140M C 2 N A63 KN CC GJ

Similar documents
140M C 2 E A63 KN CC GJ

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

1492-SP Supplementary Protectors

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Protection Equipment

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Max. Short Circuit Current [ka] Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 600V C-Frame

Cat. No. 140M-F M-D8E-B

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

Allen-Bradley 700-K40E-DJ

Bulletin 817 Thermistor Protection Relay

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

TeSys IEC Contactors and Overload Relays

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

CS8 Industrial Control Relays

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

UL 489 DIN Rail Miniature Circuit Breakers

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

Allen-Bradley 1492-RCDA4A40

UL 489 DIN Rail Miniature Circuit Breakers

Control Circuit and Load Protection Products

Motor protection circuit breakers

Bulletin 1489 Circuit Breakers. Selection Guide

Miniature Circuit Breakers for Railway Applications

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

Motor protection relays

Complete UL/CSA Disconnect Switch Kits

Section 4 Ground-Fault Protection Devices

For Sales and Support call KMParts.com (866)

Selection Guide. Control Circuit and Load Protection

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

194E FA 32 E P11 P11 6

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

ALLEN BRADLEY RELAY Bulletin 700-HF

Electronic timer CT-ARS.11

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

60103 Circuit Breaker

Selection Guide. Control Circuit and Load Protection

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Thermal-Magnetic Circuit Breaker 2216-S

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

WEG Contactors - CWM and CWME Series

Electronic timer CT-ERS.21

Motor protection circuit breakers

TeSys contactors From 115 to 2750 A

Magnetic and Hydraulic-Magnetic Circuit Breaker

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

Product Guide. UL 1077 DIN Rail Supplementary Protectors

MOTOR PROTECTION CIRCUIT BREAKERS

Micro Contactor MA Series

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

Safety relay emergency stop/protective door, 24VDC/AC, 3 enabling paths

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MOTOR & CIRCUIT PROTECTION

Safety relay emergency stop/protective door, 24V-230VDC/AC, 3 enabling paths

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

Electronic timer CT-ERD.12

Load Feeders and Motor Starters for Use in the Control Cabinet

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Allen-Bradley Drives

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Disconnect Switches. Safe Switching and Disconnecting

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

RW-E. Overloads. Solid-State Overload Relays. Standard Features

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Miniature Circuit Breakers and Supplementary Protectors. Contents

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

Electronic timer CT-AHD.22

Switch Disconnectors, Main and EMERGENCY-STOP Switches

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

K-Line Mini - Contactors, Overload Relays and Accessories

Time Delay Values (E-Series)

Switching relay CT-IRE with 1 c/o (SPDT) contact

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Cat. No. (Spring Clamp. Input Voltage

Transcription:

Motor Circuit Protectors Product Overview/Catalog Number Explanation Product Line Overview C-Frame D-Frame F-Frame H-Frame J-Frame L-Frame N-Frame Max. Current I e A A A 00 A 0 A 00 A 00 A Current Rating 0.. A. A A 00 0 0 00 0 00 Short Circuit Protection Standards Compliance: CSA., No. CSA., No. UL 0 (Group Install.) UL (Recognized) IEC 0- CE CCC (up to A) Accessories Ext. Rotary Operator Flex Cable Operator Auxiliary Contacts Trip Indication Contacts Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations will produce a valid catalog number. Code 0M Code C D F H J L N a Bulletin Number Description Motor Circuit Protectors (MCPs) b Frame Size and Rating Description A A A A 0 A 00 A and 00 A 00 A and 00 A Interrupting Rating / Breaking Capacity (I c at 0V) Code Description Normal Break High Break c 0M C N A KN CC GJ a b c d e f g h Code e Current Range Code Description Example A A =.0 A = 0. B B =.0 B =. C C = 0 C = D D = 00 D = 0 E E = 000 E = 00 d Protection Type Description N Fixed Mag Only ( x I n ) P R Adj Mag Only (less than x I n ) - MCPs Adj Mag Only (greater than x I n ) - MCP's f, g, h Factory-Installed Options f Miscellaneous See page - g Aux/Trip Contacts See page - h UV and Shunt Trips See page - 0 Publication A-CA00A-EN-P -

