FAQ# 940-1F091 AMCI Frequently Asked Question

Similar documents
Series 1500 Resolver Interface Modules

Series Intelligent Resolver Interface Modules. User Manual. Allen-Bradley 1771 I/O Module. Manual:

SYSTEMS ELECTRONICS GROUP

1141, 1142, 1141A & 1142A Manual One and Two Channel 1762 I/O Resolver Interface Modules Revision 1.0

DC425 NEMA 4X Analog Output Transducers

ADVANCED MICRO CONTROLS INC. Manual #: 940-0D141

NX2A4X Manual Rev 2.0 Networked Four Channel Resolver Interface Module

Recommended Practices for Installation For EC Directive 2004/108/EC Relating to EMC Supplement to Installation and Operating Manual

1241 Resolver Interface Module

NX3A1X Manual Rev 3.0 Networked Resolver PLS Module

Microsystems. SCI-6 Sound Card Interface Kit Version 1.09 January 2015

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

1242 Resolver Interface Module

EMC Installation Guide

ADVANCED MICRO CONTROLS INC. Manual #: 940-0E012

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

ETC Installation Guide

Appendix D. EMC Installation Guidelines. Safety Considerations. Ferrite Absorbers and P-Clips. General Product Philosophy

Navigator II INstallatIoN MaNUal For static and PaN/tIlt configurations

Remote I/O Scanner. Catalog Number 1747-SN. Installation Instructions. Publication

HB5M. Hollow Bore Optical Encoder Page 1 of 6. Description. Related Products & Accessories. Features

AMCI NX3A1E Specifications Rev 0.0 Resolver PLS Ethernet Module

MLA-1 / MLA-10 Installation/Operations Manual

A2K. Absolute Optical Encoder: Kit Version Page 1 of 7. Description. Features

ME15 Magnetic Encoder Manual Revision 1.1

Position Transducers MICRON/ EUCRON/BAUMER/GE REPLACEMENTS

RE 2 52 ROTARY ENCODER

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE

Operating Instructions

MLC 420. MAGNETIC Press Brake ENCODERS OPERATION MANUAL

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

Frequently Asked Questions

RE 2 37 ROTARY ENCODER

Autotech Controls M7350 Programmable Resolver Decoder Function Modules. Instruction & Operation Manual

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Optical Kit Encoder Page 1 of 14. Description. Features

This Datasheet is for the IC693CBL300. I/O Bus Expansion Cables.

VibraLINK switchable junction boxes Installation and operating guide VLL series

DC25 Incremental DuraCoder

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

*740130* 2800, 9500 Series. Cable Companion Motor Power. Cable AC Power. Cable Retrofit Acessories

GEMCO. Installation & Programming Manual. Series 1746R. PLC Resolver Interface Module. For Allen-Bradley SLC 500 I/O Chassis

ISSPRO 3 3/8" DIAMETER PROGRAMMABLE SPEEDOMETER Air Core Version

MODELS PD230 AND PD1230 Installation Instructions

Installation & Operation Guide

The M1750 PLS. The Modular Electronic Cam Switch. UL Listed. Introduction

ADVANCED MICRO CONTROLS INC. Manual #: 940-0D101

EASTERN LABS. Instructions Model RM /25/2007. Operation. Junction Box Assembly. Different Types of Switch Installations

8213 Quick Start Guide ControlLogix Resolver PLS

DirectCommand Installation Case/Flexi-Coil/New Holland Air Cart Kit (Variable Rate Electro Hydraulic Systems) Ag Leader Technology

Optical Kit Encoder Page 1 of 17. Description. Features

PL-1746-C02. PL-1746 Series Features

bidirectionally as well as the rotation sense of shafts. With absolute encoders instead, each incremental

Hardware Manual 1240i

INTERCOM SYSTEM Model ICA900

Installing a Power over Ethernet injector

Optical Encoders. Sold & Serviced By: Toll Free Phone: Toll Free Fax:

INSTALLATION INSTRUCTIONS:

GM-K PRG. Dual Camera interface for 15 Chevy Sonic/Spark/Trax NTV-KIT626 BHM 10/15/15 NTV-DOC235

C-Series C142 Machine Controller Eurocard DIN Packaged Systems

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

SCXI-1345 Shielded Cable

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

Adapter Kit - QSI Electronics to G-Series Meter Installation Instructions

ADVANCED MICRO CONTROLS INC. Manual #: 940-0D092

CONNECTING SENSORS TO DATA ACQUISITION SYSTEM ANALOG INPUTS

HS-27-Mini. Headstage preamplifier providing 27 channels of unity gain amplification.

