Upgrading Einstein Using the Einstein 1.5 Upgrade Kit. An EAB board with Production Einstein 1.5 Software EEPROM Chips.

Similar documents
Updating E2 Controller Firmware Using UltraSite32

technical bulletin Updating E2 Controller Firmware Using Ultrasite32

Sound Card Installation for Windows 95/98

USB-Link 2 Technical Guide

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

CRESCENDO /PB G3. Processor Upgrade Card for Macintosh PowerBook 1400 Series Computers. Quick Start Guide for Crescendo/PB G3

2/5/2007 Hints and Tips Support Center Bulletin Revision: 1. Subject: Subject: Echelon Troubleshooting Guide

WVL2 Wireless Vehicle Link 2 Installation and Setup Manual

3. IMPORTANT: When prompted, accept the default Installation directory.

Mac OS 8 Installation Instructions for Sonnet Presto and Presto Plus Processor Upgrade Cards

READ ME FIRST. Windows NT. *DSL Equipment Installation Guide: Efficient Networks 5260

READ ME FIRST Windows 95/98/Me/2000

READ ME FIRST Windows 98/ME/2000

Getting Started. Here's how to get started using your Zip 250 drive: 1. Unpack the Zip 250 drive and accessories.

Sonnet AV/HPV Card Video Adapter Kit

DP SATA 6Gb/s PCIe i/e Quick Installation Guide

Installation Manual Crescendo /L2 Processor Upgrade Cards 2000 Sonnet Technologies, Inc. All rights reserved.

Installation Guide AHA -1530P/1532P. Plug and Play AT-to-SCSI Host Adapter with SCSISelect Utility

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers

Installing Kurzweil K2661 ROM Options

CMOS Passwords and Resources

USB-Link Technical Guide

Owner s s Manual. G5 SATA Double Drive Internal Mounting Kit. Apple Macintosh G5. Add 2 SATA drives to the G5

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

AHA-3980/3980W AHA-3985/3985W

2214 EVENT LOGGER MODULE FOR THE VX2200 SYSTEM

CodeLoader. Users Guide. P/N: Rev: OCT04

TrueNAS Z SERIES NODE SATADOM REPLACEMENT KIT. August 2017 Edition

XEScan Solution Installation Guide 701P38349 April 2002

Dialogic Voice Board & Driver Installation

Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2

Upgrading a 2U CHP to an i7 Quad Core SBC

RK-LINK TM Version 2.x Instructions

Control Techniques Variable-Speed Drive (VSD) Interface to E2 v and Above

ENGLISH. Matrox Parhelia. Matrox Millennium P750. User Guide

Revision: 0.30 June Intel Server Board S1200RP UEFI Development Kit Firmware Installation Guide

2-Port RS232 Serial PCIe with UART Quick Installation Guide

READ ME FIRST Windows 95/98/Me/2000

DP Industrial PCI Serial Adapter Card Quick Installation Guide

USB-Link 2 Technical Guide

INSTALLING THE PS3 XBOX READY SOFTWARE:

Chapter 3 Installation

Service Manual - Memory Upgrade

2-Port Serial 550-Value Quick Installation Guide

SATA 150 Controller PCI Card user

Microprocessor Module Replacement Kit for Multi-Zone Leak Monitors Instruction Manual

DP Industrial PCI Express Serial Adapter Card Quick Installation Guide

A5000 2Mb RAM Upgrade Fitting Instructions

Installing LE History Record Reader program software.

efolder Replibit Pro Appliance Maintenance Manual (Pro 3000, 6000, 9000, and models) Replibit Pro Appliance Maintenance Manual

Revision: 0.30 June Intel Server Board S2600CP4 UEFI Development Kit Firmware Installation Guide

Installing and Removing SDRAM and DRAM

CommLink IV Technical Guide

FSA-CU Configuration Utility Programming Guide

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter

Allen-Bradley Motors

Removing and Replacing Parts

Installing MacBook Pro 15" Unibody Mid 2010 Dual Hard Drive

Dell Inspiron XPS and Inspiron 9100 Service Manual

CyberSerial Dual PCI Quick Installation Guide

Installation Guide AHA-1540CP/1542CP. ISA-to-SCSI Plug and Play High-Performance Bus Master Host Adapter with SCSISelect Utility