Motor Circuit Protectors Product Overview Motor Circuit Protectors Current range 0. 00 A UL Listed/Recognized for motor loads Short-circuit protection Overload protection must be provided separately Visible trip indication High current limiting High switching capacity The Motor Circuit Protectors provide short circuit protection for individual motor loads. Factory-installed internal accessories make installation and wiring easy. Certifications (0. A) CE Marked culus Listed (File No. E, Guide No. NLRV, NLRV) CCC Certifications ( 00 A) UR Recognized component (File No. E, Guide DKPU) CSA Certified (Cleass No. -0) Table of Contents Product Selection Motor Circuit Protectors... - Approximate Dimensions... - Standards Compliance IEC/EN 0-,, --, -- IEC/EN 00- CSA, C. No. UL 0 UL (H-, J-, L-, N-Frame) General Information Motor Circuit Protectors may provide the following protective and control functions. Disconnect for Motor Branch Circuit Branch-Circuit, Short-Circuit Protection (Magnetic Protection) Switching (Manual) In North America, electrical codes require that an individual Motor Branch Circuit be protected by a UL/CSA Listed Fuse, Circuit Breaker or Self-Protected Combination Motor Controller. 0M-C, D and F Frames: The 0M-C, D and F frame Motor Circuit Protectors have one UL/CSA Listing as Manual Motor Controllers (with optional approvals for Motor Disconnect and Group Installation). In NEC/CEC Group Installations, these devices must be applied per the appropriate rules which require the use of an upstream Branch-Circuit, Short-Circuit Protective Device (BCPD). See the table on page -0 for the specific ratings of each Motor Circuit Protector. The 0M-C, D and F Frame Motor Circuit Protectors are also UL/CSA Listed, together with a Bulletin 00C contactor and Bulletin overload relay, as part of our Bulletin 0T and 0T Self-Protected IEC Combination Starters. These starters are then able to provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices. 0M-H, J and L Frames: The 0M-H, J and L frame Motor Circuit Protectors are UL/CSA Recognized as Circuit Breakers as shown in the table on page -0. They are UL/CSA Recognized, rather than UL/CSA Listed, since they only provide short circuit protection and not thermal overload protection for the motor. 0M-H, J and L frame Motor Circuit Protectors (MCPs) are also UL/CSA Listed, together with a Bulletin 00C contactor and Bulletin overload relay, as part of our Bulletin IEC Combination Starters. These starters are then able to provide all of the necessary NEC/CEC requirements for the protection and control of individual Motor Branch Circuits without additional protective devices. 0 - Publication A-CA00A-EN-P

IEC Performance Data, Continued Cat. No. 0M-CN- A A A0 A B0 B B Rated Operational Current, I e [A] 0. 0. 0. 0... Magnetic Release Current [A].... Switching of Standard Three-Phase Motors AC- 0/0V [kw] 0.0 0.0 0. 0. 0. 00/V [kw] 0.0 0.0 0.0 0. 0. 0. 0. 00V [kw] 0.0 0.0 0. 0. 0. 0.. 0V [kw] 0.0 0.0 0. 0. 0... Back-Up Fuses gg, gl, only if I cc I cu 0/0V [A] 00/V [A] 0/0V [A] 00V [A] 0V [A] 0 Ultimate Short Circuit Breaking Capacity I cu 0/0V [ka] 00 00 00 00 00 00 00 00/V [ka] 00 00 00 00 00 00 00 0/0V [ka] 00 00 00 00 00 00 00 00V [ka] 00 00 00 00 00 00 00 0V [ka] 00 00 00 00 00 0 Rated Service Short Circuit Breaking Capacity I cs 0/0V [ka] 00 00 00 00 00 00 00 00/V [ka] 00 00 00 00 00 00 00 0/0V [ka] 00 00 00 00 00 00 00 00V [ka] 00 00 00 00 00 00 00 0V [ka] 00 00 00 00 00 No back-up fuse required. 0 Publication A-CA00A-EN-P -

