Series Pressure Sensor Instruction Sheet

Similar documents
Series Pressure Sensor Instruction Sheet

Delta Multifunction Pressure Sensor DPA Series

Automation for a Changing World. Delta Multifunction Small Pressure Sensor DPA Series.

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

Optimum sensing capability for LCD manufacturing

panasonic.net/id/pidsx/global

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

ISE5B. Series ZSE5B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

PRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I

E2Q4 Square Proximity Sensor

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

PRD/PRDW Series. Long Distance Type

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure

Suitable for detecting transparent films or transparent bottles

Operating instructions. Speed monitor D / / 2014

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

Head-separated Dual Display Digital Pressure Sensor DPC-100 SERIES DPH-100 SERIES

The dual display means that the current value and the threshold value, it makes direct setting of threshold value

-ment Ambient humidity 35 to 95%RH, Storage :35 to 95%RH

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Mini Photoelectric Sensor

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

DP2500 DP0250. Differential Pressure Transmitter. Product Bulletin

Operating instructions. Switching amplifier DN0210 DN / / 2015

Terminal block 2 A 5 X 3. Specification

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Multi Channel Pressure Sensor Controller Operation Manual PSE200 Series

DC 2-wire Cylindrical Inductive Proximity Sensor

BGS (at min. setting) BGS (at max. setting)

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Type Pressure range description Part number

Chapter. In This Chapter...

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

Making Hazardous Operations Safe and Productive

4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm

Pressure sensors SPAN

the Interactive Catalog

Head-separated Digital Pressure Sensor For Gas DP5 SERIES DPH SERIES. High speed response of 1/1,000 sec. High speed response 1 ms

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

GE Industrial Sensing. Druck DPI 104. Digital pressure indicator User manual - K394

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Compact Inductive Proximity Sensor

DP DP2500 DP0250

Technical Data. Dimensions

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Inductive Proximity Sensor

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

T2314, T2414. Instruction Manual

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Inductive Proximity Sensor

Even a specular background does not affect the sensing performance if the sensor is located 30mm away from it (when directly opposite).

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

EtherCAT Remote I/O Terminal GX series

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection. Hardly affected by background

NA1-5. Ultra-slim Body 25mm Beam Pitch Area Sensor. Even a Slim Hand Is Detected by the 25mm Pitch Beam Curtain AREA SENSORS.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Convergent Reflective Micro Photoelectric Sensor

Process displays For current and voltage

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:

M5100 Heavy Industrial Pressure Transducer

Chore-Tronics IDM Board Instruction

LCD Readout Digital Pressure Switch

SA1E: Photoelectric Switches. Polarized Retroreflective Type. Through-beam Type

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

F3S-B. Safety Design for Category 2. Suitable for Detecting Human Bodies in a Dangerous Area. Safety Light Curtain. Features

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Analog Modules AS-i, IP67, M12

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Linear Position Transducer HLT 1000-R2

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

Installation Instructions Temperature transmitter TAA /00 06/2011

E4PA. Ultrasonic Displacement Sensor. Ordering Information

One step ahead in performance and mounting ease

V E1B Snap-in I/O Module

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

E2K-X4ME1 2M E2K-X4ME2 2M

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Multi-range pressure and differential pressure transmitter

SERIES. FX-311 realizes the ultimate in ease-of-operation. Its operation enables easy and full use of latest technology.

Transcription:

2018/05/10 Series ure Sensor Instruction Sheet Thank you very much for choosing Delta DPA series pressure sensor. Please read this instruction sheet carefully before using your DPA. Keep this instruction sheet handy for quick reference. Warning DANGER! CAUTION! ELECTRIC SHOCK! DPA is a pressure measurement device. DO NOT use it out of its specification. Improper pressure or incorrect wiring may cause series injuries on staff or damages on other devices. 1. Keep away from high-voltage and high-frequency environment during the installation in case of interference. Prevent using the device in premises which contain: (a) dust or corrosive gas; (b) high humidity and high radiation; (c) shock and vibration. 2. DPA can only be used for air pressure measurement and should avoid corrosive, inflammable or toxic gas measurement. 3. Make sure the power supply is switched off when installing or dismounting DPA and the pressure source stops its action in case harms occur on human body and properties. 4. DO use parts compatible to the specification of the pressure pore for connection to avoid mistaken measurement or safety problems. 5. Before switching on the power supply, check the signal connection, e.g. the input voltage and polarity. Voltage that is too high may cause damages on DPA. 6. DO use dry cloth and DO NOT use acid or alkaline liquid to clean the device. Product Profile & Outline 1. Analog output indicator 6. UP key 2. Digital output 1 indicator 7. SET key 3. Digital output 2 indicator 8. DOWN key 4. ure/parameter display 9. Power supply and output terminals 5. SV/setup item display 10. ure input pore Contents in the pack: ure sensor, signal wire, unit sticker, instruction sheet Optional accessories: Panel mounting parts, metal mounting parts - 1 -

