Checklist for building an edge data center

Similar documents
Your network s path to its fiber future. Grow confidently with fiber solutions from an experienced partner

Uniprise Structured Cabling Solutions Guide

SYSTIMAX structured cabling systems. High-performance infrastructure built on the science of innovation

CommScope harnesses the power of PoE in Madrid

High Speed Migration: Choosing the right multimode multi-fiber push on (MPO) system for your data center

Introducing the NG4access ODF Platform

TENIO. Fiber Closures

The SYSTIMAX GigaSPEED X10D solution. The infrastructure modern enterprises and data centers depend on

See operational efficiency in a whole new light The Redwood intelligent lighting network solution from CommScope. Intelligent Building Solutions

How CORD will impact your central office

Fiber backbone cabling in buildings

Implementation considerations for cabling supporting remote powering

Introduction. Service and Support

FiberGuide Optical Raceway Solutions. Comprehensive, long-term management for your growing fiber network

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

Powered Fiber Cable System. Providing power and communication to remote devices

RFP Questions Guideline For Data Center Buyers

Fiber Backbone Cabling in Buildings

Universal connectivity grid design guide

SDN and NFV gaining traction: is your infrastructure ready?

Optimizing PON architectures maximizes electronics efficiencies. White paper

Modular plugs, accessories and tooling

Reducing Data Center Cooling Costs through Airflow Containment

DATA CENTRE & COLOCATION

The virtualized and converged central office/cable headend

Product Brochure Eaton 93PR UPS kw

White paper. Interleaved MIMO: Near-full MIMO performance, nearly half the costs

Data Centre & Colocation in Birmingham. Flexible. Secure. Accredited.

White Paper: Testing Strategies for SYSTIMAX High Speed Migration Solutions

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

Smart building connectivity

COLOCATION 1/4 RACK RACK COLD AISLE CONTAINEMENT PRIVATE CAGE PRIVATE SUITE FLEXIBLE PRICING OPTIONS

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

DATA CENTER SERVICES CONNECTIVITY: THE TRUE DIGITAL TRANSFORMATION

Green IT and Green DC

Create a sustainable, high-performance university campus.

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Cannon T4 Modular Data Center (MDC)

Fiber to the home solutions. To migrate to FTTH with agility and ease, count on CommScope. Europe, Middle East and Africa reference guide

Powered fiber cable system technical overview: Hybrid optical fiber system for extending Power over Ethernet (PoE)

The changing route to the last mile

SYSTIMAX EHD ULL fiber panels solution guide. Enhanced high-density fiber solutions for ultra low-loss applications

Discover the Hidden Cost Savings of Cloud Computing

DATA CENTER COLOCATION BUILD VS. BUY

Outside plant solutions for multisystem operators

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Site Preparation for ClearCube Installation. Rev. F

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

SDN and NFV gaining traction: is your infrastructure ready? White paper

SmartMod Intelligent, Integrated Infrastructure for the Data Center

Miniature outside plant plug-and-play solutions. White paper

CommScope standard density fiber optic panels

The SYSTIMAX GigaSPEED X10D solution. The infrastructure modern enterprises and data centers depend on

Next Generation Frame - Black (NGFB) Optical Distribution Frame Solution

CommScope standard density fiber optic panels. High-performance communication solutions

INNOVATE DESIGN APPLY.

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Rack & Enclosure Systems

INNOVATE DESIGN APPLY.

Dude Solutions Business Continuity Overview

Data Center Operations Guide

Laying the groundwork for a new level of Power over Ethernet

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

5G shaping the always on networks of tomorrow

White Paper Technology Infrastructure Upgrade Boosts Performance of Older Buildings In today s environment, older buildings need to support ongoing fu

ENCLOSURE HEAT DISSIPATION

Why Enterprises Need to Optimize Their Data Centers

World Class. Globally Certified. High Availability.

IN-BUILDING WIRELESS BEST PRACTICES CHAPTER 5

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Overcoming the Challenges of Server Virtualisation

AMS6, Amstel Business Park Campus. Highly connected, Energy efficient data centre. Duivendrechtse kade 80A 1096 AH Amsterdam Netherlands

What can the OnBase Cloud do for you? lbmctech.com

Run a Smart Workplace Introducing the Digital Building. Digital Building Solutions

DATACENTER COLOCATION. Flexible, Secure and Connected

TB+ 1.5 Billion+ The OnBase Cloud by Hyland 600,000,000+ content stored. pages stored

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Thermal management. Thermal management

Trends in Data Centre

Data Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM

(Data Center Networks & Cloud Computing Security)