IEC Performance Data, Continued Cat. No. 0M-DN- Cat. No. 0M-FN- B B0 B C0 C C C C C C Rated Operational Current, I e [A]..0. 0 Magnetic Release Current [A] 0 0 Switching of Standard Three-Phase Motors AC- 0/0V [kw] 0. 0....0.... 00/V [kw] 0....0. 00V [kw]...0. 0 0 0 0 0V [kw]..0.0. 0 0 Back-Up Fuses gg, gl, only if I cc I cu 0/0V [A] 00 00/V [A] 00 00 0/0V [A] 0 00 00 00V [A] 0 0 00 00 0V [A] 0 0 0 0 0 00 00 Ultimate Short Circuit Breaking Capacity I cu 0/0V [ka] 00 00 00 00 00 00 00 00 00 00/V [ka] 00 00 00 00 00 0 00 0/0V [ka] 00 00 00 00 0 0 0 00V [ka] 00 00 00 00 0 0 0 0 0V [ka] 0 0 0 0 0 0 Rated Service Short Circuit Breaking Capacity I cs 0/0V [ka] 00 00 00 00 00 00 0 00 00 00 00/V [ka] 00 00 00 00 0 0 0 0 0/0V [ka] 00 00 00 00 0 0 0 0 0 00V [ka] 00 00 00 00 0 0 0 0 0 0V [ka] 0 0 0 0 No back-up fuse required. 0 - Publication A-CA00A-EN-P

IEC Performance Data, Continued Cat. No. 0M-CT- A A A0 A B0 B B B0 B C0 C Rated Operational Current, I e [A] 0. 0. 0.0 0..0...0. 0 Magnetic Release Current [A]... 0 0 0 Switching of Standard Three-Phase Motors AC- 0/0V [kw] 0.0 0.0 0. 0. 0. 0....0 00/V [kw] 0.0 0.0 0.0 0. 0. 0. 0....0. 00V [kw] 0.0 0.0 0. 0. 0. 0....0. 0 0V [kw] 0.0 0.0 0. 0. 0....0.0. Back-Up Fuses gg, gl, only if I cc I cu 0/0V [A] 00/V [A] 0 0/0V [A] 0 00V [A] 0 0 0V [A] 0 0 0 Ultimate Short Circuit Breaking Capacity I cu 0/0V [ka] 00 00 00 00 00 00 00 00 00 00 00 00/V [ka] 00 00 00 00 00 00 00 00 00 00 0 0/0V [ka] 00 00 00 00 00 00 00 00 00 0 0 00V [ka] 00 00 00 00 00 00 00 00 00 0 0 0V [ka] 00 00 00 00 00 Rated Service Short Circuit Breaking Capacity I cs 0/0V [ka] 00 00 00 00 00 00 00 00 00 00 00 00/V [ka] 00 00 00 00 00 00 00 00 00 00 0/0V [ka] 00 00 00 00 00 00 00 00 00 0 00V [ka] 00 00 00 00 00 00 00 00 00 0 0V [ka] 00 00 00 00 00 No back-up fuse required. 0 Publication A-CA00A-EN-P -

IEC Performance Data, Continued Cat. No. 0M-DT- Cat. No. 0M-FT- C C0 C C Rated Operational Current, I e [A] 0 Magnetic Release Current [A] 0 Switching of Standard Three-Phase Motors AC- 0/0V [kw].0... 00/V [kw]. 0 00V [kw] 0 0 0V [kw] 0 Back-up fuses gg, gl,, only if I cc I cu 0/0V [A] 00/V [A] 0 00 00 0/0V [A] 0 00 00 00V [A] 0 0 00 0V [A] 0 00 Ultimate short-circuit breaking capacity I cu 0/0V [ka] 00 00 00 00 00/V [ka] 00 0/0V [ka] 0 00V [ka] 0 0 0 0V [ka] 0 0 Rated service short-circuit breaking capacity I cs I cs 0/0V [ka] 00 00 00 00 00/V [ka] 0 0 0/0V [ka] 0 0 00V [ka] 0 0 0V [ka] No back-up fuse required. Consult your local Rockwell Automation sales office or Allen-Bradley distributor. 0 - Publication A-CA00A-EN-P

