Expansion Module HZS 541-1S

Similar documents
HZS Internal Controller Expansion

Internal Buffer/Boiler Module HZS 534

HZS Solar Module

Auxiliary Board MP-Bus HZS 562

C-DIAS Digital Input Module CDI 161 with 16 inputs

VARAN Splitter Module VSV 041

VARAN Splitter PROFINET VSP 044

VARAN Digital Combined Module VDM 086

VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems

Protected VARAN Digital Mixed Module PVDM 086

VARAN Splitter Module VSV 043

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

C-DIAS Temperature sensing module CAI x temp. inputs C 8 x digital outputs +24V

ISE 021 S-DIAS Interface Module RS232 / RS485

C-DIAS Analogue Conversion Module CAM 011 for 3 x 0-10V DC inputs 2 x PT100 inputs and 1 x ±10V output

C-DIAS Analogue Output Module CAO 081 for eight 10V DC outputs

C-DIAS-Temperature Recording module CAI x Temp. inputs 50 C to +150 C

VARAN Splitter PROFINET VSP 042

TO 161 S-DIAS Digital Output Module

C-DIAS Analogue Conversion Module CAM 124 for eight 0 10V DC inputs and four 10V outputs

DIAS Interface Module VARAN DIV 511

ETT 312 Build-In Touch Terminal

Non-communicating room controllers

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter

ICA 012 S-DIAS Interface Module CAN

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

EX-RC1 Remote I/O Adapter

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Keyboard Unit Sigmatek

AO 081 S-DIAS Analog Output Module

MINI MCR-SL-UI-REL(-SP)

MBM - Modular I/O system IP20

PS 101 S-DIAS Power Supply Module

Measurement Systems Datascan Installation and User Guide

DM 161 S-DIAS Digital Mixed Module

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Cube67 - Modular I/O station

VARAN Manager PCI Insert module PCV 521 Versatile Automation Random Access Network

to 12a Added Standard and Electrical requirements for UL table 1.1

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Time Counters mini "h", DC Version

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

IST ULTRASTAB Power Supply for high precision transducers

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

TM3TI4 module TM3-4 inputs temperature

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

AI 046 S-DIAS Analog Input Module

170 ADI VDC - 16 Pt. Discrete Input Module Base

C-DIAS EtherNet/IP Slave CIP 022

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

mark150s mark150/485s DDC controllers Summary

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

RO 051 S-DIAS Relay Output Module

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TCNM-ACBB1 Installation Manual

QUINT-BUFFER/24DC/24DC/40

C-DIAS Serial Interface CSI 021

HZS 351 Room Touch Control Panel

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit

Small distributed I/O module

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

SI 021 S-DIAS SSI Interface Module

Operating instructions. Speed monitor D / / 2014

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

Product and functional description

Analog Modules AS-i, IP67, M12

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

VARAN-INTERFACE VAC 012

Operating instructions. Switching amplifier DN0210 DN / / 2015

BMF400 Input/output module

TM3AI4 module TM3-4 analog inputs

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Non-communicating room controllers

XT-9100 Technical Bulletin

Temperature controller Ducted systems

EY-EM : Remote I/O module, ecolink

Product and functional description

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

TM3TI8T module TM3-8 inputs temperature

DIN Rail. user manual Models , & INT /503556/ UM

PC 521 Data Recording PC

HZS 352 Touch Room Unit

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Screw terminal panels, Relay output boards, connection cables

IMIO100 IMIO105. DDC controllers. Summary

VI 021 S-DIAS VARAN Control Module

Transcription:

Expansion Module HZS 541-1S 12.10.2015 Page 1

System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs to connect PT1000/KTY81 sensors or room units and a digital input. The electronics are built into an IP2x-sealed plastic housing and can be mounted on a wall or DIN rails. With installation into the IP2x-sealed plastic housing, the seal required for the heating rooms is achieved using PG screw fittings. Replacement fuses are also provided in the cover of the plastic housing. Communication with the other expansion modules or CPU is made over the CAN bus. The CAN bus or 230 V AC supply is connected to the electronics and can be extended to other electronics. For this extension, terminals are provided so that redundant connections can be avoided. The supply for the internal electronics is generated through a transformer; no additional power supplies must therefore be connected. The module also provides the option to monitor relay supply over an external temperature monitor. If no temperature monitor is connected, a bridge must be provided at X3. Otherwise, no voltage is applied to the relays! Delivered with X3 bridged! Page 2 12.10.2015

