AX3000 Platine Terminal Ethernet TCP/IP

Similar documents
AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP

LS8000 USER MANUAL. Kitchen Display Station Controller. with Android TM

CPU-1850 Cable-set Rev. 4.0 Apr COPYRIGHT Eurotech S.p.A. All Rights Reserved.

CPU-145x & CPU-146x Cable-sets Rev. 4.0 Mar COPYRIGHT Eurotech S.p.A. All Rights Reserved.

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

SoundwebTM. Installation Guide

Cable and Port Specifications

NetBiter Serial Server User Manual

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

Leased-Line Extenders over IP

Installing the Cisco ATA

User Manual Anybus Serial Server

8 / 16 port combo KVM Switch 1+1 Console 8 / 16 port combo KVM Switch User Manual

Technology Corporation. ADDERLINK X SERIES X2-MultiScreen

F1000 User's Manual. (Version: V1.01)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

If anything is damaged or missing, contact your dealer.

Hardware Installation Guide Installation (x3350)

Appendix A Cable Pinouts

Quick Start Guide. GV-Video Server

CE-1000M CAT5 Module User Manual

Parallel to Serial and Serial to Parallel Converter CE Model 232SPS2 Documentation Number 232SPS2-3903m

Quick Start Guide. GV-Video Server. 1 Introduction. Packing List

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

Cable Pinouts. SRP I/O Module

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Cable and Port Specifications

Axel Remote Management Version 2

SYNERGY GLOBAL INC. Toll Free : Fax :

TIME SERVER NETSILON. Quick start.

The specifications for the Cisco 7304 router are listed in Table A-1.

INDUSTRIAL POE SWITCH

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

DVI KVM Switch user manual Model

Quick Start Guide. GV-Video Server

AXEL Platine Terminal AX3000 Models 65, 70, 75, 80 and 85

EasySYNC Ltd. USB to Serial Converters Manual

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual

PROJECTOR MODEL SETUP MANUAL

SMK585 1U rackmount. With 8 Ports KVM Switch

OnRISC. OnRISC Baltos ir 2110

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Connector and Cable Specifications

Cable and Port Specifications

VPN Routers. OnSite 2800 Series. Quick Start Guide

User s manual 19 1U RACKMOUNT CONTROL CENTER. Rack-KVM in-1 TABLE OF CONTENTS INTRODUCTION... (KVM switch, Keyboard, LCD display, touch pad)

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

Installation Instructions for UL Rev A

CAT.5 COMBO-KVM SWITCH 8-PORT/16-PORT

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

LevelOne. User Manual KVM-0831/KVM /16-Port Combo KVM Switch w/ Expansion Slot. Ver

Lantech I(P)GS-0008B. 8 10/100/1000T (PoE at/af) Industrial Unmanaged Ethernet Switch I(P)ES-0008B

DGH A3000 Configuration Guide For use with DGH Modules

Connector and Cable Specifications

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Itona DxxS Hardware User s Guide

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

Itona TC73yy Hardware User s Guide

T1/E1 Channelized Gigabit Router

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

G.SHDSL IAD. iprocketlink Model Quick Start Guide

C-Bus Pascal Automation Controller

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

TWO-CONSOLE (One Local, One CAT5 Remote) 8 port / 16 port 19 RACK MOUNTABLE PS/2 KVM SWITCH USER S MANUAL

DA-820 Series Quick Installation Guide

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

INTRODUCTION...1 FEATURES...1 PACKAGE CONTENTS... 1 TECHNICAL SPECIFICATIONS...2 SYSTEM REQUIREMENT..3 CABLE DIAGRAMS.3 PRODUCT DETAILS 4

DT Desktop Series

ipanel CONTROL TECHNOLOGY CORPORATION ipanel Installation Guide and Specifications ipanel Installation Guide

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

AXEL Platine Terminal Ethernet TCP/IP Models

DMS / DLS / VNS Recorders

HEC. General Operating, Maintenance and Installation Manual

Extension module for graphic Web functions for one automation station

CPU-1210 Cable-set Rev. 4.0 Apr COPYRIGHT Eurotech S.p.A. All Rights Reserved.

