Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Similar documents
Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

IEC/EN/UL60950 & CE certified, EN55032 Class B

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Universal input VAC <150mW No load power consumption

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

Packaging (5) Protection (3) Isolation Voltage (4)

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Packaging (4) Isolation Voltage (3) nom. Output Voltage

RM- S/_ Protection (3) Isolation Option (4) Single

Protection (3) alternative Pinning Option (4) Single or Dual

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

RO- S/_ Protection (3) Isolation Option (4) Single

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Vin= 24VDC Vout= full load with normal start-up time, no external components with <1 second start-up time + diode protection circuit

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Over Current and Over Voltage Protection No Minimum Load Required

Features. Regulated Converters. RP10-AW 10 Watt 1 x1 Single & Dual Output RP10- _AW/_- DC/DC Converter

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Fixed Operating Frequency Six-Sided Continuous Shield

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 84% Fixed Operating Frequency Six-Sided Continuous Shield

Package (4) Control Logic (3)

Universal Power Supplies

2:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 88% Ultraminiature Open Frame SMD No Minimum Load Required

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 89% Six-Sided Continuous Shield

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable)

R0.5S_D ECONOLINE. Features. 0.5 Watt SMD Isolated Single or Dual Output. Derating-Graph (Ambient Temperature) DC/DC-Converter with 3 year Warranty

Enclosed Power Supplies

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

Features. LED Driver. RCOB Constant Current Active PFC Single Output. AC/DC Converter

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

C B. Models. Operating up to 5000m altitude 5 year product warranty

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM40-G)

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

Constant Voltage Mode

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

FEATURES. Nominal Output Voltage and Current

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Environmental. Electrical Specifications at 25 O C E Output Constant Current

Environmental. Electrical Specifications at 25 O C E Output Constant Current

TEP 100WIR Series, 100 Watt

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

20W DC-DC Converter P20J-Series

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

Safety Standards. Model Number: Unit Weight:

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

Safety Standards. Model Number:

Safety Standards. Model Number:

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS

Datasheet. ACF-10 Series AC/DC Power Module 10W

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

VP ELECTRONIQUE MASSY - Tel

060AAS19 B MDS. MDS Medical AC-DC Adapter 19Volt, 60Watt / MDS-060AAS19 B. Highlights & Features. Safety Standards. Model Number: General Description

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

DDR-120 series. 120W DIN Rail Type DC-DC Converter

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Safety Standards. Model Number:

AC/DC Converter SLD05-20Bxx Series

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Max. Output Power. Typical Efficiency (3) 0 ~ 25.0 A 300 W 91.5% 0.96 EBV-350S012SV 0 ~ 14.6 A 350 W 93.5% 0.96 EBV-350S024SV

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

EPT W 5V 2.4A ±5% EPT W 7V 1.71A ±5% EPT W 9V 1.5A ±5% EPT W 12V 1.25A ±5% EPT W 15V 1.0A ±5%

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

HEC-100RTN-48QSCA Rev A1.0

VEL05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

100BPS15 B. MDS Medical AC-DC Open Frame 15Volt, 100Watt / MDS-100BPS15 B ``` Highlights & Features. Safety Standards.

12W AC/DC interchangeable Adapter MU012-HA Series

Max. Output Power(2) Typical Efficiency (3) 0 ~ 18.4 A 220 W 91.5% 0.96 EBV-250S012SV 0 ~ 10.5 A 250 W 93.0% 0.96 EBV-250S024SV

Safety Standards. Model Number:

SAM Listed LED Optimized Drivers. Environmental. Electrical Specifications at 25 O C E Output Current. Voltage Accuracy

Safety Standards. Model Number:

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

ORDERING INFORMATION SEE PAGE 6

5W AC/DC interchangeable Adapter MU005-HA Series

Safety Standards. Model Number:

Output Current Input Current Max. capacitive Load

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

Safety Standards. Model Number:

TEP 75WI Series, 75 Watt

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

Safety Standards. Model Number:

Safety Standards. Model Number:

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 100V AC to 77% at 80V AC)

Safety Standards. Model Number:

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS24 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Switching Power Supplies

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

POWERBOX Industrial Line PMR20W Series 20W 4:1 Single and Dual Output High Performance DC/DC Converter

Transcription:

Features Regulated Converter Universal input VAC 3W PCB mount package <75mW No load power consumption Ultra low profile, compact size - C to +85 C operating temperature Continuous SCP, OCP, OVP EN335, IEC/EN/UL9 CE certified Description The series are low cost AC/DC power supplies, ideal for PCB mounted, compact, board level industrial applications. They feature universal AC input voltage range, regulated and short-circuit -proof isolated DC outputs, low standby power consumption and - C to +85 C operating temperature range. The have a built-in Class A / FCC Part 15 EMC filter, are certified to IEC/EN/UL9-1 and EN335 and are pending to IEC/EN/UL62368 and EN61558 safety standards and come with a three year warranty. 3 Watt Single Output EMC Class A Selection Guide Part Number RAC3-3.3SGA RAC3-5SGA RAC3-15SGA RAC3-24SGA Input Voltage Range [VAC] Output Voltage [VDC] 3.3 5 12 15 24 Output Current [ma] 9 2 1 Efficiency typ (1) [%] 72 78 78 Max. Capacitive Load (2) [µf] 1 On Request RAC3-9SGA 9 3 77 E196683 Note1: Efficiency is tested at and full load at +25 C ambient Note2: Max. Cap. Load is tested at nominal input and full resisitive load Model Numbering UL9-1 certified IEC/EN9-1 certified UL62368-1 certified IEC/EN62368-1 certified EN61558-1 certified EN61558-2-16 certified EN335-1 certified CB Report RAC3- SGA nom. Output Power EMC Class A Single nom. Output Voltage Ordering Examples: www.recom-power.com Single Output EMC Class A REV.: 4/19 PA-1

BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Input Voltage Range (3,4) Input Current Inrush Current cold start at 25 C No load Power Consumption nom. Vin = 2VDC 85VAC 1VDC Input Frequency Range AC Input 45Hz 65Hz Minimum Load % Power Factor Start-up Time, ms 1s Hold-up time Internal Operating Frequency % load at nominal Vin 65kHz Output Ripple and Noise (5) MHz BW C to 85 C - C to C 1 1 ma 45mA.53.41 5ms ms Note3: The products were submitted for safety files at AC-Input operation Note4: Refer to Line Derating Note5: Measurements are made with a 12 twisted pair-wire with a.1µf and µf parallel capacitor across output (low ESR) 5VAC 4VDC A A 75mW Pi-type mvp-p mvp-p 1mVp-p mvp-p 2mVp-p mvp-p mvp-p 2mVp-p mvp-p mvp-p Efficiency vs. Load RAC3-5SGA Efficiency [%] 115Vin 2Vin Efficiency [%] 115Vin 2Vin www.recom-power.com REV.: 4/19 PA-2

REGULATIONS Parameter Condition Value Output Accuracy PROTECTIONS Parameter Type Value Input Fuse (6) internal T1A, V Short Circuit Protection (SCP) below mw long-term mode, auto recovery Over Voltage Protection (OVP) Over Voltage Category Over Current Protection (OCP) Class of Equipment 1 1 3.8V - 4.9V 5.3V - 6.8V 12.6V - 16.2V 15.75V -.3V 25.2V - 32.4V 1.41A -3.A.91A - 2.2A.37A -.95A.29A -.72A.19A -.45A hiccup mode, auto recovery OVCII hiccup mode, auto recovery Isolation Voltage (7) I/P to O/P rated for 1 minute 3kVAC/mA Isolation Resistance Insulation Grade ±2.5% max. Line Regulation low line to high line ±.5% max. Load Regulation % to % load.5% max. Deviation vs. Load (at, ) RAC3-5SGA 2.5 2.5 Deviation [%] 2 1.5 1.5 -.5-1 -1.5-2 -2.5 Class II MΩ min. reinforced Leakage Current 277VAC, Hz.1mA max. Deviation [%] 2 1.5 1.5 -.5-1 -1.5-2 -2.5 Note6: Refer to local wiring regulations if input over-current protection is also required Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note8: For operation, an external MOV is recommended. The Varistor should comply with IEC651-2. eg. EPCOS S14 series L N Protection Circuit F VAC in (L) +V out +V out U VAC in (N) -V out -V out www.recom-power.com REV.: 4/19 PA-3