Serial ATA PCI RAID Quick Installation Guide

Firmware, Database, & PC Application Update Installation Instructions

Upgrading the MSA1000 for Enhanced Features

ROCKET NVMe PCIe M SSD

Rev Cutler-Hammer Smart Breaker Panel Control Manual

INSTALLATION AND STARTUP

Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

Peerless Drive System User's Manual

Dell XPS 14z Owner s Manual

COMPUTER PROCESS CONTROLS

Cyber 2S1P 950 PCI Quick Installation Guide

BCOM-USB Device. User Manual.

CyberSerial 4S PCI Quick Installation Guide

Bellatrix Systems, Inc. Maintenance Test Station For Windows XP Version 1.0. User Manual

Addendum for Tempo HD (Without Drive)

DP 1-Port ECP/EPP Parallel PCIe Quick Installation Guide

Firmware, Database, & PC Application Update Installation Instructions

This section describes how to install the following options: #!! #!% *+! Use Figure 8-1 to locate the system board features.

Pentium Third Serial Port Installation

Installing TEAC CD-ROM Drives

Windows Me Plug-and-Play

INSTALLATION AND OPERATION MANUAL FOR ACC 070 COMM LINK RS485 TO PC INTERFACE AND PRISM SOFTWARE

User s Manual USB 3.0 Expansion Card TS-PDU3

USB-Link 2 Technical Guide. USB-Link 2 Code: SS0073 Version 4.11 and up

MPA FLASH PROGRAMMING

Digital Media Player Installation Instructions

Power Xpert Meter 2000 Gateway Card Kit

CAP 505 Relay Product Engineering Tools Installation and Commissioning Guide

635-FTS Factory Programming Guide

Upgrade Instructions. View Manager 96 v Software Upgrade. The system displays the following prompt:

5x86 Third Serial Port Installation

Intellex Digital Video Management System. Installing a CD-RW in Intellex

2009 Davis Instruments Corp. All rights reserved. Information in this document is subject to change without notice.

PXI The PXI-8210 is a Fast Ethernet/Ultra Wide SCSI interface for the PXI/CompactPCI bus.

Installation Guide AMM-1525M/1510M/525M. SCSI Audio Host Adapters and Sound Cards

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

update advisory Advisory for Installers of E and UltraSite and Above

Transcription:

TECHNICAL BULLETIN Upgrading Einstein Using the Einstein 1.5 Upgrade Kit This bulletin explains how to use the components of the CPC Upgrade Kit to upgrade a pre-1.5 version Einstein unit to the latest Einstein release (1.5). Components of the Upgrade Kit The CPC Upgrade Kit contains the following components: An EAB board with Production Einstein 1.5 Software EEPROM Chips. The correct version of Boot\BIOS and Manufacturing Loader ROM Chips. The production UltraSite32 release CD. A direct connect cable for making the computer-to-einstein connection. Instructions for performing the Legacy to Einstein 1.5 Upgrade (this document) Checklist to be used during the upgrade. Before You Begin Install or Upgrade UltraSite32 The Einstein EAB upgrade process requires that you have a laptop or desktop PC with the latest version of UltraSite32 installed. Use the UltraSite32 CD and the instructions supplied with the kit to install or upgrade to your PC. Set Up Site Communications With UltraSite32 If you don t already have UltraSite32 set up to communicate with the site controllers, you will need to set up the site in UltraSite32. 1. Using the supplied direct connection cable, connect the 9-pin male end to the serial port on the left-hand side of the Einstein box. Connect the other end to a serial port on your laptop or desktop PC. 2. Follow the instructions in the UltraSite32 User s Guide for creating a directory and creating a site. In the site communications box, set the Device type to Einstein and the Connection type to Direct Connect. In the Modem/Direct Settings box, set the Baud Rate to 9600, and from the Port pull-down menu, choose the COM port to which the direct connect cable is attached. (See Figure 1). COMPUTER PROCESS CONTROLS - http://www.cpcus.com/ Page 1