Programmable Keyboard SERIES 8031 S

4 / 8 / 16 PORT PS2 KVM SWITCH USER S MANUAL

Extension module for BACnet over Ethernet / IP and graphic Web functions

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

MGate MB3000 Modbus Gateway User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

EasySYNC Ltd. USB to Serial Converters Manual

FSM-510G Series Ethernet Management Switch Quick Start Guide

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

Venus Series Stand Alone & Modular Combo-free KVM Switch User Manual

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

Extension module for Web functions generic

AXEL Platine Terminal AX3000 Models 65, 70, 75, 80 & 85

Smart CAT5 Switch 16 IP Installation Guide

Overview of the Cisco 2524 and Cisco 2525 Routers

Sender Receiver Sender

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

Transcription:

AX3000 Platine Terminal Ethernet TCP/IP Model 75E Installation Guide January 003 - Ref: I75EE0303-1 Model AX3000/M75E

The reproduction of this material, in part or whole, is strictly prohibited. For additional information, please contact: 14 Avenue du Québec Bât. K EVOLIC - BP 78 9196 Courtabœuf cedex - FRANCE Tel.: 33 1.69.8.7.7 Fax: 33 1.69.8.8.04 Email: info@axel.com The information in this document is subject to change without notice. AXEL assumes no responsibility for any errors that may appear in this document. All trademarks and registered trademarks are the property of their respective holders. - 003 - AXEL - All Rights Reserved.

1 - SAFETY NOTICES... 1 - INSTALLATION....1 - DESCRIPTION.... - INSTALLATION.....1 - Monitor and keyboard... 3.. - Ethernet Connection... 4..3 - Auxiliary Ports... 5..4 - AC Power Connection... 5..5 - Power On... 6 3 - QUICK INSTALLATION... 7 4 - CONNECTOR PIN ASSIGNMENTS... 10 4.1 - ETHERNET PORT RJ45 (100BT)... 10 4. - SERIAL PORTS AUX1 AND AUX (RJ45)... 11 4..1 - RJ45-DB9 and RJ45-DB5 adaptors... 1 4.. - Peripheral RJ45 cables... 1 4.3 - KEYBOARD INTERFACE... 13 4.4 - MOUSE INTERFACE... 13 4.5 - VIDEO INTERFACE... 14 4.6 - PARALLEL INTERFACE... 15 5 - PROBLEM SOLVING... 16

The AXEL AX3000 Terminal is based on a modular concept. VGA / SVGA standard monitor AX3000 standard keyboard The AX3000 is totally designed and manufactured by Axel. The terminal's electronics is contained within a slim base unit which provides connections for a VGA or SVGA monitor, keyboard, system printer, serial devices and Ethernet network.

Safety Notices 1 - SAFETY NOTICES Check AC voltage from the wall outlet is inside 0-40 Volts range. The wall outlet used must be reached easily and as nearest as possible to the AX3000 Platine Terminal to connect or disconnect the power cord. Make sure to power off all devices before connecting or disconnecting any one of them (monitor VGA cable, keyboard and serial or parallel cables). In order to ensure compliance with European EMC regulations (EN 550), it is required that shielded cables be used when interfacing with other devices (peripherals or computers). To install and connect the keyboard and the monitor, refer to the respective supplier installation manuals. Installation Guide - Model 75E 1

Installation - INSTALLATION This chapter provides information and instructions to install the AX3000 Model 75E..1 - DESCRIPTION A green LED, located on the face plate, indicates when the AX3000 is powered on. The AX3000 has the following connectors and switches on the rear panel: - one power switch, - one connector for the external power transformer cord, - one connector for a VGA or SVGA monitor (colour or monochrome), - one Mini-DIN connector for an AT/PS style keyboard, - one PS/ mouse connector, - two auxiliary serial ports: RJ45 (AUX1 and AUX), - one auxiliary parallel port: female 5-pin (PARALLEL), - one TCP/IP port: RJ45 (100BT). 1VAC SVGA KEYB AUX1 AUX PARALLEL 10BT I O Power Switch VGA Monitor Mouse Port External Power Connector Keyboard Port Serial Ports Parallel Port Ethernet Port Low Voltage Connectors. - INSTALLATION For safety reasons and to prevent component damage, do not apply power to the AX3000 before connecting or disconnecting any cable. Do not plug in the AX3000 power cord until all other connectors have been plugged in. Installation Guide - Model 75E

Installation Make sure the AX3000 and monitor power switches are in the OFF (0) position before connecting cables to the back panel. 1 : On 0 : Off..1 - Monitor and keyboard Plug in the VGA monitor cable, the AT-compatible keyboard cable and the optional mouse cable to the dedicated connectors on the terminal back panel: 1VAC SVGA KEYB AUX1 AUX PARALLEL 10BT I O If your keyboard is fitted with a DIN connector, connect it using a DIN-to-Mini- DIN adaptor. To comply with EMC regulations, the VGA signal cable must be shielded. Installation Guide - Model 75E 3

