User Guide. Control Box. RoscoLED TM.

Similar documents
RoscoLED Tape VariWhite Gaffer Kit

LitePad Vector User s Guide

User Guide. X-Effects LED Projector. This guide applies to the following X-Effects models: PLEASE READ & SAVE THESE ORIGINAL INSTRUCTIONS

EPSON PreferredSM Limited Warranty Program for the Epson Stylus

Image Spot. User Guide. This guide applies to the following Rosco Image Spot models: PLEASE READ & SAVE THESE ORIGINAL INSTRUCTIONS

EPSON Preferred. Priority Technical Support. Toll-Free Phone Number. Security and Peace of Mind. On-Site Repair

2 Welcome and Congratulations

EPSON Preferred SM Limited Warranty Program for the Epson Stylus Pro 17-inch Wide Format Printers

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

USER MANUAL. Kramer Electronics, Ltd. Models:

Kramer Electronics, Ltd. USER MANUAL. Model: VM-50AN. 1:5 Audio Distributor

EPSON Preferred Limited Warranty Program for the Epson

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

Lotus DX. sit-stand workstation. assembly and operation instructions. MODEL # s: LOTUS-DX-BLK LOTUS-DX-WHT

user s manual Battery case model #: IPB3500S Battery Case Charger for iphone 6

FastForward TM User Guide

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

EPSON Preferred. Priority Technical Support. Toll-Free Phone Number. On-Site Repair. Security and Peace of Mind

FastForward User Guide

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

MP3 Speaker USER GUIDE

WorkForce 1100 Series. Notices and Warranty

TSD-DA28 2x8 Balanced Line Distribution Amplifier

Chroma-Q Color Web PSU 10-DMX. User Manual

Owner s Instruction Manual

RESIDENTIAL OPERATOR MOTOR CONTROL BOARD REPLACEMENT INSTRUCTIONS

1X2 HDMI Splitter with 3D Support

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

PIM-Mini Pulsed Current Source Operation Manual

Wall. No opening (Example: LA-030-W)

HDMI to 3GSDI Converter

Kramer Electronics, Ltd. USER MANUAL. Model: VM-80HP. 1:8 Stereo Headphone Distributor

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200XLN. XGA Line Amplifier / DA

Support. Phone Number. Technical. Security. On-Site Repair. Peace of Mind. EPSON PreferredSM. Priority. Toll-Free. and

Kramer Electronics, Ltd.

Light as soft as a cloud.

Sonic Ruptor 400. User Manual

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

Kramer Electronics, Ltd. USER MANUAL. Model: VM-4HDCP. 1:4 DVI Distributor

Pulse LED Instruction Guide

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

DVI ELR Extender over one CAT5

TDM-170 TIMER DISPLAY

Kramer Electronics, Ltd.

MFA-0801 & MFA-1201 D-M-E Smart Series Low Voltage Temperature Control System. User s Manual. D-M-E Company

DCM Digital Control Modules

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Page 1 of 6 FXLD1218FRP5I LED FIXTURE Version 0.1 OWNERS MANUAL 08/01/2016

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

MODEL C-HOMWA-1 CONNECTIVITY KIT, CONNEX (USB)

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

VSD-1MC MANUAL 0-10V / 4-20mA Variable Speed Module with Manual Override

Automated Tuner System Power Distribution Hub

Kramer Electronics, Ltd. USER MANUAL. Model: RC-52N. Room Controller

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

Square Sun BI-COLOR SOFT LED FLOOD USER MANUAL

Installation and Operation Guide for PD5200 and PD5300 Automatic Transfer Switch

SATA II HDD Canister KISS DA 435 Quick Reference Guide

Kramer Electronics, Ltd. USER MANUAL. Model: VP-2x2. 2x2 XGA/Audio Matrix Switcher

A double yoke enables it to be operated in several positions. receiving device and then to others in a continuous "daisy chain" fashion.