General Data Rated Insulation Voltage U i Cat. No. 0M-C 0M-D 0M-F 0-CMN IEC, SEV, VDE 00 [V] 0 0 UL, CSA [V] 00 00 Rated Impulse Withstand Voltage U imp Pollution degree Main circuits U imp /Overvoltage Category kv/iii kv/iii Auxiliary circuits U imp /Overvoltage Category kv/iii kv/iii Rated Frequency [Hz] 0/0 0 0 Utilization Category IEC 0- (Circuit breaker) A A IEC 0-- (Motor starter) AC- AC- Life Span Mechanical [operations] 00 000 0 000 0 000 Electrical (I e max.) [operations] 00 000 0 000 0 000 (up to A) 000 (up to 0 A) Switching Frequency [operations/h] max. max. 0 Ambient Temperature Storage [ C] -0 +0 - +0 Operation [ C] - +0 Climatic resistance Moisture change climate (000--0) C / % relative humidity and 0 C / % relative humidity, cycles Dry heat (00--) 00 C, relative humidity <0 %, days Moisture heat (00--) 0 C, relative humidity %, days Site Altitude [m] to 000 N.N. Protection Class IPX, when wired Resistance to Shock, Transport (00--) 0 g, ms, all axes 0, ms Resistance to Vibration, Opertion (00--) g Rated Thermal Current I th up to 0 C ambient temperature [A] 0... 0 up to 0 C ambient temperature [A] 0... 0 Rated Supply Current I e [A] 0... 0 Dependence on Temperature 0 C [A] no reduction 0 C [A] no reduction 0 C [A] no reduction 0 C [A] % current reduction of the upper rated current I e Overload Protection Characteristics IEC 0-- Motor protection (except Cat. Nos. 0M-CN, 0M-DN, 0M-FN) IEC 0 Ambient Temperature Compensation [ C] -0 +0 Phase-loss Protection Differential release Trip class 0 (except Cat. Nos. 0M-CN, 0M-DN, 0M-FN) fixed setting 0 Magnetic Release Release current (+/-0 %) fixed setting x I e max. (for 0M-CE, 0M-DE, 0M-FE, 0M-CN, 0M-DN, 0M-FN) x I e max. (for 0M-CT, 0M-DT, 0M-FT) I e max. = maximum values of setting ranges fixed setting x I e max. Total Power loss P v Circuit Breaker at rated load operating temperature [W].. Main Disconnect Switch Application Yes, with accessories For utilization outside North America, assemblies (of products) shall comply to the IEC - requirements Application Conditions 0M manual motor starters are intended for use in closed areas without hazardous operating conditions such as dust or explosive or corrosive gases. Enclosures of appropriate manner need to be in place to protect devices in such environments. 0 Publication A-CA00A-EN-P -

General Data, Continued Conformity to Standards Cat. No. 0M-C 0M-D 0M-F 0-CMN IEC 0-; -; --; EN 0-; -; --; UL 0; CSA., No. IEC 0-; -; EN 0-; -; UL 0; CSA., No. Approvals CE, UL, CSA CE, UL, CSA Terminal Parts Type of terminals Screwdriver Pozidriv No. /Blade No. Pozidriv No. /Blade No.. conductor. conductor. conductor. conductor. conductor. conductor. conductor. conductor [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] /No. 0 /No. 0 /No. 0 /No. 0. /No.. /No. /No. 0 /No. 0. /No.. /No.. /No.. /No. /No. /No.. 0/No.. 0/No... 0 / 0 / Tightening torque [Nm]/[lb in]././ 0 0/ 0 Screwless Cat. No. 0M-RC 0 Terminal Parts Type of terminals Screwdriver. conductor. conductor. conductor. conductor. conductor. conductor Accessories for Motor Protection Circuit Breakers Rated Thermal Current I th at 0 C ambient temperature at 0 C ambient temperature Contact Class Coordination According to NEMA (UL/CSA Standards) [A] [A] AC DC Auxiliary Contact Blocks for Front Mounting Cat. No. 0M-C-AFA, 0M-C-AFAR B 00 Q 00 Auxiliary Contact Blocks for Right-Side Mounting Cat. No. 0M-C-ASA, 0M-C-ASAR Back-Up Fuses gg, gl [A] 0 0 Rated Supply Current [V] 0 0 0 0 0 AC- [A]. 0. DC- [V] 0 0 0 0 [A] 0. 0. 0. 0. 0. Terminal Parts Type of terminals Screwdriver Pozidriv No. /Blade No.. conductor. conductor. conductor. conductor. conductor. conductor [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm]/[awg] [mm]/[awg] [mm]/[awg] [mm]/[awg] [mm]/[awg] [mm]/[awg] 0. 0. 0../ 0../ 0../No. 0../No. /No. /No. 0../ 0../ 0../ 0../ 0../ 0../ 0 B 00 Q 00 0../ 0../ 0../ 0../ 0../ 0../ Tightening torque [N m]/[lb in]../0.../0.. - Publication A-CA00A-EN-P