Building Management Solutions. for Data Centers and Mission Critical Facilities

DATACENTER BERLIN Definitely a Good Perspective

FTT-ACP: Ready for the future in building cabling WHITEPAPER

Google s Green Data Centers: Network POP Case Study

Data Centre In A Box

Choosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope

SMARTMOD Intelligent, Integrated Infrastructure for the Data Center

The Evolving Data Center

2016 COOLING THE EDGE SURVEY. Conducted by Vertiv Publication Date: August 30, 2016

3M Data Center Solutions. Innovation. is the. Solution

Howard Crabtree Berk-Tek

CommScope Multi-Tenant Data Center Solutions: A solid advantage from the critical infrastructure experts. Data Center Solutions

CenturyLink Data Center Services Omaha, Nebraska

NETCONNECT. Structured Cabling Solutions Guide. Asia-Pacific Region

Cisco EnergyWise Optimize and Cost Saving. Traditional IT Power Management

Transcription:

Checklist for building an edge data center

Building an edge data center to provide a cloud computing environment within a service provider central office can be a complex endeavor. It requires lots of planning and preparation to ensure that it can deliver the necessary end goals. Service providers are increasingly moving towards leveraging the architectures and technologies of software-defined network (SDN) and network function virtualization (NFV) to be more agile bringing new services online faster, and saving on both CapEx and OpEx through efficiencies. Convergence of wireline and wireless networks, and the need for higher bandwidth with lower latency is driving the cloud computing environments to the edge of the networks. Central offices (CO) are typically on the network edge as that is where the access network (fiber optic cables) terminate, and thus are prime locations for an edge data center. Because cloud computing and SDN/NFV technology is constantly evolving, the edge cloud computing environment design and supporting fiber infrastructure must take into consideration what the future may bring and how this new environment or edge data center might take advantage of this. To help plan a successful edge data center, CommScope has created a preliminary checklist and tips to consider for: 1. Location 2. Power 3. Heating and Cooling 4. Design 5. Physical Infrastructure Layer 2 Checklist for building an edge data center

1. Location Location refers to both the geographic area where a service provider plans to place or build an edge data center and the actual physical site itself. Once a possible site has been identified that seems to satisfy the requirements, the next step is to determine if the potential building can accommodate the needs of an edge data center. What is the best location for the edge data center? How close is it to the desired target market? Is the geographical location prone to natural disasters such as earthquakes, floods, hurricanes, tornadoes, ice storms or excessive heat? How much square footage is available in nearby existing facilities or central offices? If an existing site has limited room, is there room outside of the building that can house a modular data center solution? Or, is there an opportunity to retire and remove old equipment? How many racks or cabinets initially will be installed? What will the data center look like 3 to 5 years from now? Does the building already have any infrastructure already in place? If not, how easily can this building be retrofitted? Does the building currently have sufficient power? See Power below for questions to consider. Does this building have adequate heating and air conditioning? See Heating & Cooling below for more questions to consider. Can the building obtain multiple high-speed network links? Ideally, network connections should enter and exit at different points in the building. Does the building have a lot of windows? Windowless facilities are best to better control indoor climate and security. Are pathways such as doors, aisles, hallways and freight elevators large enough for equipment, racks and/or cabinets to be moved in and out? Do regulations or internal rules require that the edge data center area be physically separated from the rest of the telecom space in for example an existing central office? Does the edge data center space need to be separated by a physical firewall? 2. Power Power planning for today and for the future is one of the most critical items in the edge data center. To ensure the edge data center is always operational, consider redundancies that meet the service provider s requirements and plan accordingly. Can the utility company or multiple companies provide enough power now and in the future? Can the building be serviced by multiple utility grids? In a best-case scenario, power should enter the facility from different entrance points. Can power be supplied directly or will conversion equipment be required? Consider conditioning the electrical power to avoid spikes or surges. Is there enough back-up power from the generators? How many uninterrupted power supplies (UPSes) have been planned to be used? UPSes should support the entire infrastructure for at least 150% of the time it takes for generators to come online. What is the average power requirement per rack or cabinet? Typical data center racks require 5-10 kw of power while ultra-high density racks may need up to 50-60 kw. Generators should be able to support the edge data center for at least 48 hours during a power outage. Checklist for building an edge data center 3

