VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

Similar documents
Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual Pulsar Series

Installation and user manual English Français Deutsch Italiano Español Nederlands Pulsar Series

Eaton 9PX PowerPass Distribution Modules and Transformers 9PXTFMR5, 9PXPPDM2, 9PXTFMR11, and 9PXPPDM1 User's Guide

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

DS-1H05 Ethernet-over-Coax Extender. User Manual

G5 PDU Installation Guide

* * Agilent Power Distribution Unit (PDU) Installation Guide

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

EOS-6000 Series Optical A/B Switch User Manual DC Version

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Operating Instructions

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Pulsar EXtreme 2000/3000 VA

Pulsar RT RT EXB EXB RT Installation and user manual FR/AA - Page 1

NI PXI-1042 Series Power Supply Shuttle

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

CMSA-100 Manual. Cinema Media Server Automation

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

9PX :1 9PX :1 9PX :1 9PX EBM 240V. Installation and user manual ENGLISH. Copyright 2013 EATON All rights reserved.

EATON Transformer Module

MDM 011-Z1 Regen Resistor

Metro-Optical Transport Access Nodes

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 230 Volt

iconverter 2-Module Power Chassis

POWER AVAILABILITY 2U POD USER MANUAL. Power Output Distribution 120 Volt

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

MC 11 EB-2 Power supply cabinet with external bus, AC version

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

EVO-TM2A EVO-TM2B Touch Screen Monitor

JanusRAID SA-6692J Hardware User Manual

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

MODEL 805 USER MANUAL

Output Voltage* (nom.)(adjustable)

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Liebert MicroPOD 230V

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Operating instructions. Standstill monitor A / / 2011

Redundancy unit CP-A RU

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

TPC25 active crossover. user manual

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

RTU500 series Data Sheet Power Supply CP-E 24/2.5

S4112-ON Series. Setup Guide

APT20. User Manual.

LVN5200A-R2, rev. 1, Hardware Installation Guide

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

2016 SIGLENT TECHNOLOGIES CO.,LTD

Power Supply. Users Guide PRODUCT MANUAL. WESTELL.COM Westell Technologies MNL rd

HP Rackmountable 3 Phase Uninterruptible Power Systems Overview

VEP4600. Setup Guide

Hardened 10/100Base-TX IEEE802.3at PoE PSE Ethernet Extender

AMP20. User Manual.

Universal Power Supplies

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

easyraid Q24P2-U4R4 Hardware Manual

Quick Start Guide and Health and Safety Information

Broadband Automatic Disconnect Switch. User Manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

hp uninterruptible power system r12000 xr models installation instructions

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Dell Networking S4810 Open Networking (ON) Getting Started Guide

Hardened PoE Ethernet Switch

3/4 U CPCI Serial Case System

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Network Camera. Quick Guide DC-B1203X. Powered by

CPCI System Subrack 1 U

UPS READY POWER DISTRIBUTION ASSEMBLY

SmartZone Gateway- Enabled M Series Rack PDU

Dell Networking S4100-ON Series. Set-Up Guide

Pyrit 212 Sub A active subwoofer. user manual

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

Configurable Network Paging Console. Product Instructions. Model: X-NPMI

Installing the Cisco SFS 3504 Server Switch

TA18 active subwoofer. user manual

Output Voltage* (nom.)(adjustable)

MGE Galaxy kva 208 V. Installation

Sivy SA-4327S Hardware User Manual

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

icore Kiosk system Installation Guide

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

BCM2 Series Branch Circuit Monitors Quick Setup Guide

HP4 headphone amplifier. user manual

PanelView Plus/VersaView CE Terminals and Display Modules

CA846 THERMO-HYGROMETER ENGLISH. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