ENVIRONMENTAL Parameter Condition Value Operating Temperature Range @ natural convection.1m/s Maximum Case Temperature Temperature Coefficient Operating Altitude full load refer to derating graph - C to + C - C to +85 C + C.3%/K Operating Humidity non-condensing 5% - 95% RH Pollution Degree Shock Vibration MTBF according to MIL-HDBK-217F, G.B. +25 C + C m PD2 G/11ms pulse, 3 times at each x, y, z axes -1Hz, 2G min./1cycle, period min. along x,y,z axes for 6 cycles x 3 hours 17 x 3 hours Derating Graph (@ Chamber and natural convection.1m/s) Line Derating - - 85 1 Ambient Temperature [ C] 85 1 135 1 185 2 235 2 285 5 Input Voltage [VAC] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety Audio/video, information and communication technology equipment. Safety requirements E196683-A4-UL UL9-1, 2nd Edition, 14 CAN/CSA C22.2 No. 9-1-7, 2nd Edition, 14 UL62368-1, 2nd Edition CAN/CSA C22.2 No 62368-1-14 Information Technology Equipment, General Requirements for Safety EN9-1: 6 + A2:13 SA13184S 1 Information Technology Equipment, General Requirements for Safety (CB) IEC9-1:5, 2nd Edition + A2:13 Audio/video, information and communication technology equipment. Safety requirements 4787985921- Audio/video, information and communication technology equipment. Safety requirements (CB) 1725-CB EN62368-1: 14 IEC62368-1:14, 2nd Edition Household and similar electrical appliances Safety Part 1: General requirements EN335-1:12+A12:17 211-771- Household and similar electrical appliances Safety Part 1: General requirements (CB) IEC335-1:, 5th Edition + A1:13 Household and similar electrical appliances Safety Part 1: General requirements Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure SA13184L 1 EN335-1:12+A11:14 EN62233:8 continued on next page www.recom-power.com REV.: 4/19 PA-4

Certificate Type (Safety) Report / File Number Standard supply voltages up to 1 V supply voltages up to 1 V Part 2: Particular requirements supply voltages up to 1 V supply voltages up to 1 V Part 2: Particular requirements supply voltages up to 1 V (CB) supply voltages up to 1 V Part 2: Particular requirements (CB) SA 13184L 1 211-7- 211-7- EN61558-1: 5 + A1:9 EN61558-2-16: 9 + A1:13 EN61558-1: 5 + A1:9 EN61558-2-16: 9 + A1:13 IEC61558-1:5, 2nd Edition + A1:9 IEC61558-2-16:9, 1st Edition + A1:13 EAC RU-AT.3.67361 TP TC 4/, 11 RoHS 2+ RoHS 11/65/EU + AM15/863 EMC Compliance Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment Emission Requirements (9) Information technology equipment - Immunity characteristics - Limits and methods EA13184E 1 of measurement Limitations on the amount of electromagnetic interference allowed from digital and electronic devices EN532: 15, Class A EN524: + A1:15 EA13184F 1 47 CFR FCC Part 15 Subpart B: 16 ESD Electrostatic discharge immunity test Air ±8kV, Contact ±4kV EN-4-2: 9, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN-4-3: 6 + A2,, Criteria A Fast Transient and Burst Immunity AC Port ±1kV EN-4-4: 12, Criteria A Surge Immunity AC Port L-N ±1kV EN-4-5: 14, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port 3V EN-4-6: 14, Criteria A Voltage Dips and Interruption Voltage Dips >95% Voltage Dips % Interruptions >95% Note9: If output is connected to GND, please contact RECOM tech support for advice EMC Filtering according to EN514-1 / EN532 Class B Compliance EN-4-11: 4, Criteria A EN-4-11: 4, Criteria A EN-4-11: 4, Criteria C CY1 L CX1 +V OUT CY1, CY2 1nF, 2kV CX1 nf, 2kV N -V OUT CY2 DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material Dimension (LxWxH) Weight case PCB black plastic, (UL94 V-) FR4, (UL94 V-) 37. x 24. x 15.mm g typ. continued on next page www.recom-power.com REV.: 4/19 PA-5

Dimension Drawing (mm) 37. embossed logo. ±.1 36.7 3.26 5.8 x 2.54 = 25. 1 2 3 Bottom View 5 4 7 x 2.54 = 17.78 3.11 3.5 ±.5 15. 24. 23.5 Recommended Footprint Details Top View 5 4 1 2 3 2.54 2.54 restricted area for PCB layout Pin Connections Pin # Single 1 VAC in (L) 2 VAC in (N) 3 NC 4 -Vout 5 +Vout NC: Not Connected Tolerance: xx.x ±.5mm Pin Width: xx.xx ±.5mm 5.8 PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 5. x 39.7 x 23.2mm Packaging Quantity pcs Storage Temperature Range - C to + C Storage Humidity non-condensing 5% -95% RH max. The product information and specifications may be subject to changes even without prior written notice.the product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 4/19 PA-6