3. Heating & Cooling Heating, venting and air conditioning (HVAC) is essential to the successful operation of a data center. Since nearly 50 percent of all power used by a data center is eaten up by HVAC, making this function as efficient as possible is vital to OpEx. How many BTUs can the space/building support? Ideally, the ambient temperature should remain around 70 74 F (21 23 C) with 45 50 percent humidity. How will the data center s temperature be monitored? Utilizing temperature sensors on the racks are the best way to monitor temperature. How will the data center be cooled? Consider a plan to minimize climate control costs. Adopting a free-cooling design can also be a costeffective solution to temperature control. Consider walling off or utilizing curtains to better control the climate off the data center equipment. Controlling humidity and dust is critical to healthy servers and switches. Using a hot-aisle/cold-aisle design can simplify temperature control. Raised floors must be constructed if cooling the data center from below. Slab floors can work well too, but often require in-aisle cooling solutions 4. Design Whether converting a telecom site like a central office or building a data center from scratch, one crucial part of design is planning the infrastructure. The following are a few questions regarding overall design and security. Does the data center design account for lighting? LED lighting uses the least amount of power and doesn t generate heat. Is there a plan to secure the physical premises? Consider biometrics in addition to key cards for an extra layer of security. Consider a way of protecting rows or racks of equipment from visitors if creating a customer co-location area. Does the facility have enough fire alarms and escapes? Local codes inform how fire safety preparations should be made. What kind of fire suppression system is right for the data center? To prevent expensive equipment from getting wet, special inert gas fire-suppression systems are often employed. 4 Checklist for building an edge data center

5. Physical Layer Infrastructure To gain maximum benefit of cloud computing and software-defined networking/network function virtualization (SDN/NFV), the physical layer of the edge data center must be seriously examined. Since the lifecycle of most SDN/NFV equipment lasts about every 2 3 years, planning of the physical layer infrastructure to support future technology and connectivity is essential. CENTRAL OFFICE Physical Network Function High Low Speed Speed IO IO EDGE DATA CENTER WITHIN CO Switches Core Network A Ethernet Ethernet Links Links Leaf Leaf Leaf Leaf Leaf Leaf Leaf Leaf B Access Network Leaf Switches ODF Edge Devices Consider a phased 3 to 5-year roadmap for the data center architecture. The physical layer infrastructure should be designed to support multiple upgrades with migration paths that can support up to at least 400G. Because many carriers/service-providers will build the majority of their SDN/NFV or Cloud/ compute environments on the edge of the network (CO, MTSO, CRAN Hub, regional DC), the size and scale of these environments should be such that the physical infrastructure requirements can be supported by multimode fiber optic cabling. Data center designs that propose longer channel paths or extra connections should consider components that adhere to loss budget parameters. CommScope s unique design tools can help speed and simplify design and planning. Our application support guidelines provide the supportable distance limits for every supported application based on fiber type, connector type and number of connectors. Once the components are installed, our unique link loss calculator confirms the correct installation. Our link loss/ fiber performance calculator can be downloaded for free. The data center should easily support both duplex and parallel applications. Consider CommScope s MPO-24 with LazrSPEED OM5 to provide duplex and parallel fiber value and migration flexibility. The MPO-24 solution offers multiple parallel (MPO-8, MPO-12 or MPO-24) and/or duplex ports via a single MPO-24 trunk. For additional information on CommScope s High Speed Migration fiber infrastructure solutions please go to: www.commscope.com/hsm/ Is there a plan to manage the infrastructure and its connectivity as the data center grows? Consider using automated infrastructure management (AIM) systems to help the data center become more efficient from tracking down ghost ports or switches and loose connections to providing detailed mapping for moves, adds or changes. Since there is so much that goes into planning and designing an edge data center, this checklist cannot possibly cover every detail of any given project. CommScope and our PartnerPRO network of local experts around the globe would be happy to work with you to make sure that a service provider s future edge data center becomes everything they want it to be. Checklist for building an edge data center 5

CommScope (NASDAQ: COMM) helps design, build and manage wired and wireless networks around the world. As a communications infrastructure leader, we shape the always-on networks of tomorrow. For more than 40 years, our global team of greater than 20,000 employees, innovators and technologists has empowered customers in all regions of the world to anticipate what s next and push the boundaries of what s possible. Discover more at commscope.com commscope.com Visit our website or contact your local CommScope representative for more information. 2018 CommScope, Inc. All rights reserved. Unless otherwise noted, all trademarks identified by or are registered trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. CommScope is committed to the highest standards of business integrity and environmental sustainability with a number of CommScope s facilities across the globe certified in accordance with international standards, including ISO 9001, TL 9000, and ISO 14001. Further information regarding CommScope s commitment can be found at www.commscope.com/about-us/corporate-responsibility-and-sustainability. CO-111612.1-EN (03/18)