ENVIRONMENTAL PROTECTION

Power Input Assignment Power1 12VDC DC Jack VDC Power2 - Power Ground

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

UV Power Flood. User Manual. Order code: EQLED029

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

S5048F-ON. Set-up Guide

Preparing to Install the VG248

Room unit with PPS2 interface

Liebert GXT4 UPS, 5kVA-10kVA Intelligent, Reliable UPS Protection

Transcription:

VFI RTG PDU 6-10K Installation and user manual Service and support: Call your local service representative

SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual contains important instructions that should be followed during installation and maintenance of the PDU. The PDU models that are covered in this manual are intended for installation in an environment within 0 to 50 C, free of conductive contaminant. Certification standards Safety: EN 62040-1 EMC: IEC/EN 62040-2 Performance: IEC/EN 62040-3 IEC 61000-4-2 (ESD): level 3. IEC 61000-4-3 (Radiated field): level 3. IEC 61000-4-4 (EFT): level 4. IEC 61000-4-5 (Fast transients): level 4. IEC 61000-4-6 (Electromagnetic field): level 3. IEC 61000-4-8 (Conducted magnetic field): level 4. Special symbols The following are examples of symbols used on the PDU to alert you to the important information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol. Important instructions that must always be followed. This symbol indicates that you should not discard waste electrical or electronic equipment (WEEE) in the trash. For proper disposal, contact your local recycling/reuse or hazardous waste center. Information, advice, help. Refer to the user manual.

Safety of persons Terminal blocks may be energized even if the system is disconnected from the AC power source. Dangerous voltage levels are present within the system. It should be opened exclusively by qualified service personnel. The system must be properly grounded, always connect the earth wire first. Product safety The PDU connection instructions and operation described in the manual must be followed in the indicated order. CAUTION - To reduce the risk of fire, the unit connects only to a circuit provided with branch circuit overcurrent protection for : 63A rating, for 6kVA models, 100A rating, for 10kVA models The upstream circuit breaker for Normal AC/Bypass AC must be easily accessible. The unit can be disconnected from AC power source by opening this circuit breaker. Disconnection and overcurrent protection devices shall be provided by others for permanently connected AC input (Normal AC/Bypass AC) and AC output circuits. Check that the indications on the rating label correspond with your AC powered system and the actual electrical consumption of all the equipment to be connected to the system. For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible Never install the system near liquids or in an excessively damp environment. Never let a foreign body penetrate inside the system. Never block the ventilation grates of the system. Never expose the system to direct sunlight or source of heat. If the system must be stored prior to installation, storage must be in a dry place. The admissible storage temperature range is -25 C to +60 C. Special precautions This PDU is designed to work with UPS. All repairs and service should be performed by AUTHORIZED SERVICE PERSONNEL ONLY. There are NO USER SERVICEABLE PARTS inside the PDU.

Contents 1. Introduction... 1 1.1 Environmental protection... 1 2. Presentation... 2 3. Installation... 3 3.1 Inspecting the equipment... 3 3.2 Unpacking the Unit... 3 3.3 Checking the accessory kit... 3 3.4 Install the PDU... 4 4. AC Power cables connection... 7 4.1 AC source to PDU... 7 5. Service operation... 8 5.1 How to switch PDU to BYPASS model... 8 5.2 How to disconnect cables between PDU and UPS... 8 5.3 How to switch PDU to NORMAL model... 9 6. Specifications... 10

1. Introduction Thank you for selecting PDU to protect your electrical equipment. This PDU allows service person to service or replace the UPS without interrupting the connected loads. Besides, it also allow you apply for below extension used: Terminal block connection design enable the PDU connect to other type UPS. Rotatable rail kit design for easy service operation in a rack cabinet. Flexible position installation. We recommend that you take the time to read this manual to take full advantage of the many features of your PDU. 1.1 Environmental protection Products are developed according to an eco-design approach. Substances This product does not contain CFCs, HCFCs or asbestos. Packing To improve waste treatment and facilitate recycling, separate the various packing components. The cardboard we use comprises over 50% of recycled cardboard. Sacks and bags are made of polyethylene. Packing materials are recyclable and bear the appropriate identification symbol Materials Abbreviations Number in Polyethylene terephthalat PET 01 High-density polyethylene HDPE 02 Polyvinyl chloride PVC 03 Low-density polyethylene LDPE 04 Polypropylene PP 05 Polystyrene PS 06 1 the symbols Follow all local regulations for the disposal of packing materials. Product The product is made up of recyclable materials. Dismantling and destruction must take place in compliance with all local regulations concerning waste. At the end of its service life, the product must be transported to a processing center for electrical and electronic waste.