PSA200 User s Manual

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

HDEXT50M USER MANUAL Extend HD Signals over CAT 5/5e/6 up to 164ft.(50m) All Rights Reserved Version: HDEXT50M_2017V1.2

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Model: RK-1

Three Channel XLR Balanced Patch Bay. Artcessories. User's Manual

INTERPRETER CONTROL UNIT MODEL PL ICU 2 2 (2 INPUTS 2 OUTPUTS) INSTRUCTION MANUAL Technical Data Warranty Information

Hardware Operation Manual for CLE1000 H2K CLE1000 H2V

User's Guide. Model High Precision Quad Output DC Power Supply

TDM-150 TIMER DISPLAY

MPP200 User s Manual

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

Kramer Electronics, Ltd. USER MANUAL. Models: RC-2C, Wall Plate / RS-232 / IR Controller RC-2, Wall Plate / RS-232 Controller

3.5 TFT LCD CCTV Service Viewer with Wristband LCD35SV

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

LED FOLDING WORKLIGHT TM

User Manual. For more information, visit

Dual Link DVI Extender

XC4100 INSTALLATION/OWNER'S MANUAL AM/FM/Cassette Receiver

Resolver to Digital Expansion Board

Kramer Electronics, Ltd. USER MANUAL. Model: WP-210E. XGA Line Driver

Octostrip ORDERCODE 42220

D-Pack 6 Classic ORDERCODE 50315

Owner s Manual. TSD-RL21 2x1 Mic/Line Mixer. TSD-RL21 2x1 Mic/Line Mixer with Remote Level

Atlona 7 PRO HD Monitor with HDMI, VGA and Component Inputs

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

Kramer Electronics, Ltd. USER MANUAL. Model: VM-2HDCP. 1:2 DVI Distributor

OPERATING INSTRUCTIONS

Kramer Electronics, Ltd. USER MANUAL. Model: VA-1DVIN. Virtual EDID

Portable. GL100 An eye on your mobile property. User Guide

DVI ELR Extender over one CAT5

Start Here. All-in-One Printer. Print Copy Scan

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

USER MANUAL. VM-2DP 1:2 DisplayPort Distributor MODEL: P/N: Rev 2

Zonit μats TM Users Guide μats1-lv Version 1.2

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

P O W E R S U P P L Y M A N U A L

Transcription:

RoscoLED TM Control Box User Guide This guide applies to the following RoscoLED Control Box models: RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260 0000) RoscoLED Control Box 400W/VariColor (293 22270 0000)

TABLE OF CONTENTS Introduction... 2 Important Safeguards... 2-4 Unpacking... 5 Control... 6 Operation... 8 Powering On... 8 Dip switch... 8 Test Mode... 10 DMX Operation...11 Connecting RoscoLED Tape...12 Troubleshooting...13 Specifications...14 Warranty... 16 Information and specifications in this document are subject to change without notice. Rosco assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. RoscoLED Control Box User Guide p. 1

INTRODUCTION Congratulations on your purchase of a RoscoLED Control Box. Designed to power and control RoscoLED Tape, the Control Box provides quick and easy set-up with convenient plug-and-play user connections. The RoscoLED Control Box provides a perfect balance of performance, reliability and affordability. To ensure efficient and safe operation, please take a few moments to read this manual completely. IMPORTANT SAFEGUARDS The symbols below are used throughout this manual to identify important safety information. Heed all warnings and safety information. Warning, Danger or Caution. Risk of personal injury. Risk of Electric Shock. Risk of severe electric shock. RoscoLED Control Box User Guide p. 2

PREVENTING ELECTRIC SHOCK This machine uses mains electrical power at 100-240VAC. When directly contacted, such voltages are hazardous to human life. Follow all local electrical codes and take precautions when using this product. This product is designed to operate from three-wire power systems, where one of the wires is a safety ground. DO NOT disconnect the safety ground, or use extension cords or adapter plugs to connect this machine to a two-wire system. Operation without a safety ground may result in hazardous electrical shock. Use only extension cords that are of appropriate length and are rated for Control Box s specified voltage and current. If an extension cord shows signs of wear or gets warm to the touch, discontinue its use and obtain a cord with a higher current rating. Improper extension cords are hazardous and may result in poor performance due to excessive voltage drop. Disconnect unit from power source before servicing and when not in use. RoscoLED Control Box User Guide p. 3