Ordering Information Series name 1 2 Measurable pressure range 3 Output types 4 ure pore types DPA: Delta DPA series pressure sensor 01: -100kPa ~ 100kPa 10: -100kPa ~ 1,000kPa N: NPN output + 4 ~ 20mA; P: PNP output + 4 ~ 20mA M: NPN output + 1 ~ 5V; Q: PNP output + 1 ~ 5V P: Outer pore PT 1/8, inner pore M5 N: Outer pore NPT 1/8, inner pore M5 G: Outer pore G 1/8, inner pore M5 Electrical Specifications Power supply ure measurement Display Output Pore size Shock immunity Voltage range Power consumption ure type Measurable range Max. durable pressure Accuracy Temperature inaccuracy Setup display Status display Display mode Cycle Number of outputs Transistor output Analog output Response time Output inaccuracy P N G 12 ~ 24V DC +/- 10% no isolation 40mA Max.; current output type 60mA Max. Non-corrosive gas, gauge type DPA01: -100kPa ~ 100kPa DPA10: -100kPa ~ 1,000kPa DPA01: 200kPa DPA10: 1,500kPa +/- 3% entire process +/- 2% entire process 2-line LCD display, 4 digits for measured value and 3.5 digits for setup display LCD output status display 3 colors for different modes 100ms, 250ms, 500ms, 1,000ms Built-in 2 NPN or PNP transistor digital outputs and 1 analog output NPN: Max. durable pressure 30V/100mA, residual voltage 1.5V PNP: Max. durable pressure 30V/100mA, residual voltage 1.5V 1 ~ 5V: Min. output load resistance 1,000Ω 4 ~ 20mA: Max. output load resistance 400Ω; linear inaccuracy < 2% entire process 2ms, 4ms, 10ms, 30ms, 50ms, 100ms, 250ms, 500ms, 1,000ms, 5,000ms Linear inaccuracy: < +/- 2% entire process Outer pore PT 1/8, inner pore M5 Outer pore NPT 1/8, inner pore M5 Outer pore G 1/8, inner pore M5 10 ~ 500Hz, 10mm 3 axes for 2 hours Vibration immunity Max. 100m/ s 2 3 axes 6 directions, 3 times each Ambient temperature Storage temperature 0 C ~ +50 C -20 C ~ +65 C Altitude < 2,000m Ambient humidity 35% ~ 80% RH (non-condensing) - 2 -

How to Set up Parameters Switching modes: DPA will be in the Measuring Mode when it is switched on, displaying PV and SV. for more than 2 seconds in this mode to switch to the Quick Setup Mode. for more than 4 seconds in the measuring mode to switch to Advanced Setup Mode. in the Quick Setup Mode or Advanced Setup Mode to return to the Measuring Mode. Setting up parameters: In the three modes, press or modify, use to modify the setting. once to select the parameter to set up. When you find the parameter to be set up Switching on DPA Advance Setup Mode > 4 secs. > 2 secs. Measuring Mode > 4 secs. > 4 secs. Quick Setup Mode Quick Setup Mode: Advanced Setup Mode: - 3 -

Measuring Mode: Quick Setup Mode Advanced Setup Mode Measuring Mode Set up OUT1 mode Set up auxiliary display (Change SV display method) Set up upper limit of OUT1 (Set OUT1 to hysteresis mode / window mode) Set up OUT2 mode Set up displayed speed Set up lower limit of OUT1 (Set OUT1 to hysteresis mode / window mode) - 4 -

