IMPORTANT! GE Caddx panels cannot support PIN codes then end in zero over RS-232. See Common Mistakes for more information.

Similar documents
Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Power Series / 5401

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): MAXSYS Series

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Gemini P9600

The Texecom Premier Elite security panels integrate with the g! system using either an Ethernet connection or an RS-232 serial connection.

Model Number(s): D7000, D9000 Series Panels, D7000/9000V2 Panels

Integration Note OVERVIEW AND SUPPORTED FEATURES INSTALLATION OVERVIEW. Model Number(s): V883, V85

Integration Note OVERVIEW AND SUPPORTED FEATURES. Model Number(s): SR5008/6008/7008

Integra DTR-20.7/30.7/40.7/50.7/60.7/DHC-60.7 Onkyo TX-NR545/646TX-RZ800/900

VSX-60, SC-61, SC-63, SC-65, SC-67, SC-68

Integration Note OVERVIEW AND SUPPORTED FEATURES. Model Number(s): SR6006, SR5006

Core Module Version: Comments: Firmware: Release 4.15, Prom v1.70g, DSP Document Revision Date: 1/10/2013

Integration Note OVERVIEW AND SUPPORTED FEATURES THE FOLLOWING FEATURES ARE SUPPORTED: THE FOLLOWING FEATURES ARE NOT SUPPORTED:

R2D7 Serial Interface for RP60 motor

Integration Note OVERVIEW AND SUPPORTED FEATURES

4.0 Build or newer

Software 4.0 Build Rel or later. Nuvo Grand Concerto FW v2.56, HWv00; M3 Server v1.60, ipod v1.53 Document Revision Date: 1/17/2013

A suggested source is Opternus:

Integration Note OVERVIEW AND SUPPORTED FEATURES. Minimum Core Module Version: Document Revision Date: 09/25/2017

Lighting Integration Note

Integration Note OVERVIEW AND SUPPORTED FEATURES LUTRON LIGHTING SYSTEMS SUPPORT THE FOLLOWING FEATURES:

Model Number(s): WPS-300-DVR-9CH, WPS-300-DVR -16CH

Integration Note OVERVIEW AND SUPPORTED FEATURES. Model Number(s): (Various)

Minimum Core Module Version: g! version 5.4, requires S1616A Firmware Document Revision Date:

Live or Recorded Video: Video output from the NVR is not available in the ELAN Viewer.

Audio Integration Note

Minimum Core Module Versions: ELAN version 7.1 ( for streaming audio) MRA Software or above Document Revision Date: 6/9/2017

Furman F1000, F1500 Panamax M4320, MB1000, MB1500

Audio Integration Note

Lighting Integration Note

Audio Integration Note

Model Number(s): Mirage Media Server (Autonomic MMS-x Devices)

Integration Note. Any feature not specifically noted as supported should be assumed to be unsupported.

Audio Integration Note

Integration Note OVERVIEW AND SUPPORTED FEATURES

SRC, SRC Plus, Pro-C, ICC, X-CORE, I-CORE

Any feature not specifically noted as supported is not supported.

Extender Controller Integration Note

THIS SONOS CONNECT AMP DRIVER SUPPORTS THE FOLLOWING FEATURES: Any feature not specifically noted as supported is not supported.

FSA-CU Configuration Utility Programming Guide

Integration Note. mhub4k431, mhub4k862, mhub4k44pro & mhub4k88pro

Integration Note. Any feature not specifically noted as supported should be assumed to be unsupported.

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES

Integration Note. Any feature not specifically noted as supported should be assumed to be unsupported.

NX1700EIB02 (Supercedes NX1700EIA02) NetworX Series. NX-1700E Proximity Card Reader Installation and Startup

Integration Note. Any feature not specifically noted as supported should be assumed to be unsupported.

Integration Note. Virtual Matrix: The driver offers the ability to receive the auxiliary input feed from up to three other Sonos units

INSTALLATION MANUAL. Table of Contents. General Description Position Dip Switch Settings Enrolling the NX216-E Expander...

Integration Note. Any feature not specifically noted as supported should be assumed to be unsupported.

THIS NIKO HOME CONTROL DRIVER SUPPORTS THE FOLLOWING FEATURES: Any feature not specifically noted as supported is not supported.

