MC352-1P-1S Industrial PoE+ Media Converter User Manual

Similar documents
NS2052-8P-2C Industrial PoE+ Switch User Manual

NS2052-8P-2C Industrial PoE+ Switch User Manual

IFS MC201-1P/1FS User Manual

IFS MC350-1T-2S User Manual

Industrial 8-Port 10/100TX 802.3at PoE+ + 2-Port Gigabit TP/SFP Combo Ethernet Switch IFGS-1022HPT. User s Manual

MC100FX-TX-PoE Media Converter User Manual

100Base-FX to 10/100Base-TX. PoE. Media Converter. FCU-1802Px. User s Manual

IFS MC352-4P-2S User Manual

1000Base-SX / LX to 10/100/1000Base-T 802.3at PoE Industrial Media Converter

TruVision IP Thermal Camera Installation Guide

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

IFS MC-4TX Series Industrial Ethernet Switch User Manual

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

100/1000BASE-X to 10/100/1000BASE-T at PoE Media Converter. GTP-805A User s Manual

5/8-Port 10/100/1000Mbps. Industrial Gigabit Ethernet Switch IGS-501 / IGS-801 / IGS-501T / IGS-801T. User's Manual

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

5-Port 10/100Mbps with 4-Port PoE. Industrial Fast Ethernet Switch ISW-504PT / ISW-514PT / ISW-514PT15 / ISW-514PTF. User's Manual

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

ES3002-4P-4T User Manual

Copyright PLANET Technology Corp Contents subject to revision without prior notice.

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

IFS NS3550-8T-2S Quick Installation Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

10/100/1000Mbps. Gigabit Ethernet Switch GSW-2401/GSW User's Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

1000Base-SX / LX to 10/100/1000Base-T at PoE. Industrial Media Converter IGTP-802T / IGTP-802TS / IGTP-805AT. User s Manual

Industrial 8-Port 10/100/1000T + 2-Port 100/1000X SFP Ethernet Switch (-40~75 degrees C)

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

24-Port 10/100Mbps + 2-Port. Gigabit Ethernet Switch FGSW User s Manual

Industrial 5-/8-Port 10/100TX Compact Ethernet Switch. ISW-500T/ISW-800T User s Manual

Industrial 1-Port Coax/UTP Long Reach PoE+ 4-Port. 10/100TX PoE Extender LRP-104CET. User s Manual

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

Industrial 10G/5G/2.5G/1G/100M Copper to. 10GBASE-X SFP+ Media Converter IXT-705AT. User s Manual

IFS NS3552-8P-2S and NS3550-2T-8S Quick Installation Guide

Industrial 4-Port 10/100/1000Base-T. + 2-Slot 100/1000Base-X SFP Ethernet Switch IGS-620TF. User's Manual

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

IFS MC250-4T/1CXT User Manual

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

TruVision IP PTZ Camera Installation Guide

Industrial 10G/5G/2.5G/1G/100M Copper to 10GBASE-X SFP+ Media Converter

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

Perle Gigabit Media Converter Module. Installation Guide P/N

Industrial IP67 Rated 8-Port 10/100Mbps M12 Fast Ethernet PoE Switch with Wide Operating Temperature

IGTP-802T/IGTP-802TS/IGTP-805AT

Industrial Single-Port 10/100/1000Mbps bt PoE Injector. IPOE-171 Series User s Manual

LNX-0702G-SFP Series

TruVision HD-TVI 720P and 1080P Bullet Camera Installation Guide

LNX-1002C-SFP Series

Long Reach. PoE over Coaxial / UTP. Extender Kit. LRP-101C-KIT and LRP-101U-KIT. User s Manual

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

Industrial 8-Port 10/100TX 802.3at PoE + 2-Port Gigabit TP/SFP Combo Ethernet Switch (-40~75 degrees C)

10G/5G/2.5G/1G/100M Copper to 10GBASE-X SFP+ Media Converter. XT-705A User s Manual

Industrial Gigabit Switch. With 4 Port 802.3at PoE+ IGS-504HPT / IGS-624HPT. User's Manual

Industrial Ultra Power over Ethernet Splitter IPOE-171S

Industrial 4-Port 10/100/1000T 802.3at PoE+ w/ 2-Port 100/1000X SFP Ethernet Switch

4-Port 10/100Mbps +1/2 100FX Fiber Port. Industrial Fast Ethernet Switch. ISW-511 / ISW-621 Series. ISW-511T / ISW-621T Series.

