Vision Measuring Systems. Vision Measuring Systems. QUICK SCOPE Series. Catalog No.E14004

Similar documents
QUICK SCOPE. Non-contact Vision Measuring Machine Offers High Accuracy, Real Affordability and Powerful Functionality! Catalog No.

Vision Measuring Systems QUICK SCOPE Series VISION MEASURING SYSTEMS

QUICK SCOPE VISION MEASURING MICROSCOPES FOR AUTOMATIC MEASUREMENT AND DOCUMENTATION PRE1281(7) VISION MEASURING SYSTEMS

QUICK SCOPE. Quick Scope Non-contact Vision Measuring Machine Offer High Accuracy, Excellent Affordability and Powerful Capabilities!

Quick Scope. CNC/Manually-operated Vision Measuring Microscope

FORMTRACER CS Contour and Surface Roughness Measuring System

ROUNDTEST RA Roundness/Cylindricity Measurment

Profile Projector PH-3500

Surface Roughness/Contour Analysis Software

JSR GROUP. Profile Projector. PJ-A3000 SERIES 302 Profile Projectors

FORMTRACER SV-C3100/4100 Series

High Performance 2D Measurement System

Digital Measurement Metrology, Inc. Bulletin No Digital Measurement Metrology, Inc PRECISION IS OUR VISION

HOLTEST / BOREMATIC. Holtest Series micrometers make three-point / two-point bore diameter measurements at top accuracy. Catalog No.

(1)C-(CH) BU, Printed in Japan

Coordinate Measuring Machines Catalog No. E16013

Optical Measuring. Profile Projector. PJ/PV/PH Series. Catalog No.E14005(2)

Profile Projectors. Microscopes

Inspection Instrument for Indicators i-checker

Measuring Microscopes MF/MF-U Series Optical Measuring

AV300 VIDEO MEASURING SYSTEM.

AV300 VIDEO MEASURING SYSTEM.

ND 1300 QUADRA-CHEK the Digital Readouts for Convenient 2-D Measurement

ULTRA Quick Vision. CNC Vision Measuring System. ULTRA High Accuracy X/Y.25+L/1000µm, Z 1.5+2L/1000 Ultra High Resolution =.01µm (.

501, , 1052, , 1602, 1604 EXCEL EXCEL 1602UC EXCEL 1052UC EXCEL 501HC. Micro-Vu Corporation. Precision Measurement Systems

Image Measuring Instrument

FORMTRACER CS Contour and Surface Roughness Measuring System

HM-100. Micro Vickers Hardness Testing Machines. Redesigned range now even better for making hardness measurements on the smallest specimens

High-resolution Digimatic Measuring Unit LITEMATIC

Coolant Proof Micrometers MDC-MX Series

Quick Vision ELF Bench-Top CNC Vision Measuring Systems

2D MANUAL. is a manual 2D vision system with a massive difference.

Illumination Units Page 449. Measuring Microscopes Page 452. Microscope Units Page 479. Eyepieces and Objective Lenses Page 482

QV ELF SERIES 363 CNC Vision Measuring System

MF/MF-U SERIES MEASURING MICROSCOPES PRE1431 OPTICAL MEASURING

1D/2D Measuring Gage LINEAR HEIGHT

Micro Vickers Hardness Testing Machines

DIGIMATIC INDICATOR ID-H

SurfaceMeasure. Non-contact Line-Laser Probe for Coordinate Measuring Machines

Measuring Microscopes Hyper MF / MF-U

Roundness/Cylindricity Measurement ROUNDTEST RA-2200 Series

ND 1202 ND 1203 ND monochrome flat-panel display for position values, dialogs and inputs, graphics functions and soft keys

VISION MEASURING SYSTEMS

Industrial Metrology. Multisensor Measuring Machines O-INSPECT 322/442

Mu-checker To support building the system with automatic measuring unit or dedicated gages

Mini-Printer Equipped with Data Logging Function Digimatic Mini-Processor DP-1VA LOGGER

Magnifiers Page 424. Measuring Microscopes Page 426. Microscope Units Page 451. Eyepieces and Objective Lenses Page 454. Measuring Projectors Page 462