Mirage Media Server (Autonomic MMS-x Devices)

Holovision units with VIK(sip) Intercom Modules. Firmware v 2.9 setup v For firmware v 1.09, please see Appendix 1

Camera Firmware or (5.50 fixes security vulnerability introduced in 5.20) Document Revision Date: 07/15/2016

Configuring Honeywell Vista Alarm Panels Using the HSIM Interface Module Integration Release Notes

LANCNC FTP Data Server for CNC Controls Machine Mount instructions

NetworX Series NX-216 Zone Expander Installation and Startup

Keypad LCD (software version 3.10) CA-10 plus

SOFTWARE VERSION 3.20

Integration Note. Overview & Supported Features THE FOLLOWING OPTIONS ARE SUPPORTED BY THIS DRIVER: NOT RECOMMENDED

Metasys Integrator Northern Application

Integration Note. Virtual Matrix: The driver offers the ability to receive the auxiliary input feed from up to six other Sonos units

Integration Note. Any feature not specifically noted as supported should be assumed to be unsupported.

XPress DR+W Quick Start Guide

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

Code Dynamics, Inc. Port Splitter

NetworX Series. NX-507E RELAY EXPANDER NX-508E OUTPUT EXPANDER Installation and Startup

Audio Servers S1, H1, H3, H5CD and Others

Integration Note OVERVIEW AND SUPPORTED FEATURES. IP Video Cameras (See models list below) NOTE: Only Panasonic Petcams, Residential cams, and

FieldServer Driver - Serial FS Fire Control Instruments - FCI 7100 Series

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

PROGRAMMING AND INSTALLATION MANUAL

USB/RS232 TO cctalk COMMUNICATION BOARD Technical Information

Keypad LCD-L (software version 3.10) CA-10 plus

NetworX Series NX-1710E Single Door Control. Installation and Startup Manual

BioPointe Reader Installation Guide

TouchOne Mini User s Guide

NOTE: This integration applies only to the Bentel Access Control Panel/Keypad equipment with firmware version 3.50 or later.

Operating Manual. 3000E NTCIP Translator Card for IQ Central. p/n Rev 3. IQ Connect for 3000E Operating Manual

Serial Interface Module

NX-2192E PINPOINT SYSTEM

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM

Installation Guide of Hi-Speed USB Industrial I/O Adapter

Installation Instructions

Canlan INSTALLATION MANUAL

Installation Instructions. Ecast View B75B Motherboard Upgrade Kit Kit #

DSC MAXSYS INTEGRATION THROUGH A KT-400 CONTROLLER

CodeLoader. Users Guide. P/N: Rev: OCT04

Product Manual. USB 2.0 to Serial High- Speed RS-232 Industrial Adapter. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-COM-M

SOFTWARE VERSION 3.10

Installation and Programming Manual. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

Minimum Core Module Version: 4.0 Build 1452 Comments: AXIS IP Utility , Camera Firmware 4.40 Document Revision Date: 2/13/2013

PFCS/Qualifier Interface

Exede Enterprise 75cm Auto Acquire Antenna

4XLFN6WDUW*XLGH. LYNXR is not intended for UL985 Household Fire applications.

ELK-M1XSP Serial Port Expander

Flex Control Network. Model No. DC20/ DC21 DEVICE CONTROLLER. Rev 2 Hardware

Quick Start Guide. 2-Port 10/100 Device Server RS-232/422/485 DB9 M. Access two serial RS-232 or RS-422/485 devices over a 10- or 100-Mbps network.

Series. NX-8-EUR Control Panel. Installation manual

4-port USB to RS232 Adapter FTDI Cable. Product Manual. Coolgear, Inc. Version 1.1 September 2017 Model Number: CG-4X232FTDI.

Using the Extron CTL208 with SoundStructure

Transcription:

Manufacturer: GE NetworX Integration Note Model Number(s): NX-4,6,8 Core Module Version: Document Revision Date: 01/09/2016 OVERVIEW AND SUPPORTED FEATURES The NetworX NX-4,6,8 security panels integrate with the g! system using an RS-232 serial connection. The panels require the NX-584 Home Automation Module to enable RS-232 communications between the controller and the control panel. THESE PANELS SUPPORT THE FOLLOWING FEATURES: Arm Disarm: Arm and disarm from the Viewer interface is supported for any partition. Status information is available for all partitions. Auto Arm: Arming as a System Command from the Event Mapper is supported for any partition. By default, automatic arming is disabled in the Configurator. Zone Status: Zone status information for all zones is properly shown in the Viewer. History View: The history view is properly supported on any Viewer. Bypassable Zones: You can bypass a zone in the Viewer interface. In Version 4.0 Build 346 and later, bypassable zones are auto-detected. In earlier version, enable bypass for each zone in the Configurator. For correct bypass operation, the panel and g! should both be set to the same bypass option. Discrepancies between the panel s bypass setting and g! s bypass setting can cause unpredictable results. Auto Zone and Partition Detection: After a zone has been faulted the g! system will automatically detect the zone number and partition number but not the name. IMPORTANT! GE Caddx panels cannot support PIN codes then end in zero over RS-232. See Common Mistakes for more information. THESE PANELS DO NOT SUPPORT THE FOLLOWING FEATURES: Any feature not specifically noted as supported should be assumed to be unsupported. INSTALLATION OVEVIEW 1. Install the security system and program the panel for the RS-232 interface. 2. Run a Cat5 wire from the g! system to the security panel and test the cable. 3. Test the security panel, zone sensors and keypads for functionality. 4. Connect the g! system to the panel electrically. ELAN Home Systems 1690 Corporate Circle Petaluma, CA 94954 USA tech support: 800.622.3526 main: 760.710.0990 sales: 877.289.3526 email: elan@elanhomesystems.com 2013 ELAN Home Systems. All rights reserved. ELAN and g! are trademarks of ELAN Home Systems. All other trademarks are the property of their respective owners.

5. Configure the controller communication device and security panel and confirm communication between the panel and the controller. 6. Fault all the zones in the system. Faulting the zone sends a message to the g! system which then automatically adds the zone in the Configurator. Zones that can t be easily faulted must be added by hand. Confirm that all zones are visible in the Configurator, and then provide names for each zone and partition with the Configurator 7. Test the arming and disarming capability from a computer or touch screen and confirm history function. DIAGRAM 1: NX-584 HOME AUTOMATION JUMPER SETTINGS AND WIRING DIAGRAM The following diagram shows the jumpers and how to wire the NX-584 to the panel. The jumper settings and wiring is the same for Option 1, Option 2 and Option 3. See note below for NX4,6,8 V2 panels. IMPORTANT NOTE for NX V2 series panels: remove jumper J7 on the NX-584 board to allow proper communication between the panel and the system controller. NX-584 NX 4,6,8 TERMINAL BOARD J9 J7 J10 J8 Data Keypad Com Keypad Pos Keypad Pos Keypad Com Keypad Data Keypad 2 of 8

CONNECTION METHODS OPTION 1: CONNECT TO A SERIAL PORT ON THE SYSTEM CONTROLLER See Diagram 1 for jumper settings DB9F to RJ-45 Null Adapter 3 2 NX-584 1 Control Panel 5 g! System Controller 4 Cat5 Cable Assy. BILL OF MATERIALS FOR OPTION 1 # Device M anufacturer P art Number P rotocol Connector Type Notes 1 Control Panel GE NetworX NX-4,6,8 RS-232 Various 2 Home Automation Module GE NetworX NX-584 RS-232 DB-9 Male See Diagram 1 for jumber settings 3 DB9F to RJ45 Null Adapter ELAN HA-CB-328 RS-232 DB-9 Female X RJ-45 Female 4 Cat5 Cable Installer N/A RS-232 RJ-45 Male X RJ-45 Male Must terminate all 8 conductors 5 g! System Controller ELAN Various (e.g. HC12) RS-232 RJ-45 Female 3 of 8

OPTION 2: CONNECT TO THE ETHERNET NETWORK WITH A SERIALBRICK See Diagram 1 for jumper settings Cable provided with Network Assy. 6 Cat5 Cable Assy. DB9F to RJ-45 Null Adapter 3 2 NX-584 1 Control Panel Any Ethernet LAN Port 7 Network Assembly 8 g! System Controller 4 RS232 ETHERNET 5 SerialBrick BILL OF MATERIALS FOR OPTION 2 # Device M anufacturer P art Number P rotocol Connector Type Notes 1 Control Panel GE NetworX NX-4,6,8 RS-232 Various 2 Home Automation Module GE NetworX NX-584 RS-232 DB-9 Male See Diagram 1 for jumber settings 3 DB9F to RJ45 Null Adapter ELAN HA-CB-328 RS-232 DB-9 Female X RJ-45 Female 4 Cat5 Cable Installer N/A RS-232 RJ-45 Male X RJ-45 Male Must terminate all 8 conductors 5 SerialBrick ELAN HW-EB-100 RS-232 X IP RJ-45 Female X RJ-45 Female 6 Cat5 Cable Installer N/A IP RJ-45 Male X RJ-45 Male 7 Network Assembly ELAN NWA18 IP RJ-45 Female X RJ-45 Female 8 g! System Controller ELAN Various (e.g. HC12) IP RJ-45 Female 4 of 8