Installation Note: when the terminal is installed in a cabinet or rack, it is essential to maintain air circulation around the VGA/SVGA monitor... - Ethernet Connection Plug the RJ45 connector on the end of the 100Base-T cable into the socket labelled 100BT on the back of the AX3000 (see chapter 4.1 for technical specifications and pin assignments). 1VAC SVGA KEYB AUX1 AUX PARALLEL 10BT I O ETHERNET ETHERNET CONNECTION INDICATOR LIGHT: This indicator is a green LED, located next to the RJ45 connector on the rear of the terminal. It lights to indicate a satisfactory connection to the Ethernet circuit (server or hub). Note: if the LED does not light, check that the Ethernet connector and cable both comply with the specifications listed in chapter 4.1. 4 Installation Guide - Model 75E

Installation..3 - Auxiliary Ports AX3000 Models 75E have three auxiliary ports as a standard feature: - MAIN-AUX1: bi-directional serial port, RJ45 connector, - AUX: bi-directional serial port, RJ45 connector, - PARALLEL: parallel port, female 5-pin connector. Cable pin assignments are listed in chapter 4. To comply with EMC regulations, the serial cables must be shielded...4 - AC Power Connection An Axel external power transformer must be used, to convert mains voltage at the wall outlet to low voltage for the AX3000 Model 35. Before connecting, make sure the AX3000 and monitor power switches are both in the OFF (0) position. Plug the plastic moulded cord connector of the external power transformer (ref. AXP/EC9.8) to the AX3000 power connector. Then plug the transformer into the AC wall outlet. 1VAC SVGA KEYB AUX1 AUX PARALLEL 10BT I O Warning: Only use the Axel external transformer supplied with your AX3000 Model 75E. Use of any other transformer may cause permanent damage to the AX3000. Installation Guide - Model 75E 5

Installation Plug the monitor power cable into a grounded AC mains power socket. The monitor does not require low voltage power...5 - Power On The power switch on the rear panel controls the power supply to the AX3000. 1 : On 0 : Off The green LED on the front of the terminal should light, and a single audible beep should be heard, to indicate that the AX3000 terminal is powered up and operating correctly. To indicate correct keyboard initialisation after power-up, the keyboard indicator lights 'Num lock', 'Caps lock' and 'Scroll lock' should flash twice. The green LED on the right side of the RJ45 connector on the back panel remains lit, to indicate a satisfactory Ethernet connection. If the terminal does not function as described above (for example if it emits a continuous tone sound, or two beeps, or if an error message is displayed on the screen) refer to chapter 5. If the terminal still does not operate properly, call your service representative. 6 Installation Guide - Model 75E

Quick Installation 3 - QUICK INSTALLATION This chapter describes the quick set-up procedure for the TCP/IP Platine terminal. The following command sequence is used to enter the AX3000 Set-Up: All the AX3000 set-up parameters (network environment, session settings and auxiliary port settings) can be adjusted through this set-up. For more information, refer to the guide: TCP/IP AX3000 - User's Manual. But, for a fast and reliable installation, the AX3000 provides a quick set-up function. This quick set-up function is dedicated to a typical environment: - only one host, - an optional router, - all the virtual terminals have the same settings, - a lpd or a Prt550 printer is available. To enter the quick set-up, select [Configuration] [Quick Set-up] and press <CR>. A warning message is displayed, press <CR> to continue. Installation Guide - Model 75E 7

Quick Installation The quick set-up dialog box is displayed: Note: this box is automatically called when the AX3000 is powered up for the first time. Quick set-up parameters: - Keyboard: keyboard nationality. - Number of sessions: maximum number of sessions. These sessions are automatically associated with the host described above. - Configuration: virtual terminal settings. This choice is selected from a list. - Enable DHCP: two possible values: - yes: the DHCP protocol is run when the set-up is exited. The DHCP function is automatically set to get both the AX3000 IP address and other DHCP options (netmask, default router, etc). - no: parameters are manually entered (in addition, AX3000 Name (FQDN) is not accessible). - AX3000 IP address: it must be entered if DHCP is disabled. - Default router: optional router IP address. - 1st DNS Server IP Address: optional DNS server IP address - AX3000 Name (FQDN): this optional parameter (see appendix A.5) allows an AX3000 to be identified by this name if both a DHCP server and a Dynamic DNS server are available. 8 Installation Guide - Model 75E

