Datasheet SIMATIC HMI KP1500 COMFORT, COMFORT PANEL, KEY OPERATION, 15" WIDESCREEN-TFT-DISPLAY, 16 MIL. COLORS, PROFINET INTERFACE, MPI/PROFIBUS DP INTERFACE, 24 MB USER MEMORY, WINDOWS CE 6.0, CONFIGURABLE FROM WINCC COMFORT V11 SP2 Product type designation Display Design of display TFT Screen diagonal 15.4 in Display width 331.2 mm Display height 207 mm Number of colors 16 777 216 Resolution (pixels) Horizontal image resolution 1 280 Vertical image resolution 800 Backlighting MTBF backlighting (at 25 C) 80 000 h Dimmable backlight ; 0-100 % Control elements Keyboard Function keys Number of function keys 36 Keys with LED System keys Numeric/alphabetical input Numeric keyboard Alphanumeric keyboard Touch operation Design as touch screen Page 1/10 12.02.2015 Copyright Siemens AG
Expansions for operator control of the process DP direct LEDs (LEDs as S7 output I/O) F1...Fx 36 Direct keys (keys as S7 input I/O) F1...Fx 36 Installation type/mounting Mounting in portrait format possible Mounting in landscape format possible Mounting position maximum permissible angle of inclination without external ventilation Supply voltage Type of supply voltage Rated value (DC) permissible range, lower limit (DC) permissible range, upper limit (DC) Input current Current consumption (rated value) Inrush current A²s Power Power consumption, typ. Processor Processor type Memory Flash RAM Usable memory for user data Type of output Info LED Power LED Error LED Acoustics Buzzer Speaker Time of day Clock Hardware clock (real-time clock) Software clock Battery-backed Synchronizable vertical 35 DC 24 V 19.2 V 28.8 V 1.5 A 0.5 A² s 36 W X86 24 Mbyte ; Back-up duration typically 6 weeks Page 2/10 12.02.2015 Copyright Siemens AG
Interfaces Number of RS 485 interfaces 1; RS 422/485 combined Number of USB interfaces 2; USB 2.0 Number of USB Mini B interfaces 1; 5-pole Number of 20 ma interfaces (TTY) 0 Number of RS 232 interfaces 0 Number of RS 422 interfaces 1 Number of parallel interfaces 0 Number of other interfaces 0 Number of SD card slots 2 With software interfaces Industrial Ethernet Number of industrial Ethernet interfaces 3 Industrial Ethernet status LED 3 Number of ports of the integrated switch 2 Protocols PROFINET PROFINET IO IRT MRP PROFIBUS MPI Protocols (Ethernet) TCP/IP DHCP SNMP DCP LLDP WEB characteristics HTTP HTTPS HTML XML CSS Active X JavaScript Java VM Further protocols CAN MODBUS Supports protocol for EtherNet/IP ; As of WinCC V12 Page 3/10 12.02.2015 Copyright Siemens AG
EMC Emission of radio interference acc. to EN 55 011 Limit class A, for use in industrial areas Limit class B, for use in residential areas Degree and class of protection IP (at the front) Enclosure Type 4 at the front Enclosure type 4x at the front IP (rear) Standards, approvals, certificates CE mark KC approval culus RCM (formerly C-TICK) Marine approval Germanischer Lloyd (GL) American Bureau of Shipping (ABS) Bureau Veritas (BV) Det rske Veritas (DNV) Lloyds Register of Shipping (LRS) Nippon Kaiji Kyokai (Class NK) Polski Rejestr Statkow (PRS) Use in hazardous areas ATEX Zone 2 ATEX Zone 22 IECEx Zone 2 IECEx Zone 22 culus Class I Zone 1 culus Class I Zone 2, Division 2 FM Class I Division 2 IP65 IP20 Ambient conditions Ambient temperature in operation Operation (vertical installation) in vertical mounting position, minimum 0 C in vertical mounting position, maximum 50 C; (55 C, see entry ID:64847814) Operation (max. tilt angle) at maximum tilt angle, minimum 0 C at maximum tilt angle, maximum 40 C Operation (vertical installation, portrait format) in vertical mounting position, minimum 0 C in vertical mounting position, maximum 40 C Page 4/10 12.02.2015 Copyright Siemens AG