Form Measurement ROUNDTEST RA-1600

Manual Coordinate Measuring Machine CRYSTA-PLUS M443/M500/M700 Series

Complete support to all your needs. CNC Video Measuring Systems

Galileo Standard Series

TM-500 SERIES 176 Toolmaker's Microscopes

Product Information. QUADRA-CHEK 3000 Evaluation Electronics For Metrological Applications

AUTOMATIC HARDNESS TESTER ISOSCAN HV50 AC

MarShaft. MarShaft SCOPE 250 plus

Measuring range X / Y mm 100 / / /170 Z travel mm 200 / 400** Max. table load kg 20

VISION MEASURING SYSTEMS

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture

ROUNDTEST RA-120/120P

Linear, and segmented over up to 1000 points Squareness calibration Matrix compensation over up to 30 x 30 points

Accessories for Vision Systems Page 633

addition of 2-scale data mode calculator ABS/INC, SDM coordinate " ½" calculation ISL-DR2 addition of 2-scale data mode calculator

Portable Surface Roughness Tester SURFTEST SJ-301 Series

Surface Roughness/Contour Analysis Software

Coordinate Measuring Machines. Non-contact Line-Laser Probe for. Coordinate Measuring Machines. SurfaceMeasure. Catalog No.

AUTOMATIC MICRO-HARDNESS TESTER ISOSCAN HV1 OD

Diagonal FOV 18.5mm - 2.7mm ( inch); Video Magnification 30x-210x on 22" Monitor.

Microscopes. Projectors. Video. Accessories. Components. Page Katalog_E / 21/15

Multisensor Coordinate Measuring Machines ZEISS O-INSPECT

ND 1202 T. Axes 2 (XZ) Encoder inputs* » 1 V PP or «TTL (other interfaces upon request) Subdivision factor* 10-fold (only for 1 V PP ) Display step 1)

Optiv Classic 321 GL tp Technical Data

Optic accessories. Zubehör. Accessories

Multisensor Coordinate Measuring Machines ZEISS O-INSPECT

Profile Projectors. Microscopes

High definition digital microscope. visioneng.us/lynxevo

Measuring Microscopes/ Universal Measuring Microscopes. MF Series/MF-U Series Refer to pages J-11, 13 for details.

Flat-Field Mega-Pixel Lens Series

MML-PL25HR. 4-M3 (For Securing Lens) M3 Hexagonal Socket Set Screw (4 Screws Enclosed) ø ø19

Inspection Instrument for Indicators SMALL TOOL INSTRUMENTS AND DATA MANAGEMENT. i-checker. Bulletin No. 2239

Precision for People. SNAPFamily of Products

ROUNDTEST RA-120/120P

ZEISS O-SELECT Digital Measuring Projector

XCL-SG Series. XCL-CG Series. Digital Camera Module Equipped with the Global Shutter CMOS Sensor

OPERATION MICROSCOPES

User Manual. Binocular Zoom Stereo Microscope with Boom Stand. MicroscopeNet.com

Hardness Tester Micro-Vickers Type HM-100

Contracer CV-2100 SERIES 218 Contour Measuring Instruments

5-AXIS CNC CMM CRYSTA-APEX EX SERIES

ROUNDTEST RA-2200 SERIES

Software for Observation and Measurement SGMMS V2.6. Users Manual

Ch 22 Inspection Technologies

ZEISS O-SELECT Digital Measuring Projector

MarSurf. The new generation of contour measurement systems MarSurf XC 20 MarSurf XC 2

MEASURING MICROSCOPES

D-SCOPE The indispensable analysis tool for all diamonds

Evaluation Electronics For Metrological Applications

CONTRACER CV-3200/4500 SERIES

Measuring microscope VMM 100

MICROSCAN AC. Description AUTOMATIC MICRO-HARDNESS TESTER

QM-HEIGHT SERIES HIGH-PERFORMANCE HEIGHT GAUGE PRE1424(2) SMALL TOOL INSTRUMENTS AND DATA MANAGEMENT

Transcription:

Vision Measuring Systems Vision Measuring Systems QUICK SCOPE Series Catalog No.E14004

Refined Measurement Capabilities "Intuitive Operation" and "High Precision Measurement" Standard Software Software Intuitive software makes equipment operation easy for anyone. Optional Software QUICK SCOPE High-Accuracy Industry-leading liner scale is equipped with X, Y and Z axes. Optical Optical technologies designed to take the place of a human eye. Glass scales Lens design and manufacturing 2