Accessories for Motor Protection Circuit Breakers, Continued Actuating Voltage Pull-in Drop-out Rated Control Voltage min. max. Undervoltage Trip for Left-Side Mounting Cat. No. 0M-C-UX 0.. x U s 0. 0. x U s V 0 Hz, V 0 Hz 00V 0 Hz Undervoltage Trip with Auxiliary Contacts for Left-Side Mounting Cat. No. 0M-C-UC 0.. x U s 0. 0. x U s V 0 Hz, V 0 Hz 00V 0 Hz Shunt Trip for Left-Side Mounting Cat. No. 0M-C-SN 0.. x U s V 0 Hz, V 0 Hz 00V 0 Hz On-Time 00% 00% 00% Coil Rating Pull-in Hold. VA, W VA, W. VA, W VA, W. VA, W VA, W Terminal Parts Type of terminals Screwdriver Pozidriv No. /Blade No.. conductor. conductor. conductor. conductor. conductor. conductor [mm]/[awg] [mm]/[awg] [mm]/[awg] [mm]/[awg] [mm]/[awg] [mm]/[awg] 0../No. 0../No. 0../No. 0../No. 0../No. 0../No. Tightening torque [N m]/[lb in]../0.. Rated Thermal Current I th at 0 C ambient temperature Compact Busbar Feeder Terminal Compact Busbar Compact Busbar Feeder Block 0M-C-WTN 0M-C-WTEN 0M-F-WTE 0M-C -W 0M-F -W 0M-C-WBE L, L, L 0M-C-WBE T, T, T 0M-F-WBE L, L, L 0M-F-WBE T, T, T [A] 0 0 IEC 0/UL for use with. conductor [mm]/[awg]. / /0 0M-C-W 0/0 for use with 0M-F-W. conductor [mm]/[awg]. / 0/ /0 /0 for use with 0M-C-W /0 for use with 0M-F-W. conductor [mm]/[awg]. /. 0/ /0. / for use with 0M-C-W. / for use with 0M-F-W Tightening torque [N m]/[lb in]./ /./. / / Accessories for Screwless Cat. No. 0M-RC Terminal Parts Type of terminals Screwdriver.. conductor. conductor. conductor. conductor. conductor. conductor [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] [mm ]/[AWG] 0. 0. 0../ 0../ 0../No. 0../No. 0../No. 0../No. 0 Publication A-CA00A-EN-P -

0 Weights Description Weight [g] Cat.No. 0M-CE- 0M-DE- 0M-FE- 0M-CN- Motor Protection Circuit Breakers 0M-DN- 0M-FN- 0M-CT- 0M-DT- 0M-FT- 0-CMN- 0M-C-AFA0 0M-C-AFA0 0 0M-C-AFA 0M-C-AFA0 Auxiliary Contacts 0M-C-ASA 0M-C-AFAR0A 0M-C-ASAR M 0M-C-ASAM 0-CA 0 0M-C-UX Undervoltage Trip 0 0M-C-SN 0M-C-UC 0-CUV Trip Contact Blocks 0-CT Shunt Trip 0-CRT ` Weight [g] Cat.No. Anti-Tamper Cover 0M-C-CA Lockable Twist Knob 0M-C-KN 0M-C-KRY Locking Tag 0 0M-C-M Door Coupling Handle 0M-C-DN 0M-C-NRY Extension Shaft 0M-C-DS Legend Plate 0M-C-DFC Feeder Terminal 0M-C-WTEN 0M-F-WT 0M-C-WN 0M-C-WN 0M-C-WN Compact Busbars 0 0M-C-WN 0 0M-C-WN 0M-C-WN 0 0M-C-WN 0 0M-C-WN Top Hat Rail Adpapter 0-KBH - Publication A-CA00A-EN-P