Configuration 1x Digital input 4x relay outputs 3 A 3x PT1000 inputs (-50 +200 C) or 3x KTY81-110 (-25 +100 C) or 3x KTY81-122 (-25 +100 C) 1x analog input for room unit RTV 12.10.2015 Page 3

Technical Data Controller performance data Processor Internal program memory (Flash- PROM) Internal data and/or program buffering (internal EEPROM) Interfaces AT90CAN32 32 kbytes (Flash) 1-kbyte (Flash), no buffer battery required! 1x CAN-Bus Electrical requirements Supply voltage for the relays and internal electronics Power supply frequency Current consumption electronics Current consumption of electronics and connected loads Fuses 230 V AC ±10% 50-60 Hz 15 ma maximum 10 A 10 A (F2) for the relay outputs 250 ma (F1) for the transformer Relay specifications Output voltage Max. Output current 230 V 3 A Number of relays 4 Relay types Switching time normally open <10 ms The relay outputs can only be switched individually and a maximum of only 3 relay outputs can be on at the same time! Switching several relays simultaneously causes the supply voltage for the electronics to fail. Page 4 a 12.10.2015

Temperature input specifications for KTY81-110 / KTY81-122 or (PT1000) Number of inputs 3 Applicable sensor Type KTY81-110 KTY81-122 PT1000 Measurement range -30 +145 C -30 +145 C -50 +170 C Sensor range 623.6-2170 629.9-2191.9 803.1-1647.7 Resolution 0.2 C 0.2 C 0.2 C Typical current measurement Input resistance Input filter 1.1 ma 8.2 K 100 ms Measurement precision ±0.5 C ±0.5 C ±0.5 C Input filter step response PT1000/KTY81-110/KTY81-122 Voltage on ADC [V] Time [ms] 12.10.2015 Page 5

Room unit specifications Number of room unit connections 1 Temperature sensor type Temperature sensor range PT1000/KTY81-110/KTY81-122/NI1000-25 +100 C PT1000 KTY81-110 KTY81-122 NI1000 Sensor temperature -25 C typ. 902 Ω typ. 654 Ω typ. 660 Ω typ. 867 Ω Sensor temperature 100 C typ. 1385 Ω typ. 1696 Ω typ. 1713 Ω typ. 1618 Ω Mode selector switch (MSS) night automatic day Set value change +5 C typ. 1335 typ. 1665 typ. 1004 Set value change 0 C typ. 1380 typ. 1710 typ. 1050 Set value change -5 C typ. 1423 typ. 1753 typ. 1092 Resolution temperature sensor Resolution MSS set value change Measure management temperature sensor Measurement precision MSS set value change Input resistance Input filter 0,6 0,6 ±2 ±2 4.7 K 100 ms The room unit RTV (05-895-541-Z10) with the KTY81-122 sensor can be ordered from SIGMATEK. Room units with PT1000, KTY81-110 or NI1000 can be directly ordered from Co. EAP. Page 6 12.10.2015

Digital input specifications Input voltage typically +24 V maximum +30 V Signal level low: <+8 V high: >+14 V Switching threshold Input current Input delay typically +11 V 5 ma at +24 V typically 5 ms Number 1 Terminal requirements Connection technology Connector terminals are not included in delivery! The following sprint terminals are required: 5x FK-MCP1,5/2-ST-3,5 Phoenix Contact spring terminal connector 2x FK-MCP1.5/3-ST-3.5 Phoenix Contact spring terminal connector 4x FKC2.5/3-ST-5.08 Phoenix Contact spring terminal connector 1x FKC2.5/4-ST-5.08 Phoenix Contact spring terminal connector 12.10.2015 Page 7