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

SP-PoE Splitter User Manual

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Korenix JetNet 3000 Series Industrial Entry-Level Ethernet Rail Switch User s Manual

KFC-200. Installation Guide

IFS NS P/4S GE-DSSG-244 GE-DSSG-244-POE Quick Installation Guide

Industrial 3-Port Fast Ethernet Media Converter Switches

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

Industrial Single-Port 10/100/1000Mbps 802.3bt PoE Injector (95 Watts, -40~75 degrees C, 12~48V DC)

Lantech I(P)GS-0008B. 8 10/100/1000T (PoE at/af) Industrial Unmanaged Ethernet Switch I(P)ES-0008B

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

4-Port 10/100Mbps +1/2 100FX Fiber Port. Industrial Fast Ethernet Switch. ISW-511 / ISW-621 Series. ISW-511T / ISW-621T Series.

PoE Injector Hutschiene PoE-H

Fast / Gigabit Ethernet Switch Module. MII series. User's Manual

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

8-Port 10/100TX 802.3at PoE + 1-Port 10/100/1000T + 1-Port 100/1000X SFP Desktop Switch FGSD-1011HP. User s Manual

Industrial 1-Port 10/100/1000T Ultra PoE + 1-Port Coax/UTP Long Reach PoE Kit (LRP-201ET + LRP-201HT)

EDS-G205A-4PoE Hardware Installation Guide

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

IFS MCR-R15 Media Converter Rack User Manual

TruVision IP PTZ Camera FW5.1 Installation Guide

Industrial Single-Port 10/100/1000Mbps 802.3bt PoE Injector (60 Watts, -40~75 degrees C, 48~56V DC)

TruVision IP PTZ Camera FW5.1 Installation Guide

IMC-21GA Quick Installation Guide

8-port 10/100Base-TX Switch (INS-806) User s Guide

TruVision High Definition TVI Bullet Camera Installation Guide

TruVision Series 5 IP Camera Installation Guide

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

M727xSP. PoE Powered. Ethernet Media Converter 10/100BASE-TX TO 100BASE-SX/LX. Installation Guide

8-Port 10/100TX 802.3at PoE + 2-Port 10/100TX Desktop Switch FSD-1008HP. User s Manual

Quick Start Guide. Physical Description. The Port Status LEDs

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

IFS MC251-4P/1CXT User Manual

AT IEEE 802.3af Universal Multi-voltage PoE Splitter. Installation and User Guide. PN Rev A

Perle 10/100 Ethernet Media Converter Module. Installation Guide. P/N (Rev C)

Transcription:

MC352-1P-1S Industrial PoE+ Media Converter User Manual P/N 1072579-EN REV B ISS 02OCT18

Copyright Disclaimer Trademarks and patents Manufacturer Version FCC compliance FCC compliance Canada ACMA compliance Certification 2018 United Technologies Corporation. All trademarks are the property of their respective owners. Interlogix is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. All rights reserved. Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of UTC Fire & Security Americas Corporation, Inc. Trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products. Interlogix 2955 Red Hill Avenue, Costa Mesa, CA 92626-5923, USA Authorized EU manufacturing representative: UTC Fire & Security B.V. Kelvinstraat 7, 6003 DH Weert, The Netherlands This document applies to MC352-1P-1S. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Class A: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This Class A digital apparatus complies with CAN ICES-003 (A)/NMB-3 (A). Cet appareil numérique de la classe A est conforme à la norme CAN ICES- 003 (A)/NMB-3 (A). Notice! This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. EU directives This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU. 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info.

Product warnings and disclaimers THESE PRODUCTS ARE INTENDED FOR SALE TO AND INSTALLATION BY QUALIFIED PROFESSIONALS. UTC FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY AUTHORIZED DEALER OR AUTHORIZED RESELLER, IS PROPERLY TRAINED OR EXPERIENCED TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS. For more information on warranty disclaimers and product safety information, please check www.firesecurityproducts.com/policy/productwarning/ or scan the following code: Contact information and manuals/ tools/ firmware For contact information and to download the latest manuals, tools, and firmware, go to the web site of your region. Americas: www.interlogix.com EMEA: www.firesecurityproducts.com Manuals are available in several languages Australia/New Zealand: www.utcfs.com.au