2. Presentation Front view: Rear view: 1. Output Breaker (Optional) 2. Output Breaker (Optional) 3. Output socket group 1 (programmable) 4. Output socket group 2 (no programmable) 5. Maintenance bypass switch 6. Maintenance switch cover 7. Input /Output terminal connected to power and load (4pole IPL, IPN, OPL, OPN. PE is screw) 8. Input switch 9. RJ11 (connect to UPS, only for RT UPS) 10. Input /Output terminal connected to UPS (4pole IPL, IPN, OPL, OPN. PE is screw) 2

3. Installation The system may be installed only by qualified electricians in accordance with applicable safety regulations. 3.1 Inspecting the equipment If any equipment has been damaged during shipment, keep the shipping cartons and packing materials for the carrier or place of purchase and file a claim for shipping damage. If you discover damage after acceptance, file a claim for concealed damage. 3.2 Unpacking the Unit Unpacking the unit in a low-temperature environment may cause condensation occurred in and on the cabinet. Do not install the unit until the inside and outside of the unit are absolutely dry (hazard of electric shock). Note: Discard or recycle the packaging in a responsible manner, or store it for future use. Packing materials must be disposed in compliance with all local regulations concerning waste. Recycling symbols are printed on the packing materials to facilitate sorting. 3.3 Checking the accessory kit Verify that the following additional items are included with the unit: RT MBP 6K RT MBP 10K Cables for UPS's Input / Output V V RJ11 cable V V Cable locker V V Ear bracket(for tower installation) V V Rail kit(for rack installation) V V User manual V V V: standard configuration 3

3.4 Install the PDU It is recommended to connect Cables for UPS's Input / Output and RJ11 cable to PDU s side before install PDU to its final location. 1. Remove the cover of terminal blocks and connect Cables for UPS's Input/ Output to terminal blocks refer to the indication on rear panel. 2. Install back the cover of terminal blocks and insert RJ11 cable. 3.4.1 Tower position installing : Assume that you already purchased our UPS and fix the UPS in tower position. 1. Our UPS provided 2 positions to install the PDU, needed additional space is as below. It is recommended to select Left position as your final installation according to the configuration length of Cables for UPS's Input / Output and RJ11 cable. Left position Top position 4

2. Install Ear bracket to PDU, then assembly PDU to UPS by M4 screws. Below pictures are examples of Left position installation. 3.4.2 Rack position installing : This PDU is flexible position installing in a rack cabinet as below. It is recommended to select Position 1 as your final installation according to the configuration length of Cables for UPS's Input / Output and RJ11 cable. Position 1(Rear of rack) Position 2(Front of rack) 5

1. Install Rail kit to rack cabinet by M5 screws and washers. 2. Slide PDU into rail kit and make sure lock PDU by the 2 clips. 3.4.3 Cables connect to UPS: 1. Connect Cables for UPS's Input/ Output to UPS s terminal blocks refer to below indication. PDU UPS 2. Insert RJ11 cable to PDU PORT on the rear of UPS. 6

