Innovation of the Industrial Ethernet Switches X-100. Siemens AG 2018

Similar documents
Unmanaged Industrial Ethernet Switches

Unmanaged Industrial Ethernet Switches

Siemens AG Industrial Communication SCALANCE X. Industrial Ethernet Switches. Edition Brochure. siemens.com/switches

SCALANCE XB-000 SIMATIC NET. Industrial Ethernet switches SCALANCE XB-000. Introduction. Network topologies. Description of the device 3.

SCALANCE X-200 Managed Industrial Ethernet Switches siemens.com/x-200

HARTING scon Introduction and features

HARTING econ 3000 Introduction and features

SIMATIC NET. Industrial Ethernet switches SCALANCE XC-200. Introduction 1. Safety notices 2. Description of the device 3. Mounting 4.

114FX6. Phone: Fax: Web: -

SIMATIC NET. Industrial Ethernet switches SCALANCE XC-200. Introduction 1. Safety notices. Description of the device. Mounting 4.

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

6GK6041-6AT Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Serial Device Servers > RUGGEDCOM RS416 managed

gigabit industrial ethernet user manual Models , ,

Strengthen your network security with Industrial Security Appliances SCALANCE S siemens.com/scalance-s

Data sheet VIPA CPU 214PG (214-2BE03)

6GK6024-8GS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

Features and Benefits. Certifications

Data sheet VIPA CPU 214NET PG (214-2BT13)

ISE2016D Series Unmanaged Industrial Ethernet Switch

ISE2005D Series Unmanaged Industrial Fiber/Ethernet Switch

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0

ISE3018D Series Unmanaged Industrial Ethernet Switch

Features and Benefits. Certifications

2 Notes on SCALANCE XM-400 and SCALANCE XR Notes on SCALANCE XB-200, SCALANCE XC-200, SCALANCE XF-200BA, SCALANCE XP-200 and SCALANCE XR-300WG

LOGO! Logic Module & SITOP Power Supplies

OmniConverterTM. OmniConverter GPoE+/Sx KEY FEATURES. Unmanaged 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

harting Smart Network Infrastructure Selection Guide

Interface AP 146 5WG AB01 for Ethernet-UDP/IP. EIB Device. EIB Device. EIB Device

User Manual. MS657140X Industrial Fast Ethernet Switch 8x 10/100Base-TX

SCALANCE X-300 SIMATIC NET. Industrial Ethernet Switches SCALANCE X-300. Introduction 1. Safety instructions. Description. Assembling 4.

6GK6021-0PS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

6GK6023-0AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

6GK6091-0AT Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Serial Device Servers > RUGGEDCOM RS910 managed

Data sheet CPU 315SN/NET (315-4NE12)

Industrial Media Converters

LNP-800AGH-24 Series. Features INTRODUCTION DIMENSIONS

SIMATIC NET. Industrial Ethernet switches SCALANCE XC-100. Introduction 1. Safety notices 2. Description of the device 3. Mounting 4.

Data sheet CPU 315SN/NET (315-4NE12)

5-Port Industrial Ethernet Switch - DIN Rail Mountable

Features and Benefits. Certifications

ADAM-6520 Series. 5-port 10/100 Mbps Industrial Ethernet Switches. Features. Introduction. Specifications. Ordering Information.

Structure and Function

Power Supplies & Logic Modules

SIMATIC NET. SCALANCE Industrial Ethernet SCALANCE X- 100 and SCALANCE X-200 Product Line. Preface. Introduction. Network Topologies

SCALANCE XB-200 SIMATIC NET. Industrial Ethernet switches SCALANCE XB-200. Introduction. Safety notices. Description of the device.

User Manual. MS657208X Industrial Gigabit Ethernet Switch 8x 10/100/1000Base-T

SIMATIC S Central processing units

SIMOTION P PC-based SIMOTION P350-3

Supplementary Components Network transitions

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

SIMATIC NET. Industrial Ethernet switches SCALANCE XB-000. Introduction 1. Safety notices 2. Network topologies 3. Description of the device 4

PAS 300, PROFIBUS Slave Interface Module

Supplementary Components WirelessHART products

SIMATIC NET. Industrial Ethernet Switches SCALANCE X-300. Introduction 1. Safety instructions. Description. Assembling 4.