The Quick Scope series can be used by anyone to easily perform everything from observation to automatic measurement of single or multiple items. Image measurement software QSPAK, which offers intuitive operability and advanced functionality can solve your measurement challenges. Used with the FORMPAK-QV application software, the Quick Scope series can also perform form analysis. Series Lineup QS Motor driven X, Y, and Z axes (zoom optics) CNC Measuring Range (X Y Z): 200 250 100mm Field of View: 9.5 7.1mm~1.3 1.0mm QS-L/AFB Manual X and Y axes, motor driven Z axis (zoom optics) XY: Manual Z: CNC Measuring Range (X Y Z): 200 100 150mm 300 170 150mm 400 200 150mm Field of View: 9.5 7.1mm~1.3 1.0mm QS-LZB Manually operated X, Y, and Z axes (zoom optics) Manual Measuring Range (X Y Z): 200 100 150mm 300 170 150mm 400 200 150mm Field of View: 8.8 6.6mm~1.2 0.9mm * See P6-P8 for detailed specifications. 3

Drastic Improvement in Working Efficiency Thanks to Functions Focused on Operability Programmable Optical Zoom Low to high magnification zooming provides support for both wide-field observation and high-magnification measurement, without the need to change lenses. The working distance is a constant 55mm, regardless of the magnification. The long working distance makes it possible to perform measurement on even uneven workpieces using the optimal magnification. The QS series provides a full set of automatic correction features, such as automatic light adjustment associated with a zooming operation, automatic position adjustment, pixel calibration, and more. QS, QS-L/AFB: 0.5X-3.5X (zoom ratio 7X in 8 steps) (26X-180X)* QS-LZB: 0.75X-5.25X (zoom ratio 7X in 8 steps) (29X-202X)* 0.75X (29X)* 1.5X (58X)* 3X (116X)* 5.25X (202X)* Fixed 55mm working distance * Total magnification shown in the above table is a reference value displayed in the default window state when using 22-inch wide LCD monitor. Illumination functions provide excellent support for measurement and observation In addition to contour and surface illumination, Quick Scope is equipped with a fiber-optic ring light to aid in reproducing color images more clearly. This illumination enables measurement and observation of images under optimal conditions. Control box Contour (stage) illumination Surface (coaxial) illumination Fiber-optic ring illumination During auto-measurement the measurement procedure program exercises automatic control over the illumination system, providing compatibility between user-friendliness and high efficiency. Frequently-used operations such as illuminating, data entry, zooming, and auto-focusing* can be performed with a single touch of individual buttons conveniently positioned near at hand. The CNC QS system allows remote operation with a jog shuttle. The manual QS system can be operated with a single touch of a button in the case of repeated measurement. * Auto-focusing function available only in QS and QS-L/AFB For QS For QS-L/AFB For QS-LZB 4

Stage sizes Allows selection of the perfect size of stage for the objects you need to measure. QS X Y 200 250mm QS-L/AFB X Y 200 100mm, 300 170mm, 400 200mm QS-LZB X Y 200 100mm, 300 170mm, 400 200mm Quick release mechanism Applicable models: QS-L/AFB, QS-LZB A quick release mechanism is installed on the XY stage of these models. Stage feed can be switched between Coarse and Fine (FREE and LOCK). Since this mechanism puts the stage in a completely free state, it greatly eases moving the stage if it is a long way to the next measuring point. Quick release knob AF tool Applicable models: QS, QS-L/AFB The AF (Auto focus) tool allows focusing without operator error, thereby achieving high-accuracy height measurement. Ambidextrous Z-axis feed Applicable models: QS-LZB Z-axis knobs are fitted to both sides of the column, making it easy to use for both left- and right-handed operators. The outside coarse-feed knob adjusts the Z axis 30mm per revolution, and the inside fine-feed knob feeds at 0.2mm per revolution. A contrast level meter is displayed, improving repeatability of focal positions in manual focusing. Coarse-feed knob Image before AF Image after AF Fine-feed knob Digital zoom function Digital zoom enables enlarged display and measurement of every detail. Low magnification Medium magnification High magnification 5