4. AC Power cables connection Recommended protective devices and cable cross-sections Recommended upstream protection Model RT MBP 6K RT MBP 10K Input L, N, G Min conductor cross section Output L, N, G Min conductor cross section 4.1 AC source to PDU 6mm^2 (8AWG) 6mm^2 (8AWG) 10mm^2(6AWG) 10mm^2(6AWG) High leakage current: Earth connection essential before connecting supply. Common input/output sources connection This type of connection must be carried out by qualified electrical personnel Before carrying out any connection, check that the upstream protection devices (Normal AC source) are open "O" (Off). 1. Remove the cover of terminal block. 2. Connect the AC cable to terminal blocks refer to the indication on panel. 3. Install back the cover of terminal block. 4. You can also select Output socket group as the load connection, this PDU provide Cable locker for reliable connection of the outlet. 7

5. Service operation 5.1 How to switch system to BYPASS model 1. Remove the Maintenance switch cover, the UPS will turn to bypass mode automatically. 2. Rotate the maintenance switch to BYPASS position. Note: After switched to BYPASS position, this PDU provide a mothed of preventing 'BYPASS switch back to UPS with an unconscious operation. Please refer to Maintenance switch cover installing as above. 3. Turn the PDU s Input switch to OFF position. 4. After these operations, the PDU will power the load directly via maintenance switch. Note: please make sure the UPS is turned to bypass mode before rotate the maintenance switch to bypass position. 5.2 How to disconnect cables between PDU and UPS This is to disconnecting Cables for UPS's Input / Output and RJ11 cable. The pictures as below are examples of Rack position only. 1. Unlock the clips and push out PDU from rack cabinet, then rotate the PDU as below. 8

2. Disconnecting Cables for UPS's Input / Output and RJ11 cable as well as other cables connected on UPS. 3. Remove out the UPS for service or replacement. Note: Don t let the PDU suffer any strong stress during its rotation position. 5.3 How to switch system to NORMAL model Clarify your UPS is already complete service or replacement installation. 1. Connect Cables for UPS's Input/ Output and RJ11 cable to UPS s terminal ---refer to chapter 3.4.3 2. Turn the PDU s Input switch to ON position. The UPS will turn to bypass mode. 3. Rotate the maintenance switch to UPS position, install back the maintenance switch cover to its normal position. 4. Press on button on UPS LCD panel, the UPS will turn to line mode. 9

6. Specifications 1. Power Module model list Model RT MBP 6K RT MBP 10K Power Ratings 6000VA / 6000W 10000VA / 10000W 2. Weights and dimensions Description Weights (kg) Dimensions (mm) W x H x D RT MBP 6K 2.4 426*84.5*80 RT MBP 10K 2.4 426*84.5*80 3. Electrical input refer to the UPS input spec 4. Electrical output refer to the UPS output spec Output socket 1 10A & 16A Programmable output Output socket 2 10A & 16A Normal output 5. Electrical output connections Model Output connection Cable 6K/6KS 1. Cable for UPS & PDU 10K/10KS Hardwired connection 2. RJ11 cable 6. Environmental and safety Certifications EN 62040-1 IEC/EN 62040-2: Cat. C3 IEC/EN 62040-3 EN 60950-1 EMC (Emissions)* IEC 61000-3-2 (-3-12) IEC 61000-3-3 (-3-11) EMC (Immunity) IEC 61000-4-2, Level 3 IEC 61000-4-3, Level 3 IEC 61000-4-4, Level 4 (also on signal ports) IEC 61000-4-5, Level 4, Criteria B IEC 61000-4-6, Level 3 IEC 61000-4-8, Level 4 IEC 61000-4-11 * for output cable < 10m. 10

Agency markings Operating temperature Storage temperature Transit temperature Relative humidity Operating altitude Transit altitude CE 0~40 full load 40~50 derating to 50% 0~35 IEC socket 16A 35~40 IEC socket 10A -25 to 60 C (5 to 140 F) -25 to 55 C (-13 to 130 F) 0 to 95% no condensing Up to 3,000 meters (9,843 ft) above sea level with 10% derating per 1000m Up to 10,000 meters (32,808 ft) above sea level 614-02183-00 11