Figure 1 - Site Communications Dialog Box 3. Right-click the site name in the UltraSite32 Tree View, and select Connect from the Action Menu. Allow UltraSite32 to perform a site synchronization with the site controllers (this might take a few minutes). Prepare Upgrade Checklist(s) An Einstein EAB upgrade checklist form has been included in the upgrade kit. Make a photocopy of this checklist for each Einstein you will be upgrading. Fill out each checklist with the make (RX or BX), model (300, 400, or 500), subnet number, unit name, name of person upgrading, and the date of upgrade. Use this checklist during the Einstein upgrade process to make sure no necessary steps are skipped. After completing a step, put a check in the box and move on to the next step. Write any comments or descriptions of issues encountered in the Comments section of the checklist. Upgrading Einstein Using a Loaded EAB After doing all the steps in the Before You Begin section of this document, you are ready to begin the Einstein upgrade process. Step 1: Back up the unit using UltraSite32 This step is VERY IMPORTANT. Backing up your unit configuration in UltraSite32 saves a copy of the set points that will be restored to the Einstein later in the process. 1. In UltraSite32, locate the name of unit you are backing up in the Tree View. Right-click the name when you find it. 2. From the Action Menu that appears, select Backup. Wait for the backup to finish before proceeding to Step 2. COMPUTER PROCESS CONTROLS - http://www.cpcus.com/ Page 2

Step 2: Disconnect from the site in UltraSite32 Right-click the site from the Tree View, and select Disconnect from the Action Menu. Step 3: Open the Einstein enclosure Use a screwdriver to unlatch the Einstein s door and carefully open the door. Step 4: Remove the metal shield from the doorplate There should be a metal shield protecting the processor board on the doorplate. Remove the two screws that attach the shield to the doorplate, and remove the metal shield to expose the processor board. Step 5: Disconnect power to the Einstein On the Einstein processor board, locate the 24VAC power connection, located at the top right corner of the board. Unplug the power connector from the processor board to power down the Einstein. Step 6: Remove all Echelon and RS485 Network connections and wait 60 seconds Unplug all Echelon and RS485 wires from their respective ports on the motherboard. After doing this, wait 60 seconds to allow the Einstein board to completely reset. Step 7: Plug the EAB board into the EAB slot on the processor board The EAB slot on the Einstein processor board is a 50-pin (25x2) port located on the upper left corner of the Einstein processor board (see Figure 2). Carefully plug the EAB board into the EAB slot, with the chips on the board facing away from the processor board. Make sure all pins are correctly aligned with the port on the EAB board before applying pressure, or else one or more pins might bend or break. COMPUTER PROCESS CONTROLS - http://www.cpcus.com/ Page 3

Figure 2 - Plugging the EAB Board into the EAB Slot Step 8: Reconnect power to the Einstein and allow upgrade to occur Plug the power connector back into the Einstein processor board. Einstein will automatically detect the EAB board and initiate upgrade. If the screen remains blank after powering up the Einstein, or if Einstein boots as normal without detecting the EAB, check to make sure the EAB is seated firmly on the EAB slot pins AND that all pins are seated in the EAB port with no overlapping. When the screen says LOADED, the upgrade is complete. Proceed to Step 9. Step 9: Disconnect power to the Einstein Unplug the power connector from the processor board to power down the Einstein. Step 10: Remove the EAB from the processor board and wait 60 seconds Carefully remove the EAB from the processor board, being careful not to bend or break any pins. Allow the Einstein motherboard to sit untouched for 60 seconds to allow the board to completely reset. Step 11: Reconnect power to the Einstein and allow Einstein to boot Plug the power connector back into the Einstein processor board. Allow the Einstein to boot completely. When finished, the Main Status Screen should appear. COMPUTER PROCESS CONTROLS - http://www.cpcus.com/ Page 4