Quick Installation - Host Name: if the IP address of a host is not given, this name will be resolved by DNS (if a DNS server is given). - Host IP address: if this field is left blank, DNS will be used to resolved the hostname. - Enable: Configuring printers attached to AX3000. If Pre-defined Configuration is set to 550 and a hostname is defined, PRT550 (telnet printing) is automatically selected. If not LPD is the default printing system. This setting can easily be changed through interactive set-up. - Printer Name (accessible only if "Enable" is set): this is the printer name at the operating system level. - Manufacturer Type and Model (accessible only with Prt550): printer type and model. After confirmation, all the AX3000 set-up parameters are updated. Installation Guide - Model 75E 9

Connector Pin Assignments 4 - CONNECTOR PIN ASSIGNMENTS This chapter describes the connector pin assignments for the different ports of the AX3000 Model 75E. 4.1 - ETHERNET PORT RJ45 (100BT) Recommended wiring is a non-shielded twisted-pair cable (UTP), category 3 or 5 1 3 4 5 6 7 8 RJ45 connector (Model 75E rear panel) Note: the maximum length of a 100Base-T cable is 100 meters (330 feet). a - AX3000 Connected to a HUB HUB RX+ RX- TX+ TX- Pin Signal Name Direction 1 TX+ (Transmitted Data) Input TX- (Transmitted Data) Input 3 RX+ (Received Data) Output 4 --- --- 5 --- --- 6 RX- (Received Data) Output 7 --- --- 8 --- --- 1< (*) 1 < 3 6 > 3 > 6 AX 3000 Model 65E TX+ TX- RX+ RX- (*) see the note on next page 10 Installation Guide - Model 75E

Connector Pin Assignments b - AX3000 Connected to an Ethernet Controller Ethernet Board TX+ 1 1 TX- RX+ RX- 3 < 6 < > 3 > 6 AX3000 Model 65E TX+ TX- RX+ RX- IMPORTANT: the cable is composed of two twisted pairs. The two wires TX+ / TX- must belong to one pair and the two wires RX+ / RX- must belong to the other pair. 4. - SERIAL PORTS AUX1 AND AUX (RJ45) These serial ports are bi-directional ports (for printers, bar-code readers, touch screens, etc): 1 3 4 5 6 7 8 AUX1 and AUX connectors (Model 75E rear panel) Pin Signal Name Direction 1 RTS (Request To Send) Output DTR (Data Terminal Ready) Output 3 RD (Received Data) Input 4 SG (Signal Ground) --- 5 CTS (Clear to Send) Input 6 TD (Transmitted Data) Output 7 --- --- 8 DCD (Data Carrier Detected) Input Installation Guide - Model 75E 11

Connector Pin Assignments 4..1 - RJ45-DB9 and RJ45-DB5 adaptors Pin assignment for an adaptor between the peripheral cable and the AX3000 RJ45 connector: AX3000 - RJ45 DTR RD SG CTS TD DTR RD SG CTS TD 3 4 5 6 3 4 5 6 < < AX3000 - RJ45 < < Adaptor - male 9-pin > > 4 5 8 3 0 3 7 5 DTR RD SG CTS TD Adaptor - DTE female 5-pin > > DTR RD SG CTS TD 4.. - Peripheral RJ45 cables Pin assignment for a direct connection of a peripheral to the AX3000 RJ45 connector: AX3000 - RJ45 DTR RD SG CTS TD 3 4 5 6 < < Peripheral - female 9-pin > > 6 3 5 4 DSR TD SG DTR RD 1 Installation Guide - Model 75E

Connector Pin Assignments AX3000 - RJ45 DTR RD SG CTS TD 3 4 5 6 < < Peripheral - DTE male 5-pin > > 6 7 0 3 DSR TD SG DTR RD 4.3 - KEYBOARD INTERFACE The AX3000 keyboard interface is a Mini-DIN connector. To connect a keyboard which has a DIN connector, use a DIN-to-Mini-DIN adaptor: 4 6 1 5 3 Pin Signal name 1 Data --- 3 Ground 4 + 5 V DC 5 Clock 6 --- 4.4 - MOUSE INTERFACE The AX3000 mouse interface is a Mini-DIN connector: 4 6 1 5 3 Pin Signal name 1 Data --- 3 Ground 4 + 5 V DC 5 Clock 6 --- Installation Guide - Model 75E 13