Miscellaneous Article Number 05-895-541-1S Hardware version 2.x Station number HW classes set over DIP-switch, maximum of 255 participants possible HZS54x Environmental conditions Storage temperature -20 +70 C Operating temperature 0-60 C Humidity 0-95 %, non-condensing EMC stability according to EN 61000-6-2:2001 Shock resistance EN 60068-2-27 150 m/s² Housing protection type IP2x Page 8 12.10.2015

Mechanical Dimensions 12.10.2015 Page 9

Terminal Overview Page 10 12.10.2015

Terminal Layout X1: 230 V AC power line 3-pin Phoenix RM5.08 connector 1 Phase 2 Neutral 3 Earth wire X2: 230 V AC power dissipation 3-pin Phoenix RM5.08 connector 1 Phase 2 Neutral 3 Earth wire X3: Temperature monitor (Standard: clip) 1 Phase 2 Relay supply phase If no external temperature monitor is connected, pins 1 and 2 must be connected to one another with a bridge. X4: 230 V AC relay output 3 A 3-pin Phoenix RM5.08 connector 1 LR1 2 N 3 PE 12.10.2015 Page 11

X5: 230 V AC relay output 3 A 4-pin Phoenix RM5.08 connector 1 LR2 2 LR3 3 N 4 PE X6: 230 V AC relay output 3 A 3-pin Phoenix RM5.08 connector 1 LR4 2 N 3 PE X8 Temperature input (AI1) 2-pin Phoenix connector RM 3.5 1 AI1 2 AGND X9 Temperature input (AI2) 2-pin Phoenix connector RM 3.5 1 AI2 2 AGND Page 12 12.10.2015

X10 Temperature input (AI3) 2-pin Phoenix connector RM 3.5 1 AI3 2 AGND X12: Room unit analog inputs (AI4 and AI5) 3-pin Phoenix RM3.5 connector 1 room temperature 2 mode and room correction 3 AGND X13: digital input (DI1) 3-pin Phoenix RM3.5 connector 1 +24 V 2 DI1 3 GND The internal +24 V for the electronics cannot draw more than 10 ma! Thereby, a maximum of only 3 relays can be on at the same time! 12.10.2015 Page 13

X14: CAN-Bus IN CAN-Bus connection 2-pin Phoenix connector RM 3.5 1 CAN A (CAN LOW) 2 CAN B (High) X15 CAN-Bus OUT CAN-Bus connection 2-pin Phoenix connector RM 3.5 1 CAN A (CAN LOW) 2 CAN B (High) X16: Ground connection Page 14 12.10.2015

Included with delivery are dummy covers on the cable inlets, which can be replaced with PG7 (low voltage lines) or PG11 (230 V lines) screw fittings as required. The fittings are not included with delivery! Opening the cover and connecting the cable can only be done by trained personnel and with the 230 V AC power supply disconnected! Current safety regulations and rules must be observed! Do not connect wiring while voltage is applied! X1 (current supply IN 230 V AC) can only be supplied with power after the wiring has been completed and the housing closed. CAUTION: On the circuit board, it is possible to come into contact with 230 V voltages! Do not insert connectors while voltage is applied! DIP-Switch Station Numbers (binary) E.g.: = 1 = 255 = 81 12.10.2015 Page 15