CNC Vision Measuring System QS Specifications Zoom lens system Model QS250Z Order No. 359-508-10* 1 Drive method X axis / Y axis / Z axis : CNC Optical Magnification* 2 Zoom: 0.5X-3.5X (in 8 steps) Measuring range (X Y Z) 200 250 100mm Resolution/Length standard 0.1μm/Linear encoder Image detecting unit 1/3" Color CCD camera E1X, E1Y (2.5+6L/1000)µm Measuring accuracy* 3 E1Z (5.0+6L/1000)µm Operating temperature range 20±1 C Drive speed Max 80mm/s Acceleration and deceleration Max 250mm/s 2 Stage glass size 269 311mm Maximum stage loading 10kg Stage light: 12V/30W Halogen Illumination Co-axial light: 12V/50W Halogen Ring fiber light: 12V/100W Halogen Dimensions (W D H)mm 465 815 663mm Mass 76kg Power consumption* 4 500W at max *1 The following suffixes are added to the Order No. 359-508-10: "Z" for UL/CSA and "Y" for CEE, BS, CCC, and KC Power cord is not attached as a standard accessory and it is required to prepare separately depending on the connector form. *2 Monitor magnification ratios unavailable. *3 Measuring accuracy (zoom lens system: 2.5X at the time of zooming in) under an installation environment of 20 C. *4 Only of QS main unit (excluding PC and monitor). Main unit power cord (option) System diagram Computer options Offline teaching software: EASYPAG Measurement support software: QS-CAD I/F Shape evaluation and analysis software: FORMPAK-QV Test chart creation software: MeasureReport Process irregularity management software: MeasurLink QS250Z * Printer is an optional accessory. An optional printer is not always the same as the above picture. QS250Z PC Set Standard software QSPAK For PSE (02ZAA001) For UL, CSA (02ZAA011) For CEE (02ZAA021) For BS (02ZAA031) For CCC (02ZAA041) For KC (02ZAA051) Device options Control box 2 (02APW610)* Joystick box (02ATD415)* Foot switch - standard type (937179T) Foot switch - high durability type (12AAJ088) Calibration chart (02ATN695) Dedicated table (02ATE760) * Concurrent use is impossible. Optical system magnification ratios available for QS Total magnification 26X 34X 44X 52X 78X 103X 129X 180X Field of View (mm) 9.5 7.1 7.3 5.4 5.6 4.2 4.7 3.5 3.1 2.3 2.3 1.7 1.9 1.4 1.3 1.0 QS 0.5X 0.65X 0.85X 1X 1.5X 2X 2.5X 3.5X Working distance (mm) 55 * Total magnification shown in the above table is a reference value displayed in the default window state when using 22-inch wide LCD monitor. 6