Accessories for Bulletin 0-CMN Circuit Breakers Rated Thermal Current I th up to 0 C ambient temperature up to 0 C ambient temperature NEMA contact class (UL/CSA-Approval) [A] [A] AC DC Cat. No. 0-CT Trip Contact Block for Flush Mounting on Cat. No. 0-CMN Circuit Breakers 0 B 00 Standard Pilot Duty R 00 Light Pilot Duty Cat. No. 0-CRT, 0-CUV Undervoltage Trip and Shunt Trip for Flush Mounting on Cat. No. 0-CMN Circuit Breakers Make/Break max. voltage VA VA0 V VA VA0 V Back-Up Fuse gg, gl A A Rated Current I e AC-: DC-: [V] [A] [V] [A] 0 00. 0. 00. 0 0. 0 0. 0 0. 0 0.0 AC-: DC :.. 0. 0. 0.0 0 0. 00.0 0 0. 00 0. Terminals Screwdriver.conduct or.conduct or.conduct or.conduct or [mm]/[awg] [mm]/[awg] [mm]/[awg] [mm]/[awg] 0../No. 0../No. 0../No. 0../No. 0../No. 0../No. 0../No. 0../No. Tightening torque [N m]/[lb in]./. 0../. 0. Operating Voltage Cat. No. 0-CUV Undervoltage Trip Unit for Right-Side Mounting on Cat. No. 0-CMN Circuit Breakers Cat. No. 0-CRT... Shunt Trip for Flush Mounting on Cat. No. 0-CMN Circuit Breakers Pick-up 0.. x U s 0.. x U s Drop-out 0. 0. x U s Duty cycle 00 % ED 00 % ED Control Voltage min. V 0 Hz/ V 0 Hz V 0 Hz/ V 0 Hz max. 00 V 0 Hz 00 V 0 Hz Coil Performance Pick-up Drop-out [VA/W] [VA/W] / / / / Terminals Terminal type Fine-stranded [mm] x 0.. x 0.. 0 Coarse-stranded [mm] x 0.. x 0.. Tightening torque [Nm].. Coarse-stranded [AWG] No.. No.. Tightening torque [lb in]. 0.. 0. Publication A-CA00A-EN-P -

Cut-off current Î s I cc asymmetrical I D I cc symmetrical The Bulletin 0-M limits solid short-circuit current I CC (prospective short-circuit current). I D is the maximum cut-off current (highest instantaneous value of the limited short-circuit current). This value is indicated in the following diagrams as a function of the progressive system short-circuit current. -C Circuit Breaker (Maximum Cut-Off Current) 00 0M-CE, -CN, -CT Max. Cut-Off Current, U e = 00 V 0. 0. 0. Peak current [ka] 0 0. 0. 0. 0. / A A 0 A A 0 A. A.0 A. A cos φ.0 A 0. 0. 0 00 Prospective current [ka r.m.s] 0-0 Publication A-CA00A-EN-P

-D Circuit Breaker (Maximum Cut-Off Current) 0M-DE, -DN, -DT Max. Cut-Off Current, U e = 00 V 00 0. 0. Peak current [ka] 0 0. 0. 0. 0. / A A / 0 A 0 A. A.0 A cos φ 0.. A 0. 0. 0 00 Prospective current [ka r.m.s] -F Circuit Breaker (Maximum Cut-Off Current) 0M-FE, -FN, -FT Max. Cut-Off Current, U e = 00 V 00 0. 0. Peak current [ka] 0 0. 0. 0. 0. 0. A / A 0 A A 0 A 0 cos φ 0. 0. 0 00 Prospective current [ka r.m.s] Publication A-CA00A-EN-P -

-C Circuit Breaker (Maximum Let-Through-Energy).00E+0 0M-CE, -CN, -CT Max. Let-Through-Energy, U e = 00 V Half-Cycle (0Hz) Let-through energy [A s].00e+0.00e+0.00e+0 / A A 0 A A 0 A. A.0 A. A. A.00E+0 0. 0 00 Prospective current [ka r.m.s] -D Circuit Breaker (Maximum Let-Through-Energy) 0M-DE, -DN, -DT Max. Let-Through-Energy, U e = 00 V.00E+0 0 Let-through energy [A s].00e+0.00e+0 Half-Cycle (0Hz) A A A 0 / A 0 A. A.0 A.00E+0. A.00E+0 0. 0 00 Prospective current [ka r.m.s] - Publication A-CA00A-EN-P