Content Important information 2 Chapter 1 Introduction 3 Package contents 3 Product description 3 Chapter 2 Hardware introduction 5 Physical dimensions 5 Front panel 6 Top panel 7 Product features 9 Product specifications 10 Chapter 3 Installation 12 DIN-rail mounting 12 Wall mount plate mounting 14 Installing the SFP transceiver 14 802.3at/802.3af installation 15 Link Fault Pass through (LFP) 16 Chapter 4 Troubleshooting 19 Appendix A Networking connection 20 Appendix B Approved Interlogix SFP transceivers 23 MC352-1P-1S Industrial PoE+ Media Converter User Manual 1

Important information Limitation of liability To the maximum extent permitted by applicable law, in no event will UTCFS be liable for any lost profits or business opportunities, loss of use, business interruption, loss of data, or any other indirect, special, incidental, or consequential damages under any theory of liability, whether based in contract, tort, negligence, product liability, or otherwise. Because some jurisdictions do not allow the exclusion or limitation of liability for consequential or incidental damages the preceding limitation may not apply to you. In any event the total liability of UTCFS shall not exceed the purchase price of the product. The foregoing limitation will apply to the maximum extent permitted by applicable law, regardless of whether UTCFS has been advised of the possibility of such damages and regardless of whether any remedy fails of its essential purpose. Installation in accordance with this manual, applicable codes, and the instructions of the authority having jurisdiction is mandatory. While every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents, UTCFS assumes no responsibility for errors or omissions. Advisory messages Advisory messages alert you to conditions or practices that can cause unwanted results. The advisory messages used in this document are shown and described below. WARNING: Warning messages advise you of hazards that could result in injury or loss of life. They tell you which actions to take or to avoid in order to prevent the injury or loss of life. Caution: Caution messages advise you of possible equipment damage. They tell you which actions to take or to avoid in order to prevent damage. Note: Note messages advise you of the possible loss of time or effort. They describe how to avoid the loss. Notes are also used to point out important information that you should read. 2 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Chapter 1 Introduction The description of the IFS MC352-1P-1S model is as follows: 1000BASE-SX/LX to 10/100/1000BASE-T 802.3at PoE Industrial Media Converter Unless specified, the term industrial media converter mentioned in this user manual refers to the MC352-1P-1S. Package contents Check the contents of your package for the following parts: The industrial media converter 1 DIN rail kit 1 Wall mounting kit 1 RJ45 dust cap 1 SFP dust cap 1 If any of these are missing or damaged, contact your dealer immediately. If possible, retain the carton including the original packing materials for repacking the product in case there is a need to return it to us for repair. Product description The MC352-1P-1S Gigabit Media Converter combines Ethernet media conversion (from 1000BASE-X to 10/100/1000BASE-T) with 802.3at Power over Ethernet Plus (PoE+) injector to deliver both up to 30 W of power output and high data transmission speed to PDs (powered devices) installed in a remote area where sufficient and reliable power input is required. Its 1000BASE-X fiber optic uplink port provides long distance, high speed, and stable data transmission to a remote core network. The special and convenient power system of the industrial media converter supports 24~48 VDC power input for power redundancy and operational flexibility. MC352-1P-1S Industrial PoE+ Media Converter User Manual 3

Chapter 1: Introduction Being able to operate under the temperature range of -40 to 75 C and with an IP30 rugged case, the industrial media converter can be placed in almost any difficult environment. Fiber-optic link capability extends the range of network deployment The maximum distance between a PoE PSE (power sourcing equipment) and PD via Ethernet cable is 100 meters. To extend the PoE deployment range, the industrial media converter is integrated with fiber interface for further distance applications. The industrial media converter s fiber connector type is an SFP slot supporting 1000BASE- X multi/single mode SFP modules and a transmission distance up to 120 km (depending on the SFP module). With the long fiber distance support, the industrial media converter still sustains the transmission performance as high as 1000 Mbps. It works in the high-performance Store and Forward mechanism, and also can prevent packet loss with IEEE 802.3x flow control and the LFP (Link Fault Pass-through) function in the DIP switch design. Furthermore, it can immediately alarm the administrators the issue from the link media and provide efficient solution to monitor the network power usage. Plug and play high power sourcing solution Complying with the IEEE 802.3at Power over Ethernet Plus technology, the industrial media converter provides up to 30 W of PoE output power, doubling that of the earlier 802.3af. It is also backward compatible with 802.3af PoE standards to allow users to flexibly deploy standard and high powered devices simultaneously with no software configuration. With data and Power over Ethernet from one unit, the industrial media converter can reduce cable deployment and eliminate the need for dedicated electrical outlets on the wall, ceiling, or any unreachable place. Convenient and reliable power system To facilitate the 802.3at power PoE+ usage with the commonly-used 24~48 VDC power input for transportation and industrial-level applications, the industrial media converter adopts the 24~48 VDC to 52 V power boost technology to solve power source issues but does not require special power supplies. Its wide-ranging voltages design is suitable for worldwide operability with high availability applications requiring dual or backup power inputs. Environmentally hardened design for industrial PoE networks The industrial media converter is specifically designed with durable components and a strong housing case to operate reliably in electrically harsh and climatically demanding environments like plant floors or curbside traffic control cabinets. The industrial media converter is packaged in a compact, IP30 rugged case that permits either DIN-rail or wall mounting for efficient use of cabinet space. With IP30 rugged case protection and PoE design, the industrial media converter is ideal for service providers, campuses, and public areas to cost-effectively deploy PoE wireless access points, IP cameras, or IP phones easily and efficiently. It can also operate in a wide temperature range of -40 to 75 C, so it can be placed in almost any location. 4 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Chapter 2 Hardware introduction Physical dimensions Dimensions (W x D x H): 135 x 87 x 32 mm MC352-1P-1S Industrial PoE+ Media Converter User Manual 5

