R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

Similar documents
R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

MODEL: R2K-1 SEN TRONIC AG. R2K Series

R1M-J3 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL RTD & POTENTIOMETER INPUT MODULE MODEL. (8 points)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

NPN / PNP DISCRETE INPUT & NPN TRANSISTOR OUTPUT MODULE, 16 points each

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

R7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)

DLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)

BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

NPN/PNP DISCRETE HIGH SPEED INPUT & NPN TRANSISTOR OUTPUT MODULE

R3-NL1 LONWORKS INTERFACE MODULE BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL. R3-nL1 MODEL

R3-NL2 INSTALLATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL LONWORKS INTERFACE MODULE MODEL. (I/O 56 points)

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

MODEL: GR8-EM. Communication Adaptor GR8 Series

INSTRUCTION MANUAL 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

PWR. Power Module Slots

DISCONTINUED MODEL Replaced with Model MSRPAC-2006

DISCONTINUED MODEL Replaced with Model MSRPAC-2005

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)

RZMS-U9 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (universal input, 12 points; isolated)

MODEL: MSRPAC PC Recorder Series

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

TM3TI8T module TM3-8 inputs temperature

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

TM3DI16 module TM3-16 inputs

TM3TI4 module TM3-4 inputs temperature

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

TM3AI4 module TM3-4 analog inputs

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM241C40R controller M IO relay

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

After unpacking, confirm that there are no problems (scratches and dirt) on the exterior before use.

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

TM3TI4 module TM3-4 inputs temperature

Voltage Current Front-mounting bracket

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

AO561 Analog Output Module

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

TM241C40U controller M IO transistor NPN

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

RZUS-U9 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (universal input, 12 points; isolated; bus-powered USB)

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

TM241C24T controller M IO transistor PNP

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

INTELLIGENT SERVER. Model: BMS-LSV6E

MODEL: 40DN. Digital Panel Meters 40 Series

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

FX-485PC-IF RS485 Interface Unit Hardware Manual

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

TCNM-ACBB1 Installation Manual

General Specifications

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

TM3DI16G module TM3-16 inputs spring

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE

48NDVD BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL BARGRAPH INDICATING ALARM MODEL

TU531, TU532 Terminal Unit

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

TM241CE40R controller M IO relay Ethernet

Moxa TCC-100 Series Hardware Installation Guide

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Series Watt DC Power Supplies

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

1. Safety Precautions (Read these precautions before use.)

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Expansion Module HZS 541-1S

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

FX2NC-ENET-ADP Ethernet adapter USER'S MANUAL

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

Operating Manual. Dynisco /8 DIN Indicator Concise Product Manual

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

HygroClip DI Digital Interface for HygroClip Probes v 1.0 Instruction Manual

KCH-B KCH-B. Merits. Application examples. Counters for Display of High-speed Addition and Subtraction. Counters. switches to write settings

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

Solid-state Timer H3YN

About the Manual. ST-3400 Series Installation Guide. Package Contents

AI561 Analog Input Module

TM241CE24T controller M IO transistor PNP Ethernet

Package Contents. GP Options (Made by Digital)

HMISCU6A5 3 5 color touch controller panel - Dig 16 inputs/10 outputs

TM241CE40R controller M IO relay Ethernet

Transcription:

INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System s Sales Office or representatives. This product is for use in general industrial environments, therefore may not be suitable for applications which require higher level of safety (e.g. safety or accident prevention systems) or of reliability (e.g. vehicle control or combustion control systems). For safety, installation and maintenance of this product must be conducted by qualified personnel. PACKAGE INCLUDES: PC Recorder (body CJC sensor)...() Cable (9-pin D-sub cable, straight type)...() CD (software and users manual)...() MODEL NO. Confirm Model No. marking on the product to be exactly what you ordered. INSTRUCTION MANUAL This manual describes necessary points of caution when you use this product, including installation, connection and basic maintenance procedures. Read also the Users Manual for the software included in the CD for maximum use of the PC Recorder. POINTS OF CAUTION CONFORMITY WITH EU DIRECTIVES This equipment is suitable for Pollution Degree and Installation Category II (transient voltage 00V). Reinforced insulation (input or RS--C/RS- to power: 00V) and basic insulation (input to RS--C/RS-: 00V) are maintained. Prior to installation, check that the insulation class of this unit satisfies the system requirements. Altitude up to 000 meters. The equipment must be mounted inside a panel. Insert noise filters. Okaya Electric Industries Model SUP-EH or equivalent for the power source connected to the unit, and TDK Model ZCAT 0-0 or equivalent for the RS--C cable are recommended. The equipment must be installed such that appropriate clearance and creepage distances are maintained to conform to CE requirements. Failure to observe these requirements may invalidate the CE conformance. The actual installation environments such as panel configurations, connected devices, connected wires, may affect the protection level of this unit when it is integrated in a panel system. The user may have to review the CE requirements in regard to the whole system and employ additional protective measures to ensure the CE conformity. Install lightning surge protectors for those wires connected to remote locations. POWER INPUT RATING & OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below: 00 0V AC rating: V, Hz, approx. 0VA V DC rating: V ±0%, approx. W GENERAL PRECAUTIONS Before you remove the module, turn off the power supply and input signal for safety. PC RECORDER SOFTWARE Use the latest version of PC Recorder Software included in the product package. ENVIRONMENT Indoor use. When heavy dust or metal particles are present in the air, install the module inside proper housing with sufficient ventilation. Do not install the module where it is subjected to continuous vibration. Do not subject the unit to physical impact. Environmental temperature must be within - to 0 C ( to 0 F) with relative humidity within 0 to 90% RH in order to ensure adequate life span and operation. Be sure that the ventilation slits are not covered with cables, etc. WIRING Wrong connection may damage the module. Do not connect cables to moving parts or pull them tightly. Do not install cables close to noise sources (relay drive cable, high frequency line, etc.). Do not bind these cables together with those in which noises are present. Do not install them in the same duct. AND... The module is designed to function as soon as power is supplied, however, a warm up for 0 minutes is required for satisfying complete performance described in the data sheet. EM- Rev. P. /