MAINTAINING SAFE OPERATION Use only Rosco spare parts and accessories so as to not void the system warranty. Allow the unit to cool before attempting to service. RoscoLED Control Box must only be serviced by a qualified technician. RoscoLED Control Box is not intended for residential use. Use only in a professional studio or mobile broadcast environment. RoscoLED Control Box is IP20 rated for indoor use only. Do not operate outdoors in a wet environment. RoscoLED Control Box is not certified for use in hazardous locations. RoscoLED Control Box is designed for operation within the range of 32 to 122 F (0 to +50 C). Ensure RoscoLED Control Box is stored within the range of -4 to 140 F (-20 to +60 C). RoscoLED Control Box User Guide p. 4

UNPACKING Carefully remove the unit from the box. Do not attempt to operate RoscoLED Control Box if there are any signs of physical damage. In case of damage, contact your local Rosco dealer. Your RoscoLED Control Box will arrive with a power cord detached from the unit. Plug the Neutrik Powercon into the Power In connector on the Control Panel of the RoscoLED Control Box. Output Panel Note that the holes on the Control Panel, Output and top side of the box should not be covered. This can result in Control Box overheating. RoscoLED Control Box should be mounted onto a flat surface using the side flanges. Control Panel Flanges for mounting RoscoLED Control Box User Guide p. 5

CONTROL RoscoLED Control Box can be operated via the Control Panel. The Control Box offers stand-alone operation, or via user-supplied DMX512 data input. Power and DMX inputs are located on one end of the Control Box. Outputs for the RoscoLED tape are located on the other end of the Control Box. Control Panel Status Indicator Ventilation Holes Dip-Switch Fuse Power In Power Out DMX In (5-pin XLR) DMX In (RJ45) DMX Out (RJ45) RoscoLED Control Box User Guide p. 6

Ventilation Holes Output Connectors RoscoLED Control Box User Guide p. 7

OPERATION Powering On 1. RoscoLED Control Box is supplied with 24VDC switching power supply. A Neutrik PowerCon brings AC power from mains power to the RoscoLED Control Box. a) To supply power to the Control Box, connect a power cord with Neutrik Powercon to the Power In connector on the Control Box. Plug the power cord into AC mains power (100 240 VAC). b) It is possible to pass power through to a series of Control Boxes, using the Power Out connector and appropriate cable. Up to 4 Control Boxes can be connected in series from one AC mains power input. 2. If power is connected properly the Status light should start blinking. The Control Box can now be manually tested. 3. If desired connect the RoscoLED Control Box to a DMX console using either the 5-pin XLR or RJ45 DMX IN ports on the Control Panel. a) For DMX operation, Dip Switch 1 should be at position 1 On. Dip Switches 2 9 should be at position 0 Off. b) If there is DMX signal detected by the Control Box the Status light will start blinking rapidly. RoscoLED Control Box User Guide p. 8

DIP Switch The Dip Switch array is located on the Control Panel end of the Control Box and is used for two purposes: 1. Manual testing the connected RoscoLED Tape 2. Assigning addresses for control by a remote DMX console There are two positions of the 10 DIP switches position 0 or 1, which in turn are Off and On states. When assigning a DMX address, the sum of the numbers on the Dip Switch display expresses the address number. See DMX Operation for additional details. RoscoLED Control Box User Guide p. 9

Test Mode There are several cases when doing a test might be needed. Using the Test Function of the Control Box one can see if everything is connected properly. To enter the FUN mode the FUN switch must be at position 1. Switches 1 6 must be at position 1. Switches 7 9 are used to set the brightness during the test function. RoscoLED Control Box User Guide p. 10

DMX Operation RoscoLED Control Boxes can be operated via DMX512 protocol using the 5-pin XLR or RJ45 DMX IN connectors on the Control Panel. To receive a DMX signal, Dip Switch FUN should be in the Off position. The Status light will blink rapidly when a valid DMX signal is detected. The address of the device is set by combining the values on the different DIP switches. Once the address is set DMX consoles or other DMX512 devices can send signal to the specific address that the Control Box has been set to. RoscoLED Control Box User Guide p. 11