PANEL PROGRAMMING You must first install the NX-584 and enroll it in the panel. This process is described in the NX-584 documentation; please refer to Diagram 1 for the proper wiring and jumper settings. Once the NX-4,6,8 is running properly, you need to make a few changes to the settings to integrate with the g! system system. The following steps assume you have the LCD keypad. If not, refer to the NetworX documentation to understand how the values are displayed on the LED keypad. For clarity, the following instructions use [ ] brackets around keys that you press and also around settings shown on the keypad. IMPORTANT NOTE: If the segment values listed in the table below (such as [1 2 - - - - - -]) are incorrect, the value can be changed by pushing the corresponding number on the keypad. For example: [- 2 - - - - - -] can be changed to [- - - - - - - -] by pressing the #2 button, and [- - - - - - - -] can be changed to [- - 3 - - - - -] by pressing the #3 button. Step Instructions Comments 1 Press [* 8] + [9713]+[72]+[#] Enter programming mode for the NX-584, module 72, using the factory default password 2 Press [0 #] Sets the location to 0. Change the value to [- - - - - - - - ], enabling the Home Automation Protocol 3 Press [*] Stores the data into location 0 4 Press [1 #] Sets the location to 1. Confirm the value is 4, enabling the Baud rate of 9600 5 Press [*] Stores the data into location 1 6 Press [2 #] Sets the location to 2 segment 1. Confirm that the value is set to [- 2 - - - - 7 -], enabling Interface Configuration at Power Up and Partition Status Message 7 Press [*] Sets the location to 2 segment 2. Confirm that the value is set to [1 2 - - - - - -], enabling System Status Message and X10 Message Received 8 Press [*] Stores the data into location 2 segment 2 9 Press [3 #] Sets the location to 3 segment 1. Confirm that the value is set to [- 2-4 5 6 7 8], enabling Interface Configuration Request, Zone Name Request, Zone Status Request, Zones Snapshot Request, Partition Status Request, Partitions Snapshot Request 10 Press [*] Sets the location to 3 segment 2. Change the value to [1 2 3 4 5 - - - ], enabling System Status Request, Send X- 10 Message, Log Event Request, Send Keypad Text Message, Keypad Terminal Mode Request 5 of 8

Step Instructions Comments 11 Press [*] Sets the location to 3 segment 3. Change the value to [1 2 3-5 - 7 -], enabling Program Data Request, Program Data Command, User Information Request with PIN, Set User Code Command with PIN, Set User Authorization Command with Pin 12 Press [*] Sets the location to 3 segment 4. Change the value to [- - - 4 5-7 8], enabling Set Clock/Calender Command, Primary Keypad Function with Pin, Secondary Keypad Function, Zone Bypass Toggle 13 Press[*] Stores the data into location 3 segment 4 14 Press [4 #] Sets the location to 4 segment 1. Confirm the value is 192, setting the LCD Keypad Address to 192 15 Press[*] Stores the data into location 4 16 Press[Exit] Exits device setup 17 Press[Exit] Exits device setup 6 of 8