Accessories / 7XV5820

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

SIMATIC NET. Industrial Ethernet switches SCALANCE XB-000. Introduction 1. Safety notices. Network topologies. Description of the device 4.

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

Compact Redundancy Switch 2:1 RSCC-2

AC5160 SiPass integrated controller kit

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS1600 managed

6GK6022-8AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

6GK6050-0MM Transmission rate. Interfaces

Gazelle S1010i GE NMS-manageable Industrial Switch

Switch manual Models &

SIMATIC NET. Industrial Ethernet SCALANCE X-100 Approvals and markings 5. Introduction. Network topologies. Product properties

Opal5. 5 Port Entry-level Unmanaged DIN-Rail Switches. Opal5 unmanaged 5-port switch is specially designed for automation control applications.

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches Layer 3 / Routers > RUGGEDCOM RX1000 managed

SCALANCE X-200 SIMATIC NET. Industrial Ethernet Switches SCALANCE X-200. Preface. Functions. Description of the device.

Numerics INDEX. 10/100/1000 ports cable lengths 2-4, B-6 connecting to 2-38, B-43 described /100 ports

Compact Redundancy Switch 2:1 RSCC-2

BMCS CCX Cabinet. BMCS_CCX Cabinet is secured via a switchable 6A circuit breaker. Note the right selectivity ratio of your feeding.

Industrial Switches Industrial Switches

6GK6096-8AS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS900 managed

6GK6021-0MS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

SCALANCE X-100 SIMATIC NET. Industrial Ethernet switches SCALANCE X-100. Introduction 1. Network topologies. Description of the device.

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS8000 managed

ET 200S Motor Starters and Safety Motor Starters

4TX + 1MMFX Unmanaged Ethernet Switch

Data sheet CPU 315SB/DPM (315-2AG12)

ADAM-6541 Series. Ethernet to FiberOptic Converters. Features. Introduction. Specifications. Ordering Information

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS900 managed

Connections, displays and operating elements C D

10-Port Industrial USB 3.0 Hub - ESD and Surge Protection. StarTech ID: ST1030USBM

NEW. Phone: Fax: Web: -

Gigabit Ethernet Fiber Media Converter with Open SFP Slot

8B SLX300 Data Acquisition System

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

6GK6096-8MS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RS900 managed

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

EDS-G205-1GTXSFP/G308 Series

Data sheet CPU 315SB/DPM (315-2AG12)

SIMATIC NET. Industrial Ethernet switches SCALANCE X-100. Introduction 1. Network topologies 2. Description of the device 3.

Manual Elinx EIR408-T. 8 Port-10/100/1000 Unmanaged Din Rail Ethernet Switch

SPIDER III Standard Line Unmanaged Switch

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description

Gigabit Ethernet Fiber Media Converter - Compact - 850nm MM LC - 550m

Transcription:

Innovation of the Industrial Ethernet Switches X-100 Siemens AG 2018

Unmanaged Switches Technical Data CSM and SCALANCE Main features CSMs XB-000 X005 X-100 XC-100 XR-100WG Hardware Port version: electric RJ45 RJ45 RJ45 (with bracket) RJ45 (with bracket) RJ45 (with bracket) RJ45 Port version: optical ne SC ne ST/BFOC ST/BFOC, SC ne Temperature range 0 C to +60 C -10 C to +60 C 0 C to +65 C -20 C to +70 C -40 C to +70 C 0 C to +60 C Housing Plastic Plastic Metal/plastic Metal/plastic Metal/plastic Metal Mounting DIN rail/wall (LOGO!, CSM1277); S7-300 (CSM 377) DIN rail, wall S7-300, DIN rail, wall S7-1500, S7-300, DIN rail, wall S7-1500, S7-300, DIN rail, wall GBIT Yes Dimensions WxHxD [mm] Rack, DIN rail 45x100x75 (CSM 1200) 45x100x87 (XB008) 40x124x125 60x125x124 (X108) 60x147x125 (XC108) 482.6x 43.6x 127 Weight [g] 150 (CSM 1200) 180 (XB008) 550 780 (X108) 475 (XC108) 2700 Power consumption [ma] 70 120 (XB008) 80 140 (X108) 125 (XC108) 75 (AC version) Alarm contact Yes Yes Yes Broadcast storm protection Yes Redundant power supply Yes Yes Yes 1) Certificates ATEX/IECEx/Shipbuilding Yes / Yes / Yes Yes / Yes / Yes / Yes / Yes Yes / Yes / Yes Yes / Yes / Yes Yes / Yes / Page 2 1) Only certain versions

