Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Similar documents
Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.

Configuration. Installation

Siemens AG Continuous level measurement Radar transmitters. Configuration. Installation

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transducers

Level Measurement Continuous level measurement - Ultrasonic transmitters

SITRANS L Level instruments

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

Siemens AG Continuous level measurement Ultrasonic controllers

Continuous level measurement Ultrasonic transducers

Level Measurement Continuous level measurement Ultrasonic controllers

Flow Measurement SITRANS F US Inline

Quick Start Manual April English Dansk Deutsch. Español Français Italiano Nederlands Português Suomi Svenska. sitrans LG200

Quick Start Manual January sitrans LR260 (HART)

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Continuous level measurement Ultrasonic transducers

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Level Measurement Continuous level measurement Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers

Continuous level measurement Ultrasonic transducers

Flow Measurement SITRANS F US Inline

Supplementary Components WirelessHART products

Selection and Ordering data. Selection and Ordering data

Instruction Manual December sitrans LR260 (HART)

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

Continuous level measurement Ultrasonic controllers

Radar Transmitters SITRANS LR460 (HART/PROFIBUS PA) Quick Start Manual 03/2013 SITRANS

SITRANS T measuring instruments for temperature

Instruction Manual May sitrans LR400

Capacitance level switches LS 210 LS 220

Flow Measurement SITRANS F M

Radar Transmitters SITRANS LR260 (PROFIBUS PA) Operating Instructions 12/2013 SITRANS

Radar Transmitters SITRANS LR260 (PROFIBUS PA) Operating Instructions 12/2013 SITRANS

Radar Transmitters SITRANS LR260 ( PROFIBUS PA) Quick Start Manual 12/2013 SITRANS

Temperature Measurement SITRANS TS300

Flow Measurement SITRANS F M

SITRANS P measuring instruments for pressure

Disclaimer of Liability

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Radar Transmitters. SITRANS LR560 (ma/hart) Operating Instructions 12/2011 SITRANS

Disclaimer of Liability

Instruction Manual June sitrans LR460

Level limit switch Series RF 3000 Selection list. Overview 2

Spare Parts for RM71 SmartLine Guided Radar Level Meter

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Radar Transmitters SITRANS LR260 (HART) Operating Instructions 12/2013 SITRANS

Siemens AG Level Measurement

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Instruction Manual June sitrans LR250 (PROFIBUS PA)

Instruction Manual February sitrans LR250 (HART)

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Radar Transmitters SITRANS LR250 (HART) Operating Instructions 01/2012 SITRANS

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

PROFIBUS-PA Positioner Type 3785

General Specifications

Supplementary Components WirelessHART products

Product information. Radar. Level measurement in bulk solids VEGAPULS 67 VEGAPULS SR 68 VEGAPULS 68 VEGAPULS 69. Document ID: 29427

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

1 Overview. Pressure Measurement Transmitters with WirelessHART. 1/36 Siemens FI US Edition. SITRANS P280 for gauge and absolute pressure

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Flow Measurement SITRANS F C

FLEX Ex Spring Clamp Terminal Base

SITRANS F flowmeters SITRANS F US

Flow Measurement SITRANS F C

Radar Transmitters. SITRANS LR560 (ma/hart) Operating Instructions

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Flow Measurement SITRANS F US Clamp-on

Ultrasonic Transmitters SITRANS LU150. Operating Instructions

Radar Transmitters SITRANS LR200 (HART) Quick Start Manual 12/2013 SITRANS

Series 3730 Type Electropneumatic Positioner

WirelessHART Adapter SWA70

Continuous level measuring system NB 3000 Selection list

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

General Specifications

Radar Transmitters SITRANS LR250 (HART) Operating Instructions 11/2012 SITRANS

LS 6600 Technical Datasheet

DR7100 SERIES Supplementary instructions

Level-Lance Model 5400A

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Radar Transmitters SITRANS LR250 (FOUNDATION FIELDBUS) Operating Instructions. Siemens Spares

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Process Instrumentation. Ultrasonic level. Solutions for a world of applications. usa.siemens.com/level

Prosonic T FMU30. Technical Information

Guided Wave Radar Level and Interface Transmitter

BLISS ANAND. BA-Series Magnetostrictive Level Transmitter

Engineering Specifications HydroRanger 200. Multi-Functional Level Control System

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Radar Transmitters SITRANS LR200 (HART) Operating Instructions 12/2013 SITRANS

Soliphant M FTM50, FTM51, FTM52

KINAX WT720 absolute, programmable angular postion transmitter

Technical Data. General specifications. Rated operating distance s n 3 mm

Transcription:

Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels including extreme levels of dust and high temperatures, to a range of 30 m (98.4 ft). Benefits Graphical local user interface (LUI) makes operation simple with plug-and-play setup using the intuitive Quick Start Wizard LUI displays echo profiles for diagnostic support 2 GHz high frequency allows for small horn antennas mounted easily in nozzles Communication using HART or PROFIBUS PA Process Intelligence signal processing for improved measurement reliability and Auto False-Echo Suppression of fixed obstructions Programming using infrared Intrinsically Safe handheld programmer or SIMATIC PDM Emission cone Beam angle: 2" horn = 1 3" horn = 10 4" horn = 8 Application includes a graphical local user interface (LUI) that improves setup and operation using an intuitive Quick Start Wizard, and echo profile displays for diagnostic support. Startup is easy using the Quick Start wizard with a few parameters required for basic operation. Positioning with Easy Aimer s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer without having to open the instrument s lid. measures virtually any solids material to a range of 30 m (98.4 ft). Key Applications: cement powder, plastic powder/pellets, grain, flour, coal, solids bulk storage vessels, and other applications. installation, dimensions in mm (inch) /224 Siemens FI 01 2011

Technical specifications Mode of operation Measuring principle Frequency Minimum detectable distance Maximum measuring range Output-HART Power Fail signal Load Max. line length Pulse radar level measurement K-band (2.0 GHz) 0 mm (2") from end of horn 2" horn: 10 m (32.8 ft) 3" horn: 20 m (6.6 ft) 4" horn: 30 m (98.4 ft) 4... 20 ma (± 0.02 ma accuracy) Nominal 24 V DC (max. 30 V DC) 3.6 ma... 23 ma; or last value 230... 600 W, 230... 00 W when connecting a coupling module Multi-wire: 100 m (4921 ft) Protocol HART, Version.1 Output - PROFIBUS PA Per IEC 6118-2 1.0 ma Performance (according to reference conditions IEC60770- Maximum measured error (including hysteresis and non-repeatability) Rated operating conditions Installation conditions Location Ambient conditions (enclosure) Ambient temperature Installation category Pollution degree 4 Medium conditions Dielectric constant ε r Process temperature Process pressure Profile version 3.01, Class B 2 mm (1") from minimum detectable distance to 300 mm (11.8") Remainder of range = 10 mm (0.39") or 0.1 % of span (whichever is greater) Indoor/outdoor -40... +80 C (-40... +176 F) I ε r > 1.6, antenna and application dependent -40... +200 C (-40... +392 F) 0. bar g (7.2 psi g) maximum 3 bar g (43. psi g) optional with +80 C (+176 F) temperature max. Design Enclosure Construction Conduit entry Aluminium, polyester powdercoated 2 x M20x1. or 2 x ½" NPT Degree of protection Type 4X/NEMA 4X, Type 6/ NEMA 6, IP67, IP68 Weight < 8.14 kg (17.9 lb) including 4" flange and standard Easy Aimer with 4" horn antenna Display (local) Flange and horn Material Dimensions (nominal horn sizes) Process connections Universal flanges 2) Certificates and approvals General Radio Hazardous Programming Intrinsically Safe Siemens handheld programmer Approvals for handheld programmer Graphic LCD, with bar graph representing level 304 stainless steel 2" horn: 1.93" (49.0 mm) diameter 3" horn: 2.93" (74. mm) diameter 4" horn: 3.84" (97. mm) diameter 2"/0 mm, 3"/80 mm, 4"/100 mm, 6"/10 mm CSA US/C, CE, FM Europe (R&TTE), FCC, Industry Canada, C-TICK CSA/FM Class II, Div. 1, Groups E, F, G, Class III ATEX II 1D, 1/2D, 2D Ex td A20 IP67, IP68 T100 ºC Infrared receiver IS model: ATEX II 1GD Ex ia IIC T4 Ga Ex iad 20 T13 C Ta = -20... +0 C CSA/FM Class I, II, and III, Div. 1., Gr. A-G, T6 Ta=0C Handheld communicator HART communicator 37 PC Display (local) SIMATIC PDM Graphic local user interface including quick start wizard and echo profile displays From sensor reference point 2) Universal flange mates with EN 1092-1 (PN 16)/ASME B16. (10 lb)/ JIS 2220 (10K) bolt hole pattern HART is a registered trademark of the Hart Communications Foundation. Siemens FI 01 2011 /22