Chapter 2: Hardware introduction Front panel The front panel of the industrial media converter consists of one 1000Base-SX / 1000Base-LX / mini-gbic SFP port and one Auto-Sensing 10/100/1000Mbps Ethernet RJ-45 Port. LED indicators The front panel LEDs indicate port link status, data activity, and system power. System LED Color Function P1 Green Lit: indicates that the power input 1 has power. P2 Green Lit: indicates that the power input 2 has power. Fault Green Lit: indicates that either power 1 or power 2 has no power. Gigabit fiber interface LED Color Function 6 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Chapter 2: Hardware introduction Fiber LNK/ACT Green Lit: indicates that the fiber optical port has successfully connected to the network at 1000 Mbps. Blinking: indicates that the fiber optical is actively sending or receiving data over that port. Gigabit TP interface LED Color Function TP LNK/ACT Green Lit: indicates the port has successfully connected to the network at 10/100/1000 Mbps. Blinking: indicates that the port is actively sending or receiving data. TP 1000 Green Lit: indicates the port has successfully connected to the network at 1000 Mbps. PoE Off: indicates that the port has successfully connected to the network at 10/100 Mbps. LED Color Function PoE In-use Orange Lit: indicates that the port is providing 52 VDC to a remote powered device. Off: indicates that the port is not providing 52 VDC to a remote powered device). Top panel The top panel of the industrial media converter consists of one terminal block connector within two DC power inputs. Wiring the power inputs The 6-contact terminal block connector on the top panel of the industrial media converter is used for two DC redundant power inputs. Follow the steps below to insert the power wire. MC352-1P-1S Industrial PoE+ Media Converter User Manual 7

Chapter 2: Hardware introduction Caution: When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make sure the power is OFF to prevent from getting an electric shock. 1. Insert positive/negative DC power wires into contacts 1 and 2 for Power 1, or 5 and 6 for Power 2. 2. Tighten the wire-clamp screws to prevent the wires from loosening. 1 2 3 4 5 6 Power 1 Fault Power 2 - + - + Wiring the fault alarm contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the wires, the industrial media converter detects the fault status of the power failure and then forms an open circuit. The following illustration shows an application example for wiring the fault alarm contacts. Wires are inserted into the fault alarm contacts. Note: 8 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Chapter 2: Hardware introduction 1. The wire gauge for the terminal block should be in the range of 12 to 24 AWG. 2. Alarm relay circuits accept up to 30 V, max. 3 A currents. Product features Physical port 1-port 10/100/1000BASE-T RJ45 with IEEE 802.3af /802.3at PoE Injector. 1 SFP slot, supporting 1000BASE-X transceiver dual mode. Power over Ethernet Complies with IEEE 802.3at Power over Ethernet Plus, end-span PSE. One IEEE 802.3af/IEEE 802.3at device powered. Supports PoE power up to 30.8 W for each PoE port. Provides DC 52 V power over RJ45 Ethernet cable to PD with Ethernet port. Auto-detects IEEE 802.3at/af equipment and protects devices from being damaged by incorrect installation. Remote power feeding up to 100 m. IEEE 802.3at/af splitter devices compatible. Layer 2 Features Supports auto-negotiation and 10/100Mbps half / full duplex and 1000Mbps full duplex mode on RJ45 port Prevents packet loss with back pressure (half-duplex) and IEEE 802.3x pause frame flow control (full-duplex) Hardware LED Indicators System: Power 1, Power 2 and Fault LED Fiber port: LNK/ACT 10/100/1000BASE-T port: LNK/ACT, 1000, PoE-in-use DIP switch: LFP (Link Fault Pass-through) mode selection Industrial case and installation IP30 aluminum case DIN-rail and wall-mount design 24 to 48 VDC redundant power with polarity reverse protect function and connective removable terminal block for master and slave power. Supports Ethernet ESD protection for 6000 VDC MC352-1P-1S Industrial PoE+ Media Converter User Manual 9