Manual Vision Measuring Systems QS-L/AFB Specifications Zoom lens system Model QS-L2010Z/AFB QS-L3017Z/AFB QS-L4020Z/AFB Order No. 359-703* 1 359-704* 1 359-705* 1 Drive method X axis/y axis : Manual Z axis : CNC with Auto focus Optical Magnification* 2 Zoom: 0.5X-3.5X (in 8steps) Measuring range (X Y Z) 200 100 150mm 300 170 150mm 400 200 150mm Resolution/Length standard 0.1μm/Linear encoder Image detecting unit 1/3" Color CCD camera X, Y (2.5+20L/1000)µm Indication accuracy* 3 Z (5.0+6L/1000)µm Operating temperature range 20±1 C Stage glass size 250 150mm 370 240mm 440 240mm Maximum stage loading 10kg 20kg 15kg Illumination Stage light: 12V30W Halogen Co-axial light: 12V50W Halogen Ring fiber light: 12V100WHalogen Dimensions (W D H)mm* Main Unit 624 705 722mm 682 852 837mm 757 867 837mm Mass 66kg 134kg 140kg Dimensions (W D H)mm Power Unit 186 452 381mm Mass 14kg Power consumption* 5 400W at max Computer options Offline teaching software: EASYPAG Measurement support software: QS-CAD I/F Shape evaluation and analysis software: FORMPAK-QV Test chart creation software: MeasureReport Process irregularity management software: MeasurLink PC Set Standard software QSPAK 7 *1 To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, C and No suffix are required for PSE. *2 Monitor magnification ratios unavailable. *3 Measuring accuracy (zoom lens system: 2.5X at the time of zooming in) under an installation environment of 20 C. *4 The width and height increase by the amount of the X axis and Z axis stroke at the maximum. The depth increase by the amount of half of the Y axis stroke at the maximum. *5 Only of QS main unit (excluding PC and monitor). System diagram *1 Adapter B (176-310) is required for 2010 model separately. Adapter (176-304) is required for 3017 and 4020 models separately. *2 Can be installed on Rotary table with fine-feed knob (A). It cannot be installed on Rotary table with fine-feed knob (B). QS-L3017Z/AFB * Printer is an optional accessory. An optional printer is not always the same as the above picture. QS-L/AFB Device options Foot switch - standard type (937179T) Foot switch - high durability type (12AAJ088) Calibration chart (02ATN695) Dedicated table (02ATE760) Stage options Rotary table Rotary table with fine-feed knob (A) (176-305) For 2010 size stages Rotary table with fine-feed knob (B) (176-306) For 3017 or 4020 size stages Swivel center support (172-197)* 1 * 2 Holder with clamp (176-107)* 1 * 2 V-block with clamp (172-378)* 1 * 2 Optical system magnification ratios available for QS-L/AFB Total magnification 26X 34X 44X 52X 78X 103X 129X 180X Field of View (mm) 9.5 7.1 7.3 5.4 5.6 4.2 4.7 3.5 3.1 2.3 2.3 1.7 1.9 1.4 1.3 1.0 QS-L/AFB 0.5X 0.65X 0.85X 1X 1.5X 2X 2.5X 3.5X Working distance (mm) 55 * Total magnification shown in the above table is a reference value displayed in the default window state when using 22-inch wide LCD monitor.

Manual Vision Measuring Systems QS-LZB Specifications Zoom lens system Model QS-L2010/ZB QS-L3017/ZB QS-L4020/ZB Order No. 359-710-1* 1 359-711-1* 1 359-712-1* 1 Drive method X axis / Y axis / Z axis : Manual Optical Magnification* 2 Zoom: 0.75X-5.25X (in 8steps) Measuring range (X Y Z) 200 100 150mm 300 170 150mm 400 200 150mm Resolution/Length standard 0.1μm/Linear encoder Image detecting unit 1/2" Color CMOS camera Indication accuracy* 3 X, Y (2.5+20L/1000)µm Z (5.0+40L/1000)µm Operating temperature range 20±1 C Stage glass size 250 150mm 370 240mm 440 240mm Maximum stage loading 10kg 20kg 15kg Illumination Stage light: 12V/50W Halogen Co-axial light: 12V50W Halogen Ring fiber light: 12V/100W Halogen Dimensions (W D H)mm* Main Unit 624 769 722mm 682 916 837mm 757 930 837mm Mass 72kg 140kg 146kg Dimensions (W D H)mm Power Unit 310 330 102.5mm Mass 5kg Power consumption* 5 160W at max *1 To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, C and No suffix are required for PSE. *2 Monitor magnification ratios unavailable. *3 Measuring accuracy (zoom lens system: 3X at the time of zooming in) under an installation environment of 20 C. *4 The width and height increase by the amount of the X axis and Z axis stroke at the maximum. The depth increases by the amount of half of the Y axis stroke at the maximum. *5 Only of QS main unit (excluding PC and monitor). System diagram Computer options Measurement support software: QS-CAD I/F Shape evaluation and analysis software: FORMPAK-QV Test chart creation software: MeasureReport Process irregularity management software: MeasurLink *1 Adapter B (176-310) is required for 2010 model separately. Adapter (176-304) is required for 3017 and 4020 models separately. *2 It can be installed on Rotary table with fine-feed knob (A). It cannot be installed on Rotary table with fine-feed knob (B). QS-L2010ZB * Printer is an optional accessory. An optional printer is not always the same as the above picture. QS-LZB PC Set Standard software QSPAK Device options Foot switch - standard type (937179T) Foot switch - high durability type (12AAJ088) Calibration chart (02ATN695) Dedicated table (02ATE760) Stage options Rotary table Rotary table with fine-feed knob (A) (176-305) For 2010 size stages Rotary table with fine-feed knob (B) (176-306) For 3017 or 4020 size stages Swivel center support (172-197)* 1 * 2 Holder with clamp (176-107)* 1 * 2 V-block with clamp (172-378)* 1 * 2 Optical system magnification ratios available for QS-LZB Total magnification 29X 38X 49X 58X 87X 116X 145X 202X Field of View (mm) 8.8 6.6 6.8 5.1 5.2 3.9 4.4 3.3 2.9 2.2 2.2 1.6 1.7 1.3 1.2 0.9 QS-LZB 0.75X 0.98X 1.28X 1.5X 2.25X 3X 3.75X 5.25X Working distance (mm) 55 * Total magnification shown in the above table is a reference valve displayed in the default window state when using 22-inch wide LCD monitor. 8