Screw. Nut Guide. Features

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

DEFLECTION AND TWIST MEASUREMENT SYSTEM (DTMS) Model 47

ANC Series RS-422 Serial Communications Adapter

EMC 10T "CE" Mechanical Upgrade Procedure

Installation Instructions Model ZAM-180

Technical Practice BP-2 POWER FAILURE TRANSFER UNIT. Issue 8, April 1988

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

Product Information ROC 425 ROQ 437. Absolute Rotary Encoders with Solid Shaft for Safety-Related Applications

Vorne Industries. 87/001 RS-485 Communications Board User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

TNC SERIES Miniature Coaxial Connectors

Building the Communication Cable

How-To #7: Assemble an H-bridge Circuit Board

HS-27 Manual 5/2/2013. Neuralynx, Inc. 105 Commercial Drive, Bozeman, MT Phone Fax

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

MOUNTING STYLE. A - Axial (end) R - Radial (side) See Chart Below CONNECTOR CHANNEL A, B, C, D, R, T, U, 2, 3, 7, W E, F, G, H, J, K, M, N B, E 5 E

Optical Kit Encoder Page 1 of 14. Description. Features

Insert the male, 90 angled, 2x10 connectors into the corresponding 2x10 sockets and put them in place, flat under the PCB. Solder.

Product Manual MNX10043 REV A MODEL DSB. Dual Sensor Modular Switch box

Standard Strip Series

Twisted Nitro Stunt Racing New Cabinet Design with Sintra Marquee Supplement to Operation & Service Manual

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

CCN-to-Ethernet Converter Installation Instructions

Servo Auto Collet Spindle SP00AC-SR12000

Product Data Sheet. BMS/Graphics Interface. Features

PLC Racks IC697CHS782/783

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

Heathkit HR-1680 PC Card Extender. Heathkit HR-1680 PC Assembly Extender Assembly

Pi PoE Switch HAT Quick Start And FAQ. Getting started. Kit contents

7011-C, 7012-C, 7013-C, 7015-C, 7018-C, 7021, MTC-2 Mass Terminated Assembly Twisted pair (45) 96-pin female 96-pin female 2 6.

MAXIMA + Series ROTARY LEVEL CONTROL

Sense it! Connect it! Bus it! Solve it! ENCODERS

Sirius 24 and 48 DMX Output Kit Installation and Operation Instructions

Transcription:

FAQ# 940-F09 Frequently Asked Question Can I Use Transducers From Other Manufacturers With Controllers? When receives an inquiry about using foreign products, it is generally about transducers from one of four companies, Autotech, Namco/C&A,, or Gemco. Some of the transducers made by these companies can be used with controllers and some cannot. It depends on the type of transducer and how the resolver itself is wired in the transducer. Even though it is possible to use transducers from other manufacturers, we strongly suggest using transducers whenever possible. is the only company in the marketplace that designs and manufactures the resolvers used in its products. Our transducers and modules are designed to work together, and will work for years to come when specified and installed properly. Because you can use some transducer from other manufacturers with controllers, the reverse of the question is also true. You can use transducers with controllers from other manufacturers. The last section of this FAQ covers how to accomplish this. Types of Transducers, and the three of the four companies listed above, make two types of resolver based transducers, single-resolver transducers, and dual-resolver transducers. Single-resolver transducers come in two forms. The first is the single-turn transducer. The resolver is directly coupled to the transducer s input shaft and one turn of the input shaft yields one turn of the resolver. The second form of the single-resolver transducer is the geared multi-turn. In this package, the resolver is attached to the input shaft through a gear reduction so that multiple turns of the input shaft yield one turn of the resolver. To the controller, single-resolver transducer appear to make only one rotation per cycle. The controller is unaware of any gear ratio between the transducer s input shaft and the resolver. It is usually possible to make single-resolver transducers for other manufacturers compatible with controllers. In most cases, you will need to purchase a Reference Module from in order to make the transducer work with products. As the name implies, dual-resolver transducers contain two resolvers and are designed for high resolution, multi-turn applications. The first resolver is directly coupled to the input shaft while the second resolver is attached to the first through a gear ratio. This ratio defines the number of turns the transducer can encode. Due to differences in gearing, it is usually not possible to make dual-resolver transducers for other manufacturers compatible with controllers. If you want to use a dual-resolver, multi-turn transducer, or your transducer is not from Autotech, Namco/ C&A,, or Gemco, you must contact for assistance. Reference Modules Resolvers are similar to rotary transformers, and one of a resolver s characteristics is the ratio of output voltage to input voltage, which is called the Transformation Ratio (TR). All of the resolvers designed to work with our products have a TR of 0.95. Autotech and Gemco use resolvers whose TR is.40, while Namco/C&A and use resolvers whose TR is 0.45. A Reference Module, shown below, is a single-ended transformer that is used to adjust the Reference Voltage going out, so that the return signals appear to be coming from a resolver with a 0.95 TR..5" Max. 6- x.0." Long.0" Dia. or Sq. RM-X Reference Module Pin : Output Pin : Input Pin : Common Schematic In/Out Out/In Common Manufacturer Namco/C&A Autotech Gemco Reference Module RM- RM- RM-5 Call