In some rare cases, Einstein might notify you that Flash 1 must be formatted. If you get this message, press Y followed by ENTER to begin the reformatting process. When finished, the Einstein will boot up and the Main Status Screen should appear. Step 12: Replace the Echelon and RS485 Network Connections Plug the Echelon and RS485 wires back into their respective slots on the motherboard. Step 13: Replace the metal shield on the doorplate Put the protective metal shield back on the rear face of the Einstein doorplate. Reattach it to the processor board using the two mounting screws. Step 14: Run a clean-out procedure on the Einstein After changing the model type, it is a good idea to perform a clean out to remove any excess configuration from the old model type. Open your Einstein unit and locate the three buttons below the Echelon connection slots on your Einstein processor board (see illustration at right). The bottom two of these buttons are the CLEAN OUT button and the RESET button. You will need to use both of these buttons to clean out the unit. 1.Press and hold down both the Reset Button and the Clean Out button. 2.When the screen clears, release the Reset Button, but CONTINUE TO HOLD DOWN THE CLEAN OUT BUTTON. 3.When the screen displays the message Resetting to clean out configuration, release the Clean Out button. Step 15: Restore configuration to Einstein from UltraSite32 To restore set points to an Einstein unit after an upgrade and clean out: 1. Before restoring, you must run a site synchronization in UltraSite32 to update the database with the new revision information. If you are already connected to the site, right-click the site in the Tree View, and select Site Synchronization. If you are not already connected to the site to which the Einstein belongs, right-click the site on the Tree View and select Connect from the action menu. Connecting to the site will automatically run a site synchronization. COMPUTER PROCESS CONTROLS - http://www.cpcus.com/ Page 5

2. Verify that UltraSite32 has updated revision information for each controller you have upgraded. To do this, right-click each unit you have upgraded, and select Information from the action menu. This action will show you a dialog box, which contains the firmware revision number UltraSite32 received during the last site synchronization. If this revision number does not match the version you upgraded the Einstein to, wait 10 minutes and repeat the site synchronization process. Also, verify no one is logged in to any of the Einsteins front panels during site synchronization. 3. In the UltraSite Tree View, right-click the unit you wish to restore set points to, and select Restore from the menu. 4. Wait until UltraSite32 tells you the restore was successful. Then, click OK. Step 16: Close the Einstein enclosure door Carefully close the Einstein enclosure door and latch it using a screwdriver. Step 17: Restore communications with Echelon peripherals Skip this step if Einsteins are the only devices on your Echelon network. If your Einstein RX or BX unit has any connected CC-100s, RT-100s, TD3s, ESRs, or any other kind of Echelon peripheral, a unit upgrade will cause these devices to lose connection with the Einstein. In order to get Einstein and the peripherals to communicate again, you must follow the procedure below to recommission each Echelon peripheral in the Einstein s subnet. You may perform the procedure below at any time after restoring set points to the newly upgraded Einstein. 1. Log in to the Einstein you just upgraded. 2. Access the Controller Network Configuration screen by pressing the following key sequence: F8, Y, 4, 1. This screen should list all the Einstein s Echelon and I/O devices. Echelon devices are marked with a LON in the Bus field, and should also have a 12-digit number in their Neuron ID fields. 3. Move the cursor to highlight the next Echelon device in the table that is NOT the first entry. The first entry in the table is the Einstein you are logged in to, which does not require commissioning. 4. Press F6: SET ADDRESS. 5. When Einstein prompts for the method you wish to use to set the Neuron ID address, select 2 = Entering Neuron ID from label on controller. 6. Einstein will ask you to specify the Neuron ID of the selected controller. The default value is the Neuron ID number it backed up and restored to the Einstein after the upgrade. Press F1 to use this number. 7. Repeat steps 3 through 6 above for every Echelon device listed on the screen. 8. When finished, press F10 - BACK to return to the Network Setup/Status Menu screen. Einstein will now begin communicating with the Echelon peripherals. This completes the Einstein upgrade process. Repeat these instructions for each Einstein you wish to upgrade. COMPUTER PROCESS CONTROLS - http://www.cpcus.com/ Page 6