Chapter 2: Hardware introduction -40 to 75 C operating temperature Product specifications Ethernet Interface Copper Fiber-optic Connector Type Fiber Cable 10/100/1000BASE-T Ethernet TP interface Auto-negotiation, auto MDI/MDI-X with PoE injector function SFP (LC) Dependent on SFP Module Hardware Specifications Speed Flow Control Maximum Frame Size Link Fault Pass-through DIP Switch Enclosure Installation Cables Alarm LED Twisted-pair: 10/20Mbps for half/full duplex, 100/200Mbps for half/full duplex 1000/2000Mbps for full duplex Fiber Optic: 2000Mbps for full duplex IEEE 802.3x pause frame for full-duplex Back pressure for half-duplex 9K bytes ON/OFF IP30 metal case DIN rail kit and wall-mount kit 10/100/1000BASE-T: 2-pair UTP Cat. 3, 4, 5, 5e, 6 (maximum 100 meters) EIA / TIA-568 100-ohm STP (maximum 100 meters) 1000BASE-SX /LX: Multi-mode: 50/245μm or 62.5/125μm optical fiber Single-mode: 9/125μm optical fiber One relay output for power failure. Alarm relay current carry ability: 1A @ 24 VDC System: Power 1 (Green) Power 2 (Green) Power fault Alarm (Green) PoE: PoE-in-Use (Orange) 10/100/1000BaseT: LNK/ACT (Green) 1000 (Green) 10 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Chapter 2: Hardware introduction Fiber 1000BASE-X: LNK/ACT (Green) Unit Input Voltage Power Consumption ESD Protection Dimensions (W x D x H) Weight 24 ~ 48 VDC 35 W /120.85 BTU 6K VDC 135 x 87 x 32 mm 500 g Power over Ethernet PoE Standard PoE Power Supply Type PoE Power Output IEEE 802.3af Power over Ethernet IEEE 802.3at Power over Ethernet Plus End-span IEEE 802.3af Standard Per port 48~51 VDC (depending on the power supply), max. 15.4 W. IEEE 802.3at Standard Per port 51~56 VDC (depending on the power supply), max. 30 W. Power Pin Assignment 1/2(+), 3/6(-) PoE Power Budget 35 W Standards Conformance Regulation Compliance Standards Compliance FCC Part 15 Class A, CE IEEE 802.3 Ethernet IEEE 802.3u Fast Ethernet IEEE 802.3ab Gigabit Ethernet IEEE 802.3z Gigabit Ethernet over Fiber Optic IEEE 802.3x Flow Control IEEE 802.3af Power over Ethernet IEEE 802.3at Power over Ethernet Plus Environment Operating Storage Temperature: -40 to 75 C Relative Humidity: 5 to 90% (non-condensing) Temperature: -40 to 85 C Relative Humidity: 5 to 90% (non-condensing) MC352-1P-1S Industrial PoE+ Media Converter User Manual 11

Chapter 3 Installation This section describes how to install and make connections to the industrial media converter. Read the following topics and perform the procedures in the order presented. Note: The images in the following installation instructions are provided for reference. The device shown is not the industrial media converter. DIN-rail mounting There are two methods to install the industrial industrial media converter: DIN-rail mounting and wall-mount plate mounting. Please read the following topics and perform the procedures in the order presented. Note: Follow all the DIN-rail installation steps as shown in the example. To install the DIN rails on the industrial media converter: 1. Screw the DIN-rail onto the industrial media converter. 2. Carefully slide the DIN-rail into the track. 12 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Chapter 3: Installation 3. Ensure that the DIN-rail is tightly attached to the track. To remove the industrial media converter from the track: Carefully remove the DIN-rail from the track. MC352-1P-1S Industrial PoE+ Media Converter User Manual 13