Reference Modules (continued) The 6- mounting stud makes it easy to install the Reference Module on an enclosure wall or mounting panel. Note that the Reference Module must be mounted as close to the controller as possible. You should also mount a seven point terminal block next to the RM to simplify your wiring. If you use a terminal block, you can use s standard cable to wire from the controller to the Reference Module. As shown in the diagram, the pairs shields should be kept separate when splicing the cable. This practice limits the amount of noise that can be coupled between the shields which helps improve the noise immunity of the system. BELDEN 987 or 970 Cable To Controller WHT GRN RED WHT GRN RM-X Reference Module RED BELDEN 987 or 970 Cable To Transducer The next sections of this FAQ give specific instructions on using the transducers from other manufacturers. Autotech Transducers Some of s plug-in modules, and our NEXUS resolver interface units, directly support Autotech transducers. These units do not require a Reference Module to convert the reference voltage and may support Autotech s dual-resolver, absolute multi-turn transducers, the RL0 s. Refer to the product s user manual to determine if a Reference Module is required. If your controller does not directly support Autotech transducers, you can use a RM- Reference Module. The table below lists Autotech transducers that can be made compatible with controllers through the RM- and also lists replacement transducers. All connectors on transducers are s style and will not plug into Autotech cable connectors. Autotech Transducers Transducers Comments SAC-RL0-00 RX-J0/7 E6R-RL0-000EF E7R-RL0-000EF E6R-RL0-000ES E7R-RL0-000ES E6R-RL0-000SF E7R-RL0-000SF E6R-RL0-000SS E7R-RL0-000SS H5-FE H5-SE H5-FS H5-SS Mechanically identical except that wires come out the back instead of the side. Bolt-in replacement. Shorter body length. Bolt-in replacement when servo mounting. Different bolt pattern on front, shorter body. Bolt-in replacement. Shorter body length, side connector in different location. Bolt-in replacement when servo mounting. Different bolt pattern on front, shorter body length, side connector in different location. SAC-RL00-00 HT-400 Direct replacement. SAC-RL00-M HT-400-E Bolt-in replacement, connector. SAC-RL0-G00C, SAC-RL0-G00M HTT-400- Bolt-in replacement, dual connectors with similar configuration to -G0M 0 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786 Tel: (860) 585-54 Fax: (860) 584-97 http:\\www.amci.com

Autotech Cabling Due to differences in construction, Autotech cable is not supported by. Any existing cables must be replaced with Belden 987, 970, or an exact equivalent. The following is a wiring table for all Autotech transducers that can be used with an RM-. The table cross references wire color, resolver designations, and Autotech connector pin-out. The RM- is wired into the cables as shown on the preceding page. Resolver Designations SAC-RL0-00 SAC-RL00-00 Terminals SAC-RL00-Gxxx Terminals Autotech MS Connector /RED R RED/WHT R(RL) F RED R YEL/WHT R(RH) E WHT S RED S D /WHT S S 4 C /GRN S YEL S 5 B GRN S4 BLU S4 6 A : Denotes black wire of black and colored wire pair : Denotes colored wire with white strip Do not, under any circumstances, connect the shields of the transducer cable to the earth ground connection of the transducer. This connection may form a ground loop that could damage the controller or transducer. The earth ground connection on the MS style connectors is pin G. The earth ground connection on the screw terminal transducers is a green screw. Namco/C&A Transducers One of the major driving forces behind the creation of this FAQ was Namco s decision to obsolete the entire C&A product line. This decision has left their former customers looking for system replacement parts. While some customers have decided to replace their entire system with products, others have replaced only the parts that have failed. If you find yourself in need of replacement parts, contact for assistance. We have developed extensive cross-reference table between product lines so we can help you to specify the proper components quickly. Fortunately, Namco/C&A transducers are the easiest to get working with controllers. All that Namco/C&A transducers require to operate with products is a RM- Reference Module and minor changes in cabling. Namco/C&A Cabling Namco/C&A transducer cable specifications were almost identical to s. They specified the same Belden cable, the same transducer connectors and the same wiring pattern for those connectors with one exception. If you followed Namco/C&A guidelines when specifying the transducer cable, you should be able to use it with only one change. Some Namco/C&A cabling prints show the shields of the transducer cable connected to pin D of the transducer connector. This connection must be removed before connecting the Namco/C&A transducer to controllers. grounds the shields at the controller end of the cable and if this connection is not removed, the shields will be grounded at both ends, potentially forming a ground loop that could damage the transducer or controller. To remove this connection, carefully disassemble the transducer connector and check to see if the shields are attached to the connector s pin D. If they are, cut the shields at the pin and cut them back to the cable s outer insulation. Carefully re-assemble the connector. You may also need to purchase the proper Transducer Input Connector for the controller. Refer to the product s user manual for the appropriate connector part number. 0 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786 Tel: (860) 585-54 Fax: (860) 584-97 http:\\www.amci.com