Dimensions QS250Z Unit: mm 465 815 QS-L/AFB 2010/3017 Dimensions in parentheses indicate those for model 3017. 100 (124) Maximum: 824 (956) Maximum: 755 (937) 624 (682) 100 (150) 50 (85) MCN-25 705 (852) MCN-50 200 Maximum: 1157 757 200 100 Maximum: 967 867 QS-LZB Maximum: 824 (956) Maximum: 819 (1001) 100 (124) 624 (682) 100 (150) 50 (85) 769 (916) Maximum: 1157 Maximum: 1031 200 757 200 100 930 1462 (1577) 945 (987) 740 205 (247) 722 (837) 1577 987 740 247 837 1462 (1577) 945 (987) 740 205 (247) 722 (837) 1577 987 740 247 837 740 1403 160 663 1800 900 mm 0 25 25 50 4020 1800 900 1800 900 2010/3017 Dimensions in parentheses indicate those for model 3017. 4020 1800 900 1800 900 9

QSPAKR A powerful vision measuring software system that supports a wide variety of measurement In order to support various measuring methods from measurement of a wide variety of single parts to CNC measurement of mass production parts, QSPAK has achieved both high-reliability vision detecting capability and user-friendly operability. Counter window Graphics window Video window Tools window Functions window Illumination/stage window Measurement window Measurement result window Measurement Commands Covering Basic Methods of Measurement Coordinate system creation commands Measurement item commands * Item names are not actually displayed, but displayed as on-line help. 10

Tools that Reduce Personal Error and Improve Repeatability One-click tools l Patent pending (Japan) A single click in the vicinity of a workpiece edge allows automatic processing from tool setting to edge detection/calculation. Additionally, this function does not need stage movement for any workpiece measurement within a screen, drastically reducing measurement time. Auto-trace tool This is a tool for form measurement in which the edge of an arbitrary form is detected with multiple points at a time. One-click circle tool One-click box tool Convenient Tools Effective for Various Measuring points * The Auto-trace tool of QS-L/AFB and QS-LZB, only functions within a screen. Multi-click Plus Arc Tool Overall drawing tool size, scan direction size, and edge selector positions can be set as desired. This tool is effective for the measurement of arcs with small R angles, and for objects with many irregularities, whose edges are not easily identified. Datum Circle Measurement In addition to calculating mean-circle measurements using the standard least-square method, the QS series can also perform calculations based on interior diameter (maximum inscribed circle) and external diameter (minimum circumscribed circle). This measurement approach is useful for circle measurement of the contact sides of fitted components, etc. Template tools Basic templates The following are three basic templates corresponding to the reticle of a microscope. Extension templates Extension templates are provided based on four types of pattern: crosshair; circle; rectangle; and angle. A diameter, distance, angle, and other value can freely be set by key entry in the same manner as used in comparison measurement with a profile projector. Cross hairs Crosshatch Concentric circles User pattern matching The user can freely create a template (master) to suit practically any a workpiece, different from the basic templates and extension templates to perform tolerancing with a master. Also, the user can easily perform tolerancing by displaying key-entered upper limit and lower limit lines on the screen. Upper limit value Design value Lower limit value Angle template Circle template CAD user template function This function allows a template to be created using a form (CAD data) in the Graphics window. * To create a template, CAD data needs to be imported and exported. 11