Chapter 3: Installation Wall mount plate mounting Note: Follow all the wall mount plate installation steps as shown in the example. To install the industrial media converter on the wall: 1. Remove the DIN-rail from the industrial media converter. Use a screwdriver to loosen the screws to remove the DIN-rail. 2. Place the wall-mount plate on the rear panel of the industrial media converter. 3. Use the screwdriver to screw the wall mount plate onto the industrial media converter. 4. Use the hook holes at the corners of the wall mount plate to hang the industrial media converter on the wall. 5. To remove the wall mount plate, reverse the steps above. Installing the SFP transceiver SFP transceivers are hot-pluggable and hot-swappable. They can be plugged in and removed to/from any SFP port without having to power down the industrial media converter (see below). 14 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Chapter 3: Installation Before connecting to other network devices: 1. Make sure both sides of the SFP transceiver are with the same media type. For example, 1000BASE-SX to 1000BASE-SX, 1000BASE-LX to 1000BASE-LX. 2. Check if the fiber-optic cable type matches the SFP transceiver requirement. To connect to 1000BASE-SX SFP transceiver, use the multi-mode fiber cable with one side being male duplex LC connector type. To connect to 1000BASE-LX SFP transceiver, use the single-mode fiber cable with one side being male duplex LC connector type. To connect the fiber cable: 1. Attach the duplex LC connector on the network cable to the SFP transceiver. 2. Connect the other end of the cable to a device with the SFP transceiver installed. 3. Check the LNK/ACT LED of the SFP slot on the front of the industrial media converter. Ensure that the SFP transceiver is operating correctly. 4. Check the link mode of the SFP port if the link fails. Note: We recommend the use of Interlogix SFPs on the industrial media converter. If you insert an SFP transceiver that is not supported, the industrial media converter will not recognize it. To remove the transceiver module: 1. Make sure there is no network activity by checking with the network administrator. Or, through the management interface of the switch/converter (if available), disable the port in advance. 2. Carefully remove the fiber optic cable. 3. Turn the lever of the transceiver module to a horizontal position. 4. Pull out the module gently through the lever. Note: Never pull out the module without making use of the lever or the push bolts on the module. Removing the module with force could damage the module and the SFP module slot of the industrial media converter. 802.3at/802.3af installation Before installation, we recommend checking your network environment. The industrial media converter requires 48 VDC or 24 VDC input and it injects the DC power into the pin of the twisted pair cable (Pin 1, 2, 3 and 6). MC352-1P-1S Industrial PoE+ Media Converter User Manual 15

Chapter 3: Installation Link Fault Pass through (LFP) The LFP refers to the Link Fault Pass Through function (LLCF/LLR) and the DIP Switch settings. LLCF/LLR can immediately notify administrators about a problem with the link media. The DIP Switch enables or disables the LFP function. LLCF (Link Loss Carry Forward) detects the connection loss on the TP line, and LLR (Link Loss Return) detects the connection loss on the fiber line. Link Loss Carry Forward (LLCF) The industrial media converter incorporates an LLCF function for troubleshooting a remote connection. When the LFP function is enabled, the FL/TP ports do not transmit a link signal until they receive a link signal from the opposite port. The diagram below shows a typical network configuration with a good link status using industrial media converter for remote connectivity. In case of a connectivity issue, the industrial media converter LLCF sends the notification to the switch/hub that generates a trap to the management station. 16 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Chapter 3: Installation * The factory default setting for the LFP function is "off". Link Loss Return (LLR) The fiber ports of the industrial media converter have been designed with an LLR function for troubleshooting a remote connection. LLR works in conjunction with LLCF. When the LFP function is enabled, the port s transmitter shuts down when its receiver fails to detect a valid connection. LLR should only be enabled on one end of the link and is typically enabled on either the unmanaged or remote device. The diagram below shows a typical network configuration with a good link status using industrial media converter for remote connectivity. Note that LLR and LLCF are enabled as indicated in the diagram. If one of the optical conductors is bad (as shown in the diagram box below), the converter with LLR function will return a no-link condition to its link partner. With LLCF function also enabled, the no-link condition is carried forward to the switch/hub where a trap is generated to the management station. Note: The factory default setting for the LFP function is "off". This feature can also be turned on via the side DIP-switch. If the installer is familiar with the network installation and diagnostics (i.e. checking which end is broken in a connection), you can turn the MC352-1P-1S Industrial PoE+ Media Converter User Manual 17