Quick Setup Mode Advanced Setup Mode Measuring Mode OUT2 Set up /N.C. of OUT1 and Set up hysteresis SV of OUT1 (Set OUT1 to easy mode) Set up output response time Set up power saving mode Set up upper limit of OUT2 (Set OUT2 to hysteresis mode / window mode) Set up PV display color Set up switching color referencing output items Set up lower limit of OUT2 (Set OUT2 to hysteresis mode / window mode) Set up unit Set up code SV of OUT2 (Set OUT2 to easy mode) Return to set up OUT1 mode Returning to output setting Set up copy function Set up analog output switch Initial Setting Return to default settings Return to set up auxiliary display 1. Units: DPA provides many units for users, including kpa, kgf/cm 2, bar, psi, mmhg and inchhg. In the easy mode, you can press and find to set the unit to the desired one. 2. Output status: You can set up 2 output status in DPA, (normally open) and N.C. (normally closed). In the easy mode, you can press and fine to set up the output status for OUT1 and OUT2. 3. Response time: Referring to the time required for the pressure to reach output status. For example, 50 refers to once the pressure has reached the output status, it has to last for 50ms before the output starts to operate. In the easy mode, press and find. Use to set up the response time. Output Mode Setting There are 3 output modes in DPA: Easy, Hysteresis and Window 1. Easy Mode: Set up pressure P. When the pressure measured is bigger than (P + dp), the output will be ON. When the pressure measured is smaller than P, the output will be OFF. (See Figure 1: Output in Easy Mode) In the Measuring Mode, press and find (OUT1) and (OUT2). Use to set up P value. In the Advanced Setup Mode, press and find. Use to set up dp value. [Figure 1: Output in Easy Mode] - 5 -

2. Hysteresis Mode: Set up pressure Hi/Lo. When the pressure measured is bigger than the Hi value, the output will be ON. When the pressure measured is smaller than the Lo value, the output will be OFF. (See Figure 2: Output in Hysteresis Mode) In the Measuring Mode, press and find (OUT1 Hi), (OUT1 Lo), (OUT2 Hi) and (OUT2 Lo). Use to set up Hi/Lo values. [Figure 2: Output in Hysteresis Mode] 3. Window Mode: Set up pressure Hi/Lo. When the pressure measured is bigger than Hi or smaller than Lo, the output will be OFF. When the pressure measured is bigger than Lo and smaller than Hi, the output will be ON. (See Figure 3: Output in Window Mode) In the Measuring Mode, press and find (OUT1 Hi), (OUT1 Lo), (OUT2 Hi) and (OUT2 Lo). Use to set up Hi/Lo values. In the Advanced Setup Mode, press and find. Use to set up dp value. [Figure 3: Output in Window Mode] Note: Supposed the output is ON and the output status is set to (normally open), the output will then be off. If the output status is set to N.C (normally closed), the output will then be on. Supposed the output is OFF and the output status is set to, the output will then be on. If the output status is set to N.C., the output will then be off. Zero Returning In the "Measuring Mode, press together, and you will see. The zero returning will start. Release the keys to end the zero returning. Analog Output 1. Full range mode: When the input pressure starts to change, the analog output will change with the input. For example, supposed the range for input is -100kPa ~ 100kPa, and DPA reads -100kPa, the output will be 4mA or 1V. When DPA reads 100kPa, the output will be 20mA or 5V. (See Figure 4: Full range analog Output) 2. Change analog slop mode: When the DPA reads, the output will be 4mA or 1V. When DPA reads, the output will be 20mA or 5V. (See Figure 5: Change analog slop output) - 6 -