Transducers uses the same resolver used in Namco/C&A transducers. Therefore, all transducers require a RM-5 Reference Module to operate with controllers. Cabling does not have the full technical specifications on the transducer cable used by but it is individually shielded, twisted pair. Even if the capacitance specifications are significantly different from s, the cable should be acceptable for lengths of up to 50 feet. Longer lengths should be replaced or extensively tested before used in a production setting. cabling prints show a shield lug at the transducer end of the cable that is usually attached to the connector strain relief screw or the body of the transducer. This connection must be removed before connecting the transducer to an controller. grounds the shields at the controller end of the cable and if this connection is not removed, the shields will be grounded at both ends, potentially forming a ground loop that could damage the transducer or controller. To remove this connection, remove the lug connection from the connector or transducer body and cut the shields off inside the cable s outer insulation. You will also need to purchase the proper Transducer Input Connector for the controller. Refer to the product s user manual for the appropriate connector part number. The following cross reference table shows how to cross resolver signals between and. Connector Pin Resolver Designations Transducer Connector Pin F WHT R /RED A E /WHT R RED B D /GRN S WHT F C GRN S /WHT G B RED S /GRN E A /RED S4 GRN C : Denotes black wire of black and colored wire pair When wiring an cable to an Transducer Input Connector, use the table to cross the to the and then refer to published cable wiring diagrams to determine the correct pin on the input connector. Exact pin numbers on the Transducer Input Connector cannot be shown because the pin numbers are based on the style of connector and the input channel you are connecting the transducer to. Using a terminal block next to the RM-5 when converting the installation will greatly simplify the process by allowing you to switch between color codes at the terminal block. Gemco Transducers Gemco usually installs the same resolver used by Autotech, but is aware that Gemco has used resolvers from different manufacturers in their transducer products in the past and has installed resistors across the stator windings to increase the load on these windings. This has the effect of lowering the voltage from these windings, which makes the TR of the resolvers all look the same, but it also has the added effect of introducing a large amount of phase shift and signal distortion which makes these transducer impossible to use with our products. Consequently, has handled Gemco requests on a case by case basis through technical support and will continue to do so in the future. If you want to use a Gemco transducer with product, contact for assistance. 0 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786 Tel: (860) 585-54 Fax: (860) 584-97 http:\\www.amci.com

Gemco Transducers (continued) is also aware that Gemco has introduced a new line of transducers that are advertised as drop in replacements for transducers. You must be aware of two points before you decide to use these transducers. ) The resolvers used in the transducers are not manufactured by. is the only company in the marketplace that designs and manufactures the resolvers used in its products. The resolvers used by Gemco are probably manufactured by Harowe or Singer/Kearfoot and consequently will have different electrical characteristics than resolvers. These differences could affect accuracy and reliable operation, especially in applications with long cable runs. ) The mounting blocks, bearing blocks and internal mounting plates for all of our geared singleresolver and dual-resolver transducers are manufactured by at our facility to exacting standards. The assembly, alignment, and testing of these transducers also follow exacting standards. obviously has no control over how Gemco manufactures and tests their transducers. Therefore, we cannot guarantee their accuracy or reliable operation. Gemco Cables Like their transducers, handles Gemco cabling questions on a case by case basis. Contact if you have any questions about using Gemco cabling in your application. Using Transducers With Controllers From Other Manufacturers If you can get a transducer from another manufacturer working with an controller, then it is also possible to get an transducer to work with the controllers from that manufacturer that interface with its transducer. This is accomplished by installing the RM module as shown on page of this FAQ but reverse its Input and Output connections. The Output connection (Pin of the RM) goes to the controller and the Input connection (Pin ) goes to the transducer. Remember that dual-resolver transducers from will generally not work with competitors controllers because of a difference in gearing styles. Using and a Competitors Transducer Together If your controller has multiple transducer inputs, you bring transducers and transducers from other manufacturers into the controller by wiring the transducer directly into the controllers Transducer Input Connector and attaching the other transducers through a Reference Module. The following figure is an example of doing this with Autotech transducers. Module Connector Mates with Transducer Input Connector MS-8 shown. 8 7 6 5 4 To MS-6 Connector Pin A To MS-6 Connector Pin B To Autotech R To Autotech R RM- Reference Module If your are using an product that directly supports Autotech transducers and you wish to attach both and Autotech transducers, set the Resolver Type parameter on the unit to and follow the above paragraph. 0 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786 Tel: (860) 585-54 Fax: (860) 584-97 http:\\www.amci.com