CAN BUS Setup This section explains how to configure a CAN bus correctly. The following parameters must first be set: Station number CAN bus station number Each CAN bus station is assigned its own station number (can be set from 0 to 255) With this station number, data can be exchanged with other stations connected to the bus. Up to 255 stations can be installed in a CAN bus system. In a CAN bus system however, each station number can only be assigned once. SW 1 SW 2 SW 3 SW 4 SW5 SW6 SW7 SW8 Station 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 2 1 1 0 0 0 0 0 0 3 0 0 1 0 0 0 0 0 4 1 0 1 0 0 0 0 0 5 0 1 1 0 0 0 0 0 6 1 1 1 0 0 0 0 0 7 0 0 0 1 0 0 0 0 8 1 0 0 1 0 0 0 0 9 0 1 0 1 0 0 0 0 10 1 1 0 1 0 0 0 0 11 0 0 1 1 0 0 0 0 12 1 0 1 1 0 0 0 0 13 0 1 1 1 0 0 0 0 14 1 1 1 1 0 0 0 0 15 0 0 0 0 1 0 0 0 16... 1 1 0 1 1 1 1 1 251 0 0 1 1 1 1 1 1 252 1 0 1 1 1 1 1 1 253 0 1 1 1 1 1 1 1 254 1 1 1 1 1 1 1 1 255 A terminating resistor (150 R) must be inserted at the end of the CAN bus. Page 16 12.10.2015 a

Status LED LED Status LED blinks (20 Hz) LED blinks (4 Hz) LED blinks (1 Hz) LED off Definition general error controller is running, CAN bus communication with CPU active controller is running, CAN bus communication with CPU inactive controller not active, no supply 12.10.2015 Page 17

Wiring Guidelines The signals recorded by the analog inputs are very small in comparison to the digital signals. To ensure error-free operation, a careful wiring method must be followed: The lines connected to the source of the analog signals must be as short as possible and parallel wiring to digital signal lines must be avoided. The signal lines must be shielded. 230 V AC lines (power circuit and relay outputs etc.) must not be wired parallel to analog and digital input lines. Wiring guidelines for digital inputs The input filters used, which suppress noise signals, allow operation in harsh environmental conditions. In addition, a careful wiring method is recommended to ensure error-free function. The following guidelines should be observed: Avoid parallel connections between input lines and load bearing or AC circuits. Correct wiring to mass General information on the relay outputs All relay coils are powered by the internal +24 V DC supply. The cross sectional area of the relay outputs must be large enough for the maximum continuous current at 230 V AC for each connected load as used in the specifications for the relay outputs. It is important to note that at high currents, thermal loads affect the wiring and with continuous over loading can lead to a break down! Hi voltages can current leakage or arcing between different potentials! To ensure error-free operation, a careful wiring method must be followed. Avoid parallel wiring between input lines and load-bearing circuits. Page 18 12.10.2015

Wiring guidelines for analog inputs The analog signals are very small in comparison to the digital signals. To ensure error-free operation, a careful wiring method must be followed. The connection lines to the source of the analog signals must be as short as possible and parallel wiring to digital signal lines or AC circuits must be avoided. The signal lines should be 2-pin shielded or twisted pair wires. CAN bus wiring guidelines For the CAN bus wiring, twisted-pair shielded wires must be used. The cable shielding must be connected to earth either directly before the terminal over a large surface and with low Ohms (grounding clamps) or with a blade terminal. Noise signals can therefore be prohibited from reaching the electronics and affecting the function. Temperature Measurement with Thermo Resistors 2-wire measurement The 2-wire measurement is only recommended for short sensor wires, as the resistance of the wire affects the measurement. The positive input must be connected with the reference output and the negative input with analog GND. 12.10.2015 Page 19

Analog Input Specifications Temperature resistors Measurement range Measurement range 1: KTY81-110 Measurement range 2: KTY81-122 Measurement range 3: PT1000 Input filter 640-1780 653-1696 (-25 +100 C) resolution: 0.15 C/d 660-1717 (-25 +100 C) resolution: 0.15 C/d 803-1758,6 (-50 +200 C) resolution: 0.35 C/d 100 ms Page 20 12.10.2015

Room temperature setting (X12) If a room temperature switch is used to regulate floor heating, it must be connected with the module according to the following connector layout at X12. Individual Adjust Room temperature by +/- 5 C Individual Adjust Room temperature by ±5 C To connect the room unit, use a 3-wire cable with a minimum cross section of 0.25 mm² (maximum 1.5 mm²) (e.g. LiYY 3x0.25 or LiYY 3x1.5)! 12.10.2015 Page 21

Page 22 12.10.2015