See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Similar documents
See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at



See instructions to download and install the latest version of LinkBoxLON and the user's manual at

IntesisBox Modbus Server Panasonic

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server KILSEN KSA-7xx. User s Manual 08/2013 r1.2 eng

IntesisBox KNX - BACnet/IP Client

IntesisBox BACnet/IP Server DALI

IntesisBox KNX SAMSUNG NASA Air Conditioners

IntesisBox Modbus Server KNX

IntesisBox Modbus Server - Honeywell XLS 80

Modbus Server SIEMENS Algorex (printer port)

---- IntesisBox KNX Modbus RTU Master and Modbus TCP Client

IntesisBox Modbus Server - BACnet/IP Client

IntesisBox Modbus Server LG Air Conditioning. User s Manual Issue Date: 06/2016 r1 eng

IntesisBox Modbus Server Siemens Synova FC330A

IntesisBox KNX - AIRZONE

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

IBOX Modbus Server ESSER 8xxx/IQ8/FlexES fire panels

IntesisBox BACnet IP Server - M-Bus

IntesisBox KNX - BACnet/IP Client

IntesisBox. KNX - Mitsubishi Electric G50. Gateway for integration of Mitsubishi Electric City Multi air conditioners into KNX control systems.

IntesisBox Modbus Server M-Bus

IntesisBox KNX - Mitsubishi Electric G50

IntesisBox LON - KNX

IntesisBox Modbus Server - LON

IntesisBox ASCII Server - KNX

Gateway for integration of Modbus RTU slave devices into BACnet IP based systems.

Modbus Server - Mitsubishi Electric G50

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

ASCII Server - BACnet/IP Client. Gateway for integration of BACnet IP devices into ASCII enabled control systems.

Modbus Server - Mitsubishi Electric G50

IntesisBox BACnet/IP Server Modbus TCP Master

IntesisBox ME-AC-BAC-1

IntesisBox BACnet/IP Server Modbus RTU Master

IntesisBox BACnet/IP Server M-Bus meters

Modbus Server - Mitsubishi Electric G50

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

IntesisBox Modbus Server BACnet MSTP and BACnet/IP client

IntesisBox Modbus Server Mitsubishi Electric Centralized Controller TCP/IP XML. User Manual Issue Date: 01/2018 r1.0 EN

F1000 User's Manual. (Version: V1.01)

IntesisBox KNX. Mitsubishi Electric G-50A/GB-50A/GB-50ADA/AG-150A. User's Manual Issue date: 03/08/2012 r21 eng

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

IntesisBox ASCII Server KNX

IntesisBox. v.0.1. User Manual Issue Date: 12/2017 r1.3 EN

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Product and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

IntesisBox Modbus Server BACnet/IP Client

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Push Button Interface UP 220D31

TCNM-ACBB1 Installation Manual

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

KFC-200. Installation Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

16- or 24-port Managed Switching Hubs

IntesisBox PA-AW-MBS-1 v.2.0

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

IntesisBox SMS - Mitsubishi Electric air conditioners

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

Rugged Industrial Media Converter

Industrial Ethernet Switch

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

Operating and mounting instructions

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Installation manual for for Schleifenbauer DPM3

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

User Manual EKI-6528TI/ 6528TPI. EN port M12 Unmanaged/ PoE Switch with Wide Temperature

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

RXTH DUAL ROOM SENSOR / SWITCH

ADA User manual ADA RS-485 / RS-422 to RS-232 Converter. 1 io_ada-4010_v3.22_en. Copyright CEL-MAR sp.j.

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

Transcription:

Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any other equipment connected to it. IntesisBox must be installed by accredited electrician or similar technical personnel, following all the safety instructions given here, and in accordance always with the country legislation for installation of electric equipment. IntesisBox can not be installed outdoors or exposed to direct solar radiation, water, high relative humidity or dust. IntesisBox must only be installed in a restricted access location In case of wall mount, fix firmly IntesisBox on a not vibrating surface following the instructions below. In case of DIN rail mount fix IntesisBox properly to the DIN rail following the instructions below. Mounting on DIN rail inside a metallic cabinet properly connected to earth is recommended. Disconnect always power of any wires before manipulating and connecting them to IntesisBox. A power supply with a NEC Class 2 or Limited Source (LPS) and SELV rated is to be used. Respect always the expected polarity of power and communication cables when connecting them to IntesisBox. Supply always a correct voltage to power IntesisBox, see details of voltage range admitted by the device in the technical characteristics below. This device was designed for installation in an enclosure. To avoid electrostatic discharge to the unit in environments with static levels above 4 kv precautions should be taken when the device is mounted outside an enclosure. When working in an enclosure (ex. making adjustments, setting switches etc.) typical anti-static precautions should be observed before touching the unit Installation instructions Disconnect from mains the power supply before connecting it to IntesisBox. Disconnect power of any bus or communication cable before connecting it to IntesisBox. Mount IntesisBox on the wall or DIN rail following the instruction given below, respecting the safety instructions given above. Connect a NEC Class 2 or Limited Source (LPS) and SELV rated power supply to IntesisBox, respect the polarity if DC power or Line and Neutral if AC power. Apply always a voltage within the range admitted by IntesisBox and of enough power (see technical characteristics). Circuit-breaker must be used before the power supply. Rating 250V-6A Connect the communication cables to IntesisBox, see details on the user's manual. IntesisBox and the rest of devices connected to it. Configuration and setup Use the software LinkBoxMB to configure IntesisBox, follow the instructions of the user's manual for more details. See instructions to download and install the latest version of LinkBoxMB and the user's manual at /down/mb/linkboxmb.html 1 / 5

