sheet minirite Speech Understanding Sound Quality Listening Comfort Personalization & Optimizing Fitting Connecting to the World Oticon Opn S 1 Oticon Opn S 2 Oticon Opn S 3 OpenSound Navigator Level 1 Level 2 Level 3 - Balancing power effect 1% 5% 5% - Max. noise removal 9 5 3 OpenSound Optimizer Speech Guard LX Level 1 Level 2 Level 3 Spatial Sound LX 4 estimators 2 estimators 2 estimators Soft Speech Booster LX Speech Rescue LX Clear Dynamics - Spatial Noise Management - Fitting Bandwidth* 1 KHz 8 KHz 8 KHz Processing Channels 64 48 48 Bass Boost (streaming) Transient Noise Management 4 configurations On/Off On/Off Feedback shield LX Wind Noise Management YouMatic LX 3 configurations 2 configurations 1 configuration Fitting Bands 16 14 12 Multiple Directionality Options Adaptation Management Oticon Firmware Updater Fitting Formulas VAC+, NAL-NL1 + 2, DSL v5. VAC+, NAL-NL1 + 2, DSL v5. VAC+, NAL-NL1 + 2, DSL v5. Stereo streaming (2.4 GHz) Oticon ON App ConnectClip Remote Control 3. TV Adapter 3. Phone Adapter 2. Oticon Opn S minirite offers discreet design with 312 battery and single push button. OpenSound Navigator helps users to select and understand speech in all types of environments by balancing the sound sources and attenuating noise. OpenSound Optimizer improves users listening experience and comfort by blocking feedback and securing the targeted amplification of sound sources. TwinLink wireless technology combines binaural communication and 2.4 GHz connectivity with stereo streaming directly from digital devices. Oticon Opn S is built on the powerful Velox S platform which has a programmable firmware architecture, supporting future performance updates. Tinnitus SoundSupport * Bandwidth accessible for gain adjustments during fitting Operating conditions Temperature: +1 C to +4 C Relative humidity: 5% to 93%, non-condensing Storage and transportation conditions Temperature and humidity should not exceed the following limits for extended periods during transportation and storage. Temperature: -25 C to +6 C Relative humidity: 5% to 93%, non-condensing For information on compatibility, please visit www.oticon.ca/connectivity
Oticon Opn S 1 minirite 6 Oticon Opn S 2 & 3 minirite 6 1 2 3 4 5 6 7 8 9 1 11 12 125 25 5 1k 2k 4k 8k Hz 11 1 9 8 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE6_OSPL9_711 26 9 216 taje 1:59: 11 1 9 8 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE6_OSPL9_2cc 26 9 216 taje 1:58:38 1 2 3 4 5 6 7 8 9 1 11 12 125 25 5 1k 2k 4k 8k Hz 11 1 9 8 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE6_OSPL9_711 26 9 216 taje 12:8:54 11 1 9 8 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE6_OSPL9_2cc 26 9 216 taje 12:9:14 4 3 2 1 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE6_FOG_711 26 9 216 taje 1:59:57 4 3 2 1 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE6_FOG_2cc 26 9 216 taje 1:59:35 4 3 2 1 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE6_FOG_711 26 9 216 taje 12:1:1 4 3 2 1 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE6_FOG_2cc 26 9 216 taje 12:1:25 1 9 8 7 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE6_freqResp_711 26 9 216 taje 11:1:14 1 9 8 7 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE6_freqResp_2cc 26 9 216 taje 11::59 1 9 8 7 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE6_freqResp_711 26 9 216 taje 12:11:17 1 9 8 7 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE6_freqResp_2cc 26 9 216 taje 12:11:32 OSPL9 Peak 116 15 16 Hz 19 1 HFA-OSPL9 11 12 Full-on gain 1 16 Hz 37 29 Peak 46 35 HFA-FOG 38 3 Reference test gain 3 26 Frequency range 11-97 Hz 1-92 Hz Telecoil output (16 Hz) (Input 7 ) 5 Hz <2 % <2 % 8 Hz <3 % <2 % 16 Hz <2 % <2 % Omni 21 18 Dir 28 27 Battery consumption 2 Typical 1.5 ma 1.6 ma Battery life, artificial measurement, hours 3 12 115 Expected battery life, hours (battery size 312 - IEC PR41) 4 6-65 IRIL (IEC 6118-13:211) 8/14/2 MHz: 21/<2/<2 OSPL9 Peak 116 15 16 Hz 19 1 HFA-OSPL9 11 12 Full-on gain 1 16 Hz 37 29 Peak 46 35 HFA-FOG 38 3 Reference test gain 3 26 Frequency range 11-75 Hz 1-75 Hz Telecoil output (16 Hz) (Input 7 ) 5 Hz <2 % <2 % 8 Hz <3 % <2 % 16 Hz <2 % <2 % Omni 22 19 Dir 3 28 Battery consumption 2 Typical 1.5 ma 1.6 ma Battery life, artificial measurement, hours 3 12 115 Expected battery life, hours (battery size 312 - IEC PR41) 4 6-65 IRIL (IEC 6118-13:211) 8/14/2 MHz: 21/<2/<2 1) Measured with the gain control of the hearing aid set to its full-on position minus 2 and with an input SPL of 7. This is to obtain a gain response equal to the full-on gain response from e.g. IEC 6118-+A1:1994 but without influence of feedback. 