Chapter 3: Installation switch to the on position and reset the converter for changes to take effect. Otherwise, we recommend keeping the DIP switch in its default position. 18 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Chapter 4 Troubleshooting This chapter contains information to help you solve issues. If the industrial media converter is not functioning properly, ensure that it was set up according to the instructions in this manual. Issue The link LED does not illuminate The industrial media converter doesn't connect to the network The port link LED illuminates, but the traffic is irregular The industrial media converter doesn t connect to the network. The industrial media converter does not power up. Solution Check the cable connection. 1. Check the LNK/ACT LED on the industrial media converter. 2. Try another port on the industrial media converter. 3. Make sure the cable is installed properly. 4. Make sure the cable is the right type. 5. Turn off the power. After a while, turn on power again. Check that the attached device is not set to dedicated full duplex. Some devices use a physical or software switch to change duplex modes. Auto-negotiation may not recognize this type of full-duplex setting. Check each port LED on the industrial media converter. Try another port. Make sure the cable is installed properly and the right type. Turn off the power. After a while, turn on the power again. 1. Check to ensure that the AC power cord is not faulty and that it is inserted properly. 2. If the cord is inserted correctly, replace the power cord. 3. Check that the AC power source is working by connecting a different device in place of the switch. 4. If that device does not work, check the AC power MC352-1P-1S Industrial PoE+ Media Converter User Manual 19

Appendix A Networking connection PoE RJ45 port pin assignments Pin Number 1 Power + 2 Power + 3 Power - 6 Power - RJ45 Power Assignment RJ45 port pin assignments 1000Mbps, 1000BASE-T Pin number MDI MDI-X 1 BI_DA+ BI_DB+ 2 BI_DA- BI_DB- 3 BI_DB+ BI_DA+ 4 BI_DC+ BI_DD+ 5 BI_DC- BI_DD- 6 BI_DB- BI_DA- 7 BI_DD+ BI_DC+ 8 BI_DD- BI_DC- Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly forbidden, is beyond the scope of this standard. 10/100Mbps, 10/100BASE-TX When connecting the industrial media converter to another Fast Ethernet switch, a bridge, or a hub, a straight or crossover cable is necessary. Each port of the industrial media converter supports auto-mdi (Media Dependent Interface)/MDI-X (Media Dependent Interface Cross) detection. This makes it possible to directly connect the industrial media converter to any Ethernet device without making a crossover cable. The following table and diagram show the standard RJ45 receptacle/ connector and their pin assignments. 20 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Appendix A: Networking connection Pin number MDI MDI-X 1 Tx + (transmit) Rx + (receive) 2 Tx - (transmit) Rx - (receive) 3 Rx + (receive) Tx + (transmit) 4, 5 Not used 6 Rx + (receive) Tx + (transmit) 7, 8 Not used The standard RJ45 receptacle/connector: There are eight wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and the color of the straight cable and crossover cable connection: Straight Cable SIDE 1 SIDE 2 1 2 3 4 5 6 7 8 SIDE 1 1 = White / Orange 1 = White / Orange 2 = Orange 2 = Orange 3 = White / Green 3 = White / Green 4 = Blue 4 = Blue 5 = White / Blue 5 = White / Blue 6 = Green 6 = Green 1 2 3 4 5 6 7 8 SIDE 2 7 = White / Brown 8 = Brown 7 = White / Brown 8 = Brown Crossover Cable SIDE 1 SIDE 2 1 2 3 4 5 6 7 8 SIDE 1 1 = White / Orange 1 = White / Green 2 = Orange 2 = Green 3 = White / Green 3 = White / Orange 4 = Blue 4 = Blue 5 = White / Blue 5 = White / Blue 6 = Green 6 = Orange 1 2 3 4 5 6 7 8 SIDE 2 7 = White / Brown 8 = Brown 7 = White / Brown 8 = Brown Ensure that connected cables are with the same pin assignment and color as the above diagram before deploying the cables into the network. MC352-1P-1S Industrial PoE+ Media Converter User Manual 21

