters 1 2 Roll Stand Base 1 3 5/16-18 x 1'' Hex Head Cap Screw (HHCS) 1 4 5/16 Flat Washer 1 5 5/16 Split Lock Washer 1 8 1 12 6 Mounting Adapter 1 7 M4 x 10 mm Pan Head Machine Screw (PHMS) 4 8 Utility Bin 1 9 Handle 1 10 #10-32 x 9/16'' PHMS 2 11 9/64'' Hex Key 1 12 Power Supply Mount 1 2 6 9 Tools required: Phillips screwdriver (not provided), 9/64'' hex key (provided). DU-PH-0057-60 Rev B 2/21/12 GCX Corp. Page 1 of 6

Assembling the Roll Stand 1. Insert the Roll Stand Post in the Base and lay the assembly on its side for access to the bottom of the Base. 2. Using a 1/2'' [13mm] wrench, fasten Post to Base with one (1) 5/16-18 x 1'' HHCS, with 5/16 split lock washer, and 5/16'' flat washer. Roll Stand Post Roll Stand Base 5/16 Flat Washer (1) 5/16 Split Lock Washer (1) 5/16-18 x 1'' HHCS (1) DU-PH-0057-60 Rev B 2/21/12 GCX Corp. Page 2 of 6

Attaching the Handle 1. Fasten Handle to Clamping Block with two (2) #10-32 x 9/16'' PHMS as shown below. Handle #10-32 x 9/16'' PHMS (2) Clamping Block Mounting the Utility Bin 1. Slide the Mount (rear of Utility Bin) onto the Mounting Adapter and push Bin downward until the Release/Locking Tab snaps into locking position over the rear edge of the Bin. Utility Bin Mounting Adapter DU-PH-0057-60 Rev B 2/21/12 GCX Corp. Page 3 of 6

Mounting the Power Supply 1. Fasten Clamping Block with Mounting Adapter to power supply with two (2) M4 x 12 mm PHMS as shown below. Power Supply Clamping Block With Mounting Adapter (2) M4 x 12mm PHMS 2. Fasten power supply to Post with rear Clamping Block and two (2) #10-32 x 9/16'' PHMS as shown below. Rear Clamping Block (2) #10-32 x 9/16 PHMS Attaching Mounting Adapter to Monitor 1. Align four (4) mounting holes in Mounting Adapter with corresponding mounting holes on bottom of monitor. 2. Fasten Mounting Adapter to bottom of monitor with four M4 x 10mm PHMS (right). Mounting Adapter Mounting Holes (4) M4 x 10mm PHMS (4) DU-PH-0057-60 Rev B 2/21/12 GCX Corp. Page 4 of 6

Mounting the Monitor 1. Slide the Mounting Adapter (monitor attached) onto the Mounting Plate until the Adapter makes contact with the Plunger. Pull the Plunger downward and hold in position while sliding the Adapter over the Plunger (below left). Release the Plunger and continue sliding the Monitor until the Plunger snaps into the Clearance Hole on the Adapter. Tighten the Nylon screws on the bottom of the Mounting Plate (below right). Pull and Release Plunger Tighten Nylon Screws DU-PH-0057-60 Rev B 2/21/12 GCX Corp. Page 5 of 6

Routine Maintenance Periodically check all mounting hardware. Tighten as necessary for optimal operation. Adjusting Tilt Tension Periodically check tilt tension for proper operation. Adjusting Tilt Tension 1. Using the 9/64'' hex key provided, adjust tilt tension by equally tightening or loosening the two (2) Tilt Tension Screws on the Manual Tilt Clamp. Tilt Tension Screws (2) Cleaning the Mounting Assembly Caution: GCX makes no claims regarding the efficacy of the listed chemicals or processes as a means for controlling infection. Consult your hospital s infection control officer or epidemiologist. To clean or sterilize mounted instruments or accessory equipment, refer to the specific instructions delivered with those products. 1. The mounting assembly may be cleaned with most mild, non-abrasive solutions commonly used in the hospital environment (e.g. diluted bleach, ammonia, or alcohol solutions). 2. The surface finish will be permanently damaged by strong chemicals and solvents such as acetone and trichloroethylene. 3. Steel wool or other abrasive material should never be used. 4. Damage caused by the use of unapproved substances or processes will not be warranted. It is recommended that you test any cleaning solution on a small area of the mounting assembly that is not visible, to verify compatibility. DU-PH-0057-60 Rev B 2/21/12 GCX Corp. Page 6 of 6