CONNECTING THE ROSCOLED TAPE Before connecting the RoscoLED Tape that is included in this set, the Control Box has to be connected to mains power or to be provided with power from another Control Box. The desired DMX address or testing function must be set. Remove the RoscoLED Tape from its pouch. Connect the Tape to the Control Box via the attached multi-pin connector by rotating the blue release ring counter-clockwise 15 degrees. Insert the connector into a mating output on the Control Box and release blue ring to lock into place. 1 2 3 RoscoLED Control Box User Guide p. 12

TROUBLESHOOTING SYMPTOM POSSIBLE CAUSE SOLUTION When connected to AC Mains power the power indicator light does not illuminate. Fuse is damaged. Power cable is damaged. Check to confirm power cable is properly inserted into Control Box and into AC Mains supply. Check fuse and replace if blown. Status light does not blink rapidly when signal is sent through the DMX IN ports of the unit Check to confirm DMX cable connections are secure. Check DMX address. Bad Cable Check cable. Check DMX output device for valid DMX signal. Follow DIP switch setting for DMX operation. No DMX plugged in Power off at the console. RoscoLED Control Box User Guide p. 13

SPECIFICATIONS Power Input Voltage: Power Supply: Maximum Power Consumption: Physical Characteristics Dimensions: 100 240 VDC Universal 100 240VAC input/12vdc 24VDC output RoscoLED Control Box 300W/Static White (293 22250 0000) RoscoLED Control Box 400W/VariWhite (293 22260 0000) RoscoLED Control Box 400W/VariColor (293 22270 0000) 8.25" 8.25" 2.82" (210 mm 210 mm 72 mm) Weight: (only RoscoLED Control Box) 9.5 lb (4.3 kg) Working Environment Working temperature: Working temperature: 0 C ~ 65 C Working environment: 20 ~ 90% RH non-condensing RoscoLED Control Box User Guide p. 14

Data: DMX 512 5-pin XLR; RJ45 In/Out Approvals: Environmental: CE RoHS Disposal of Old Electrical & Electronic Equipment This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. RoscoLED Control Box User Guide p. 15

3-YEAR LIMITED WARRANTY Rosco Laboratories warrants to the first retail purchaser that this Product will be free from defects in workmanship and material for a period of 36 months from the date of original purchase. For warranty service you must be able to provide proof of purchase. Should this Product prove defective during the warranty period, please contact your local Rosco office for Return Authorization. No warranty service will be performed without Return Authorization. At Rosco s sole discretion, covered Products will be repaired or replaced with new or refurbished equipment or a model of like kind and quality. Exchanged or replaced parts and Products assume the remaining warranty period of the original product covered by this limited warranty. You are responsible for securely packaging the defective Product and returning it to Rosco as per the instructions of the Return Authorization. Within North America, Rosco will ship the repaired or replaced Product to you freight prepaid. Shipments to other locations will be made freight collect. This warranty is non-transferable and does not extend beyond the first retail purchase of the Product. This warranty does not cover damage to the Rosco Product caused by parts not manufactured, distributed or certified by Rosco. Rosco is not obligated to provide warranty service should the Product fail to be properly maintained or fail to function properly as a result of misuse, abuse, improper installation, neglect, improper shipping, damage caused by disasters such as flood, fire and lightning, RoscoLED Control Box User Guide p. 16

improper electrical current or unauthorized service repairs other than those by a Rosco Authorized Servicer. If a claimed defect cannot be identified or reproduced, you will be held responsible for the costs incurred. Unless otherwise stipulated by state law, all warranties expressed or implied are limited to the twelve (12) month period of this warranty. THE WARRANTY AND REMEDY PROVIDED ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY, NON-INFRINGEMENT OR FITNESS FOR A PARTICULAR PURPOSE. EXCEPT AS PROVIDED IN THIS WRITTEN WARRANTY AND UNLESS EXCLUSIONS ARE SPECIFICALLY FORBIDDEN BY STATE LAW, NEITHER ROSCO NOR ITS AFFILIATES WILL BE LIABLE FOR ANY LOSS, INCONVENIENCE, OR DAMAGE, INCLUDING DIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING INJURY TO PERSONS OR PROPERTY, RESULTING FROM THE USE OR INABILITY TO USE THE ROSCO PRODUCT, WHETHER RESULTING FROM BREACH OF WARRANTY OR ANY OTHER LEGAL THEORY. RoscoLED Control Box User Guide p. 17