Convenient Functions to Simply Execute and Edit an Auto-measurement Procedure Program One-click simple execution function Program Launcher An auto-measurement procedure program can be associated with a dedicated icon along with a photo and comments to enable a program to be started by a single click. A total of 10 icons are provided and programs can be managed for each operator or workpiece using these icons. Program launcher icons Smart editor Auto-measurement procedure program association window This function allows an XY-stage position, lens magnification, illumination condition, etc., to be separately displayed as icons or labels in the list of part programs (auto-measurement procedure programs), thereby simplifying program editing. Editing an illumination condition according to the dialog Editing design values and tolerances according to the dialog Navigation Function Contributes to Reduction in Measurement Time This stage navigation function enables pinpoint positioning when the stage needs to be moved significantly. To move the stage, click the point in the Graphics window to which the stage is to be repositioned. Then, the stage directly moves to the point. This can suppress wasted stage motion such as overrun or inefficient run to the minimum. To accurately move Stage movement with the Graphics window Editing a direct tool on the Video window Stage navigation (QS) l Patent registered (Japan) Click this point the stage, click a point to move to the center of the Video window with the mouse. Then, the stage accurately moves to the center of the Video window. The use of this function will significantly reduce the creation time needed for a part program. Stage movement with the Video window Click this point Specify the point which you want to center in the video window Specify the point which you want to center in the video window 12

Quick navigation (QS-L/AFB, QS-LB) l Patent registered (Japan) This is a navigation function that concurrently uses the Learn/Repeat function for storing and reproducing a series of measuring procedures. This function navigates the operator to the next measuring point in accordance with the measuring procedure stored. Move the stage until the red cross-hairs indicating the next measuring point coincide with the green cross-hairs at the center of the monitor screen. Then, the view at the next measuring point will appear on the screen. This function also allows zero approach using the digital counter. The operator does not need to check a measuring point while looking at a workpiece and can perform measurement while concentrating on the screen. (1) The next measuring point is indicated with the red cross-hairs. (2) As the stage approaches the next measuring point, the red cross-hairs and green cross-hairs get closer to one another. (3) When the two cross-hairs coincide and the target view appears, press the Enter button to complete the measurement. Enhanced Capabilities Supporting Tasks from Operator Management to Inspection Report Creation Graphics window Measuring features and measurement results are displayed in real time in the Graphics window. This allows the operator to verify measurement points with visual images. Measuring features can also be selected from graphics, thus allowing speedier measurement. Calculation between features is possible using the Graphics window. Icon editor The layout of measurement item icons, tool icons, etc., can be freely rearranged. The operator can apply free icon configuration in which, for example, frequently used icons are grouped on the first page. This function restores the range of use depending on the task level by requesting password entry when QSPAK starts up. Security function Video image scale display Scales in accordance with the actual field of view can be displayed on the Video window to quickly estimate size of a workpiece. If workpiece images are stored along with scale indication, it gives a rough indication of the size of each workpiece. Image storage Color images in the Video window can be output as a file in BMP or JPG format. Also, the images can easily be attached to the record of workpiece graphics, inspection report, etc. Measurement report l Patent pending (Japan) Measurement results obtained by a part program can be output as they are in CSV format. Since the results are output to commercial spreadsheet software such as Excel, you can create a company specific inspection report. 13

Options Lineup of Application Software to Meet Advanced Measurement Requirements Form assessment and analysis software FORMPAK-QV This 2D data processing software reads in point group data acquired via tools such as the auto trace tool, performing shape analysis. * Auto tracing is performed of areas displayed on the monitor for the QS-L/AFB and QS-LZB. Examples of fine dimension analysis The dimensions of fine shapes displayed on-screen can be measured using intuitive controls. Measurement support software QS-CAD I/F CAD data created during the design phase (DXF- or IGESformatted) can be imported into QSPAK. QSPAK measurement results can also be converted into CAD data. Features The design value for each measurement item is automatically entered. The stage can be quickly moved to a given point in the CAD data. Graphic data can be output in a specified CAD format. Example of gear contour matching and overpin diameter analysis The software can be used to perform contour matching against the design value data. You can define virtual circles of any desired diameter. Test chart creation software Excel test chart program MeasureReport This software can be used to summarize Quick Scope measurement results in a test chart. Process irregularity management software MeasurLink Statistical data can be displayed in real-time, making early detection of process irregularities possible. Data change-points can be analyzed in order to identify problems, and swiftly implement prevention measures when the problems are part of a trend. Usage examples Mold adjustment and replacement timing measures Cutting tool adjustment and replacement timing measures, etc. 14