2) Battery current is measured according to IEC 6118-:1983/AMD1:1994 7.11, IEC 6118-:215 7.7 and ANSI S3.22:214 6.13 after a settling time of minimum 3 minutes. 3) Based on the standardized battery consumption measurement (IEC 6118-:1983/AMD1:1994). The actual battery life depends on battery quality, use pattern, active feature set, hearing loss 1) Measured with the gain control of the hearing aid set to its full-on position minus 2 and with an input SPL of 7. This is to obtain a gain response equal to the full-on gain response from e.g. IEC 6118-+A1:1994 but without influence of feedback. 2) Battery current is measured according to IEC 6118-:1983/AMD1:1994 7.11, IEC 6118-:215 7.7 and ANSI S3.22:214 6.13 after a settling time of minimum 3 minutes. 3) Based on the standardized battery consumption measurement (IEC 6118-:1983/AMD1:1994). The actual battery life depends on battery quality, use pattern, active feature set, hearing loss
minirite 85 minirite 85 Oticon Opn S 1 Oticon Opn S 2 & 3 1 2 3 4 5 6 7 8 9 1 11 12 125 25 5 1k 2k 4k 8k Hz 12 11 1 9 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE85_OSPL9_711 26 9 216 taje 11:5:54 12 11 1 9 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE85_OSPL9_2cc 26 9 216 taje 11:5:35 1 2 3 4 5 6 7 8 9 1 11 12 125 25 5 1k 2k 4k 8k Hz 12 11 1 9 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE85_OSPL9_711 27 9 216 taje 13:23: 12 11 1 9 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE85_OSPL9_2cc 27 9 216 taje 13:23:2 6 5 4 3 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE85_FOG_711 26 9 216 taje 11:6:46 6 5 4 3 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE85_FOG_2cc 26 9 216 taje 11:6:26 6 5 4 3 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE85_FOG_711 27 9 216 taje 13:24:8 6 5 4 3 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE85_FOG_2cc 27 9 216 taje 13:24:28 11 1 9 8 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE85_freqResp_711 26 9 216 taje 11:7:36 11 1 9 8 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE85_freqResp_2cc 26 9 216 taje 11:7:2 11 1 9 8 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE85_freqResp_711 27 9 216 taje 13:25:13 11 1 9 8 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE85_freqResp_2cc 27 9 216 taje 13:25:29 OSPL9 Peak 127 116 16 Hz 12 111 HFA-OSPL9 121 112 Full-on gain 1 16 Hz 52 43 Peak 66 54 HFA-FOG 55 47 Reference test gain 45 34 Frequency range 12-95 Hz 1-85 Hz Telecoil output (16 Hz) (Input 7 ) 5 Hz <2 % <2 % 8 Hz <3 % <2 % 16 Hz <2 % <2 % Omni 25 2 Dir 32 29 Battery life, artificial measurement, hours 3 11 15 Expected battery life, hours (battery size 312 - IEC PR41) 4 55-65 IRIL (IEC 6118-13:211) 8/14/2 MHz: 31/<15/<15 OSPL9 Peak 127 116 16 Hz 12 111 HFA-OSPL9 121 112 Full-on gain 1 16 Hz 52 43 Peak 66 54 HFA-FOG 55 47 Reference test gain 45 34 Frequency range 12-75 Hz 1-75 Hz Telecoil output (16 Hz) (Input 7 ) 5 Hz <2 % <2 % 8 Hz <3 % <2 % 16 Hz <2 % <2 % Omni 26 21 Dir 33 3 Battery life, artificial measurement, hours 3 11 15 Expected battery life, hours (battery size 312 - IEC PR41) 4 55-65 IRIL (IEC 6118-13:211) 8/14/2 MHz: 31/<15/<15 1) Measured with the gain control of the hearing aid set to its full-on position minus 2 and with an input SPL of 7. This is to obtain a gain response equal to the full-on gain response from e.g. IEC 6118-+A1:1994 but without influence of feedback. 2) Battery current is measured according to IEC 6118-:1983/AMD1:1994 7.11, IEC 6118-:215 7.7 and ANSI S3.22:214 6.13 after a settling time of minimum 3 minutes. 