Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Similar documents
Electronic earth leakage protection relay

Multi-Point Gas Detection and Control System

Protection Relays PHASE & RESIDUAL OVERCURRENT

Multifunction Transducer MT440

Voltage Transducer UMT516 / MT516

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

100% electricity. Automatic transfer switch controllers ATL series

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

Multi-Point Gas Detection and Control System

SX90 Process Controller

Multi-Point Gas Detection and Control System

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

EC700. Pulses concentrator. User instructions

HIGH-VOLTAGE DC METER

Instruction Manual. ICENI/MA-01 MODBUS Master Module. Pub_ Issue 1

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

High Voltage DC Meter

Neon pr. ph/ ORP measurement. Applications. Description

COUNTIS ATv2/ATiv2 GB

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

Installation and User Guide

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Power Meter PowerMonitor 500

Any device, including routers and hosts, is running an implementation of IP address Host

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

Trident and Trident X2 Digital Process and Temperature Panel Meter

SINGLE-CHANNEL PROCESS INDICATOR series 8001

Technical Specificaions. kwh Energy Meter

ATS Automatic transfer switches Advanced version

ANALIZZATORE DI RETE TRIFASE 90A

DIGITAL PROCESS CONTROLLER

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

ACUREV Three-Phased DIN-Rail Multifunction Meter FEATURES

Carbon Monoxide (CO) Gas Detection and Control System

User Manual. KE-Relay or KD-Relay Profibus DPV0 Communication Module. Page 1 / 18. KE-PROFI-DP0 Version (NE_NC-KE-PROFI-DP0_MAN_01_10_FN04)

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Digital multimeters DMG

Technical data. Safety notes. Product features

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35TF V AC

02/11/2015

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Technical Specifications. Dual Source kwh Energy Meter

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

HAT160 ATS CONTROLLER USER MANUAL

Digital Panel Meters Modular signal s conditioner Type USC-DIN

AS-i Safety Output Module, IP20

CEM-C30 INSTRUCTION MANUAL (M017B A)

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

COUNTIS Ci Notice d utilisation GB Operating instructions Bedienungsanleitung NL Gebruiksaanwijzing

MDC-20. Maximum Demand predictive Control. Description

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Hoist Controller for Low Voltage Hoist Instruction Manual

LCI User Manual mantracourt.com

MPR-4 SERIES NETWORK ANALYSER USER MANUAL

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

Interface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

EXOcompact. Third generation freely programmable controllers

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

POWER FACTOR REGULATOR

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

SIL 2/3 Relays for all applications, with or without Line & Load Diagnostics. Product presentation

Faults on the system Proximity switch connection technology:

FLÄKTGROUP OFFERS A WIDE RANGE OF PER- MANENT MAGNET MOTORS (PM) AND FREQUENCY CONVERTERS FOR PLUG FANS. POWER RANGE IS FROM 0,8 KW TO 15 KW.

HAT162 ATS CONTROLLER USER MANUAL

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0

KS5 SYNCHRONIZATION METER

Safety Control Relay Product Catalog

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Process & Temperature Digital Panel Meter

COUNTIS ECi2 ECi3. Operating instructions Multi-utility pulse concentrator F GB D I NL E P

ISOPAK1xx 24 channel earth leakage monitoring of LIVE AC networks

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

Technical Specifications. Multi Function Meter

SMARTSCAN INFORMATION

MCX08M2 Programmable controller

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

PGR-3200 MANUAL INSULATION MONITOR

MIC-2 MKII, Multi-instrument DATA SHEET

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

Technical Specifications. Dual Source Energy Meter (EB / DG)

Transcription:

Page 1 of 5 2017 03 20 User Manual Iso DIN Iso DIN User Manual 1 channel Earth Fault Monitoring Megacon AB Ranhammarsvägen 20 S 168 67 Bromma Sweden Tel: 08 402 42 50 sales@megacon.se www.megacon.se eee