Peripherals Calibration chart Options compatible with All Devices Foot switch - standard type Foot switch - high durability type Dedicated table Order No. 02ATN695 Used for CCD pixel size calibration, as well as Application autofocus accuracy and optic axis offset calibration for individual zoom levels. Order No. 937179T Order No. 12AAJ088 Order No. 02ATE760 Exterior dimensions 1800(W) 900(D) 740(H)mm Mass 60kg Control box 2 Joystick box QS Options Order No. 02APW610 Order No. 02ATD415 QS-L/AFB and QS-LZB Options Rotary table with fine-feed knob (A) 280 256 220 30 Order No. 176-305 Exterior 280(W) 280(D) 24(H)mm dimensions ø240mm table top 360 rotation - No angle readout Mass 5.5kg Effective glass diameter ø182 (mm) Note) The V-block with clamp, swivel center support, and holder with clamp can be secured to the top of the table. 280 220 31 29 120 70 37 ø188(mounting glass glass exterior exterior diameter) diameter) ø182 (Mounting glass effective diameter) ø220 Rotary table with fine-feed knob (B) Order No. 176-306 Exterior 342(W) 342(D) 23(H)mm dimensions ø270mm table top 360 rotation - No angle readout Mass 6.5kg Effective glass diameter ø238 (mm) Note) The V-block with clamp, swivel center support, and holder with clamp cannot be secured to the top of the table. ø245(mounting glass exterior diameter) øø270 ø 241Table interior diameter 241Table interior diameter ø238 (Mounting glass exterior diameter) Clamping screws (2) (96.361) ø62 13 8 ø 240 24 ø 50 2-ø7 holes, Mouth: ø14, Counterbore depth: 4 Clamping screws (2) (103.945) 2-M6 8 ø184 Table ( interior diameter 282 342 19 ø28 12 23.7 10.5(0.2) M6 Clamping screw 13 8 13 2-M6, Depth: 8 (103.945) Rotation knob 22.5 4-C 58 58 ø28 220 342 (137.618) (0.7) 9.5 13 Rotation knob 23.2 19 M6 Clamping screw Holder with clamp V-block with clamp Swivel center support Stage adapter Stage adapter B Order No. 176-107 Maximum clamping 35mm length Exterior dimensions 62(H) 152(W) 38(D)mm Mass 0.4kg Order No. 172-378 Maximum supportable diameter: ø25mm Center height from mounting surface: 38~48mm Exterior dimensions 117(H) 90(W) 45(D)mm Mass 0.8kg Order No. 172-197 Can be set to tilt of ±10, in minimum angle increments of 1 Optimal for measurement of screws, etc. Maximum supportable dimensions: ø80x140mm when horizontal Maximum supportable dimensions: ø65x140mm when tilted at 10 angle Mass 2.5kg *Adapter B (176-310) is required for 2010 models separately. Adapter (176-304) is required for 3017 and 4020 models separately. Stage adapter: 176-304 Order No. Stage adapter B: 176-310 Exterior dimensions 50(W) 340(D) 15(H)mm per adapter Note) Adapter B is 280mm deep Mass Stage adapter: 1.5kg Stage adapter B: 1.2kg These are used when connecting Application some optional peripherals to the measurement device. Note) One set consists of two adapters 15

Export permission by the Japanese government may be required for exporting our products according to the Foreign Exchange and Foreign Trade Law. Please consult our sales office near you before you export our products or you offer technical information to a nonresident. 33 1311(1)C-(CH)HS, Printed in Japan Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this pamphlet, as well as other technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs, dimensions and weights. The stated standards, similar technical regulations, descriptions and illustrations of the products were valid at the time of printing. Only quotations submitted by ourselves may be regarded as definitive. Our products are classified as regulated items under Japanese Foreign Exchange and Foreign Trade Law. Please consult us in advance if you wish to export our products to any other country. If the purchased product is exported, even though it is not a regulated item (Catch-All controls item), the customer service available for that product may be affected. If you have any questions, please consult your local Mitutoyo sales office. Mitutoyo Corporation 20-1, Sakado 1-Chome, Takatsu-ku, Kawasaki-shi, Kanagawa 213-8533, Japan T +81 (0) 44 813-8230 F +81 (0) 44 813-8231 http://www.mitutoyo.co.jp