3) Based on the standardized battery consumption measurement (IEC 6118-:1983/AMD1:1994). The actual battery life depends on battery quality, use pattern, active feature set, hearing loss 1) Measured with the gain control of the hearing aid set to its full-on position minus 2 and with an input SPL of 7. This is to obtain a gain response equal to the full-on gain response from e.g. IEC 6118-+A1:1994 but without influence of feedback. 2) Battery current is measured according to IEC 6118-:1983/AMD1:1994 7.11, IEC 6118-:215 7.7 and ANSI S3.22:214 6.13 after a settling time of minimum 3 minutes. 3) Based on the standardized battery consumption measurement (IEC 6118-:1983/AMD1:1994). The actual battery life depends on battery quality, use pattern, active feature set, hearing loss
Oticon Opn S 1 minirite 1 Oticon Opn S 2 & 3 minirite 1 1 2 3 4 5 6 7 8 9 1 11 12 125 25 5 1k 2k 4k 8k Hz 13 12 11 1 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE1_OSPL9_711 26 9 216 taje 11:15:55 13 12 11 1 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE1_OSPL9_2cc 26 9 216 taje 11:15:36 1 2 3 4 5 6 7 8 9 1 11 12 125 25 5 1k 2k 4k 8k Hz 13 12 11 1 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE1_OSPL9_711 27 9 216 taje 13:38:24 13 12 11 1 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE1_OSPL9_2cc 27 9 216 taje 13:38:46 Power flex mould, Bass & Power dome 6 5 4 3 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE1_FOG_711 26 9 216 taje 11:16:37 6 5 4 3 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE1_FOG_2cc 26 9 216 taje 11:16:19 Power flex mould, Bass & Power dome 6 5 4 3 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE1_FOG_711 27 9 216 taje 13:39:17 6 5 4 3 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE1_FOG_2cc 27 9 216 taje 13:39:37 may exceed 132 (IEC 711). Special care should be 11 1 9 8 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE1_freqResp_711 26 9 216 taje 11:17:17 11 1 9 8 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE1_freqResp_2cc 26 9 216 taje 11:17: may exceed 132 (IEC 711). Special care should be 11 1 9 8 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE1_freqResp_711 27 9 216 taje 13:4:24 11 1 9 8 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE1_freqResp_2cc 27 9 216 taje 13:4:41 OSPL9 Peak 132 122 16 Hz 13 121 HFA-OSPL9 127 118 Full-on gain 1 16 Hz 56 48 Peak 66 57 HFA-FOG 59 51 Reference test gain 49 42 Frequency range 1-85 Hz 1-8 Hz Telecoil output (16 Hz) (Input 7 ) 5 Hz <7 % <2 % 8 Hz <4 % <2 % 16 Hz <2 % <2 % Omni 23 19 Dir 32 3 Battery consumption 2 Typical 1.5 ma 1.7 ma Battery life, artificial measurement, hours 3 115 15 Expected battery life, hours (battery size 312 - IEC PR41) 4 5-65 IRIL (IEC 6118-13:211) 8/14/2 MHz: 25/<2/<2 OSPL9 Peak 132 122 16 Hz 13 121 HFA-OSPL9 127 118 Full-on gain 1 16 Hz 56 48 Peak 66 57 HFA-FOG 59 51 Reference test gain 49 42 Frequency range 1-75 Hz 1-75 Hz Telecoil output (16 Hz) (Input 7 ) 5 Hz <7 % <2 % 8 Hz <4 % <2 % 16 Hz <2 % <2 % Omni 23 19 Dir 32 3 Battery consumption 2 Typical 1.5 ma 1.7 ma Battery life, artificial measurement, hours 3 115 15 Expected battery life, hours (battery size 312 - IEC PR41) 4 5-65 IRIL (IEC 6118-13:211) 8/14/2 MHz: 25/<2/<2 1) Measured with the gain control of the hearing aid set to its full-on position minus 2 and with an input SPL of 7. This is to obtain a gain response equal to the full-on gain response from e.g. IEC 6118-+A1:1994 but without influence of feedback. 2) Battery current is measured according to IEC 6118-:1983/AMD1:1994 7.11, IEC 6118-:215 7.7 and ANSI S3.22:214 6.13 after a settling time of minimum 3 minutes. 3) Based on the standardized battery consumption measurement (IEC 6118-:1983/AMD1:1994). The actual battery life depends on battery quality, use pattern, active feature set, hearing loss 1) Measured with the gain control of the hearing aid set to its full-on position minus 2 and with an input SPL of 7. This is to obtain a gain response equal to the full-on gain response from e.g. IEC 6118-+A1:1994 but without influence of feedback. 2) Battery current is measured according to IEC 6118-:1983/AMD1:1994 7.11, IEC 6118-:215 7.7 and ANSI S3.22:214 6.13 after a settling time of minimum 3 minutes. 3) Based on the standardized battery consumption measurement (IEC 6118-:1983/AMD1:1994). The actual battery life depends on battery quality, use pattern, active feature set, hearing loss