[Figure 4: Full range analog Output] S-L S-H [Figure 5: Change analog slop Output] Key Locking Function Lock On: and together for 2 seconds until is displayed. You will then see the display of pressure value (PV) and set value (SV). Lock Off: and together for 2 seconds until is displayed. You will then see the display of pressure value (PV) and set value (SV). Lock Display: any key in the key locking mode, and you will see the display of pressure value (PV) and key, and the PV and SV will return to original values. (SV). Release the Switching Colors In DPA, different output statuses can have different display colors. The output statuses for DPA are OUT1, OUT2, OUT1 and OUT2, OUT1 or OUT2. See below explanations for how to set: 1. Setting up output status: In the Measuring Mode, press for more than 4 seconds and release the key after you see. You are now in the Advanced Setup Mode. for 5 times and find the switching color referencing items (see Advanced Setup Mode chart). Use to select the referencing item you'd like. 2. Switching colors: In the Measuring Mode, press for more than 2 seconds to enter the Quick Setup Mode. for 4 times and find the parameter for setting up colors (see Quick Setup Mode chart). Use to select the color you d like. Note: OUT1 and OUT2 will be ON only when both OUT1 and OUT2 are ON; otherwise, it will be OFF. OUT1 or OUT2 will be OFF only when both OUT1 and OUT2 are OFF; otherwise, it will be ON. Copy Function DPA is able to copy the parameters in the master device to another slave device. 1. Hardware: Connect Pin 2 on master to Pin 3 on slave; Pin 3 on master to Pin 2 on slave; Pin 5 on master and slave to GND on power supply; Pin 1 on master and slave to +24V on power supply. 2. Software: a) Slave device: In the Measuring Mode, press for more than 4 seconds and release the key after you see. You are now in the Advanced Setup Mode. for 7 times and find the parameter for setting up the copy function (see Advanced Setup Mode chart). Use to select ( refers to Copy-Slave). b) Master device: In the Measuring Mode, press for more than 2 seconds and release the key after you see. You are now in the Advanced Setup Mode. for 7 times and find the parameter for setting up the copy function (see Advanced Setup Mode chart). Use to select ( refers to Copy-Master). Next, press for more than 2 seconds and return to the Measuring Mode. Now, you will see on the screen and on the slave device, indicating that the two devices have been connected. On, you will see numbering counting up, referring to the number of parameters transmitted successfully between the two devices. Once the copy of parameter succeeds, you will see on the master device and - 7 -

on the slave device. That the number at stays intact refers to the copy fails. After the copy is completed, switch off the two devices and connect them again to the power supply. Code DPA offers codes for the user to set up. In the Measuring Mode, press for more than 4 seconds and release the key after you see. You are now in the Advanced Setup Mode. for 6 times to find the parameter to set up codes (see Advanced Setup Mode chart). displays in turn. See the meanings of codes in the table below: Code 1 st digit 2 nd digit 3 rd digit 4 th digit OUT1 mode /N.C. OUT2 mode /N.C. Response time Color Referencing item for color 2ms OUT1 Easy Easy N.C. N.C. 4ms Red when OUT2 10ms ON OUT1 and OUT2 Hysteresis Hysteresis N.C. N.C. 30ms OUT1 or OUT2 50ms OUT1 Window Window N.C. N.C. 100ms Green OUT2 - - - - 250ms when ON OUT1 and OUT2 - - - - 500ms OUT1 or OUT2 - - - - 1,000ms OUT1 - - - - - Red OUT2 - - - - - OUT1 and OUT2 - - - - - Red OUT1 or OUT2 - - - - - OUT1 - - - - - OUT2 Green - - - - - OUT1 and OUT2 - - - - - OUT1 or OUT2 Code 6th digit 7th digit 8th digit ure unit Speed Auxiliary display Hysteresis setting kpa Standard 1 kgf/cm 2 250ms Off 2 bar Unit. 3 psi Standard. 4 mmhg 500ms Off 5 inchhg Unit 6 -- 1,000ms Standard 7-8 -

Code 6th digit 7th digit 8th digit ure unit Speed Auxiliary display Hysteresis setting - Off 8 - Unit - How to Install Dimension Panel: Use optional accessory DPA-PFKit. To install the fixing frame, you have to purchase the optional accessory: DPA-FMKit. Internal Circuit NPN (+ 1 ~ 5V output) NPN (+ 4 ~ 20mA output) PNP (+ 1 ~ 5V output) PNP (+ 4 ~ 20mA output) Terminals 1. Positive power supply input (brown) 2. Digital output 1 signal (black) 3. Digital output 2 signal (white) 4. Analog output signal (orange) 5. Negative power supply input (blue) - 9 -