WARNING! Carefully read the manual before the installation or use. This device is to be installed by qualified personnel, complying to current standards, to avoid damages. Before any maintenance operation on the device, remove supply inputs. Products illustrated herein are subject to alteration and changes without prior notice. Description Earth leakage relay type A DIN modular box (2 modules) Backlighted LCD display True RMS External residual current transformer Fail safe function (settable) Visualization of the differential current and the instrument s status Modbus-RTU RS485 interface communication On the front panel, TEST and RESET button Display functions Thanks to LCD display, the user can view very quickly the measurements, the alarms and can access to all settings. Green: detected current lower than set threshold Yellow: detected current higher than WARNING threshold but lower than ALARM threshold Flashing yellow: short circuit on residual current transformer Red: detected current higher than ALARM threshold and relay activation Flashing red: open residual current transformer circuit (or not connected) Blue: device setting menu Keyboard functions RESET key To reset the relay after tripping TEST key Causes tripping of the relay Press RESET key at least 2 seconds Used to enter settings menu. Into menu setting the RESET key Used to scroll menu pages. Into menu setting the TEST key Used to select among possible choices and to modify settings (increment-decrement). Viewing Current measurement Fault current to earth setting Tripping time setting Automatic reset or manual reset FS: positive safety activated on TRIP relay Hysteresis setting Warning and Alarm advance set-point ON LED: indicates the presence of aux supply COMM LED: indicates communication traffic Iso DIN User Manual IM260 U M v0.1 Page 2 of 5

Main menu The following table lists the available sub-menus: MENU DESCRIPTION ACTION Tripping delay time, fault current to earth setting, automatic or manual reset, positive safety on TRIP relay, hysteresis setting, warning and alarm advance set-point SER COM Communication ports parameters UTILITY Language, display, access code enabling RESET All setup parameters are reset to factory default values ACTION CURRENT Default Range I 300mA 30mA 30A Warning 33% OFF 25% trip value Alarm 90% 25% 90% Hysteresis 5% 0% 25% I Constant selection for fault current to earth. Warning Above this value the device is in alarm (yellow color display). Alarm Above this value we will have a tripping relay (red color display). Hysteresis Percentage of the alarm current. Under this value the relay come back to the rest (after one reset). ACTION TIME Default Range Time 20mS 20ms 10s Time Constant selection for tripping delay time. ACTION RELAY Default Range Failsafe OFF OFF - ON Failsafe OFF = positive failsafe deactivated. Output relay normally de-energized. ON = positive failsafe activated. In this condition the output relay energized. ACTION RESET Default Range Reset mode MANUAL AUTO - MANUAL Reset mode AUTO = automatic reset. MANUAL = manual reset through RESET key on the front. ACTION FILTER Default Range Filter NO NO - YES Filter NO = no filter applied. YES = filter applied. SER COM Default Range Address 01 01-247 Baud rate 38400 bps 4800-9600 - 19200-38400 - 57600-115200 Parity no parity no parity odd - even Stop bit 1 1-2 Address Serial address for the communication protocol. Baud rate Serial communication speed. Parity Data format. Bit stop Number of stop bits. UTILITY Default Range Language English English - Italiano - Francais - Espanol - Deutch T. LCD on 1 m ON / 15 s 1h T. exit 1 m NO / 15 s 1h Password 0 0-9999 Language Set language menu. T. LCD on Turn-on time of the display after the last press of a key; with ON it remains always ON. T. exit Permanence time in the Setup after the last press of a key. Password Value to be specified to access at setup parameter. RESET Default Range Setup NO NO - YES Setup All setup parameters are reset to factory default value. Iso DIN User Manual IM260 U M v0.1 Page 3 of 5

Wiring diagrams Vaux RS485 Aux1 Aux2 -B +A 6 7 8 9 10 11 Auxiliary power supply Power supply is connected to terminals (6) and (7). Relay output Relay output to the terminals (3), (4) and (5). 1 2 S1 S2 Iso-DIN Output Relay 3 4 Com 5 NC Communication interface The RS485 serial interface is connected to the terminals (9), (10) and (11). Connection to the residual current transformer: The current transformer is connected to the S1 (1) and S2 (2) terminals. Ba: Shunt coil Ba S1 S2 Load L1 L2 L3 N Mechanical dimensions (mm) Iso DIN User Manual IM260 U M v0.1 Page 4 of 5

Technical characteristics Auxiliary supply Rated voltage 230VAC ±20% 115VAC ±20% (option) Frequency 50 60Hz Power consumption 2VA max Output Relay status Normally de-energized (Fail Safe OFF) Configuration contacts 1 changeover contact SPDT (NO, C, NC) Maximum load user outputs 5A 250 VAC Insulation Insulation test 2,5kV for 1 minute RS485 serial interface Baud-rate Programmable 4800 115200 bps Ambient operating conditions Operating temperature -10 60 C Storage temperature -20 80 C Relative humidity 90% Housing Version 2 DIN modules Degree of protection IP40 on front (with cover) IP20 housing and terminals Weight 200g Certifications and compliance Reference standards CEI EN60947-2 annex M Iso DIN User Manual IM260 U M v0.1 Page 5 of 5