-F Circuit Breaker (Maximum Let-Through-Energy) 0M-FE, -FN, -FT Max. Let-Through-Energy, U e = 00 V.00E+0 Let-through energy [A s].00e+0.00e+0 Half-Cycle (0Hz) A A A 0 A A 0 A.00E+0.00E+0 0. 0 00 Prospective current [ka r.m.s] Time-Current Characteristic -C, -D, -F Motor Protection Circuit Breakers 0 000 h 000 Bulletin 0-CMN Motor Protector 00 0 Release Time [s] 0. Tripping time [s] 0.0 0.00 0. 0 0 0 0 00 Multiple of the set current I ef Multiple of set current I e F ) Thermal Release Trip Current The adjustable current-dependent delayed bimetal release protects motors against overload. The curve shows the mean operating current at an ambient temperature of 0 C starting from the cold state. Careful testing and setting ensures effective motor protection even in the case of single-phasing. The overload characteristic is also valid for transformer protection. ) Magnetic Release Trip Current The instantaneous magnetic trip has a fixed operating current setting. This corresponds to times the maximum value of setting range. (Transformer protection up to 0 x I e max.) At a lower setting it is correspondingly higher. Current Setting I ef The overload trip corresponds to a thermal overload relay in a motor starter conforming to IEC--. If a different value is prescribed (e.g., reduced I e for cooling medium having a temperature higher than 0 C or a place of installation higher than 000 m above sea level), the setting current is equal to the reduced rated current I e of the motor. 0 Publication A-CA00A-EN-P -

Approximate Dimensions Cat. No. 0M-C, -D, -F Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Cat. No. 0M-C Cat. No. 0M-D 0 Mounting on mm DIN Rail Undervoltage/shunt trip Auxiliary contact (front mounted) Auxiliary contact (side mounted) - Publication A-CA00A-EN-P

Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Cat. No. 0M-F Mounting on mm DIN Rail Undervoltage/shunt trip Auxiliary contact (front mounted) Auxiliary contact (side mounted) Cat. No. 0M-RC, Screwless Cat. No. 0M-RC 0 Mounting on mm DIN Rail Undervoltage/shunt trip Auxiliary contact (front mounted) Auxiliary contact (side mounted) Publication A-CA00A-EN-P -

Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Cat. No. 0M-C/D Cat. No. 0M-F 0 0 0 0 Minimum distance to grounded parts or walls Mounting position/safety clearance of Cat. No. 0M-C, 0M-D, 0M-F Cat. No. 0M-C-TE Type E adapter on Cat. No. 0M-CE Cat. No. 0M-C-TE Type E adapter on Cat. No. 0M-DE 0 Cat. No. 0M-C-TE Type E adapter on Cat. No. 0M-FE - Publication A-CA00A-EN-P

Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes.... Screw Adapter 0M-C-N for 0M-C/D and 0M-F Compact Busbar Feeder Terminal IEC Compact Busbar Feeder Terminal UL type E and IEC Mounting on mm DIN Rail Top Hat Rail Adapter 0 mm Cat. No. 0M-C with Busbar 0 Publication A-CA00A-EN-P -

Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes..... min. 00.... b.. a 0M-C-DSL 0M-C-DS + mm.... c c + mm. 0M-C-D With Cat. No. 0-M-C-DS Shaft Cat. No. a b c c 0M-C 0. ±. 0. 0M-D. ±. 0. 0M-F... ±. 0. With Cat. No. 0-M-C-DSL Shaft Cat. No. a b c c 0M-C 0. ±. 0. 0M-D. ±. 0. 0M-F.. ±. 0. 0 - Publication A-CA00A-EN-P

Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. 0M-C-WBE Cat. No. E Ø Ø Ø 0 E-AYT Publication A-CA00A-EN-P -

Approximate Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Cat. No. 0-CMN 0-CMN 0 0 0 0 0 (0.) ± (0.). (0.0 0.) min. 00 (.). (.).. (..) 0 0 (.0 0.) (.). (.0) ± (0.). (.0) (0. 0.) 0 Mounting position/safety clearance of Cat. No. 0-CMN 0 0-CD Note: See Bulletin 0U-H, J, L and N for dimensions of 0M-H, J, L and N frames. -0 Publication A-CA00A-EN-P