Appendix A: Networking connection Fiber Optic cable connection parameters The wiring details are shown below: Standard Fiber Type Cable Specifications 1000BASE-SX (850 nm) Multi-mode 50/125 μm or 62.5/125 μm 1000BASE-LX (1300 nm) Multi-mode 50/125 μm or 62.5/125 μm Single-mode 9/125 μm Wiring distances Standard Fiber Diameter (micron) Modal Bandwidth (MHz* km) Max. Distance (meters) 1000BASE-SX MM 62.5 62.5 50 50 1000BASE-LX MM 62.5 50 50 100 200 400 500 5 4 5 220 275 500 550 550 SM 9 N/A 5000* Note: The single mode port (1000Base-LX port) of the industrial media converter is compliant with LX 5 kilometers and provides additional margin allowing for a 10/30/70 kilometer Gigabit Ethernet links on single mode fiber. 22 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Appendix B Approved Interlogix SFP transceivers The following list of approved Interlogix SFP transceivers is valid as of the time of publication: Part # Fiber Connector # of Fibers Fiber Type Max Distance Wave Length Optical Budget (dbm) Optical Power (dbm) Receiver Sensitivity (dbm) Operating Temperature Twisted Pair SFP 1000Base TX S30-RJ RJ 45 1 Cat5e Gigabit Ethernet 1000Base SX 100M (328 ft.) 0 to +50 C (32 to 122 F) S30-2MLC LC 2 Multimode 220/550 m (720 / 1800 ft.) 850 nm 7.5-9.5 ~ -1-17 0 to +50 C (32 to 122 F S35-2MLC LC 2 Multimode 220/550 m (720 / 1800 ft.) 850 nm 7.5-14 ~ -8-17 -40 to +75 C (-40 to 167 F) OM1 Multimode fiber @ 200/500 MHz-km OM2 Multimode fiber @ 500.500 MHZ-km Laser Rated for GbE LANs S30-2MLC-2 LC 2 Multimode 2 km (1.2 mi.) 1310 nm 10-9 ~ -1-19 0 to +50 C (32 to 122 F) OM3 Multimode fiber @ 2000/500MHz-km Optimized got 850 nm VCSELs Gigabit Ethernet 1000 Base LX S30-2SLC- 10 LC 2 Single Mode 10 km (6.2 mi.) 1310 nm 18-9.5 ~ -3-20 0 to +50 C (32 to 122 F) S35-2SLC- 10 LC 2 Single Mode 10 km (6.2 mi.) 1310 nm 18-9.5 ~ -3-20 -40 to +75 C (-40 to 167 F) S30-2SLC- 30 LC 2 Single Mode 30 km (18.6 mi.) 1310 nm 18-2 ~ +3-23 0 to +50 C (32 to 122 F) S35-2SLC- 30 LC 2 Single Mode 30 km (18.6 mi.) 1310 nm 18-2 ~ +3-23 -40 to +75 C (-40 to 167 F) Gigabit Ethernet 1000 Base ZX 23 MC352-1P-1S Industrial PoE+ Media Converter User Manual

Part # Fiber Connector # of Fibers Fiber Type Max Distance Wave Length Optical Budget (dbm) Optical Power (dbm) Receiver Sensitivity (dbm) Operating Temperature S30-2SLC- 70 LC 2 Single Mode 70 km (43 mi.) 1550 nm 19* -15 ~ -8-34 0 to +50 C (32 to 122 F) S35-2SLC- 70 LC 2 Single Mode 70 km (43 mi.) 1550 nm 19* -15 ~ -8-34 -40 to +75 C (-40 to 167 F) Gigabit Ethernet 1000 Base BX S30-1SLC/A- 10 LC 1 Single Mode 10 km (6.2 mi.) 1310 / 1490 nm 11-9 ~ -3-20 0 to +50 C (32 to 122 F) S30-1SLC/B- 10 LC 1 Single Mode 10 km (6.2 mi.) 1490 / 1310 nm 11-9 ~ -3-20 0 to +50 C (32 to 122 F) S30-1SLC/A- 20 LC 1 Single Mode 20 km (12 mi.) 1310 / 1490 nm 15-8 ~ -2-23 0 to +50 C (32 to 122 F) S30-1SLC/B- 20 LC 1 Single Mode 20 km (12 mi.) 1490 / 1310 nm 15-8 ~ -2-23 0 to +50 C (32 to 122 F) Gigabit Ethernet 1000 Base BX S30-1SLC/A- 60 LC 1 Single Mode 60 km (37 mi.) 1310 / 1490 nm 24 0 ~ +5-24 0 to +50 C (32 to 122 F) S30-1SLC/B- 60 LC 1 Single Mode 60 km (37 mi.) 1490 / 1310 nm 24 0 ~ +5-24 0 to +50 C (32 to 122 F) * Note: High Power Optic. There must be a minimum of 5 db of optical loss to the fiber for proper operation. Note: We recommend the use of Interlogix SFPs on the industrial media converter. If you insert an SFP transceiver that is not supported, the industrial media converter will not recognize it. Note: Choose a SFP transceiver that can be operated under -40 to 75 C temperature if the industrial media converter is working in a 0 to 50 C temperature environment. 24 MC352-1P-1S Industrial PoE+ Media Converter User Manual