Wall mount 1. Separate the fixing clips in the bottom of the box, pushing them to the outside until hear the "click" which indicates that now the clips are in position for wall mount, see in the figure below. Botton view of the box Clips in their original position, for DIN rail mount Clips in position for wall mount 2. Use the holes of the clips to fix the box in the wall using screws. Use the template below for the wall holes. 61 mm Ø 3 mm Top view of the box IntesisBox www.intesis.com 100 mm DIN rail mount With the clips of the box in their original position, insert first the box in the upper edge of the DIN rail and later insert the box in the down part of the rail, using a small screwdriver and following the steps in the figure below. Side view of the box 1 DIN Rail 3 2 2 / 5

Connections See Note 1 Modbus TCP master KNX TP-1 (Bus EIB) Ethernet RJ45 - + Ethernet Modbus TCP CMN 24Vac 9-30Vdc Max.125 ma 24Vac Max.127mA 50-60Hz IntesisBox www.intesis.com KNX TP-1 + - master EIA485 EIA485 - + EIA232 PC Console LinkBoxMB Only needed for configuration See Note 3 master EIA232 Console wire 1.8 m long. DB9 Female - DB9 Male standard. It is supplied. Notes: 1. Must use NEC Class 2 or Limited Source (LPS) and SELV rated power supply. If using DC power supply: Respect polarity applied of terminals (+) and (-). Be sure the voltage applied is within the range admitted (9 to 30 Vdc). The power supply can be connected to earth but only through the negative terminal, never through the positive terminal. If using AC power supply: Make sure the voltage applied is of the value admitted (24 Vac). Do not connect any of the terminals of the AC power supply to earth, and make sure the same power supply is not supplying any other device. 2. Modbus connection. Only one Modbus connection type can be used simultaneously: Modbus TCP, EIA485, or EIA232, this must be configured within LinkBoxMB software. Modbus TCP: Connect the cable coming from the Modbus TCP master device to the connector ETH of IntesisBox, use a crossover ethernet CAT5 cable if connecting directly to the Modbus TCP master device, or an straight ethernet CAT5 cable if connecting to a switch or hub of the LAN of the building. If connecting using the LAN of the building contact the network administrator and make sure that TCP/IP traffic and the TCP port used (502 by default) are allowed through all the LAN path. EIA485: Connect the EIA485 bus to the connector EIA485 of IntesisBox. Respect the polarity. Remember the characteristics of the standard EIA485 bus: maximum distance of 1200 meters, maximum 32 device connected, and a 120 ohms terminator resistor in each end of the bus. IntesisBox comes with an internal bus biasing circuit which incorporates internal bus terminator resistor, and thus if you connect IntesisBox in one end of the bus then it is not necessary to install additional 120 ohms resistor in that end. EIA232: Connect the serial EIA232 cable coming from the master device to the EIA232 connector of IntesisBox, this is a male DB9 connector (DTE) in which only lines TX, RX and GND are used, see pinout details in the user's manual. Respect the maximum distance of 15 meters for this EIA232 line. 3. Use the software LinkBoxMB to configure IntesisBox. See the user's manual for details. 3 / 5

Technical characteristics Plastic, type PC (UL 94 V-0). Enclosure Dimensions: 107mm x 105mm x 58mm. Colour Light Grey. RAL 7035. 9 to 30Vdc +/-10%, Max.: 125mA. 24Vac +/-10% 50-60Hz, Max.: 127mA Must use a NEC Class 2 or Limited Source (LPS) and SELV rated power supply. Plug-in terminal block for power connection (2 poles). Terminal wiring (for power supply and low-voltage signals) Mounting ports Modbus TCP port Per terminal: solid wires or stranded wires (twisted or with ferrule) 1 core: 0.5mm 2 2.5mm 2 2 cores: 0.5mm 2 1.5mm 2 3 cores: not permitted Wall. DIN rail EN60715 TH35. 1 x Serial EIA232 (DB9 male DTE). SELV 1 x Serial EIA485 (Plug-in screw terminal block 2 poles). SELV 1 x Ethernet 10Base-T RJ45. 1 x KNX TP1 (EIB) port opto-isolated. Plug-in terminal block (2 KNX port poles). TNV-1 1 x. 2 x KNX port activity (Tx, Rx). LED indicators 2 x Serial port () activity (Tx, Rx). 2 x Ethernet port (Modbus TCP) link and activity (LNK, ACT). 1 x KNX programming/bus. 1 Push buttons 1 x KNX programming. 1 Console port EIA232. DB9 female connector (DCE). SELV Configuration Via console port. 2 Firmware Allows upgrades via console port. Operational 0 C to +70 C temperature Operational 25-90% at 50ºC, non condensing humidity Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). CE conformity to EMC directive (2004/108/EC) and Low-voltage directive (2006/95/EC) Norms and EN 61000-6-2 standards EN 61000-6-3 EN 60950-1 EN 50491-3 1 2 Not operational for the moment. Reserved for future use. Standard cable DB9male-DB9female 1,8 meters long is supplied with the device for connection to a PC COM port for configuring and monitoring the device. The configuration software, compatible with Windows operating systems, is also supplied. 4 / 5

Dimensions External dimensions. + Ethernet port KNX port 58 mm EIA232/485 Console port 107 mm 105 mm Free space recommended to install the device, with spacing enough for external connections. 100 mm 115 mm 130 mm 5 / 5