Troubleshooting PROBLEM: One or more Echelon devices are not communicating with their parent Einstein, even after recommissioning. The Controller Network Status screen says the device is on-line, but no data flow is occurring. When a unit is upgraded and cleaned out, Einstein thinks it is still communicating with its Echelon peripherals, even though it isn t. As a result, the Controller Network Status screen will falsely show all these devices as on-line. Recommissioning will repair the communication links between Einstein and the Echelon peripherals. If only one or two devices are not communicating after the recommission process, it is likely you accidentally skipped recommissioning these devices in the Controller Network Configuration screen. Follow the procedure listed in Step 17 for each device that is not communicating. If the problem continues, notify CPC. If a large number of devices are not communicating after recommissioning, there may be a problem with the Echelon network. Check the Echelon wire connections to the Einstein processor board to make sure they are secure. Also, you may have pressed F5 - CANCEL instead of F10 - BACK after recommissioning all the boards, which would have exited the screen without saving your changes. Try to recommission the boards again. If the problem continues, notify CPC. PROBLEM: While restoring configuration to an Einstein, UltraSite32 crashes when trying to restore User Status Group applications. There is a known issue with User Status Group applications in Einstein that causes an error in the restore process. All User Status Groups must be removed from the Einstein configuration to make the restore process function correctly. If you have backed up the unit s configuration in UltraSite32, you may remove User Status Groups using Offline Programming. 1. In UltraSite32, right-click the Einstein you wish to edit, and select Offline Programming from the action menu. 2. Locate the User Status Group item on the Offline Programming Tree View. Click on the + sign next to User Status Group to display a list of all User Status Group applications configured for this Einstein. 3. If you wish to get a hard copy of configuration information for each status group so you can easily reprogram them after restore, right-click the name of the User Status Group application and select Edit Application from the action menu. You may print each User Status Group s configuration one page at a time by navigating to each screen and clicking the Print icon in the UltraSite32 toolbar. 4. To delete a User Status Group application, right-click on its name in the Offline Programming Tree View, and select Delete Application from the action menu. After configuration is restored to the target Einstein, you may readd User Status Groups from the Einstein front panel. COMPUTER PROCESS CONTROLS - http://www.cpcus.com/ Page 7

Service Checklist: Upgrading to Einstein 1.5 Using a Loaded EAB Model: Einstein [X RX X BX] [X 300 X 400 X 500] Subnet: Unit Name: Technician s Name: Site: Site Phone #: Date of Upgrade: / / Version # of unit before upgrade:_. Refer to 026-4100-001, Upgrading Einstein Using the Einstein 1.5 Upgrade Kit, for specific instructions. Use this checklist to verify all steps in the upgrade process have been performed. After completing a step, check the box. X Step 1: Backup the unit using UltraSite32. X Step 2: Disconnect from the site in UltraSite32. X Step 3: Open the Einstein enclosure. X Step 4: Remove the metal shield from the doorplate. X Step 5: Disconnect power to the Einstein. X Step 6: Remove all Echelon and RS485 Network connections and wait 60 seconds. X Step 6a: Hold down the SHIFT and F1 keys, and reconnect power to the Einstein. Step 6b: Select Advanced CMOS Configuration. Step 6c: Change Boot Sequence field to Mini-DOS. Step 6d: Press Undo to return to the System BIOS screen. Step 6e: Select Write to CMOS and Exit and press Enter. X Step 6f: Disconnect power from the Einstein and wait 60 seconds. NOTE: Steps 6a-6f are only necessary if upgrading from a 1.50 beta version (1.50Bxx) to 1.50F01. See Technical Bulletin P/N 026-4101 for more information. FAX: (770) X Step 7: Plug the EAB board into the EAB slot on the processor board. X Step 8: Reconnect power to the Einstein and allow upgrade to occur. X Step 9: Disconnect power to the Einstein. X Step 10: Remove the EAB from the Einstein s EAB slot and wait 60 seconds. X Step 11: Reconnect power to the Einstein and allow Einstein to boot. X Step 12: Replace the Echelon and RS485 Network connections. X Step 13: Replace the metal shield on the doorplate. X Step 14: Run a clean-out procedure on the Einstein. X Step 15: Restore the set points to the Einstein using UltraSite32. X Step 16: Close the Einstein enclosure door. X Step 17: Restore communications with Echelon peripherals. X Check here if all steps have been completed and the Einstein has been upgraded successfully. Signature: Date: Comments: After completion, please send to: Computer Process Controls c/o Service Department 1640 Airport Road Suite 104 Kennesaw, GA 30144 425-9319