PC REQUIREMENTS (provided by the user) MSR-V NORMAL MODE (storing rates 00 ms) HIGH SPEED MODE (storing rates 00 / 00 ms) PC IBM PC/AT or compatible Operating system Windows XP SP, SP, Windows Vista Business -bit, Windows Professional -bit or Windows 0 -bit, -bit Note: Proper software functions may not be ensured under certain conditions. CPU Pentium III 00 MHz or higher Pentium IV.0 GHz or higher Screen area 0 by pixels or better resolution Display color 000 colors ( bits) Video memory MB minimum; MB recommended MB minimum Main memory MB recommended for Windows XP GB recommended for Windows Vista, Windows, Windows 0 MB recommended for Windows XP GB recommended for Windows Vista, Windows, Windows 0 Hard disk area Use an internal hard disk. * Max. approx. 00 MB required per day. Printer CD drive Card reader drive Communication port Use an internal hard disk. * Max. approx. 00 MB required per day. Use a printer for Windows. The programs use Standard System Fonts used in Windows. Use a printer driver for Standard System Fonts. Windows supported CD drive is used to install the software program. Used with devices which save data in a CF Card RS--C port (COM through COM) supported LAN card by Windows LAN card *. External (e.g. SCSI) devices may impair appropriate performance. MSRLS, MSRLV PC Operating system MSRLS MSRLV IBM PC/AT or compatible Windows XP SP or SP. For High Speed Mode (Group 0, 0 msec. storing cycle), use Windows XP SP, SP. Note: Proper software functions may not be ensured under certain conditions. CPU Pentium II MHz or higher * Screen area 00 by 00 pixels or better resolution 0 by 0 pixels or better resolution Display color 000 colors ( bits) Main memory MB for Windows XP Hard disk area 00 MB minimum * Follow the respective OS s standard for Windows XP. CD drive Windows supported CD drive is used to install the software program. Communication port RS--C port (COM through COM) supported by Windows * or LAN communication card *. Alternately, Celeron 00 MHz or higher with the secondary cache. For High Speed Mode (Group 0, 0 msec. storing cycle), Pentium III 00 MHz or higher. *. External (e.g. SCSI) devices may impair appropriate performance. *. The RS--C port may be predefined for other purposes than for COM port. Driver software change or system configuration may be required before using such a port. Note : At 0 msec. storing cycle (Group 0), the MSRLS/LV may not be able to store every bit of data depending upon the PC s performance levels. These missing data will be substituted by the last stored data. Only one () node is connectable in the high speed mode. Note : Please refer to the hardware data sheet for response time of the module. EM- Rev. P. /