Connector Pin Assignments 4.5 - VIDEO INTERFACE The AX3000 video interface is VGA and SVGA compatible: 5 4 3 1 10 9 8 7 6 15 14 13 1 11 VGA/SVGA connector (Model 75E, rear panel) Pin Signal name 1 Red Green 3 Blue 4 --- 5 Ground 6 Ground 7 Ground 8 Ground 9 Ground 10 Ground 11 --- 1 --- 13 Horizontal sync. 14 Vertical sync. 15 --- 14 Installation Guide - Model 75E

Connector Pin Assignments 4.6 - PARALLEL INTERFACE The Platine terminal Model 75E is equipped with a parallel port. 13 1 11 10 9 8 7 6 5 4 3 1 5 4 3 1 0 19 18 17 16 15 14 Parallel connector (Model 75E, rear panel) Pin Signal Name 1 Strobe Data 0 3 Data 1 4 Data 5 Data 3 6 Data 4 7 Data 5 8 Data 6 9 Data 7 10 ACK (Acknowledge) 11 Busy 1 PE (Paper End) 13 SLCT (Select) 14 Auto Feed XT 15 Error 16 Init 17 SLCT IN 18 Ground 19 Ground 0 Ground 1 Ground Ground 3 Ground 4 Ground 5 Ground Installation Guide - Model 75E 15

Problem Solving 5 - PROBLEM SOLVING This chapter describes some of the problems, that may occur during installation of the AX3000 Model 75E, and offers possible solutions. - THE VGA MONITOR VERTICAL SYNC IS LOST Care must be taken with the VGA monitor. The default VGA frequency used by the AX3000 is 7 Hertz. If the VGA monitor does not support this frequency, the vertical sync will be lost. To fix this problem, either use a more modern monitor or modify the AX3000 VGA frequency: - GREEN FRONT INDICATOR DOESN'T LIGHT, OR NO BEEP WHEN YOU PRESS POWER SWITCH Check there is power at the wall outlet and power cord connections. - CONTINUOUS TONE SOUNDS AFTER THE TERMINAL HAS BEEN SWITCHED ON This alarm indicates a hardware failure. Report the problem to your service representative. - AFTER THE TERMINAL HAS BEEN SWITCHED ON, THE MESSAGES 'NO ETHERNET BOARD PRESENT' AND 'CANNOT ATTACH ETHERNET BOARD' APPEAR This message indicates a hardware failure. Report the problem to your service representative. 16 Installation Guide - Model 75E

Problem Solving - A DOUBLE-BEEP SOUNDS After switching on the terminal, a double beep may sound, a few seconds after the normal first beep. This signal indicates that keyboard initialisation has failed. Check the keyboard connection to the terminal back panel. It is possible for the keyboard to function correctly, despite this double-beep signal. As a quick test of keyboard operation, enter set-up mode by pressing the <Ctrl><Alt><Esc> keys simultaneously. If set-up mode is working, you can ignore the double beep signal and use the terminal normally. - ETHERNET CONNECTION INDICATOR DOES NOT LIGHT This indicator is the green LED located next to the network connector on the Model 75E terminal back panel. Failure to light when the terminal is switched on may be due to any of the following: - the Ethernet cable is disconnected at the far end, - the device (host or hub), to which the network cable is connected, is not switched on, - there is a fault on the Ethernet cable or the cable is wired with incorrect pin assignments. - NO LOGIN WHEN THE 'CONNECTING...' MESSAGE IS DISPLAYED Check the Ethernet cables are correctly connected and networked devices (hubs or servers) are switched on. No connection (and no login) can also be due to a wrong terminal setting during the TCP/IP set-up (for example a wrong IP address). Installation Guide - Model 75E 17

Problem Solving - INCORRECT APPEARANCE OF SOFTWARE DISPLAYED ON THE AX3000 Check the values of parameters set using Terminal Set-Up. Check that the correct terminal emulation has been chosen. Check that the TERM environment variable (for the current UNIX shell) corresponds to the emulation selected for the terminal (in AX3000 Set-Up). - THE CONNECTED PRINTER DOES NOT WORK Check that the cable pin assignment is correct and test the printer in local mode by selecting the [TEST] button within the auxiliary port dialog box. 18 Installation Guide - Model 75E

14 Avenue du Québec Bât. K EVOLIC - BP 78 9196 Courtabœuf cedex - FRANCE Tel.: 33 1.69.8.7.7 Fax: 33 1.69.8.8.04 Email: info@axel.com