Operation (max. tilt angle, portrait format) at maximum tilt angle, minimum 0 C at maximum tilt angle, maximum 40 C Storage/transport temperature Min. -20 C max. 60 C Relative humidity Operation, max. 90 % Operating systems Pre-installed operating system Windows CE proprietary Configuration Message indicator Alarm logging system (incl. buffer and acknowledgment) Process value display (output) Process value default (input) possible Recipe administration Configuration software STEP 7 Basic (TIA Portal) STEP 7 Professional (TIA Portal) WinCC flexible Compact WinCC flexible Standard WinCC flexible Advanced WinCC Basic (TIA Portal) WinCC Comfort (TIA Portal) WinCC Advanced (TIA Portal) WinCC Professional (TIA Portal) ; V11 SP2 or higher ; V11 SP2 or higher ; V11 SP2 or higher Languages Online languages Number of online/runtime languages 32 Languages Languages per project 32 Languages D GB F I E Chinese traditional Page 5/10 12.02.2015 Copyright Siemens AG
Chinese simplified DK FIN GR J KP / ROK NL N PL P RUS S CZ SK TR H Functionality under WinCC (TIA Portal) Libraries Applications/options Internet Explorer Pocket Word Pocket Excel PDF Viewer Media Player SIMATIC WinCC Sm@rtServer SIMATIC WinCC Audit Number of Visual Basic Scripts Task planner time-controlled task-controlled Help system Number of characters per info text 320 Message system Number of alarm classes 32 S7 alarm number procedure System messages HMI System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.) Number of characters per message 80 Number of process values per message 8 Acknowledgment groups Page 6/10 12.02.2015 Copyright Siemens AG
Message indicator Message buffer Number of entries 1 024 Circulating buffer retentive maintenance-free Recipe administration Number of recipes 500 Data records per recipe 1 000 Entries per data record 2 000 Size of internal recipe memory 4 Mbyte Recipe memory expandable Variables Number of variables per device 4 096 Number of variables per screen 400 Limit values Multiplexing Structs Arrays Images Number of configurable images 750 Permanent window/default Global image Start screen configurable Image selection by PLC Image number in the PLC Image objects Number of objects per image 600 Text fields I/O fields Graphic I/O fields (graphics list) Symbolic I/O fields (text list) Date/time fields Switches Buttons Graphic view Icons Geometric objects Complex image objects Number of complex objects per screen 40 Alarm view Page 7/10 12.02.2015 Copyright Siemens AG
Trend view User view Status/control Sm@rtClient view Recipe view f(x) trend view System diagnostics view Media Player Bar graphs Sliders Pointer instruments Analog/digital clock Lists Number of text lists per project 500 Number of entries per text list 500 Number of graphics lists per project 500 Number of entries per graphics list 500 Archiving Number of archives per device 50 Number of entries per archive 50 000 Message archive Process value archive Archiving methods Sequential archive Short-term archive Memory location Memory card USB memory Ethernet Data storage format CSV TXT RDB Security Number of user groups 50 Number of user rights 32 Number of users 50 Password export/import SIMATIC Logon Logging through printer Alarms Page 8/10 12.02.2015 Copyright Siemens AG
Report (shift log) Hardcopy Electronic print to file ; pdf, html Character sets Keyboard US American (English) Character sets Tahoma Arial Courier New WinCC flexible Standard Ideographic languages Font size freely scalable Additional character sets can be loaded Transfer (upload/download) MPI/PROFIBUS DP USB Ethernet using external storage medium Process coupling S7-1200 S7-1500 S7-200 S7-300/400 LOGO! Win AC SINUMERIK ; with SINUMERIK option package SIMOTION Allen Bradley (EtherNet/IP) Allen Bradley (DF1) Mitsubishi (MC TCP/IP) Mitsubishi (FX) OMRON (FINS TCP) OMRON (LINK/Multilink) Modicon (Modbus TCP/IP) Modicon (Modbus) OPC UA Client OPC UA Server Service tools/configuration aids Clean screen Touch calibration Page 9/10 12.02.2015 Copyright Siemens AG
Backup/restore Backup/Restore automatically Simulation Device switchover Delta transfer I/O / Options I/O devices Printer MultiMediaCard SD card USB memory Network camera Mechanics/material Type of housing (front) plastic aluminum Stainless steel Dimensions Width of the housing front Height of housing front Mounting cutout, width Mounting cutout, height Device depth 483 mm 310 mm 450 mm 291 mm 75 mm Weights Without packaging 5.4 kg last modified: 11.02.2015 Page 10/10 12.02.2015 Copyright Siemens AG