Oticon Opn S 1 minirite 15 Oticon Opn S 2 & 3 minirite 15 1 2 3 4 5 6 7 8 9 1 11 12 125 25 5 1k 2k 4k 8k Hz 13 12 11 1 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE15_OSPL9_711 26 9 216 taje 11:19:31 13 12 11 1 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE15_OSPL9_2cc 26 9 216 taje 11:19:52 1 2 3 4 5 6 7 8 9 1 11 12 125 25 5 1k 2k 4k 8k Hz 13 12 11 1 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE15_OSPL9_711 27 9 216 taje 13:44:5 13 12 11 1 OSPL9 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE15_OSPL9_2cc 27 9 216 taje 13:45:6 Power flex mould 7 6 5 4 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE15_FOG_711 26 9 216 taje 11:2:33 7 6 5 4 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE15_FOG_2cc 26 9 216 taje 11:2:5 Power flex mould 7 6 5 4 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE15_FOG_711 27 9 216 taje 13:45:33 7 6 5 4 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE15_FOG_2cc 27 9 216 taje 13:46:29 may exceed 132 (IEC 711). Special care should be 12 11 1 9 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE15_freqResp_711 26 9 216 taje 11:21:17 12 11 1 9 1 2 Hz 5 1 2 Hz 5 1 Opn1mRITE15_freqResp_2cc 26 9 216 taje 11:21:34 may exceed 132 (IEC 711). Special care should be 12 11 1 9 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE15_freqResp_711 27 9 216 taje 13:46:59 12 11 1 9 1 2 Hz 5 1 2 Hz 5 1 Opn2+3mRITE15_freqResp_2cc 27 9 216 taje 13:47:19 OSPL9 Peak 135 127 16 Hz 132 125 HFA-OSPL9 13 122 Full-on gain 1 16 Hz 65 57 Peak 72 64 HFA-FOG 65 57 Reference test gain 58 46 Frequency range 1-82 Hz 1-78 Hz Telecoil output (16 Hz) (Input 7 ) 5 Hz <2 % <2 % 8 Hz <2 % <2 % 16 Hz <3 % <2 % Omni 18 18 Dir 28 29 Battery life, artificial measurement, hours 3 11 15 Expected battery life, hours (battery size 312 - IEC PR41) 4 45-65 IRIL (IEC 6118-13:211) 8/14/2 MHz: 31/<16/<16 OSPL9 Peak 135 127 16 Hz 132 125 HFA-OSPL9 13 122 Full-on gain 1 16 Hz 65 57 Peak 72 64 HFA-FOG 65 57 Reference test gain 58 46 Frequency range 1-75 Hz 1-65 Hz Telecoil output (16 Hz) (Input 7 ) 5 Hz <2 % <2 % 8 Hz <2 % <2 % 16 Hz <3 % <2 % Omni 18 18 Dir 28 29 Battery life, artificial measurement, hours 3 11 15 Expected battery life, hours (battery size 312 - IEC PR41) 4 45-65 IRIL (IEC 6118-13:211) 8/14/2 MHz: 31/<16/<16 1) Measured with the gain control of the hearing aid set to its full-on position minus 2 and with an input SPL of 7. This is to obtain a gain response equal to the full-on gain response from e.g. IEC 6118-+A1:1994 but without influence of feedback. 2) Battery current is measured according to IEC 6118-:1983/AMD1:1994 7.11, IEC 6118-:215 7.7 and ANSI S3.22:214 6.13 after a settling time of minimum 3 minutes. 3) Based on the standardized battery consumption measurement (IEC 6118-:1983/AMD1:1994). The actual battery life depends on battery quality, use pattern, active feature set, hearing loss 1) Measured with the gain control of the hearing aid set to its full-on position minus 2 and with an input SPL of 7. This is to obtain a gain response equal to the full-on gain response from e.g. IEC 6118-+A1:1994 but without influence of feedback. 2) Battery current is measured according to IEC 6118-:1983/AMD1:1994 7.11, IEC 6118-:215 7.7 and ANSI S3.22:214 6.13 after a settling time of minimum 3 minutes. 3) Based on the standardized battery consumption measurement (IEC 6118-:1983/AMD1:1994). The actual battery life depends on battery quality, use pattern, active feature set, hearing loss
Notes Notes
Denmark 21372CA-US / 218.11.19 / Ver 1. Manufacturer: Oticon A/S Kongebakken 9 DK-2765 Smørum Denmark www.oticon.global Imported and Distributed by: Audmet Canada Ltd 16-495 Yonge St Toronto, ON M2N 6K1 www.oticon.ca www.oticon.ca