g! CONFIGURATION DETAILS The following table provides settings used in the g! Configurator when connecting to the NetworX control panel. Please refer to the Configurator Reference Guide for more details. In the table below: o <Select> Select the appropriate item from the list (or drop-down) in the Configurator. o <User Defined>, etc. Type in the desired name for the item. o <Auto Detect>, etc. The system will auto detect this variable. o <Defined in Security System> The security installer must provide the information to you. Devices Variable Name Option 1 Option 2 Option 3 Communication Devices Name <User Defined> (Default: Security) <User Defined> (Default: Security) <Auto-Detect> (See Note 1) Type Serial Port Serial Port (IP to Serial) SerialBrick SerialBrick Name N/A N/A <Select from list> Communication Type Standard Connection Standard Connection Standard Connection Location <User Defined> (Not Required) <User Defined> (Not Required) <User Defined> (Not Required) Com Port <Select> <Select> <Select> Security Panels Name <User Defined> (Default: GE NetworX NX-4,6,8,8E) <User Defined> (Default: GE NetworX NX-4,6,8,8E) <User Defined> (Default: GE NetworX NX-4,6,8,8E) Device Type GE NetworX NX-4,6,8,8E GE NetworX NX-4,6,8,8E GE NetworX NX-4,6,8,8E Location <User Defined> (Not Required) <User Defined> (Not Required) <User Defined> (Not Required) Comm Device <Select> (Default: Security) <Select> (Default: Security) <Select Auto Detect SerialBrick name above> Name Show Auto Keys Name Show Auto Keys Name Show Auto Keys Disarm Disarm Yes NO 4 Disarm Yes NO 4 Disarm Yes NO 4 Mode 1 Stay Yes NO 4 Stay Yes NO 4 Stay Yes NO 4 Mode 2 Away Yes NO 4 Away Yes NO 4 Away Yes NO 4 Partions Name <User Defined> <User Defined> <User Defined> User Number N/A N/A N/A Show Partition Yes Yes Yes Areas in Partition <User Defined> (Not Required) <User Defined> (Not Required) <User Defined> (Not Required) Zones Name <User Defined> <User Defined> <User Defined> Enable Bypass <Defined in Security System> (See Note 2) <Defined in Security System> (See Note 2) <Defined in Security System> (See Note 2) Notes: 1. The Communication Devices Name is set to Security by default. After you select the SerialBrick, the name will change to that specified by the SerialBrick. 2. The Enable Bypass variable must set to Yes in order to enable this feature for a zone. The zone must also be bypassable in the security panel for this feature to function. 7 of 8

COMMON MISTAKES 1. Failing to test the Cat5 cable assembly. It is easy to make a mistake when terminating the Cat5 cable with the RJ-45 connectors. Always use a LAN tester to check for continuity and shorts. 2. Using a Cat5 patch cable without all 8 conductors. Some Ethernet patch cables only have the 4 conductors (1,2,3,6) needed for Ethernet communications. These cables will not work as patch cables for RS-232 communications. Visually inspect the clear plastic connectors to determine if all 8 wires are present. 3. Failing to set the jumpers on the NX-584 correctly. Refer to diagram 1 for the correct settings. Incorrect jumper settings will cause communication problems with the system controller. 4. Failing to remove jumper J7 for NX4,6,8 V2 series panels. With J7 in place the panel will not communicate with the system controller. 5. Using the incorrect ELAN DB-9 to RJ-45 adapter to connect to the security panel hardware. Use the HA-CB-328, which provides the required NULL modem conversion. Use the HA-CB-308 to connect the Cat5 to the g! system (Option 1 only). 6. Failing to plug the Cat5 cable assembly into the correct port. Make sure the RJ-45 connector is plugged into the same port (COM1, 2, 3 or 4) that is specified in the Configurator. 7. Failing to plug the Network Assembly serial cables and USB cables into the correct ports on the g! system. Check that the COM port printed on the grey ribbon cables (COM1 and COM2) as well as the USB cables (COM3 and COM4) match the port numbers as printed on the g! system label. 8. Using PIN Codes that end in zero. Due to the way the GE control protocol functions, zeroes are used as padding and discarded when they appear at the end of a pin. For example, when a pin of 1010 is sent to the GE over RS-232, the GE will interpret this as receiving PIN 101 and reject the code. 9. Armed in Away event maps. Due to limitations with the protocol in these panels, when the system is armed in any mode, the panel will first report that it has been armed in Away mode and then proceed to tell the controller that it has been armed in whichever mode the user has chosen. To accurately base an event map on an Armed Away state, the event map should start a Run Once system timer for the duration of the Exit Delay. Additional event maps should then cancel the timer if it is detected that the system is armed in modes other than Away. Any actual events should be based on the expiration of the timer. 10. Bypass Issues: For correct bypass operation, the panel and g! should both be set to the same bypass option. Discrepancies between the panel s bypass setting and g! s bypass setting can cause unpredictable results. 8 of 8