Selection and Ordering data 2-wire, 2 GHz pulse radar level transmitter for continuous monitoring of solids to a range of 30 m (98.4 ft). Order handheld programmer separately! Process connection Universal flat faced flange fits ANSI/DIN/JIS flanges, Easy Aimer with integral (Easy Aimer ball) 2"/0 mm A 3"/80 mm B 4"/100 mm C 6"/10 mm D Antenna 2" Horn antenna, fits 0 mm or 2" nozzles 2" Horn antenna with 100 mm extension B Order No. 2" Horn antenna with 200 mm extension C 2" Horn antenna with 00 mm extension 2) 3) D 2" Horn antenna with 1000 mm extension 2) 3) E 3" Horn antenna, fits 80 mm or 3" nozzles 4) F 3" Horn antenna with 100 mm extension 4) G 3" Horn antenna with 200 mm extension 4) H 3" Horn antenna with 00 mm extension 2) 3) 4) J 3" Horn antenna with 1000 mm extension 2) 3) 4) K 4" Horn antenna, fits 100 mm or 4" nozzles L 4" Horn antenna with 100 mm extension M 4" Horn antenna with 200 mm extension N 4" Horn antenna with 00 mm extension 2) 3) P 4" Horn antenna with 1000 mm extension 2) 3) Q Purge (Self Cleaning) Connection Maximum measurement range 10 m (32.8 ft) 2) Available with Purge connection option 0 only 3) Available with pressure option 1 only 4) Maximum measurement range 20 m (6.6 ft) C) Subject to export regulations AL: N, ECCN: EAR99 C) 7 M L 4 2 7-0 No purge connection 0 Purge connection 1 Output / Communication 777 0-7777 4... 20 ma, HART 0 PROFIBUS PA 1 Cable inlet 2 x M20x1. A 2 x ½" NPT B Note: Polymeric cable glands will be provided with M20 devices. Approvals General purpose, CSA US/C, FM, Industry Canada, FCC, CE, R&TTE, C-TICK CSA/FM Class II, Div. I, Groups E, F, G, Class III, Industry Canada, FCC, C-TICK ATEX II 1D, 1/2D, 2D T100 ºC, CE, R&TTE, C-TICK Pressure rating 3 bar g (43. psi g) pressure maximum and +80 C (+176 F) 0. bar g (7.2 psi g) maximum 1 A A B C 0 Selection and Ordering data Further designs Please add "-Z" to Order No. and specify Order code(s). Stainless steel tag [69 x 0 mm (2.71 x 1.97")]: Measuring-point number/identification (max. 16 characters); specify in plain text Test certificate: Manufacturer's test certificate M to DIN 30, Part 18 and to ISO 9000 Inspection Certificate Type 3.1 per EN 10204 Operating Instructions for HART/mA device Product shipped with plastic cable gland, rated to -20 C. If -40 C rating required, then metallic cable gland is recommended. HART is a registered trademark of HART Communication Foundation C) Subject to export regulations AL: N, ECCN: EAR99 D) Subject to export regulations AL: N, ECCN: EAR99H Order code Y1 C11 C12 Order No. English C) 7ML1998-KE01 German C) 7ML1998-KE11 Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual C) 7ML1998-KE31 This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and Operating Instructions library. Operating Instructions for PROFIBUS PA device English C) 7ML1998-KF01 German C) 7ML1998-KF31 Note: The Operating Instructions should be ordered as a separate line item on the order. Multi-language Quick Start manual C) 7ML1998-XJ81 This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and Operating Instructions library. Accessories One metallic cable gland M20x1., rated -40... +80 C (-40... +176 F), HART One metallic cable gland M20x1., rated -40... +80 C (-40... +176 F), PROFIBUS PA Handheld programmer, Infrared, Intrinsically Safe Dust cap, PTFE, for 2"/0 mm horn Dust cap, PTFE, for 3"/7 mm horn Dust cap, PTFE, for 4"/100 mm horn HART modem/rs-232 (for use with a PC and SIMATIC PDM) HART modem/usb (for use with a PC and SIMATIC PDM) SITRANS RD100 Remote display - see Chapter 8 SITRANS RD200 Remote display - see Chapter 8 SITRANS RD00 Remote display - see Chapter 8 7ML1930-1AP 7ML1930-1AQ C) 7ML1930-1BK 7ML1930-1DE 7ML1930-1BL 7ML1930-1BM D) 7MF4997-1DA D) 7MF4997-1DB /226 Siemens FI 01 2011

Characteristic curves Maximum Flange and Process Temperatures versus Allowable Ambient Temperature Ambient temperature ( C) 90 80 70 60 0 40 30 20 10 0 0 0 100 10 200 20 Process Flange SurfaceTemperature ( C) Ambient/Process Flange Surface Temperature Curve Dimensional drawings Nameplate Enclosure/electronics Optional purge connection with factory-installed 1/8 NPT plug 268 (10.6) Universal slotted flange Optional extension 100/200/00/1000 (3.93/7.87/19.68/39.37) Optional PTFE dust cap Process device tag Horn 2" Horn: 163 (6.4) 3" Horn: 228 (9.0) 4" Horn: 28 (11.2) Sensor reference point Clamp screw 49 (1.9) 74. (2.9) 97. (3.8), dimensions in mm (inch) Siemens FI 01 2011 /227

Schematics Connect the wires to the terminals as shown: the polarity is identified on the terminal block. Hand Programmer Gland Shield for HART and PROFIBUS PA Instrinsically Safe versions only. Part number: 7ML1930-1BK Notes: 1. DC terminal shall be supplied from a source providing electrical isolation between the input and output, to meet the applicable safety requirements of IEC 61010-1. 2. All field wiring must have insulation suitable for rated input voltages. 3. Use shielded twisted pair cable (14 to 22 AWG) for HART version. 4. Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes. connections /228 Siemens FI 01 2011