SCALANCE XC-100 - Comparison XC106-2 (ST) XC106-2 (SC) XC108 XC106-2 + XC108 XC116 XC124 X108PoE XC-100 X-100 + X101-1, X101-1LD X-100 X104-2 X106-1 X108 X112-2 X116 X124 X108PoE X101-1, X101-1LD Page 3

SCALANCE X104-2 X104-2 6GK5104-2BB00-2AA3 XC106-2 6GK5106-2BB00-2AC2 Advantages of XC106-2 compared with X104-2 Eight ports instead of six with the same width 4x RJ45 and 2x ST/BFOC (100 Mbit/s) Operating temperature -10ºC to 60ºC 60x125x124 Space requirements on S7-300 rail 160 ma 780 g 6x RJ45 and 2x ST/BFOC (100 Mbit/s) 60x147x125 S7-1500 approx. -11 mm above and +33 mm below 200 ma 500 g Page 4

SCALANCE X106-1 X106-1 6GK5106-1BB00-2AA3 XC106-2 6GK5106-2BB00-2AC2 Advantages of XC106-2 compared with X106-1 Eight ports instead of seven with the same width 6x RJ45 and 1x ST/BFOC (100 Mbit/s) Operating temperature -10ºC to 60ºC 60x125x124 Space requirements on S7-300 rail 150 ma 780 g 6x RJ45 and 2x ST/BFOC (100 Mbit/s) 60x147x125 S7-1500 approx. -11 mm above and +33 mm below 200 ma 500 g Page 5

SCALANCE X108 X108 6GK5108-0BA00-2AA3 XC108 6GK5108-0BA00-2AC2 Advantages of XC108 compared with X108 Eight ports with bracket Lower power consumption 8x RJ45 (100 Mbit/s) Operating temperature -20ºC to 70ºC 60x125x124 Space requirements on S7-300 rail 140 ma 780 g 8x RJ45 (100 Mbit/s) 60x147x125 S7-1500 approx. -11 mm above and +33 mm below 125 ma 475 g Page 6

SCALANCE X112-2 X112-2 6GK5112-2BB00-2AA3 Substitute solution XC106-2 + XC108 6GK5106-2BB00-2AC2 + 6GK5108-0BA00-2AC2 + 6XV1870-3QE50 Advantages of the substitute solution compared with X112-2 16 ports instead of 14 with the same width Lower power consumption + 8x RJ45 (100 Mbit/s) Operating temperature -10ºC to 70ºC 120x125x124 Space requirements on S7-300 rail 450 ma 1100 g 14x RJ45 and 2x SC (100 Mbit/s) (60+60) x147x125 S7-1500 approx. -11 mm above and +33 mm below (200+125) = 325 ma (500+475) = 975 g Page 7

SCALANCE X116 X116 6GK5116-0BA00-2AA3 XC116 6GK5116-0BA00-2AC2 Advantages of XC116 compared with X116 16 ports with bracket Lower power consumption 16x RJ45 (100 Mbit/s) Operating temperature -20ºC to 70ºC 120x125x124 Space requirements on S7-300 rail 300 ma 1100 g 16x RJ45 (100 Mbit/s) 120x147x125 S7-1500 approx. -11 mm above and +33 mm below 225 ma 775 g Page 8

SCALANCE X124 X124 6GK5124-0BA00-2AA3 XC124 6GK5124-0BA00-2AC2 Advantages of XC124 compared with X124 Lower power consumption Narrower design 24x RJ45 (100 Mbit/s) Operating temperature -20ºC to 70ºC 180x125x124 Space requirements on S7-300 rail 450 ma 1500 g 24x RJ45 (100 Mbit/s) 120x147x125 S7-1500 approx. -11 mm above and +33 mm below 325 ma 850 g Page 9

Comparison of Mounting Types Position on the DIN rail Position on the S7-300 rail X-100 XC-100 X-100 XC-100 XC-100 is positioned as follows compared with X-100: -11 mm above +33 mm below XC-100 is positioned as follows compared with X-100: +18 mm above +4 mm below Page 10