COMPONENT IDENTIFICATION TOP VIEW T T T T T T T INSTALLATION DIN RAIL MOUNTING Set the body so that its DIN rail adaptor is at the bottom. Pull down the DIN rail adaptor. Position the upper hook at the rear side on the DIN rail and push in the lower. Push back the DIN rail adaptor. DIN Rail mm wide 9 0 9 0 9 0 WALL MOUNTING Set the body so that its DIN rail DIN Rail Adaptor adaptor is at the bottom. Pull down the DIN rail adaptor. Refer to EXTERNAL DIMENSIONS. CJC Sensor (model: CJM) REAR VIEW Power Terminals RS--C 9-pin Connector RUN Indicator LED RS- Connector Node Address Setting Rotary SW Configurator Jack Specifications TERMINAL CONNECTIONS Connect the unit as in the diagram below. Attach the CJC sensor together with input wiring to the input screw terminals. The sensor is calibrated for each particular module and not interchangeable with another. Check the serial numbers of the module and sensor. EXTERNAL DIMENSIONS unit: mm (inch) 0 (.9) (.9) (.0). (.) (.0) dia. MTG HOLES T T T T T T T 0 (.) 0 (.09) (.) DIN RAIL mm wide 9 0 9 0 9 0 (.) (.) FOR WALL MOUNT. (.) CJC SENSOR (model: CJM) (.) 0 (.) [ (.)]. (.) M INPUT TERMINALS EM- Rev. P. /

CONNECTION DIAGRAM Note: In order to improve EMC performance, bond the FG terminal to ground. Caution: FG terminal is NOT a protective conductor terminal. INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT INPUT 9 INPUT 0 INPUT INPUT INPUT INPUT INPUT INPUT DC INPUT T/C INPUT ext. wire CJC Sensor TRIGGER INPUT 9 0 9 0 9 0 Output Circuit Term. Resist. Power Circuit Input Circuit D-SUB CONNECTOR T T T T T T T RS--C U () V () FG Shielded Twisted-pair Cable To Other PC Recorders Jumper* POWER * When the device is located at the end of a transmission line via twisted-pair cable, (when there is no cross-wiring), close across the terminal T T with the attached jumper pin (or with a leadwire). When the device is not at the end, remove the jumper pin. Note : This device is not designed to cancel noise included in the input signals. Be careful to eliminate such noise by using shielded cables. Note : Be sure to maintain the same potential at all the common negative terminals for DC input. RS--C INTERFACE ABBR. PIN NO. EXPLANATION OF FUNCTION BA (SD) BB (RD) AB (SG) CB (CS) CA (RS) 9 9 Transmitted Data Received Data Signal Common Clear to Send Request to Send Not Used. DO NOT connect. Connecting may cause malfunctions. EM- Rev. P. /

WIRING INSTRUCTIONS M SCREW TERMINAL (Input signal) Torque: 0. N m SOLDERLESS TERMINAL Refer to the drawing below for recommended ring tongue terminal size. Spade tongue type is also applicable. Applicable wire size: 0. to. mm (AWG9 to ) Recommended manufacturer: Japan Solderless Terminal MFG.Co.Ltd, Nichifu Co.,ltd (.) max. (.) dia. max (.) mm (inch) EURO TYPE CONNECTOR TERMINAL (Power input, Modbus) Applicable wire size: 0. to. mm (AWG to ) Stripped length: mm COMMUNICATION CABLE CONNECTIONS RS--C CONNECTOR RM T T T T RS- RM RS- RM T T T T * T T T T * FG * *. Internal terminating resistor is used when the device is at the end of a transmission line. *. Install shielded cables to all sections and ground them at single point. EM- Rev. P. /

INPUT RANGE SELECTING Select switches to match the input signal according to the table below. SW0 SW0 is fixed to the position. DO NOT CHANGE. SW SW0 SW0 SW0 SW0 O N SW0 SW0 SW0 SW SW0 SW0 SW0 SW0 O N SW0 SW0 SW0 SW0 SW0 INPUT SWITCHES SETTING NOTES Thermocouple Voltage input, 0.V or less Voltage input, above 0.V (*) (*) Factory default setting SW0 SW0 (ch ch ) SW0 SW0 (ch 9 ch ) SW (ch ch ) SW (ch 9 ch ) SW0 SW0 (ch ch ) SW0 SW0 (ch 9 ch ) SW (ch ch ) SW (ch 9 ch ) SW0 SW0 (ch ch ) SW0 SW0 (ch 9 ch ) SW (ch ch ) SW (ch 9 ch ) Set to position OFF Set to position ON Set to position ON Attenuation OFF Attenuation OFF Attenuation ON CHECKING ) Terminal wiring: Check that all cables are correctly connected according to the connection diagram. ) Power input: Check supply voltage. ) Input: Check that the input is within 0 00% of fullscale. ) DIP SW setting: Check that all switches are set correctly. ADJUSTMENT PROCEDURE This unit is calibrated at the factory to meet the ordered specifications, therefore you usually do not need any calibration. MAINTENANCE Regular calibration procedure is explained below: CALIBRATION Warm up the unit for at least 0 minutes. Apply 0%, %, 0%, % and 00% input signal. Check that the output signal for the respective input signal remains within accuracy described in the data sheet. When the output is out of tolerance, please contact M-System s Sales Office or representatives. EM- Rev. P. /